Tender For Repairing Of Damaged Pipeline Due To Construction Of Surface Drain, Erection Of Electric Pole With Refitting Work, Repairing Of Existing Damaged Tap Connections And Allied Works In Pansila Water Supply Scheme In Nabadwip Block Under Krishn
Tender Overview
Project Description
Tender for Repairing Of Damaged Pipeline Due To Construction Of Surface Drain, Erection Of Electric Pole With Refitting Work, Repairing Of Existing Damaged Tap Connections And Allied Works In Pansila Water Supply Scheme In Nabadwip Block Under Krishnagar Sub Division Under Nadia Divison Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling all type of plain cement concrete works, stacking serviceable materials of site and removing rubbish as directed within a lead of 75mtr. for laying all dia pipe line in ground floor, upto 150mm thick |
| 2 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (Pakur Variety ) |
| 3 | Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, withnecessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C. |
| 4 | N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line.ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list.iii)No part payment at any stage on account of supply of materials shall be entertained.iv)Payment will be made on actual consumption of materials.v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list.vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so.vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item.viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill.Pressure Rating : Class - III Laying of pipe line including cost of pipe & fittings/specials but excluding valves. |
| 5 | 63 mm dia |
| 6 | 75 mm dia |
| 7 | 90 mm dia |
| 8 | 110 mm dia |
| 9 | 125 mm dia |
| 10 | 140 mm dia |
| 11 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) Do-by fine sand |
| 12 | Labour for boring (horizontal) through any kind of soil for road crossing LDS including hire charges & labour for supply of subtable dia crossing upto full width road with necessary tools, trackles, including Necessary arrangement for boring & pushing reqd.inclu. fixing, jointing pumping out accumulated water, lighting arrangement, sealing of two casing ends by B/W(1:4) etc. as per direction of EIC. (B/W to be given seperately) a) 150 mm dia |
| 13 | Filling the pipe line with water, testing hydraulically as per I.S 3114-1965 (Article-6) in section of a length not exceeding 500mtr. for head of pressure as per specification including supplying installing and fixing all equipments such as diesel pump set, blank flange, pressure gauge, valve, pressure pump and all other tools and plants including drilling topping and plugging of necessary holes to pipes, blocking ends providing temporary thrust block and subsequent blocking of holes and other jointing materials and dismantling and removal of the same including disposal of water etc. all complete as per specification and direction of EIC. The rate is inclusive of cost of requisite water to be arranged by the contractor (Recovery rate of water @ Rs.10.00/m3 , if contractor used water from deptt. source). 63 mm dia |
| 14 | 75 mm dia |
| 15 | 90 mm dia |
| 16 | 110 mm dia |
| 17 | 125 mm dia |
| 18 | 140 mm dia |
| 19 | Cleaning thoroughly the inner surface of pipe line including specials and valves by flushing with water and subsequently disinfection of the same pipe line by flushing again with water containing bleaching powder resulting in residual chlorine not less than 15mg/ltrs. after 24hrs. of such filling including laboratory testing of water samples obtain from the disinfested pipe line and disposal of water from the pipe line after completion of the work. The rates including of cost of requisite water to be arranged by the contractor) (The rate of water @Rs. 10/m3 may be recovered, if the contractor used water from deptt. source). 63mm dia |
| 20 | 75 mm dia |
| 21 | 90 mm dia |
| 22 | 110 mm dia |
| 23 | 125 mm dia |
| 24 | 140 mm dia |
| 25 | For Existing FHTC with ferrule connection,Refixing of existing ferrule with fittings in the proposed distribution pipeline and supply,fitting and fixing of all other accessories like saddle piece of required size to fit the proposed pipeline,specials,nut and bolt,rubber sheet,washers etc including cutting trenches in all shorts of soil and filling up trench as per direction of Engineer-in-Charge |
| 26 | Supply,fitting and fixing alloy iron with brass spindle bib cock/stop cock of approved brand and make spray painted and tested to 21 kg per sq cm i)15mm |
| 27 | Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials, cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I.pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) N) B. The rates for supply of non TATA but I.S.I. marked G.I. pipes and fittings will be arrived at by reducing the corresponding rates for TATA pipes and fittings by 20%. i)15mm dia medium quality |
| 28 | Earth work in filling in compound tank low land, ditches etc. with good earth in layer not exceeding 150mm. including breaking clods & consolidating the same by ramming & dressing complete.( Payment will be made on profile measurement before and after the work).(ii) With carried earth arranged by the contractor within a radius exceeding 3 km. but not exceeding 5 km. including the cost of carried earth. |
| 29 | Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R12/Gr-13non-magnetic, nuts seatrings are of Gun one tal as per IS:318LTB-2 flanges and drilled to IS:1538 PartIV &VI valves are suitable forma x. working pressure of 10kg/cm2(seattest)and body tested to 15kg/cm2.A) For CI/DI pipe250 mm dia |
| 30 | Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]i)250 mm to 350 mm dia |
| 31 | Supply of (DI) special (Mechanical Joint, Flange Socket, Flange Spigot, Flange Adopter, Bend,Tee, Reducer etc as per IS 1538 and 5331 with latest amendment offered rate for Kg, including all taxes, duties , charges as applicable and payable & delivery to destination which include loading, unloading, stacking, carriage (Payment will be made as per Book Weight) (As per IS-7181-1986). 62.11/1.01=52.27/1.12=54.90 |
| 32 | Add GST@18 % |
| 33 | Add Cess @1 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender