Tender for Renovation Work At Sub Division Deogarh

BOQ

Name of Work:- Renovation work at Sub division Deogarh
Sl. No. Item Description
1Building Items (Part A)
2Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding NOld work (one or more coats) including scrapping surface and necessary repairs. (a) Colour Change r
3Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding:
4Painting exterior surface of wall with 100% acryic exterrior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand parering prime putty etc complete in all respect old work
5Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work.
6Painting with enamel paint of app brand and manufacturer to give an even shade two ro more coat on new work
7Plaster on new surface on walls in cement sand mortar 1 : 6 including raking of joints etc. complete fine finished : 20 mm thick
8P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of pproved make in all colour and shade, laid with 20 mm thick CM 1 : 4 includinggrounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm
9Add extra for Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 , using 5kg. adhesive per sqm of tile area, in average 3mm thickness instead of cement mortar.
10Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mm thick with 20mm thick nominal size aggregate
11Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts& screw etc
12Providing and Fixing2nd ist quality standard white/ivory, grey, fuma red brown, light green, light blue and other light shades glazed tiles of ISI marked (IS:13753) of size 300 mm x 200 mm in walls, floors, steps, pillars etc. laid on a bed of neat cementslurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillar):
13Providing and fixing iind quality MAT finished ceremic tiles size 300x300 mm confirming to IS 13753 colour such as white, grey, lvory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder (untile or roffe make)and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4). 20mm thick
14Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats)
15Renewing glass panes, with putty and nails whenever necessary : Float glass panes of thickness 4 mm
16Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20mm
17Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
18Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone
19Kota stone slab flooring 25 mm thick over 20 mm (average)thick base laid over and jointed with grey cement slurrymixed with pigment to match the shade of the slab includingrubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm
20Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, boltsand nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required0.80 mm thick with zinc coating not less than 275 gm/m2
21Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast andfittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide Kg. 96.009.8.1 Extra if square,rectangular hollow tubelar sections are used or grill made by flats only
22Providing & fixing external grade board solid core single lef flush door shutters ISI 2200-67 mark using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure ‘A’Decorative teak veneer One side
23Providing and fixing T-iron frames for doors windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs: 10 cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size)or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
24Random Rubble stone masonry with hard stone insuperstructure above plinth level and upto five level above30cm. thick walls in Cement Mortar 1:6 ( 1-Cement : 6-Sand):
25Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand)
26Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil
27Providing and laying in position cement conrete including curing compaction etc. Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 cement: 4 coarse sand:8 graded stone aggregate 40 mm nominal size)
28Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand).
29Providing and fixing M.S. sheet 1mm thick single leaf doorshutter in angle iron frame 35x35x5mm suitabilly diagonallybraced with 25x3mm flat iron above and below lock rail ofsize 50x5mm beading extra including all fittings, as perdirection of Engg. incharge but excluding cost of chowkhats:including two coats of anit-corrosive red oxide primer paint
30Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twinpeg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting inapproved shade with deco paint of approved quality complete as per direction of Engineer In Charge
31Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Shuttering Ply - 9mm thick (Commercial)
32Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Wire Gauge 14 mesh x 24 gauge
33Repair of door, window shutters including cost of material and labour for change of damaged :Panel by Plain Glass Panes 4mm thick
34Repair of door, window shutters including cost of material and labour for change of damaged :Aldrop of mild Steel12\\" long x12mm dia
35Repair of door, window shutters including cost of material and labour for change of damaged :Stopper of Aluminium with Double Rubber Gutka
36Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Kota stone minimum 30mm thick.
37Supplying and fixing fixed wire gauge of 14 mesh x 24 gaugeto the metal frame of rolled section by metal beading 20x3mmwith suitable screw at not exceeding 150mm distance
38Patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects.
39Removal and refixing stone chhajja 50 to 75 mm thick including finishing, complete in all respects.
40Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
41Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead
42Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:In cement mortar.
43Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent with pair of CP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.
44Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
45Sanitary Items (Part-B)
46P & F Indian type white glazed vitreous china I st quality W.C. Orissa pan (I.S. : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor. Size 580 X 440 mm
47P & F WVC wash basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted I No 15 mm C.P. pillar cock (I.S. : 8934 Mark) & 32 mm C.P. Brass waste coupling of approved make 25 mm G.I. waste Pipe complete including cutting & making good the wall. & Floor Size 510 X 400 mm.
48P & F Looking Mirrors with P.V.C. frame of approved make as per direction of Engineer-in-charge Size 500x400mm
49P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 15 mm nominal bore
50P & F full way valve (IS 778 mark) or wheel valve of app make gunmetal 25 mm nominal bore
51P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design 500 litres capacity.
52P & F waste coupling with fitting of approved quality / make : C.P. Brass 32 mm dia
53P & F waste pipe with all fitting : PVC with PVC with cp nut 32 mm
54P & F flush/ flush Cock valve (IS 9758 mark) for WC to app quality / make brass/ gun metal half turn wt 1 Kg of quality/make 25 mm nominal bore
55P & F Grating of app quality / make stainless steel size 125 mm dia
56P & F Bib cock (IS 8931 mark) superior quality of app make Brass 400 gm 15 mm nominal bore
57P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)
58Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe. (Excluding cost of pipe) 100mm dia S.W. pipe
59P & F Bib cock (IS 8931 mark) superior quality of app make C P Brass 15 mm
60P & F Stop cock (IS 8931 mark) superior quality of app make Brass 400 gm 15 mm nominal bore
61P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :Brass wt. Not less than 300 gm,15mm
62P & F GI pipes (internal work) with fitting (IS 1239 mark) & MS clamps incl cutting & making good the walls & floor (a) exposed on wall 15 mm dia nominal bore B class
63P & F GI pipes (internal work) with fitting (IS 1239 mark) & MS clamps incl cutting & making good the walls & floor (a) exposed on wall 25 mm dia nominal bore B class
64P & F GI pipes ( External works ) with GI fittings eccluding Union (IS:1239 mark ) and MS clamps, including trenching and refilling earth etc.15 mm dia nominal size
65P & F GI pipes ( External works ) with GI fittings eccluding Union (IS:1239 mark ) and MS clamps, including trenching and refilling earth etc.25 mm dia nominal size
66P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. 3.5.1 Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm
67Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 100 mm thick C.C. 1:5:10 in foundation, 20 mm thick inside plaster in Cm 1:6 finished with floating neat cement, 50 mm thick M-154 grade C.C. flooring, earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside 300 X 300 mm depth up to 0.5 M & 5 kgs of cement cover with frame
68Construction of manhole in all type of soil inner size 90 X 60 cm 450 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20 mm thick inside plaster in Cm 1:6 finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, making channels 80 mm thick stone slab covering with 40 mm thick M-15 grade CC floor cement cover with frame of 450 mm dia earth work etc. complete as per design incl disposal of surplus earth within 50 mm lead. Depth up to 0.5 m
69P & F rigid PVC pipe (IS 4985 mark) class 11/4 kg/cm 2) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant (B) 110 mm dia
70P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricantBend 87.5 110mm
71P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant Vent cowel 110mm dia mm
72P & F rigid PVC pipe fitting (IS 4985 mark) appd quality/ make incl jointing the pipe with solvent cement rubber ring & lubricant Door Tee 110 Mm
73P & F 15 mm dia connection pipe of appd quality / make PVC pipe with CP Brass nuts up to length 450 mm
74P & F water closet seat covers with brass hinges complete : Solid PVC (ISI marked) grade-1 white for EWC
75P & F European type white glazed vitreous china 1 st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
76P & F jet spray for water closet with CP copper tube flange of approved make
77P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-in-Charge
78P & F low level Flushing Cistern of 10 liters capacity 9IS:2556 mark), of approve make with complete fittings CI brakets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS 7231
79Supply & fixing G.I. Union ISI marked in G.I. pipe line asrequired complete in all respect of size :2.32.1 15mm dia nominal bore
80Supply & fixing G.I. Union ISI marked in G.I. pipe line asrequired complete in all respect of size 25 mm dia nominal bore
81Electric (Part C)
82Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) virgin material UPVC trunking & it's accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material UPVC Modular Box , 10 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring ccessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR (A) short point (up to 3 mtr.)
83(B) Medium point (up to 6 mtr.)
84Long point (upto 10mtr.)
85Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm
86BSR 2 x 2.5 sq. mm. + 1x1.5sqmm
87P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
88Providing & Fixing of of 3/5 pin 6 amp. flush type non modular socket made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attachedwith this BSR
89Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSRSuitable for Six / Eight module for MCB/ RCCB
90Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 6 A to 32 A rating
91Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR30 A / 40 A rating
92Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating
93Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
94Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
95Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
96Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Recessed MountingMinimum lumen output 1950 lm
97Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56372952
AUTHORITY Government Departments
TENDER VALUE 6 Lakhs
LAST DATE 16-07-2026
Authority
Authority Name Ajmer Vidyut Vitran Nigam Limited
Work Description Tender for Renovation Work At Sub Division Deogarh
Basic Detail
Tender No NIT 05/26-27 UDR
Bidding Type Tender
Location
City Rajsamand
State Rajasthan
Key Dates
Publish Date 09 Jul 2026
Submission Date 16 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 6 Lakhs
Tender Fee 590
EMD 12000
Exemption Available
Document List
89a3f295-3cf9-4996-b8c5-e390c91cb254.html
BOQ_1020905.xls
TenderDoc.pdf
Tendernotice_1.pdf
TnC.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

89a3f295-3cf9-4996-b8c5-e390c91cb254.html

xls

BOQ_1020905.xls

pdf

TenderDoc.pdf

pdf

Tendernotice_1.pdf

pdf

TnC.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders