Tender For Provn Of Interlocking Path Way From Main Road To Bldg No T-120, Provn Of Store Room ,Provn Of Ration Store At Certain Mil Unit,Addn/Altn Of Bldg No T-681 Of Certain Mil Unit In Hasimara Under Ge (S) Binnaguri.
Tender Overview
Project Description
Tender for Provn Of Interlocking Path Way From Main Road To Bldg No T-120, Provn Of Store Room ,Provn Of Ration Store At Certain Mil Unit,Addn/Altn Of Bldg No T-681 Of Certain Mil Unit In Hasimara Under Ge (S) Binnaguri.
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc. 30cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified. |
| 2 | M & L for hardcore guage of broken stone or boulders of exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified. |
| 3 | M&L for 150 mm thick cement concrete 1:3;6 type C-2 (using 40 mm graded stone aggregate) as in path/ steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tilling complete all as specified. |
| 4 | M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified. |
| 5 | Excavation in trenches n.exc 1.5 in deep and n.exc 1.5 m wide for foundation etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified. |
| 6 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. |
| 7 | M& L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified. |
| 8 | M&L for PCC 1:3:6 type C-1 (using 20mm graded aggregate) as in copings/haunching including necessary form work etc complete all as specified. |
| 9 | M&L for applying two coats of synthetic enamel paint over a priming coat including preparation of new concrete surface over 10cm width or girth complete all as specified. |
| 10 | Returning filling in, incl spreading, levelling watering & well ramming in layers n.exc 25cm in hard/dence soil complete all as specified. |
| 11 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified. |
| 12 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated flush box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls with 3mm thick,suitable modular top cover plate with frame fixed for housing modular switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be stone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specifiedfor the following :- One light point controlled by one way switch 5/6 amps. |
| 13 | One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps complete all as specified. |
| 14 | One socket out let 5/6 amps point on the same board complete all as specified |
| 15 | One socket out let 5/6 amps point on the independent board complete all as specified |
| 16 | All as per item No1 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified. |
| 17 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified. |
| 18 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified. |
| 19 | S&F socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified. |
| 20 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified. |
| 21 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified |
| 22 | S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified. |
| 23 | S & F Wall monted slim LED inverter batten 20W 4' long, ,min output not less than 120 Lumen/watt PF>0.95,surge protection,> 4KV, THD:<10% with PC housing, with integrated LED driver complete all as specified. |
| 24 | S&f LED recessed mounted light ( 600 mm x 600 mm),35/36 w suitable for indoor space including provision of three core PVC cable of copper conductor of size 23/.0076 and making connection complete all as specified |
| 25 | S & F LED light fitting 1x9W/1X10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified |
| 26 | Supply and fix Exhaust fan, turbo jet heavy duty steel body Ac single phase 230V, 50 Hz, RPM 1400, Copper winding of sweep 380mm 1400 rpm with blade frame and louver complete and provision of 3 core flexible multistranded copper conductorof size 0.75 Sqmm from ceiling rose to fan all as specified. |
| 27 | Supply and fix Air circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as directed. |
| 28 | S&F Sheet metal enclosure for 12 way Distribution Boards (DB’s), double door, single pole & neutral 240 Volt s with with tinned copper bus bar neutral bus bar ,earth bar ,din rail interconnections powder painted complete. suitable for fixing MCB\\"S/lsolators complete all as specified. |
| 29 | S&F MCB, Single pole & neutral 40 amps, 240 volts, ‘C’ curve, 10 KA all complete all as specified. |
| 30 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete all as specified. |
| 31 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified. |
| 33 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 34 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified |
| 35 | Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 10 Metres in length, in any type of soil, suitable for passing through up to 50 mm bore, galvanised steel tubing,complete all as specified. |
| 36 | M&L for surface dressing n exc 15 cm deep for adjoining area complete all as specified. |
| 37 | M&L fly ash Brick work using modular size bricks with sub class 'B' bricks curved on plan with mean radius not exc 6m with bricks roughly cut to radius or bricks with wedge shaped joints built in cement mortar 1:6 complete all as specified. |
| 38 | M&L for RCC (nominal mix) 1:1.50:3. type B1 using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified. Note - Reinforcement and form work shall be measured and paid separately. |
| 39 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified.Note - Reinforcement and form work shall be measured and paid separately. |
| 40 | M&L for RCC nominal mix type A1,1:1.5:3 using 20mm gradded aggregate Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified. |
| 41 | Form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves, for flat rough finished concrete surfaces complete all as specified. |
| 42 | Form work to sides of concrete foundation ,footings, bases of columns, raft and raft beams sides and soffits (if any )of foundation and plinth beams for flat rough finished concrete surface complete all as specified. |
| 43 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in chajjas and similar work complete all as specified.Note - Reinforcement and form work shall be measured and paid separately. |
| 44 | Form work to chullah hood, chajjas, troughs and similar items including edges etc for rough finished flat concrete surface complete all as specified. |
| 45 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 46 | Mild Steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 47 | Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 48 | M&L for 40 mm thick in Cement concrete 1:2:4, type B-0 Damp proof course to horizontal or vertical surfaces including necessary formwork and mixed with water proofing compound 0.25Ltr/ Sqm or as per manufacturer's instructions complete all as specified. (Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'). |
| 49 | M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'). |
| 50 | Supply only Liquid water proofing compound all as specified. |
| 51 | M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified. |
| 52 | M & L for preparing newly plastered surfaces of walls and applying three coats of white wash.on wall all as specified. |
| 53 | M & L for preparing new Plastered surfaces of walls and applying two coat of cement base paint on surface of wal all as specified. |
| 54 | M & L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm). Make of Weather proof exterior acrylic emulsion and primer : Asian Apex Ultima/Berger weather coat long life 10 all as specified. |
| 55 | S & F Structural steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde -E-250 quality- A) Add to any of the foregoing items if structural steel is painted one shop coat of zincchromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication all as specified. |
| 56 | S & F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410-W (Gde E-250 quality B) with riveted, bolted or welded attachment complete all as specified. |
| 57 | M&L of two coat of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth incl preparation of surfaces complete all as specified. |
| 58 | S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/ cladding/ eaves board fixed with selp tapping screw complete all as specified. |
| 59 | S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding/eaves board fixed with selp tapping screw complete all as specified. |
| 60 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified. |
| 61 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. |
| 62 | M&L for Non asbestos fibre cement building boards fixed or laid/ inserted totimber/GI/Aluminium framework with screws ,4mm thick designer board (610mm x 610mm ) size complete all as specified. |
| 63 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including wateringcomplete all as specified . |
| 64 | M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified. |
| 65 | M&L for Machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 15 mm thick screed bed or bedding layer in CM 1:4 surface finished fair and even for laying floor finishescomplete all as specified. |
| 66 | M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 20-25 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. complete all as specified. Please Enable Macros to View BoQ information |
| 67 | M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 20-25 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender