Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #56373096

Tender For Repairs/Replacement Of Internal Wiring, Fittings, Fixtures, Ug Cables, Lt Electrical And Allied Services At Af Stn Suryalanka

Issued by Statutory Bodies & Commissions/Committees · Guntur, Andhra Pradesh
Tender Value
32.94 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
21 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Guntur → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs/Replacement Of Internal Wiring, Fittings, Fixtures, Ug Cables, Lt Electrical And Allied Services At Af Stn Suryalanka

BOQ

Name of Work:- Repairs/Replacement of Internal wiring, fittings, fixtures, UG cables, LT Electrical and Allied Services at AF Stn Suryalanka
Sl. No. Item Description
1M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed/surface PVC conduit, making good with chasing, chipping, applying cement, fitting and accessories, joints boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth for one light point/one fan point/one buzzer point controlled by one switch complete all as specified and as directed including taking down existing point wiring any type.
2M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed/surface PVC conduit, making good with chasing, chipping, applying cement, fitting and accessories, joints boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth for one 3 pin socket outlet 5 amps, independent complete all as specified and as directed including taking down existing point wiring any type.
3M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed/surface PVC conduit, making good with chasing, chipping, applying cement, fitting and accessories, joints boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth for one 3 pin socket outlet 5 amps, on same board controlled by one switch complete all as specified and as directed including taking down existing point wiring any type.
4M&L for point wiring complete with 4.0 Sqmm single core multistranded copper conductor, FRLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed/surface PVC conduit, making good with chasing, chipping, applying cement, fitting and accessories, joints boxes including one 4.0 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth for one 3 pin socket outlet 15 amps, independent complete all as specified and as directed including taking down existing point wiring any type.
5S&F in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
6S&F in repairs modular switch one way 16 Amps, 1 module complete all as specified and as directed.
7S&F in repairs modular socket 6A, 2/3 pin combined 2 module complete all as specified and as directed.
8S&F in repairs modular socket 6A/16A, 2/3 pin combined 2 module complete all as specified and as directed.
9S&F in repairs of modular Fan regulator electronic step type, 100W- 2 module, 240V single phase complete all as specified and as directed.
10S&F in repairs of Modular Bell Push 6/10 Amps, 01 Module complete all as specified and as directed.
11S&F in repairs switch flush type one way 6 Amps, complete all as specified and as directed.
12S&F in repairs of stepped type electronic Fan regulator flush type , 120W 240V single phase complete all as specified and as directed.
13S&F in repairs flush type switch socket combination 2 in 1, 3 pin, 6A complete all as specified and as directed.
14S&F in repairs flush type switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed.
15S&F in repairs of flush type Bell Push 5/6 Amps, complete all as specified and as directed.
16S&F in repairs of 230 Volts, AC, Bell Ding-Dong complete all as specified and as directed.
17S&F in repairs modular white cover plate with frame, 2 module complete all as specified and as directed.
18S&F in repairs modular white cover plate with frame, 3 module complete all as specified and as directed.
19S&F in repairs modular white cover plate with frame, 4 module complete all as specified and as directed.
20S&F in repairs modular white cover plate with frame, 6 module complete all as specified and as directed.
21S&F in repairs modular white cover plate with frame, 8 module complete all as specified and as directed.
22S&F in repairs modular metal flush box, 2 module complete all as specified and as directed.
23S&F in repairs modular metal flush box, 3 module complete all as specified and as directed.
24S&F in repairs modular metal flush box, 4 module complete all as specified and as directed.
25S&F in repairs modular metal flux box, 6 module complete all as specified and as directed.
26S&F in repairs modular metal flux box, 8 module complete all as specified and as directed.
27S&F in repairs ceiling rose, 3 plate PVC/polycarbonate, isolated body complete all as specified and as directed.
28S&F in repairs submain wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, making good with chasing, chipping, applying cement, fixed on/in wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed.Note: 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
29S&F in repairs submain wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, making good with chasing, chipping, applying cement, fixed on/in wall, ceiling including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing submain wiring complete all as specified and as directed.Note: 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
30S&F in repairs LED Bldg security light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete IP 65/66 protection complete to be fixed on wall including connecting cable, making good disturbed surface complete all as specified and as directed.
31M&L in repairs for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI wire 4 mm dia by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 15 mm bore as protection pipe, GI wire of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance n.exc. 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
32S&F 4 Feet LED Tube light of 20 Watt 6500 K Batten with integrated electronic driver with necessary fixing screws, and connected upto ceiling rose including taking down existing UNSV tube light fitting of any type and making Good complete all as specified and as directed.
33S&F 2 Feet LED Tube light of 10 Watt 6500 K Batten with integrated electronic driver with necessary fixing screws, and connected upto ceiling rose including taking down existing UNSV tube light fitting of any type and making Good complete all as specified and as directed.
34S&F in replacement of any type of light fitting with LED luminaire 600mmx600mm, 36 Watt, 220V AC recessed type with high efficiency glare free light complete with driver, including connecting cable for fixing in place of existing light and necessary addition/ alternation to fix new light in place of unsv light complete all as specified and as directed.
35S&F in repair MCB DB Double Door, SPN 8 way IP 54, fixed to wall in concealed by disturbing the existing wall surface and making good complete all as specified and as directed.
36S&F in repair MCB DB Double Door, TPN 4 Way IP 54, fixed to wall in concealed by disturbing the existing wall surface and making good complete all as specified and as directed.
37S&F in replacement of MCB, Single pole 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
38S&F in replacement of MCB, Single pole 40 Amps, C Curve, 10 kA, Complete all as specified and as directed.
39S&F in replacement of MCB, Four Pole 40 - 63 Amps, C Curve Complete all as specified and as directed.
40S&F in replacement two pin and earth Metal clad plug and socket with MCB SP 20Amps, complete all as specified and as directed.
41S&F in replacement of cable with copper conductor PVC round sheathed (flexible) industrial cable 1.5 Sqmm 3 core complete all as specified and as directed.
42S&F in replacement of cable with copper conductor PVC round sheathed (flexible) industrial cable 4 Sqmm 3 core complete all as specified and as directed.
43S&F in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
44S&F in replacement of LT junction box outdoor, single door opening front side with caldron sliding locking arrangement suitable size make out of CRCA Sheet of 3.15 mm thick with powder coated painting, frame made out of flat iron 45 x 45 x 6 mm and four numbers of 100 Amps aluminum bars duly insulated on insulators / suitable size Bakelite sheet fixed horizontally including making necessary drilling on bus bars for fixing of out going cable upto 95 Sqmm XLPE - 05 Nos with minimum gap as per IE standards and one No MCCB of capacity 63 A, 4 Pole, 415 V 25 KA complete ( free space between MCCB / busbar and other connection items should be provided,) including removing of existing Jn box and excavation work and fixing arrangement on ground by using suitable type of PCC, nuts & bolts, danger notice sticker, cable glands, internal wiring with FRLS copper cable of suitable size complete all as specified and as directed.Note : Before placing the order the contractor shall submit the Drg for approval of AGE(I)
45Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 150 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring with FRLS copper wires, including taking down old UNSV LT panel and including the following Note : Before placing the order the contractor shall submit the Drg for approval of AGE(I) Incoming: a) Onload change Over 4 Pole, 100 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.b) MCCB 4 Pole, 100 Amps, 36 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.Outgoing: a) MCCB 3 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01b) MCB TPN 32 Amp, 10 kA . - 04 No.c) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs d) LED indicating lamps with colour Red, Yellow, Blue - 01 Set(e) Capacitor bank 5KVAR - 01 with APFC relay and necessary control like contacts etcf) Street light timer with contacts 3 Ph - 02 Nos
46M&L for fixing of MCCB 415 V, 16 KA, 3 Pole 63 A to 100 Amps including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, screwing, connector (links) of suitable size to connect the MCCB with bus bar, thimble of suitable size, nuts & bolts, extended links etc complete required for fixing the new one in existing location complete all as specified and as directed
47All as per item No 46 above but capacity 125 Amps 16 KA
48All as per item No 46 above but capacity 160 Amps 36 KA
49All as per item No 46 above but capacity 250 Amps 36 KA
50M&L for MCB TP of capacity 32 Amp 10 KA including taking down old burn out MCB and making necessary arrangement for fixing the new one and connecting the cable complete all as specified and as directed
51Supply, installation, commissioning and testing of LT Feeder Pillar Box outdoor type, double door made out of CRCA Sheet of 3.15 mm thick with powder coated painting and four numbers of 100 Amps aluminum strips / bars duly insulated on insulators / suitable size Bakelite sheet, free space between MCCB / busbar and other connection items should be provided as per latest IE, the space between ground to panel should be 20 cm with PCC foundation for LT Panel, LT panel should be provided with necessary locking arrangement, danger notice sticker, cable glands, suitable size of lugs to connect cable to the panel I/C and O/G, internal wiring FRLS Copper cable, including taking down old UNSV LT panel and including the following Note : Before placing the order the contractor shall submit the Drg for approval of AGE(I)Incoming:a) MCCB 4 Pole, 63 Amps, 25 kA, Adjustable thermal and adjustable magnetic setting. - 01 No.Outgoing: a) MCB TPN 40/32 Amps - 6 Nosb) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTsc) LED indicating lamps with colour Red, Yellow, Blue - 01 Set
52M&L for painting LT Panel/Feeder pillar/Jn boxes of any size by rubbing/ scrapping old surface with one coat of red oxide and two coats of synthetic enamel paint including repair/replacement of hinges of suitable size and external locking arrangements i.e. sliding bolts by screwing/welding, tinkering works and complete all as specified and as directed.
53S&F In repair 10 Sqmm PVC Insulated Single Core Unsheathed Industrial Flexible copper Cable conforming to IS 694:1990 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volts along with Copper lugs and fixed complete all as specified and as directed.
54M&L for fixing the Aluminium lugs of size 25 to 70 Sqmm including preparation of cable by cutting trimming burnout cable complete all as specified and as directed.
55All as per item no 54 above but size 95 to 240 Sqmm
56M&L in repair for Earthing complete with earth galvanized steel plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with galvanized earth lead GI strip 32X6 by means of bolts, check nut and washers of GI or steel, GI pipe light grade of 40 mm bore as protection pipe, GI strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia medium grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
57S&F in replacement Street light timer analog clock type 3 module with battery backup, programmable for every 15 Min, and connected to existing power contact for controlling street light including necessary arrangements for fixing of new timer at existing location by making necessary arrangement and taking down old timer complete all as specified and as directed.
58S&F in replacement of Power Contactor of 3 Phase, 40 Amps, 4 Pole, 2 No + 2 NC in existing Street light panel and connection with bus bar / cable with copper wire of suitable size including necessary arrangements like cutting, screwing and threading to fix new contactor in place of existing and removing the old contactor complete all as specified and as directed
59S&F In repair 1.5 Sqmm PVC Insulated 3 Core Unsheathed Industrial Flexible Cable to connect Jn box to end connection conforming to IS 694:1990 with Flexible Bright Annealed Copper Conductor for Voltage Grade 1100 Volts along with Copper lugs in PVC conduit of suitable size but not less than 20 mm and fixing arrangement on pole complete all as specified and as directed.
60M&L for Dismantling of existing ACSR conductor of any size type for repair/replacement of insulators/channels/ACSR conductor complete all as specified and as directed
61M&L for Dismantling of existing Pin insulator and fixing new PIN insulator of 1100 Voltage grade, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and as directed.
62M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including for Dismantling of existing Cross arms on existing LT poles complete all as specified and as directed.
63S&F of ACSR conductor of any size type for on pole complete all as specified and as directed.
64S&F in replacement of existing loop in-out junction box with non metallic PVC junction box suitable of size 350 x 250 x 150 with connector 4 way and including one MCB SP 6 A, 230V alongwith, 2 Nos cable glands of size n.exc. 4 core 25 sqmm, Cable lugs, glands , aluminium clamps of suitable size to fix the PVC box on pole including excavation for the loop cable remove burnt cable and refix the same cable after necessary preparation of unburnt cable for connection, refilling and nuts and bolts as required complete all as specified and as directed.
65Supply and laying in trenches or passing through pipe, fixed to wall/pole and duct etc LT underground electric cable including jointing by using lugs, glands etc and testing XLPE insulated armoured heavy duty underground cable 10 Sqmm, 2 core with stranded aluminium conductor 1100 volt grade including taking down unserviceable cable all as specified and as directed.
66All as per item no. 65 here-in-above but for 16 sqmm, 4 core cable
67All as per item no. 65 here-in-above but for 25 sqmm, 3.5 core cable
68All as per item no. 65 here-in-above but for 35 sqmm, 3.5 core cable
69All as per item no. 65 here-in-above but for 50 sqmm, 3.5 core cable
70All as per item no. 65 here-in-above but for 70 sqmm, 3.5 core cable
71All as per item no. 65 here-in-above but for 95 Sqmm 3.5 Core cable
72All as per item no. 65 here-in-above but for 120 Sqmm 3.5 Core cable
73All as per item no. 65 here-in-above but for 240 Sqmm 3.5 Core cable
74M&L for cable jointing kit out door type for 1.1 KV cable for Straight through heat shrink type complete with jointing materials and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable 95 to 70 Sqmm, 3.5 core including find the fault excavation/returning & refilling of loop excavation complete all as specified and as directed
75All as per item no. 74 here-in-above but for 50 to 25 Sqmm, 3.5 core cable
76Excavation in trenches, in soft/loose soil n.exc. 1.5m deep and n.exc. 1.5m wide for laying of cable, RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and as directed.
77Returning, filling-in, including spreading, watering and well ramming in layers n.exc. 25 cm thick each, in soft /loose soil complete all as specified and as directed.
78M&L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and as directed.Note :- Punned down thickness shall be measured for payment
79M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed.
80M&L for removing excavated material (soil) n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting complete all as specified and as directed.
81Supply and laying galvanised steel tubing 40 mm dia, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes complete all as specified and as directed.
82S&F OFF LOAD change over switch 415 V in sheet metal enclosure 4 pole of capacity 63 Amps fixed on wall complete all as specified and as directed.
83S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 10 Sqmm including taking down old unsv service cable complete all as specified and as directed.
84All as per item no 85 here-in-before but size 6 Sqmm including taking down old unsv service cable complete all as specified and as directed.
85All as per item no 85 here-in-before but size 4 Sqmm including taking down old unsv service cable complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56373096
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 32.94 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs/Replacement Of Internal Wiring, Fittings, Fixtures, Ug Cables, Lt Electrical And Allied Services At Af Stn Suryalanka
Basic Detail
Tender No 82672/E8
Bidding Type Tender
Location
City Guntur
State Andhra Pradesh
Key Dates
Publish Date 09 Jul 2026
Submission Date 30 Jul 2026
Open Date 01 Aug 2026
Finance
Tender Value 32.94 Lakhs
Tender Fee 500
EMD 66000
Exemption Available
Document List
889d2fd8-867c-4327-8813-849c032d993c.html
BOQ_870571.xls
Tenderdocmerged.pdf
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

889d2fd8-867c-4327-8813-849c032d993c.html

xls

BOQ_870571.xls

pdf

Tenderdocmerged.pdf

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender