Housing Urban and Rular Development Government Departments Closing in 10 days TDR #56371194

Tender For Repair And Renovation Of Jai Prakash Narayan Sarvoday Vidhalay (Ats) Hardauli, Banda

Issued by Government Departments · Banda, Uttar Pradesh
Tender Value
1.96 Crore
Estimated cost
Bid Submission
22 Jul 2026
10 days left
EMD
3.93 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Banda → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Renovation Of Jai Prakash Narayan Sarvoday Vidhalay (Ats) Hardauli, Banda

BOQ

Name of Work:- Repair and Renovation of Jai Prakash Narayan Sarvoday Vidhalay (ATS) Hardauli, Banda
Sl. No. Item Description
1Main Building Civil WorkDismantling of old Plaster etc complete.Ceilling Plaster
2Dismantling of 12 mm thick old Outside Plaster etc complete.
3Dismantling of 15 mm thick Inside Plaster etc complete.
4Dismantling of 40 mm thick old PCC flooring etc complete.
5Dismantling of 25 mm thick old PCC flooring etc complete.
6Dismantling of old Kota stone flooring etc complete.
710 mm thick ceilling plaster 1:3 c: c/s mortar i/c all material, labour, T&P etc complete.
812 mm thick plaster 1:6 c: c/s mortar i/c all material, labour, T&P etc complete.
915 mm thick plaster 1:6 c: c/s mortar i/c all material, labour, T&P etc complete.
10Laying 40 mm thick 1:2:4 c:c/s & 20 mm S/grit with base for flooring i/c all Labour material T&P etc.
11Laying Kota stone flooring with 20 mm averase thick 1:3 c:c/s mortar base plaster i/c all Labour material T&P etc.
12P/F Glass strps 4.00 mm thick in joint of floor i/c all Labour T&P etc.
13Supply & Fixing of 6 mm thick Chaina white glazed Tiles with 15 mm averase thick 1:3 c:c/s mortar base plaster i/c all Labour material T&P etc.
14Scrapping of old White wash, snowcem & Apex etc complete
15Scrapping of old Enamel paint in steel & wooden surface etc complete
16Supply & Fixing of 32 mm thick ISI Mark commercial quality flush door shutter etc. complete
17Two coat oil bound destemper & one base coat of primar i/c all material, labour, T&P etc complete.
18Providing & Laying of weather coat Appex paint two coat over one coatapproved primer i/c all material, labour, T&P etc complete.
19Two coat Enamil paint with one coat base primer in door & window i/c all material, labour,T&P etc complete.
20Non Scheduled ItemRepairing of Wardrobe shutter at site etc complete.(b/f item no.17)
21Repairing of Fabrication items for damaged window & door at site etc complete.
22Supply & Fixing of Oxidized door fitting etc. complete (b/f item no.20)
23Supply & Fixing of BP Sheet on window & ventilattor etc complete.
24Cleaning & Repairing of Septic tank at site etc complete.
25Cleaning & Repairing of Soak pit at site etc complete.
26Cleaning & Repairing of Men Hole Chamber at site etc complete.
27L.S.Labour chargeg for dismentling of Sewage System old for toilet etc complete.
28Boundary Wall ( New )Tor Steel work for RCC
29R.C.C. 1:1½:3 Cement: C/s, & S/g in Material and T&P etc. complete. Pile
30R.C.C. 1:1½:3 Cement: C/s, & S/g in Material and T&P etc. complete. Grade Beam
31R.C.C. 1:1½:3 Cement: C/s, & S/g in Material and T&P etc. complete. Column
32M-150 Brick work in 1:6:C:C/s in S/S in 230 mm thick wall i/c all labour, Material and T&P etc. complete.
33P.C.C. 1:2:4 Cement: C/s, & S/g in Material and T&P etc. complete.
3412/15 mm thick cement plaster in single coat with 1:6:c:c/s mortar i/c all labour, Material and T&P etc. complete. 395.35+343.66 /2 = 369.51
35Providing of two coat water proofing cement paintwith one coat white cement etc complete.
36Supply & Fixing of M.S. Iron Grill i/c all labour material T&P etc complete.
37Two coat Emamil penting over one coat Red oxide primer i/c all labour material T&P etc complete.
38Providing and fixing removel of shuttering for R.C.C. work in etc complete.(A) Grade Beam
39Providing and fixing removel of shuttering for R.C.C. work in etc complete.(B) Column
40Non Scheduled ItemMaking Borehole of Pile 250 mm dia & 3.00 Mtr. Depth S.U.R.
41Boundary Wall (Old) RepairDesmentling of old M.S. Grill of Boundry wall etc complete.
42Desmentling of old RCC work of Boundry wall etc complete.
43Desmentling of old Brick work of Boundry wall etc complete.
44R.C.C. 1:1½:3 c:c/s:sg 20mm S/grit i/c all labour material T&P etc complete.
45Tor Steel work i/c all labour material T&P etc complete.
46Brick masonary 1:6 c:c/s mortar in Super Structure i/c all labour material T&P etc complete.
47Supply & Fixing of M.S. Iron Grill i/c all labour material T&P etc complete.
4812/15 mm thick (1:4) c/s mortar for plastering i/c all labour material T&P etc complete.
49Finishing of Wall with water proofing cement paint two coat over one coat white cement etc complete.
50Two coat Emamil penting over one coat Red oxide primer i/c all labour material T&P etc complete.
51Providing and fixing removel of shuttering for R.C.C. work in etc complete.(A) Lintel bend
52Providing and fixing removel of shuttering for R.C.C. work in etc complete.(B) Column
53Surface DrainEarth work excavation in foundation of Drain etc.
54Supply & Filling of Sand in blancket coat i/c all labour material T&P etc complete.
55Laying cement concrete 1:4:8 Cement: C/s, & S/b in base i/c all Material and T&P etc. complete.
56M-150 Brick work in 1:4:C:C/s in F/P in wall i/c all labour, Material and T&P etc. complete.
57P.C.C. 1:2:4 Cement: C/s, & S/g in Material and T&P etc. complete.
5812 mm thick cement plaster in single coat with 1:6:c:c/s mortar i/c all labour, Material and T&P etc. complete.
59Gate - 1Tor Steel work cutting, bending i/c all material labour and T&P etc complete
60Earth work excavation in foundation of Pile Cap i/c all material labour and T&P etc complete
61Laying Cement Concrete in 1:4:8 [C:C/s:S/b] i/c all material labour and T&P etc complete.
62R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete.(a) Pile
63R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete.(b) Pile Cap
64R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete.(c) Column
65M-150 Brick work in 1:6 [C:C/s] in S/S i/c all material labour and T&P etc complete
6612 mm thick Plaster in 1:6 [C:C/s] i/c all material labour and T&P etc complete.
67Supply & Fixing of M.S. Pipe Column i/c all labour material T&P etc complete.
68Supply & Fixing of M.S. Pipe Gate i/c all labour material T&P etc complete.
69Two coat Emamil penting over one coat Red oxide primer i/c all labour material T&P etc complete.
70Providing and fixing removel of shuttering for R.C.C. work in etc complete. (A) Pile Cap
71Providing and fixing removel of shuttering for R.C.C. work in etc complete. (B) Column
72Non Scheduled ItemMaking Borehole of Pile 250 mm dia & 3.00 Mtr. Depth S.U.R.
73Supply & Fixing of M.S. Sheet i/c all labour material T&P etc complete.
74Two coat Emamil penting over one coat Red oxide primer M.S.Column & Top Beam i/c all labour material T&P etc complete.
75Gate - 2Tor Steel work cutting, bending i/c all material labour and T&P etc complete
76Earth work excavation in foundation of Pile Cap i/c all material labour and T&P etc complete
77Laying Cement Concrete in 1:4:8 [C:C/s:S/b] i/c all material labour and T&P etc complete.
78R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete. (a) Pile
79R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete. (b) Pile Cap
80R.C.C. 1:1½:3 c:c/s:sg 20mm GSB i/c all labour material T&P etc complete. (c) Column
81M-150 Brick work in 1:6 [C:C/s] in S/S i/c all material labour and T&P etc complete
8212 mm thick Plaster in 1:6 [C:C/s] i/c all material labour and T&P etc complete.
83Supply & Fixing of M.S. Pipe Column i/c all labour material T&P etc complete.
84Supply & Fixing of M.S. Pipe Gate i/c all labour material T&P etc complete.
85Two coat Emamil penting over one coat Red oxide primer i/c all labour material T&P etc complete.
86Providing and fixing removel of shuttering for R.C.C. work in etc complete. (A) Pile Cap
87Providing and fixing removel of shuttering for R.C.C. work in etc complete. (B) Column
88Non Scheduled ItemMaking Borehole of Pile 250 mm dia & 3.00 Mtr. Depth S.U.R.
89Supply & Fixing of M.S. Sheet i/c all labour material T&P etc complete.
90Two coat Emamil penting over one coat Red oxide primer M.S.Column & Top Beam i/c all labour material T&P etc complete.
91Sanatry WorkProviding and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
92Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps
93Providing and fixing of Stainless Steel sink. 600x400x200 mm
94Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 32 mm dia
95Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 40 mm dia
96Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
97600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
98Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) SingleSupply & fixing of 110mm PVC pipe complete
99Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good thewalls etc. :17.37.1 For 100 mm dia pipe
100Supply & fixing of 110mm PVC door \\"T\\" 110x110x110mm
101Supply & fixing of 110mm PVC Plain band
102Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :Supply & fixing of CP bib cock short body 15mm
103Supply & fixing of CP bib cock long body 15mm
104Supply & fixing of CP angle valve 15mm
105Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal boreProviding and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
106Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
107Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
108Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 25mm Brass ball coke
109Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
110Making connection in inlet.
111Providing & fixing of 150mmØ PVC Sewer line.
112Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
113Water Supply Pipe LineConcealed work, including cutting chases and making good the walls etc.Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Supply & fixing of 15mmØ G.I. Pipe line Concilled pipe line.
114Supply & fixing of 25mmØ G.I. Pipe line for main
115Supply & fixing of 32mmØ G.I. Pipe in
116external work.
117Non Scheduled ItemSupply & fixing of 110mm PVC trap
118Supply & fixing of 110mm PVC Coval
119Supply & fixing of 100x75mm PVC Nahani trap
120Supply & fixing of 100mm PVC Door band
121Supply & fixing of 100mm C.P. Jali
122Supply & fixing of C.P. Hook
123ELECTRICAL WORK (Main Building)Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required.Group C
124Wiring for twin control light point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way Modular switch, Modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
125Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
126Wiring for light / power plug with 2 x 1.50 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 1.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
127Wiring for light / power plug with 2 x 2.50 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 2.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
128Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
129Wiring for light / power plug with 2 x 6.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
130Wiring for light / power plug with 4 x 10.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 2 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
131Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
132Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
133Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
134Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
135Market Rate - (Non Scheduled Items) -Supply and fixing of crimping, solderless, copper tin electroplated lugs of Dowells/Ismail make suitable for 1.5 sq.mm to 2.5 sq.mm cables, including tapping with insulating tape, complete in all respect.
136Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
137Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
138Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
139Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respectwith 3 years warranty.
140Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 2 x 22 watt suitable for upto 2 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect.with 3 years warranty
141S/F of 'Al' Lugs & Gland complete in all respect.
142Supply & Fixing of Fan Sheet of Backelite
143Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
144S/F of LED Bulb 9 watt ISI
145ELECTRICAL WORK ( Dormetory Block)Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required.Group C
146Wiring for twin control light point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way Modular switch, Modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
147Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
148Wiring for light / power plug with 2 x 1.50 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 1.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
149Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
150Wiring for light / power plug with 2 x 6.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
151Wiring for light / power plug with 4 x 10.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 2 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
152Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
153Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
154Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
155Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 40 Amp.
156Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 63 Amp.
157Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
158Market Rate - (Non Scheduled Items) -Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
159Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
160Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
161Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respectwith 3 years warranty.
162Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 watt. Confirming to IP 66 and above Protection complete in all respect. Cat-AAA
163S/F of 'Al' Lugs & Gland complete in all respect.
164Supply & Fixing of Fan Sheet of Backelite
165S/F of LED Bulb 9 watt ISI
166S/f of ceiling fan 1200 mm sweep. Single star rated Usha / Crompton/Bajaj mak
167Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
168Supply & Fixing of light duties exhaust fan 12”dia ISI double ball bearing metalic Usha / Crompton/Bajaj make
169Supply & Fixing of exhaust fan luvers 12”
170ELECTRICAL WORK ( Kitchen & Dining Block)Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required.Group C
171Wiring for twin control light point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way Modular switch, Modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
172Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
173Wiring for light / power plug with 2 x 1.50 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 1.50 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
174Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
175Wiring for light / power plug with 2 x 6.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
176Wiring for light / power plug with 4 x 10.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 2 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
177Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
178Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
179Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
180Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 63 Amp.
181Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
182Market Rate - (Non Scheduled Items) -Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
183Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
184Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge.
185Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect with 3 years warranty.
186S/F of 'Al' Lugs & Gland complete in all respect.
187Supply & Fixing of Fan Sheet of Backelite
188S/F of LED Bulb 9 watt ISI
189S/O of ceiling fan 1200 mm sweep. Single star rated Usha / Crompton/Bajaj mak
190Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
191Supply of light duties exhaust fan 12”dia ISI double ball bearing metalic Usha / Crompton/Bajaj make
192Supply & Fixing of exhaust fan luvers 12” or 18\\"
193ELECTRICAL WORK ( Type-III )Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required.Group A
194Wiring for twin control light point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way Modular switch, Modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
195Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
196Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
197Wiring for light / power plug with 2 x 6.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
198Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
199Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 40 Amp.
200Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
201Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
202Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
203Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
204Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
205Market Rate - (Non Scheduled Items) -Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
206ELECTRICAL WORK (Type-II )Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required.Group A
207Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
208Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
209Wiring for light / power plug with 2 x 10.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
210Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
211Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 63 Amp.
212Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
213Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
214Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
215Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
216Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
217Market Rate - (Non Scheduled Items) -Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
218S/F of LED Bulb 9 watt ISI
219ELECTRICAL WORK ( Type-I )Schedele Rate - (As per CPWD - DSR (E&M) -2022)Wiring for light point/fan point /exhaust fan point /call bell point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group A
220Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
221Wiring for light / power plug with 2 x 4.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 4.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
222Wiring for light / power plug with 2 x 10.00 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, along with 1 No. 6.00 sq. mm FRLS PVC insulated copper conductor single core for loop earthing as required.
223Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole
224Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 63 Amp.
225Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
226Providing and fixing 25 mm x 5 mm G I strip on surface or in recess for connections etc. as required.
227Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required.
228Supplying and fixing call bell/buzzer suitable for single phase, 230 V, complete as required.
229Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
230Market Rate - (Non Scheduled Items) -Wiring Invertor point for light / Fan/Plug point with 1.5 mm copper wire.
231S/F of LED Bulb 9 watt ISI
232ELECTRICAL WORK (Campus Street Light )Schedele Rate - (As per CPWD - DSR (E&M) -2022)Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1010 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.Above 95.00 sq. mm & Upto 185 sq.mm
233Supplying, installing, testing and commissioning o following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required400 Amp TPN
234Earthing with G I earth pipe 4.5 mtr. Long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
235Market Rate - (Non Scheduled Items) -Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect.
236Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 90 watt. Confirming to IP 66 and above Protection complete in all respect. With 3 years warranty.
237S/F cable, wire, Required Lugs, Gland etc.
238S/L of Service Cable 4 sq.mm x 2 core with G.I. support wire.
239Supply of Al. Armoured Cable 95 sq.mm x 3½ core. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56371194
AUTHORITY Government Departments
TENDER VALUE 1.96 Crore
LAST DATE 22-07-2026
Authority
Authority Name Uttar Pradesh State Construction And Infrastructure Development Corporation Limited
Work Description Tender for Repair And Renovation Of Jai Prakash Narayan Sarvoday Vidhalay (Ats) Hardauli, Banda
Basic Detail
Tender No 40/SE/e-Tender/Cktd/2026-27 Dt 08-07-2026
Bidding Type Tender
Location
City Banda
State Uttar Pradesh
Key Dates
Publish Date 09 Jul 2026
Submission Date 22 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 1.96 Crore
Tender Fee 3540
EMD 3.93 Lakhs
Exemption Not Available
Document List
289ee18b-6ae7-4867-8810-d127fef42537.html
BOQ_2190251.xls
BoQ_ATSHardauliPDF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

289ee18b-6ae7-4867-8810-d127fef42537.html

xls

BOQ_2190251.xls

pdf

BoQ_ATSHardauliPDF.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders