Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #56377138

Bids Are invited for Repair And Maint Of Internal Electric Wiring And Repair To Air Conditioning System

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Jul 2026
10 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
337

Project Description

Bids Are invited for Repair And Maint Of Internal Electric Wiring And Repair To Air Conditioning System Taking Down Carefully Copper Aluminium Point - Taking Down Carefully Copper Aluminium Point Wiring Light Fan Bell Socket Or Power Complete Including Fixture And Fittings Such As Switches Ceiling Roses Pendents Regulators Sockets Light Fittings Etc Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit And Making Good Disturbed Surfaces Of Walls Floors Etc . Credit For Above Items Should Be Made As Per Conditions Separately. , Material And Labour For Point Wiring For Light Fan - Material And Labour For Point Wiring For Light Fan Bell With Frls Cable 1.5 Sqmm Pvc Insulated Red For Phase And Black For Neutral Unsheathed Multi Stranded Copper Conductor 1100 Volt Grade In And Incl Not Less Than 2Mm Thick Pvc Casing Caping Concealed With Pvc Conduit As Per Site Requirment With All Accessories And 1.50 Sqmm Green In Colour Pvc Copper Conductor Cable For Earth Continuity Connected To Common Earth Dolly Incl Pvc Box Surface Modular Sunken Box Type With Pvc Sheet For Mounting Fittings Such As Switches Sockets Fan Regulators Etc Complete All As Specified And Directed For One Light/Fan Bell Point Controlled By One Switch And Making Good To Disturbed Surface Of Wall Etc , Material And Labour Complete For Switch - Material And Labour Complete For Switch Piano Flush Button Single Pole One Way 16 240 Volts. , Material And Labour Complete For Socket - Material And Labour Complete For Socket Outlet 2 In 1 2 And 3 Pin 6 Piano Flush Type 240 Volts Complete All As Specified , Material And Labour Complete For Socket Outlet - Material And Labour Complete For Socket Outlet 2 In 1 3 Pin 6 And 16 Piano Flush Type 240 Volts Complete All As Specified , Material And Labour Complete For Switch Socket - Material And Labour Complete For Switch Socket Combination 5A 16 A 5 In 1 Flush Type 240 Volts Complete All As Specified , Supply And Fixing In Replacement - Supply And Fixing In Replacement 36 Watts Recess Pendant Mounting Ultraslim Led Flat Panel 2 X 2 Made Of Extruded Aluminium Frame With High Leds And Glare Free Opal Diffuser Ip20 Incl Taking Down Old Unsv. , Supply And Fixing Switch Modular - Supply And Fixing Switch Modular Piano Flush Button Single Pole One Way 6 S 1 Module With Suitable Plate And Cover Complete All As Specified And Directed. , Supply And Fixing Led Tube Light - Supply And Fixing Led Tube Light Fitting 1X18 20 Watt Wall Mounted Led Batten With Aluminum Housing And Integrated Electronic Driver Incl Taking Down Old Unsv. , Supply And Fixing Led Tube Light Fitting - Supply And Fixing Led Tube Light Fitting 1X10 Watt Wall Mounted Led Batten With Aluminum Housing And Integrated Electronic Driver Incl Taking Down Old Unsv. , Supply And Fixing 12 Watts Led Bulb - Supply And Fixing 12 Watts Led Bulb Complete All As Specified And Directed. , Supply And Fixing In Replacement Of Lam - Supply And Fixing In Replacement Of L Holder Angle Holder Insulated Body With Black White Plate For Batten Fittings Including Taking Down Unsv L Holder Complete All As Specified And Directed. , Supply And Fixing Of Powder Coated Pressure - Supply And Fixing Of Powder Coated Pressure Die Cast Aluminium Compact High Power Led Street Light Fittings With Heat Resistant Toughned Glass With Lense And Top Opening Having 60 Watt Including Making Electric Connections Using Two Run Of 1.5 Sqmm Single Core Unarmoured Wire From Junction Box Fixed In Repairs Complete All As Specified And As Directed. , Supply And Fixing In Replacement Mccb - Supply And Fixing In Replacement Mccb Having Current Ratings 63 S With Rupturing Cap 16 Ka Ac 415 Volts Three Pole All As Specified And Directed Including Dismentling The Existing U S Mccbs With All Connections And All As Required At Site Or Directed. , Supply And Fixing Rating - Supply And Fixing Rating 240V 10Ka C Curve Spn Miniature Circuit Breaker Mcb And 32 Current Carrying Capacity Complete With Connection Testing And Commissioning Including Taking Down Old Unsv Mcb Complete. , Supply And Fixing Rating 240V 10Ka - Supply And Fixing Rating 240V 10Ka C Curve Sp Miniature Circuit Breaker Mcb And 6 To 32 Current Carrying Capacity Complete With Connection Testing And Commissioning Including Taking Down Old Unsv Mcb Complete. , Supply And Fixing Exhaust Fan Steel Body - Supply And Fixing Exhaust Fan Steel Body Ac Single Phase. 230V Of Size 300Mm Sweep Heavy Duty With Blades Frame And Louvers Including Making Hole And Suitable Fixing Avoid Bird Entred From Outside Complete All As Specified And Directed , Supply And Fixing Mccb 4 Pole - Supply And Fixing Mccb 4 Pole 415 Volts Adjustable Type 200 S With Breaking Capacity 36 Ka Including Old Taking Dwon And Refixing With New Complete All As Specified Directed. , Material And Labour For Comprehensive Maintenece - Material And Labour For Comprehensive Maintenece And Servicing Of Split Type Air Conditioner/Window Type Unit Of Any Capacity Upto 2 Ton Outer And Inner Unit Both Of Any Make Including Cleaning The Dust From Body With Blower Cleaning Of Condenser And Cooling Coil Checking All Connections Including Functioning Of Metal Clad Socket Dp Switch Function Of Relay Capacitors Overload Protector Thermostat Fan Motor Fan Blower Drum Electronic Contol Box, Etc, , Replacement Of Old Unseviceable Damage - Replacement Of Old Unseviceable Damage Hermatic Sealed Compressor Unit With New Hermatic Sealed Unit 2 Ton Capacity And Any Specifications Including Taking Down Unsv Hermatic Sealed Unit Complete All As Specified And Directed. , Repalcement Of Old Unsv Damage Pcb With New - Repalcement Of Old Unsv Damage Pcb With New Pcb For Split Air Conditioner Of Capacity 2 Ton And Any Type Any Specification Including Taking Down Old Unsv Pcb Complete All As Specified And Directed. , Material And Labour For Detecting The Gas Leakage - Material And Labour For Detecting The Gas Leakage Rectifying The Defects Including Repair To Condensor Coil/Evaporator Coil By Means Of Welding Soldring Etc Vacumizing And Charging Topping Up Fresh Freon Gas And Commissioning And Testing For Split Type Window Type Ac All As Specified And Directed , Supply And Fixing Copper Pipe - Supply And Fixing Copper Pipe 1 4 And Also Removing Old Unsv Copper Pipe From Existing Split Acs Any Type Any Make Complete All As Specified And Direceted. , Repair Rewinding And Maint Of Voltage Stabilizer - Repair Rewinding And Maint Of Voltage Stabilizer Of Any Make And Capacity Up To 5 Kva After Disconnecting The Voltage Stabilizer From Machine Rewinding With Super Enamalled Copper Of Existing Gauge Including Replacement Of Unsv Part Like Voltmetre Metre Cut Out Relay Electric Circuit Indicator L Top Plug Flexible Wire Including Neccessary Painting With Two Coats Of Synthetic Enamel Paint After Proper Sctretching And Preparing The Surface Complete All As Specified And Directed. , Earthing Complete With Copper Earth Plate - Earthing Complete With Copper Earth Plate Electrode 60X60cmx3.15Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level Connected To Copper Strip 20X3mm As Earthing Lead By Means Of Bolts Nuts Check Nuts And Washers Of Copper Brazing All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point Including Pcc Earth Pit With Galavanised Pit Cover All As Specified Or Indicated Including Testing On Completion Total Quantity : 337

BOQ

Sl. No. Item TitleItem Description
1Taking down carefully copper aluminium pointTaking down carefully copper aluminium point wiring light fan bell socket or power complete including fixture and fittings such as switches ceiling roses pendents regulators sockets light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls floors etc . credit for above items should be made as per conditions separately.
2Material and Labour for point wiring for light fanMaterial and Labour for point wiring for light fan Bell with FRLS cable 1.5 sqmm PVC insulated red for phase and black for neutral unsheathed multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing caping concealed with PVC conduit as per site requirment with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface modular sunken box type with PVC sheet for mounting fittings such as switches sockets fan regulators etc complete all as specified and directed for one light/fan bell point controlled by one switch and making good to disturbed surface of wall etc
3Material and Labour complete for switchMaterial and Labour complete for switch piano flush button single pole one way 16 Amp 240 Volts.
4Material and Labour complete for socketMaterial and Labour complete for socket outlet 2 in 1 2 and 3 pin 6 Amp piano flush type 240 volts complete all as specified
5Material and Labour complete for socket outletMaterial and Labour complete for socket outlet 2 in 1 3 pin 6 Amp and 16 Amp piano flush type 240 volts complete all as specified
6Material and Labour complete for switch socketMaterial and Labour complete for switch socket combination 5A 16 A 5 in 1 flush type 240 volts complete all as specified
7Supply and fixing in replacementSupply and fixing in replacement 36 watts recess pendant mounting ultraslim LED flat panel 2 X 2 made of extruded aluminium frame with high LEDs and glare free opal diffuser IP20 incl taking down old UNSV.
8Supply and fixing Switch ModularSupply and fixing Switch Modular piano flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed.
9Supply and fixing LED tube lightSupply and fixing LED tube light fitting 1x18 20 watt wall mounted LED batten with aluminum housing and integrated electronic driver incl taking down old UNSV.
10Supply and fixing LED tube light fittingSupply and fixing LED tube light fitting 1x10 watt wall mounted LED batten with aluminum housing and integrated electronic driver incl taking down old UNSV.
11Supply and fixing 12 watts LED BulbSupply and fixing 12 watts LED Bulb complete all as specified and directed.
12Supply and fixing in replacement of lamSupply and fixing in replacement of lamp holder angle holder insulated body with black white plate for batten fittings including taking down unsv lamp holder complete all as specified and directed.
13Supply and fixing of Powder coated pressureSupply and fixing of Powder coated pressure die cast aluminium compact high power LED street light fittings with heat resistant toughned glass with lense and top opening having 60 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box fixed in repairs complete all as specified and as directed.
14Supply and fixing in replacement MCCBSupply and fixing in replacement MCCB having current ratings 63 Amps with rupturing cap 16 KA AC 415 Volts three pole all as specified and directed including dismentling the existing U S MCCBs with all connections and all as required at site or directed.
15Supply and fixing amp ratingSupply and fixing amp rating 240V 10KA C curve SPN miniature circuit breaker MCB and 32 Amp current carrying capacity complete with connection testing and commissioning including taking down old unsv mcb complete.
16Supply and fixing amp rating 240V 10KASupply and fixing amp rating 240V 10KA C curve SP miniature circuit breaker MCB and 6 to 32 Amp current carrying capacity complete with connection testing and commissioning including taking down old unsv mcb complete.
17Supply and fixing exhaust fan steel bodySupply and fixing exhaust fan steel body AC single Phase. 230V of size 300mm sweep heavy duty with blades frame and louvers including making hole and suitable fixing avoid bird entred from outside complete all as specified and directed
18Supply and fixing MCCB 4 PoleSupply and fixing MCCB 4 Pole 415 Volts Adjustable type 200 Amps with breaking capacity 36 KA including old taking dwon and refixing with new complete all as specified directed.
19Material and Labour for comprehensive mainteneceMaterial and Labour for comprehensive maintenece and servicing of Split type Air conditioner/Window type unit of any capacity upto 2 TON outer and inner unit both of any make including cleaning the dust from body with blower cleaning of condenser and cooling coil checking all connections including functioning of metal clad socket DP switch function of relay capacitors overload protector thermostat fan motor fan blower drum electronic contol box, etc,
20Replacement of old unseviceable damageReplacement of old unseviceable damage hermatic sealed compressor unit with new hermatic sealed unit 2 Ton capacity and any specifications including taking down unsv hermatic sealed unit complete all as specified and directed.
21Repalcement of old unsv damage PCB with newRepalcement of old unsv damage PCB with new PCB for split air conditioner of capacity 2 ton and any type any specification including taking down old unsv PCB complete all as specified and directed.
22Material and Labour for Detecting the gas leakageMaterial and Labour for Detecting the gas leakage rectifying the defects including repair to condensor coil/evaporator coil by means of welding soldring etc vacumizing and charging topping up fresh freon Gas and commissioning and testing for split type window type AC all as specified and directed
23Supply and fixing copper pipeSupply and fixing copper pipe 1 4 and also removing old unsv copper pipe from existing split ACs any type any make complete all as specified and direceted.
24Repair rewinding and maint of voltage stabilizerRepair rewinding and maint of voltage stabilizer of any make and capacity up to 5 KVA after disconnecting the voltage stabilizer from machine rewinding with super enamalled copper of existing gauge including replacement of unsv part like voltmetre Amp metre cut out relay electric circuit indicator lamp Top plug flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface complete all as specified and directed.
25Earthing complete with copper earth plateEarthing complete with copper earth plate electrode 60X60cmX3.15mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 1.5 metres below normal ground level connected to copper strip 20X3mm as earthing lead by means of bolts nuts check nuts and washers of copper brazing all as shown in electrical plate No. 3 connected to earthing test point including PCC earth pit with galavanised pit cover all as specified or indicated including testing on completion

AI Tender Summary

OUR REF NO 56377138
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 21-07-2026
Authority
Authority Name Indian Army
Work Description Bids Are invited for Repair And Maint Of Internal Electric Wiring And Repair To Air Conditioning System Taking Down Carefully Copper Aluminium Point - Taking Down Carefully Copper Aluminium Point Wiring Light Fan Bell Socket Or Power Complete Including Fixture And Fittings Such As Switches Ceiling Roses Pendents Regulators Sockets Light Fittings Etc Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit And Making Good Disturbed Surfaces Of Walls Floors Etc . Credit For Above Items Should Be Made As Per Conditions Separately. , Material And Labour For Point Wiring For Light Fan - Material And Labour For Point Wiring For Light Fan Bell With Frls Cable 1.5 Sqmm Pvc Insulated Red For Phase And Black For Neutral Unsheathed Multi Stranded Copper Conductor 1100 Volt Grade In And Incl Not Less Than 2Mm Thick Pvc Casing Caping Concealed With Pvc Conduit As Per Site Requirment With All Accessories And 1.50 Sqmm Green In Colour Pvc Copper Conductor Cable For Earth Continuity Connected To Common Earth Dolly Incl Pvc Box Surface Modular Sunken Box Type With Pvc Sheet For Mounting Fittings Such As Switches Sockets Fan Regulators Etc Complete All As Specified And Directed For One Light/Fan Bell Point Controlled By One Switch And Making Good To Disturbed Surface Of Wall Etc , Material And Labour Complete For Switch - Material And Labour Complete For Switch Piano Flush Button Single Pole One Way 16 240 Volts. , Material And Labour Complete For Socket - Material And Labour Complete For Socket Outlet 2 In 1 2 And 3 Pin 6 Piano Flush Type 240 Volts Complete All As Specified , Material And Labour Complete For Socket Outlet - Material And Labour Complete For Socket Outlet 2 In 1 3 Pin 6 And 16 Piano Flush Type 240 Volts Complete All As Specified , Material And Labour Complete For Switch Socket - Material And Labour Complete For Switch Socket Combination 5A 16 A 5 In 1 Flush Type 240 Volts Complete All As Specified , Supply And Fixing In Replacement - Supply And Fixing In Replacement 36 Watts Recess Pendant Mounting Ultraslim Led Flat Panel 2 X 2 Made Of Extruded Aluminium Frame With High Leds And Glare Free Opal Diffuser Ip20 Incl Taking Down Old Unsv. , Supply And Fixing Switch Modular - Supply And Fixing Switch Modular Piano Flush Button Single Pole One Way 6 S 1 Module With Suitable Plate And Cover Complete All As Specified And Directed. , Supply And Fixing Led Tube Light - Supply And Fixing Led Tube Light Fitting 1X18 20 Watt Wall Mounted Led Batten With Aluminum Housing And Integrated Electronic Driver Incl Taking Down Old Unsv. , Supply And Fixing Led Tube Light Fitting - Supply And Fixing Led Tube Light Fitting 1X10 Watt Wall Mounted Led Batten With Aluminum Housing And Integrated Electronic Driver Incl Taking Down Old Unsv. , Supply And Fixing 12 Watts Led Bulb - Supply And Fixing 12 Watts Led Bulb Complete All As Specified And Directed. , Supply And Fixing In Replacement Of Lam - Supply And Fixing In Replacement Of L Holder Angle Holder Insulated Body With Black White Plate For Batten Fittings Including Taking Down Unsv L Holder Complete All As Specified And Directed. , Supply And Fixing Of Powder Coated Pressure - Supply And Fixing Of Powder Coated Pressure Die Cast Aluminium Compact High Power Led Street Light Fittings With Heat Resistant Toughned Glass With Lense And Top Opening Having 60 Watt Including Making Electric Connections Using Two Run Of 1.5 Sqmm Single Core Unarmoured Wire From Junction Box Fixed In Repairs Complete All As Specified And As Directed. , Supply And Fixing In Replacement Mccb - Supply And Fixing In Replacement Mccb Having Current Ratings 63 S With Rupturing Cap 16 Ka Ac 415 Volts Three Pole All As Specified And Directed Including Dismentling The Existing U S Mccbs With All Connections And All As Required At Site Or Directed. , Supply And Fixing Rating - Supply And Fixing Rating 240V 10Ka C Curve Spn Miniature Circuit Breaker Mcb And 32 Current Carrying Capacity Complete With Connection Testing And Commissioning Including Taking Down Old Unsv Mcb Complete. , Supply And Fixing Rating 240V 10Ka - Supply And Fixing Rating 240V 10Ka C Curve Sp Miniature Circuit Breaker Mcb And 6 To 32 Current Carrying Capacity Complete With Connection Testing And Commissioning Including Taking Down Old Unsv Mcb Complete. , Supply And Fixing Exhaust Fan Steel Body - Supply And Fixing Exhaust Fan Steel Body Ac Single Phase. 230V Of Size 300Mm Sweep Heavy Duty With Blades Frame And Louvers Including Making Hole And Suitable Fixing Avoid Bird Entred From Outside Complete All As Specified And Directed , Supply And Fixing Mccb 4 Pole - Supply And Fixing Mccb 4 Pole 415 Volts Adjustable Type 200 S With Breaking Capacity 36 Ka Including Old Taking Dwon And Refixing With New Complete All As Specified Directed. , Material And Labour For Comprehensive Maintenece - Material And Labour For Comprehensive Maintenece And Servicing Of Split Type Air Conditioner/Window Type Unit Of Any Capacity Upto 2 Ton Outer And Inner Unit Both Of Any Make Including Cleaning The Dust From Body With Blower Cleaning Of Condenser And Cooling Coil Checking All Connections Including Functioning Of Metal Clad Socket Dp Switch Function Of Relay Capacitors Overload Protector Thermostat Fan Motor Fan Blower Drum Electronic Contol Box, Etc, , Replacement Of Old Unseviceable Damage - Replacement Of Old Unseviceable Damage Hermatic Sealed Compressor Unit With New Hermatic Sealed Unit 2 Ton Capacity And Any Specifications Including Taking Down Unsv Hermatic Sealed Unit Complete All As Specified And Directed. , Repalcement Of Old Unsv Damage Pcb With New - Repalcement Of Old Unsv Damage Pcb With New Pcb For Split Air Conditioner Of Capacity 2 Ton And Any Type Any Specification Including Taking Down Old Unsv Pcb Complete All As Specified And Directed. , Material And Labour For Detecting The Gas Leakage - Material And Labour For Detecting The Gas Leakage Rectifying The Defects Including Repair To Condensor Coil/Evaporator Coil By Means Of Welding Soldring Etc Vacumizing And Charging Topping Up Fresh Freon Gas And Commissioning And Testing For Split Type Window Type Ac All As Specified And Directed , Supply And Fixing Copper Pipe - Supply And Fixing Copper Pipe 1 4 And Also Removing Old Unsv Copper Pipe From Existing Split Acs Any Type Any Make Complete All As Specified And Direceted. , Repair Rewinding And Maint Of Voltage Stabilizer - Repair Rewinding And Maint Of Voltage Stabilizer Of Any Make And Capacity Up To 5 Kva After Disconnecting The Voltage Stabilizer From Machine Rewinding With Super Enamalled Copper Of Existing Gauge Including Replacement Of Unsv Part Like Voltmetre Metre Cut Out Relay Electric Circuit Indicator L Top Plug Flexible Wire Including Neccessary Painting With Two Coats Of Synthetic Enamel Paint After Proper Sctretching And Preparing The Surface Complete All As Specified And Directed. , Earthing Complete With Copper Earth Plate - Earthing Complete With Copper Earth Plate Electrode 60X60cmx3.15Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Metres Below Normal Ground Level Connected To Copper Strip 20X3mm As Earthing Lead By Means Of Bolts Nuts Check Nuts And Washers Of Copper Brazing All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point Including Pcc Earth Pit With Galavanised Pit Cover All As Specified Or Indicated Including Testing On Completion Total Quantity : 337
Basic Detail
Tender No GEM/2026/B/7745997
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 09 Jul 2026
Submission Date 21 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
eeee76f0-6d19-455d-ab7a-38c797d3c37b.pdf
9560248_Boq_1.xlsx
jobacwir_2026-07-04-14-00-08_8eea9cb7d3aa7dc68162f06d6263c130.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

eeee76f0-6d19-455d-ab7a-38c797d3c37b.pdf

xlsx

9560248_Boq_1.xlsx

pdf

jobacwir_2026-07-04-14-00-08_8eea9cb7d3aa7dc68162f06d6263c130.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender