Tender for Rewiring To The Internal Electrical Works And Replacement The Luminaries And Accessories And Air Conditioner Water Heater Of Matiali Bunglow, Matiali Under Jalpaiguri Zilla Parishad, Est. No-6/15Th Fc(Untied)25-26(Elect)
BOQ
| Sl. No. | Item Description |
| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr |
| 2 | Average run 7 mtr |
| 3 | Average run 8 mtr |
| 4 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2x36/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC |
| 5 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Power & 20A Board] |
| 6 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [A.C. & Geyser Point] |
| 7 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (SPN DB) |
| 8 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC |
| 9 | Supplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).19mm dia 3mm thick Polythene Pipe |
| 10 | 25mm dia 3mm thick Polythene Pipe |
| 11 | Cutting Channel of size (31 mm x 31 mm) on RCC plastered ceiling by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles19 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 12 | Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles25 mm dia 3 mm thick polythene pipe without earthcontinuity wire |
| 13 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board |
| 14 | Supplying & Fixing GI Modular Switch Board of the followingsizes complete with three no. suitable size Copper bar withholes (for Ph, N & E) fixed on bakelite/Hard Rubber insulatorover the MS welded chairs incl. top cover flushed in wall forhousing the board after cutting the brick wall incl. makingearthing attachment, painting and mending good damages tobuilding works4 Module |
| 15 | 6 Module |
| 16 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 17 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 18 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 19 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 20 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 21 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Board] |
| 22 | Supply & Fixing 240 V LED based Modular type foot light Legrand Make on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 23 | Supply & Fixing 240 V Hotel Fob Card Switch Modular type Legrand Make on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 24 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmentUp to 250A, Seimens6 way |
| 25 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand (2+4 Way) Enclosure |
| 26 | (2+8 Way) Enclosure |
| 27 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment4 Way |
| 28 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection LegrandSingle pole 6-32A MCB |
| 29 | Double Pole 40A MCB Isolator |
| 30 | Double Pole 32A MCB Isolator |
| 31 | Two Pole 40A Power Contractor (Moduler Type) |
| 32 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connectionLegrand 160 A Legrand |
| 33 | Legrand 125 A Legrand |
| 34 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint &provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3phase, 50 Hz, 4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere , Volt , selector switches, frequency , phase indicating lamp, Energy complete including cost of busbar supports, detachable cable gland plates,2 earthing terminals, internal wiring &fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere , Volt , selector switch as per approved design & specification |
| 35 | Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification.Supply of 3Ph LED Ammeter Cl 0.5 |
| 36 | Supply of 3Ph LED Voltmeter Cl 0.5 |
| 37 | Supply of LED Freq meter Cl 0.2 |
| 38 | Supply of copper busbar for electrical power distribution |
| 39 | Supply of ammeter selector switch Current in Each phasewith OFF, 4 Pos. 90° angle of throw (OFF-R-Y-B) |
| 40 | Supply of voltmeter selector switch Votage between phaseswith OFF, 4 Pos. 90° angle of throw (OFF-RY-YB-BR) |
| 41 | Supply of 22.5 mm dia LED indicating lamps |
| 42 | Supply of indoor tape insulated ring type low tension current transformer of following rating100/5A 5VA, Cl 1.0 |
| 43 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 44 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire. |
| 45 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12\\") |
| 46 | Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)For Al : 30 cm Exhaust fan (12\\") |
| 47 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts &washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 48 | Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board |
| 49 | Supply & delivery of Sweep:- 48\\" (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON [Approved by EIC] |
| 50 | Supply & delivery Supply and delivery of Wall fan 16” Sweep metal blade a) Crompton Greaves make |
| 51 | Supply and delivery of 230V,50Hz Heavy duty Metal 9\\" Exhust Fan (EPC/Orient/Usha) |
| 52 | Supplying of approved make plastic ventilating exhaust fanAC 230-250.Ventilus 8” 200 Ivory, White, make : crompton |
| 53 | Supply and delivery of 230V,50Hz Heavy duty Metal 12\\" Exhust Fan (EPC/Orient/Usha) |
| 54 | Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts.450mm sweep |
| 55 | Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish |
| 56 | Laying of one No. cable above upto 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 57 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core upto 4 sqmm |
| 58 | For 2 core upto 10 sqmm |
| 59 | 3½ core 95 sqmm cable |
| 60 | 40 mm dia ISI |
| 61 | Finishing the end of following XLPE/PVC armoured cables bycrimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials3½ core 95 sqmm cable |
| 62 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5sqmm |
| 63 | 4sqmm |
| 64 | 6sqmm |
| 65 | 10sqmm |
| 66 | 16sqmm |
| 67 | Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed copper armoured Power/Control Copper Cables,Solid Copper conductor,XLPE Insulated,cores laid up, PVC tape innersheathed Armour(Glavanised wire) balance all galvanised steel strip),extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988 (make: Polycab/Gloster/Havells/KEI)2 Core 4sqmm CU ARMOURED Cable |
| 68 | 3½ core 95 sqmm cable |
| 69 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe |
| 70 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 71 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 72 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI wireNo. 6 SWG |
| 73 | No. 8 SWG |
| 74 | Supply and fixing of philips Soft Glow Office compliant fully diKused recessed mounted 2'X2' false ceiling based LED light including connection by 1.5 sq mm cu wire. |
| 75 | Supply and fixing of Green LED Ultima Square (6” x 6”) , incl cutting the false ceiling in reqd dimensions also the wiring and connection of the light by 1.5 sq mm cu wire complete.Make : Havells, 18 watt square/ round |
| 76 | SSupply and fixing of SkyCove LED Strip Light (5M length)with driver and necessary connection.Make : Havells, LED Strip SKYCove 5M WW with driver |
| 77 | Supply and fixing of Town Glow Post Top IP66/IK10 Post Top lantern with symmetric Light distribution complete with all accessories to be fixed on suitable pole incl. bolts and nuts incl making drilled holes etc to fixing up the landscape lighting pole complete.Make: Havells, 50W LED |
| 78 | Supply and fixing of greenline V2 street light (115 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Philips, 115 Watt |
| 79 | Supply TMC501 Conventional industrial batten Philips LED tube, model no : TMC 501 P 1xT-LED 22W P3241 with 1no Nos LED tube 1200mm 18W865 T8 I - 2100lm including necessary connection. |
| 80 | Supply and fixing of Endura LED Bulkhead Pressure Die cast housing LED bulkhead with IP66 Protection and IK09 impact resistance suitable for surface and wall mounting applications on ceiling fitting on wall /ceiling by screws etc.Make: Havells, 10WLED |
| 81 | Supplying of different types of LED lamps (9W)Make : Philips, 9.0 Watt, Base B22/ E27, 825 Lm |
| 82 | Supplying of different types of LED lamps (17W)Make: Philips, 17.0 Watt, Base B22/ E27, 1700 Lm |
| 83 | Supply & Fixing LED Mirror Light fittings dia-cast aluminium luminarie in powder coated white finish with optimized heat sink for efficient heat dissipation and separate including good all the damage and painting. [Approved by EIC] |
| 84 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener |
| 85 | Fixing only lamp |
| 86 | Providing & Fixing of ISI marked (IS : 15778 - 2007) Rigid CPVC drain water piping 6 kg/ cm2 with fiflings like elbow, socket, Tee etc& support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation complete in all respect.a) 20mm dia |
| 87 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre- approved by Engineer in charge. |
| 88 | Supply, installation, testing & commissioning of suction/ discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class 'O', etc complete as required.Copper tube 3/8” |
| 89 | Supply and Installation of Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC.1.0 Ton (Make : Hitachi) 3 star non-inverter type |
| 90 | Supply and Installation of Cassette type room air conditioning machine of following tonnage capacity 3 star rating fifled with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC.1.5 Ton Cassette AC Make : Hitachi |
| 91 | 2.0 Ton Cassette AC Make : Hitachi |
| 92 | Supply installation testing and commissioning of following capacity geyser 5 star rated storage water heater with advanced 3 level safetyFor 15L-capacity |
| 93 | Dismantling Existing Electrical Installation and its accessories and depositing the same as per instruction of EIC Electrician |
| 94 | Helper for Electrician |
| 95 | Addl. GST @18% |
| 96 | Addl LWC @1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender