Tender for Dnit For The Work Of Instrument For Waste Water Testing Parameter For Testing Of Water S Le At District Lab Gurugram And All Other Works Contingent There To.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of executive office 6x 3.5 table with glass foamheavy drawer with heavy lock termite proof plywoodand good quality sanmica |
| 2 | Fire extingusher ABC TYPE |
| 3 | Supply of 20 watt LED tube light of Philips /Syska |
| 4 | Muffle Furnace• Rectangular Muffle Furnace: Maximum Temp. 950°Cworking temp.900°C.The outer casing is made of doublewalled thick P.C.R.C. sheet painted with attractive stoveenamel. Outer body of S. S. 304 grade. Heatingelements are made of KANTHAL wire backed by cerawool insulation. temperature control unit consists ofEnergy regulator and Digital Indicator with silverthermal fuse or with PID Micro Processor controllerdual display with safety alarm to work on 220/230 voltsAC with an accuracy of ± 2°C or Better.• Along with Digital timer of 99.59 Hours, size -10x5x5 inches. Control panel- Mains, Load Indicator, DigitalController and Mains Indicator.• NABL Calibration certificateMake: Ambassdor, NSW, Optic, Impact, SkybondType of Testing: Used for Chemical Testing (CT) andWaste Water Testing (WWT) |
| 5 | HOT AIR OVEN: -• Size: 18x18x24 inches• Precise Sterilization, Incubating and drying in oneunit.• Better mineral / glass wool blanket insulation keepsthe surface of the Instrument from being burnt.• Silent Hot Air blower unique Design of air circulationfor uniform Air movement.• Unique design of Ventilation keeps the surface of theinstruments from being burnt.• Polish 304 grade S.Steel interior corrosion resistantlong-life operation having adjustable shelves to make more space for differentheight.• Kanthal A-1, Super quality coil shaped heaters dulyembedded / wounded on the sides and bottom for betteraccuracy.• Full feature with Touch Screen ControllerTemperature Controller:• HMI Display with Feather Screen Touch DigitalTemperature Controller• Continuous display of Temperature, Time, Day andDate Door Open Alarm• Password Protected operations,• Data transfer port: USB portTechnical Specification:Microprocessed Electronic Digital Controller cumIndicator from few `C above ambient to 300°C ±0.5°Chaving two windows display SV (Set value) and PV(Process value), auto tuning, timer up 999 min(selectable) low and high temperature accuracy alarm,cycle, timer with buzzer.• Temperature Stability: ± 0.5°C• Control Panel: With Mains and Load Indicator,MCB Alarm• Material: GI/ MS with Powder Coated• Inner: Stainless Steel 304• Digital Setting: 0.1°C• Digital Resolution: 0.1°C• Safety Function: Temp Over shoot high and LowTemp. Alarm ± 5°C, MCB Provided• Insulation: Mineral Wool• Front Door: Mineral wool insulated doorwith glass window• Hardware: Lock and Handle Material Zinc,Base Finish: SPC, Handle Finish: Black PC with keyHinges Material Zinc, Pin Material: SS 304 Grade,Finish STPC, Opening Angle: 180 Deg• Power Consumption: 220 /230V AC Supply ± 10%.50 HZ• Duty Cycle: Continuous• Traceability calibration certificate of controller shouldbe provided.• Instrument should be calibrated from NABLcalibration laboratory. Steel stand should be providedalong with tyres on which instrument has to be keptMake: NSW, Optics Technology, Ambassdor, ImpactType of Testing: Used for Chemical Testing (CT),Bacteriological Testing (BT) and Waste Water Testing(WWT) |
| 6 | Supply of steel Racks 90x195x50.7 cm / material mildsteel / delivery condition- knock down/ free assemblyprovided Steel construct- CRCA steel Make- Godrej/Alfa |
| 7 | COD Digital Reactor• Reflux Type: Closed• COD Digital Reactor- 15 holes or moreThree Temperature RangesThe reactor can operate optionally with 100°C, 120°Cor 150°C – depending in each case on the sample to beprepared.•Three Different Reaction TimesThree different reaction times are available with 30, 60and 120 minutes. Your advantage: Afterwards the unitswitched itself off automatically.•Large Cuvette ShaftPlace up to 24 ,16-mm-round cuvettes•Heating-up Rate-20 °C - 150 °C•Selected Time-30 / 60 / 120 / 150 / minutes andcontinuous operation.Make: HACH, Lovibond, WTW, MerckType of Testing: Used for Waste Water Testing (WWT) |
| 8 | Prov. and fixing split heavy duty all weather airconditioner of 1.5 tone with voltage stablizer MakeMistubshi/ O.General GST Inclusive. |
| 9 | Laboratory Refrigerators • Vertical Shelves at least 6 forstorage of samples, Storage Capacity 500 Litres alongwith in-built digital temperature controller (companyfitted). • Door for restricted accessibility. Castor wheelsfor easy mobility. Toughened glass door. • Enableddigital temperature controller to check and maintaininside temperature. • NABL calibration certificate.1year warranty as desired by concerned lab. Make:Cellfrost, Haeir, Whirpool Type of Testing: Used forChemical Testing (CT), Bacteriological Testing (BT)and Waste Water Testing (WWT) |
| 10 | Separating Funnel • Separating, Pear Shape, Fitted withBoroflo Stopcock with PTFE Key and InterchangeableStopper Complies with IS 1575, DIN / ISO 4800 ŸMade 3.3 borosilicate glass, USP Type I Ÿ Equippedwith a Boroflo stopcock with PTFE key Ÿ Pear shape,with a stem Ÿ Generally used in the separation phase6402-Funnels ,2000 ML Capacity along with standMake: Borosil, Therofischer,Glassco, Duran Type ofTesting: Used for Waste Water Testing (WWT) |
| 11 | Kjeldahl Equipment Distillation system for Nitrogenestimation • Microprocessor controlled automaticdistillation, steam addition, alkali addition, boric acidaddition and auto tube drainage • Pre-defined editableuser storage program • The unit can work with distilledwater can or direct tap water with water softener. • Bodyconstructed of glass reinforced polymer for enhancedurability • Programmable Reaction Time withContinuous real time monitoring of steam temperature,display at the time of water filling and other parameters• 7`` touch screen display and Tube capacity of 250mland 400ml • Reagent level sensors • Removable bottomtray material perfluoroalkoxy for extra protectionagainst acidic attack • Threaded tube connectors forquick removal of glass components for maintenance • Auto tube inserts error indication. • Easy water andsteam drainage from the boiler for effective steamgeneration. • Automatic Steam dosing in test tube withuser selectable from 10% to 100% • Combined bulb andcoiled condenser with condensing surface area 550 Sqcm, SS 304 steam generator • Heat delay of less than240secs • Distillation collection time (mins) of 5-7minsfor recovery of more than 99.5% • Cooling water flowrate with minimal of 0.5L/min • One point calibration ofWater and NaOH pumps. • 2-point calibration for acid pump with an accuracy of 0.1ml. • Inbuilt Nitrogencalculator with Nitrogen and protein in different formats• Interface provided for connectivity to printer or PC • Nitrogen recovery )99.5%, Nitrogen reproducibility ±1 %, RSD of (1%, Nitrogen levels of 1-200mg with LODof =0.1mg of Nitrogen Digestion system for Nitrogenestimation • 250mL, 6 position capacity block digestionsystem of 220/230 V • Maximum temperature 470 °C with precision of ± 1 °C. • Front Glass ReinforcedPolymer control panel • Graphical representation afterend of the cycle with LCD display. PID based controlsystem • Single point and two-point calibration oftemperature • Pre-defined memories of which more than20 are user-programmable • Ramping of at least 4 rampsper program • Data transfer port for PC or printerconnectivity • Auxiliary cooling stand with thawing fansfor faster sample cooling. • 2.8 KW SS316 casedcartridge for long heater life. • All essential accessorieslike digestion tubes, SS insert rack, exhaust manifold,suction assembly for safe removal of acid fumes to beprovided with the unit. Fume extraction system forNitrogen estimation • Fume scrubber with 28 LPMcapacity for complete evacuation of acid fumes. • 2 litrecondensation and neutralisation jars for larger fumevolumes. • MOC for bottles 3.3. expansion borosilicatebottles and body epoxy painted • 29/32 ground glasswith viton liners for quick removal and assembly ofcondenser and fume trap • Threaded tube connectors forquick removal of glass components for maintenance • Transparent PC Protective front shield and easilyremovable bottle tray. • Carbon adsorption bottleremoval any trace acid from exhaust air • Four-way acidneutralisation through Condenser, trapping in distilledwater, trapping in Alkali trapping and Carbon filter • Vacuum technology for water circulation for long life ofthe pump • Automatic cooling water cut off post processcompletion for water saving • online demonstrationbefore technical qualification • Customer appreciationletter on customer letterhead and relevant POs to beprovided minimum 20 nos. Chiller with KjeldahlSystem • Recirculation system is designed to reduceenergy consumption and maximize refrigeratingefficiency. • Temperature ranges from -10? to Ambient(CHL) • High cooling capacity up to 1kW at 20 deg. • Easy-to-read LED display with interactive touch keys. • Setting and resolution indication 1 deg. • PU Wheels forHigh-Capacity Models easy mobility • 100 testchemicals along with this equipment. • Self-diagnosticfunction identifying errors viz. Temp Probe /Compressor. Make: BOROSIL, Buchi, Foss, Velp,Glassco Type of Testing: Used for Waste Water Testing(WWT) |
| 12 | Thermometer Simple and with Probe • Type K, with0.1° high resolution • measurement range: -50 to1300°C • Digital LCD Thermometer with sensor probe. • Alongwith NABL calibration certificate Make: LT, HTC,Hicks Type of Testing: Used for Chemical Testing(CT), Bacteriological Testing (BT) and Waste WaterTesting (WWT) |
| 13 | Analytical Balance Accuracy/resolution 0.01 mg withinternal calibration Pan Size Ø 90 mm along with NABL Calibration certificate. • Provide Acrylic sheetcabinet box along with weighing balance (2 feet × 2 feet × 2 feet) or as required by laboratory. • 1 year warranty.Make: Radwag, Mettler Toledo, Sartorius, ShimadzuType of Testing: Used for Chemical Testing (CT),Bacteriological Testing (BT) and Waste Water Testing(WWT) |
| 14 | Autoclave • Digital Display • Heater: 4.0 kW • Size:400 x 600 mm (78 L) • It should have double wallconstruction with boiler made of Stainless Steel 16-gauge sheet. Outer shall be also made of Stainless-SteelSheet/ Mild Steel. Boiler and outer shell are providedwith air insulation. Lid is made of Stainless-Steel Sheetand tightened all-round by radial locking. Joint lessgaskets are made of Neoprene rubber. These sterilizersare hydraulically tested upto 40 PSI. • Should have fullyautomatic PID Controller • Unique design of Radiallocking for minimum steam loss, assure accurate steamgeneration / sterilization • Outer SS sheet chamber innerS.S. 304 • Pressure accuracy: PSI ± 3 PSI or better • Automatic timer electronic 999 minutes • Sterilizers arefitted with water level arrangement to indicate waterposition inside the boiler. Pressure gauge, Air/Steamrelease cock two safety valve are also provided. Theautoclave is fitted with indfosspizzostat and can be setbetween 10 to 20 PSI. • Inner and outer wall both madeof Stainless Steel. Lid is made of thick machinedstainless-steel plate. Support ring and legs are also madeof stainless steel. Gasket is made from importedSILICON rubber. Fitted with microprocessor basedfully automatic fuzzy logic control system with timerbuzzer (Auto Time Control). The unit is also fitted withlow-water level cut-off as a standard feature. Fitted withautomatic purging and exhaust valve. • Immersion typeheating element heats the water and steam to desiredtemperature and pressure are attained. Autoclaves tocut-off automatically when the autoclave is dry.Supplied complete with S.S. basket, cord and plug towork on 220 Volts 50 cycles A.C. supply. • Steel standshould be provided along with tyres on whichinstrument has to kept. • Traceability calibrationcertificate of controller should be provided • Instrumentshould be calibrated from NABL calibration laboratory.• Vertical or horizontal will be decided by the concernedlaboratory Make: NSW, Ambassador, Impact Type ofTesting: Used for Chemical Testing (CT),Bacteriological Testing (BT) and Waste Water Testing(WWT) |
| 15 | Bacteriological Incubator • Size: 18x18x24 inches • Precise Sterilization, Incubating and drying in one unit.• Better mineral / glass wool blanket insulation keepsthe surface of the Instrument from being burnt. • SilentHot Air blower unique Design of air circulation foruniform Air movement. • Unique design of Ventilationkeeps the surface of the instruments from being burnt. • Polish 304 grade S. Steel interior corrosion resistantlong-life operation having adjustable shelves (shelves asrequired by lab) • to make more space for differentheight. • Kanthal A-1, Super quality coil shaped heatersduly embedded / wounded on the sides and bottom for • better accuracy Make: NSW, Ambassdor, OpticsTechnology, Impact Type of Testing: Used forBacteriological Testing (BT) |
| 16 | Fume Hood • Type: Bench-mounted, Class B Type • Application: Removal of hazardous fumes, vapors, andgases from laboratory experiments • Compliance:Designed as per IS: 14156 / international safetystandards • Outer Body: CRCA (Cold Rolled CloseAnnealed) steel sheet, powder-coated with epoxy finish(corrosion and chemical resistant). • Inner Lining:Acid/alkali resistant phenolic resin sheet / FRP lining /epoxy coating (depending on model) • Worktop: Blackgranite slab / epoxy resin / ceramic, resistant to solvents,acids, alkalis • Sash (Front Panel): Vertical sliding sash,made of 5–6 mm toughened glass, counter-weightbalanced, smooth and safe operation • Face Velocity:100 ± 20 FPM (feet per minute) at sash opening • Blower: FRP/PP centrifugal blower 2400 cfm,dynamically balanced • Motor: 1.5 HP, single-phase 230V, 50 Hz (depending on hood size) • Noise Level: ( 70dB • Ducting: Compatible with PVC / PP / FRPchemical resistant duct with damper • Lighting:LED/fluorescent light, minimum 800–1000 lux at worksurface • Sockets: 2–3 nos., 5/15 A, 230 V, with MCBprotection • Service Taps (as required): Gas valve(LPG/Natural Gas), Water tap with PP sink, Vacuumline connection • Airflow monitor, sash positionindicator, emergency switch • Vertical sash withcounterweight for operator safety • Aerodynamic designto ensure uniform airflow • Fire-retardant materials forinner lining • Emergency cut-off switch for blower andpower supply • Airflow alarm/monitor • OverallDimensions with base cabinet: 2010 mm W X 1000 mmD X 2400 mm H • Fume Hood dimensions: 2010 mm WX 1000 mm D X 1555 mm H • Base Cabinetdimensions: 860 mm W X 600 mm D X 655 mm H • Inside Fume Hood working volume: 1740 mm W X 750mm D X 1180 mm H • Bed size: 1740 mm W X 750mm D • 230 V ±10%, 50 Hz, single phase • Powerconsumption: ~0.5–1.5 kW depending on model andblower size • Warranty minimum 12 months • Providingand fixing will be done by the bidder as per therequirement (all type of accessories and electricalcomponents) of lab. Make: Impact, Thermic, Kewaunee,Hemco, GD Waldner, ATL, Igene Lab Serve Type ofTesting: Bacteriological Testing (BT) and Waste WaterTesting (WWT) |
| 17 | BOD Incubator • Capacity: 171L • Volume: 6 Cu ftRefrigerated Insulation and Freezing in one unit. • PuffInsulated to keep the surface Temp. of body comfortableand avoid Cooling loss. • Silent energy savingKirloskar/ Tecumseh compressor, • Polish 304 grade S.Steel interior corrosion resistant long-life operationhaving adjustable shelves to make more space fordifferent Height. • Kanthal A-1 tubular heater is fittedfor better accuracy. • Safety Controller are providedwith the Digital Temperature Controller Cum Indicator.• Full features Touch Screen Controller • Inner glassdoor with Aluminium Frame Powder coated full viewdoor to observe the Test. • Angle Iron Frame at bottomwith castor wheel for easy movement. • Fitted with 2Nos. Fan (One for Cooling and One for Heating insidethe chamber) Technical Specification • TemperatureRange: 5°C- 60°C • Temperature Stability: ± 0.5°C Max • Material: GI Sheet with powder Coated • Inner:Stainless Steel 304 Grade • Safety Function: SafetyController for safety of Digital Temp. Controller CumIndicator and Cooling Compressor with MCB.Temperature Controller a. HMI Display with FeatherScreen Touch Digital Temperature Controller b.Continuous display of Temperature, Time, Day andDate Door Open Alarm c. Password Protected. d. Datatransfer port: USB port • Cooling: Fan Cooled, • Nominal Power: - 1/3 hp, • Voltage Range: - 187-264 V,Type CSR • Refrigerant: R134a • Along with installedUPS Battery/UPS System-2KVA • Included castorwheels for easy mobility of the equipment • Duty Cycle:Continuous • Along with NABL Calibration certificateMake: Ambassdor, Optics Technology, Impact,Thermic, NSW Type of Testing: Used forBacteriological Testing (BT) and Waste Water Testing(WWT) |
| 18 | Manifold Filtration Assembly • Branch - 6 Placeassemblies with High efficiency, High sensitivity andFast filtering speed • Funnel capacity- Minimum300mL. Filth pore size -Minimum 20µm • Funnelmaterial – All SS 316 within built SS Clamp and SS lidGlass or SS316 with external ss clamp and cork capacity250 ml • Vacuum flask 2L capacity • Valve - PTFE • Base holder – stainless steel 316L, Autoclavable-121°C (15min.) • Membrane filter 1 pack (100 No.) as perrequirement /0.45µm pack of 100 • With all accessories,flask, connectors • vacuum pump: air vent filterhydrophobic PTFE (Flow rate should be 19L/min.Motor speed -1400 rpm, Max vaccum-100 mbar) shouldbe of latest technology and highest quality. Make: PallLifesciences, Merck Millipore, Borosil, Labotronics,Athena, Axiva, Glassco Type of Testing: Used forBacteriological Testing (BT) |
| 19 | Ultra Water Purification Unit Water Purification Systemfor preparation of Mobile phase and standards withfollowing specifications • Type-1 water • Pre-filtrationsystem: Three stage pre-treatment system with: 10 µm sediment filter, 5 µm carbon filter and 1µm fine filter • 1 micron spun or provides pre-filtration with 10-micronfilters for removal of suspended particles and to takecare of F.I in water. • Resistivity: ) 1 MO.cm @ 25°C or in percentage • TOC: 5.0 ppb • Bacterial TVC: ( 1.0 cfu/ 100 mL • Microprocessor controlled managementsystems for continuous monitoring of water purity. • Should produce Ultra-Pure water (Type 1) from tapwater for different applications. • It should be singlestage system with the filter at the tap with bacteria andshould have RO, De-ionized water and UV in a singleunit. It should have an integrated docking vessel of 25 Lfor storing the water to save space It should haverecirculation facility to maintain consistent peak waterpurity. • Instrument should show water volume inreservoir graphically and in percentage. • It should havecartridge change indicator. The production rate of theunit should be minimum 6 Litre/hr or more and thedispense rate should be minimum 0.5 L/min or 1.0L/min. • It should have dual wavelength UV (185/254nm). • The manufacturer must have worldwide presence,also provide one spare cartridge. • Along withInstallation of 1 No R.O. system of Make (EurekaForbes, AO Smith, Livpure) with tank capacity of 15-20L. Make: Elga, Merck Millipore, Thermo Fischer Typeof Testing: Used for Chemical Testing (CT),Bacteriological Testing (BT) and Waste Water Testing(WWT) |
| 20 | All HSR Items Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender