Tender For Annual Rate Contract For Repairs And Maintenance Of 33/11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division Sopore (District Baramulla And Kupwara) For The Year 2026-27 Or Till Next Rate Contract Is Finalized
Tender Overview
Project Description
Tender for Annual Rate Contract For Repairs And Maintenance Of 33/11Kv Receiving Stations Falling Under The Jurisdiction Of Sub Transmission Division Sopore (District Baramulla And Kupwara) For The Year 2026-27 Or Till Next Rate Contract Is Finalized
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 12KV, 1250 A,12kA-3 Sec 11 KV Vaccum Circuit Breaker (Only Breaker) suitable for VCB Panels of Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal or equivalent of reputed make |
| 2 | Supply, Carriage upto site (including Loading/Unloading),Testing of 33 kV Current Transformer (33 kV, 1Φ, 2 Ratio 3 Core, Outdoor) (600-300/5-5,400-200/5-5A,300-150/5-5 A as per the requirement) (reputed make) |
| 3 | Installation & Commissioning of 33 kV Current Transformer (33 kV, 1Φ, 2 Ratio 3 Core, Outdoor) as per approved standards |
| 4 | Supply, Carriage upto site (including Loading/Unloading),Testing of 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor) (reputed make) |
| 5 | Installation & Commissioning of 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor) as per approved standards |
| 6 | Supply, Carriage upto site (including Loading/Unloading),Testing of 12 KV, Two Core,Indoor Epoxy Resin Cast Current Transformer suitable for ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal or equivalent) of CTR (750-350/5-5; 600-300/5-5A, 400-200/5-5A, 100-50/5-5 as per the requirement) (reputed make) |
| 7 | Installation & Commissioning of 11kV Voltage Transformer (11kV/ 110 V, 3Φ), including loading from store, carriage upto site and un-loading at site as per approved standard. |
| 8 | Supply, Carriage upto site (including Loading/Unloading),Testing of 11kV/ 110 V, Three phase epoxy resin cast Voltage Transformer with rated burden 15VA per phase and accuracy class 0.5 suitable for ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal or equivalent) (reputed make) |
| 9 | Installation & Commissioning of 12 KV, Two Core,Indoor Epoxy Resin Cast Current Transformer Volts Voltage Transfomer including loading from store, carriage upto site and un-loading at site as per approved standard. |
| 10 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioining of Panel spouts Bushing suitable for 11KV VCB ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal or equivalent) |
| 11 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & CommissioiningInterrupting chambers (Housing Assembly) suitable for 11KV VCB of different make ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal) |
| 12 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioining of Complete Charging/ Gear Mechanism suitable for 11KV VCB of different make ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal etc.) |
| 13 | Supply, Carriage upto site (including Loading/Unloading),& Testing of Charging Gears (Big)for 11 KV VCB ( Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal |
| 14 | Supply, Carriage upto site (including Loading/Unloading),& Testing of Charging Gears (Small) for 11 KV VCB Allind,Vijay,Crompton greeves,Easun Reyroll,Alasthom, Electricfield,Sudhir,ABB,L&T, Pascal or equivalent) |
| 15 | Installation of Charging Gears (Big/Small) |
| 16 | Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioining of Chemical Earthing (50mm dia G.I Pipe with Chemical bags) |
| 17 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioining of 11/33 KV VCB 110 V Charging Motor suitable for 33 KV VCB of different make (Crompton Greeves /ABB/Stelmac or equivalent) |
| 18 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioining of 1.5 Sqmm 1-C PVC Flexible wire (Vguard/Havells/Polycab/) |
| 19 | Supply, Carriage upto site (including Loading/Unloading),Testing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm |
| 20 | Supply, Carriage upto site (including Loading/Unloading),Testing of 33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less |
| 21 | Supply, Carriage upto site (including Loading/Unloading),Testing of 33KV Post Insulators (porceline type) |
| 22 | Supply ,Carriage upto site (including Loading/Unloading),installation, testing and commissioning of 36V,200 AH Maintenance free Battery Bank ( comprising of 18 number batteries of 2volt each) complete with rack ,connectors etc conforming to IEC60896-21/22 standards of Exide/HBL/AMAR Raja or equivalent make |
| 23 | Supply,Carriage upto site (including Loading/Unloading),installation,testing and commissioning of automatic 36v, Float‐Cum‐Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply . Copper wound suitable for 100 to 200 AH |
| 24 | Supply, Carriage upto site (including Loading/Unloading),Testing of Shower Contacts for 11 KV VCB (Allind-Make/ Easun / S&S / Crompton / Alastrom ) |
| 25 | Supply, Carriage upto site (including Loading/Unloading),Testing of Shower Contacts for 11 KV VCB (Electric Field or equivalent) |
| 26 | Installation & Commissioning of Shower Contacts for 11 KV VCB as per approved standards |
| 27 | Supply, Carriage upto site (including Loading/Unloading),Testing & Installation of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm of reputed make |
| 28 | Supply, Carriage upto site (including Loading/Unloading),Testing & Installation of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm with fitting of reputed make |
| 29 | Supply, Carriage upto site (including Loading/Unloading),Fabrication, Testing, Installation of G.I Channel / Angle/ Flat /V X Arm /Clamps of various sizes as per approved drawings/standards |
| 30 | Supply, Carriage upto site and Fixing of 1200 Watt Heat Pillar (Havells/Usha/Bajaj Make) |
| 31 | Supply, Carriage upto site (including Loading/Unloading),Testing & Installation of Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories as per KPDCL standards |
| 32 | Supply, Carriage upto site (including Loading/Unloading),Testing & Installation of Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories as per KPDCL standards |
| 33 | Supply, Carriage upto site (including Loading/Unloading), of Alumunium Ladder 2*20 ' (Extendable with rope and pulley arrangement) 3 mm Thick |
| 34 | Supply, Carriage upto site (including Loading/Unloading), Installation and commissioning of Digital Ammeter 3-Phase of reputed make |
| 35 | Supply, Carriage upto site (including Loading/Unloading), Installation and commissioning of Digital Voltmeter 3-Phase of reputed make |
| 36 | Supply, Carriage upto site (including Loading/Unloading), Installation and commissioning of Silica-Gel Breather suitable for 33/11kV Power transformers |
| 37 | Replacement of of Silica Gel from existing breather (including cost of silica gel) |
| 38 | Supply, carriage, installation, testing and commissioning of EF/OC Numerical Relay (IEC 61850) with RS port 485 (SCADA compatible) of reputed make |
| 39 | Supply, carriage, installation, testing and commissioning of Master Trip Relay of reputed make Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender