Tender For Repair / Maintenance Of External Ht Line Incl Maintenance Of Transformers , God Switches And Connected Works At Ta, Keri Under Age (I) Cif (R)
Tender Value
5.70 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
18 days left
EMD
11400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of External Ht Line Incl Maintenance Of Transformers , God Switches And Connected Works At Ta, Keri Under Age (I) Cif (R)
BOQ
| Sl. No. | Item Description |
| 1 | Taking down broken/defective PCC/steel tubular pole, keeping away from site and S&F of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 meters long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and directed.Note : PCC & Earth work will be measured and paid seperately. |
| 2 | Taking down defective/ broken anti climbing devices from pole and keep away from site and S&F in replacement of same item, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed. Note :- Clamps will be measured separately. |
| 3 | Taking down of existing unserviceable cross arms, bracing, supports, clamps and back plates and S&F in replacement of same item fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and as directed. |
| 4 | Taking down of existing unserviceable Danger notice plate and S&F in replacement of same item of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for HT poles, 25 x 20 cm size including taking out old unserviceable danger notice plate complete all as specified and directed. |
| 5 | M&L in replacement for Stay assembly complete with accessories as shown in electric plate No.1 stay rod 16 mm incl taking down complete (loop type insulator stay clamps excavation & concrete measured separately) complete all as specified and directed. |
| 6 | M&L for Loop type insulator vitreous porcelain, brown or green with overall dimensions 65 X 90 mm, clearance of hole 16mm all as specified and as directed. |
| 7 | S&F replacement of Lightning Arrestor expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable for working pressure of 11000 Volts, complete all as specified and directed. |
| 8 | Taking down of existing unserviceable/broken Switch Air Break Gang Operated for 11 KV grade and keeping away from site and S&F in replacement of same item, Triple pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 400 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuse , complete all as specified and as directed. |
| 9 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 metre deep below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washer of galvanised steel and connected to main switch board or main control board as directed and including provn of concrete pit in PCC (1:3:6), type C-I, pre-cast RCC (1:2:4) type B-1 cover slab 54 cm X 54 cm X 5 cm 9Reinforced with 8mm dia TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earthwork in any type of soil and including necessary testing, complete all as per electrical plate No. 3 of SSR 2009 Part-I, all as specified and directed. |
| 10 | All as per Srl item No. 09 above herein before but with GI strip of size 32 X 6 mm, complete all as specified and directed. |
| 11 | Excavation in trenches, in loose/soft soil not exc. 1.5m wide and not exc. 1.5m in depth; for pole, shafts, wells, cesspits, manholes, pier holes, etc. and getting out of any type of soil for laying UG cables of various sizes, complete all as specified and as directed. |
| 12 | All as per Srl item No. 11 above but depth exc beyond 1.5m and not exc 3m, complete all as specified and as directed. |
| 13 | Removing excavated material a distance not exc 50m & depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. |
| 14 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm thick in soils, complete all as specified and directed. |
| 15 | Sand cushioning with fine dry unwashed sand in trenches for protection of cables, complete all as specified and directed. |
| 16 | Well burnt bricks, sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection, complete all as specified and directed. |
| 17 | PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in stay assembly etc including necessary form work, complete all as specified & directed. |
| 18 | PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed. |
| 19 | PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping around pole and filling in road cuts / hard standing / bitumen including necessary form work, complete all as specified & directed. |
| 20 | Trimming of tree branches and making clear the overhead HT line to the min distance of 1.8 mtrs all around for 2/3/4/5/6 conductor. (Note: The span between two poles will be measured in RM). |
| 21 | Cutting of green growth and wild grass by manual labour or by machine at electrical installation premises,around the pole,along the fencing,removing rubbish from the site of work and depositing where directed not exc 100 Mtr from the starting point. complete all as specified and directed. Note :- The item shall be operated maximum 4 times in the entire period of the contract and the measurement will be taken every time independently for the payment. |
| 22 | Supply & laying in replacement of HT XLPE Cable, insulated, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 11 KV, ‘Earthed Grade, cross-sectional area 95 Sqmm 3 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/under Road including Testing and disconnecting & taking out of existing HT cable of any type and size, complete all as specified and as directed.NOTE : Earthworks including excavation, returning filling in, removing, HDPE pipe for mechanical protection of cable etc. will be measured and paid under appropriate Items. |
| 23 | Supply & laying in replacement of LT XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 120 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 24 | Supply & laying in replacement of LT XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 25 | Supply & laying in replacement of LT XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 185 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 26 | Material & labour for Cable termination for 11 KV HT (Heat shrinkable) cable End jointing kit outdoor type for 11KV grade cable, Heat shrink type joint complete with jointing material and accessories suitable for 11 KV 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specifed & directed. |
| 27 | Material & labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through joint, heat shrink type joint complete with jointing material and accessories suitable for 11 KV 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specifed & directed. |
| 28 | Dismantling and taking down any type of transformers indoor/outdoor,by disconnect HT & LT connections from plinth/ platform/ pole mounted and shifting to workshop and refix it back on site after all repairs and testing and commissioning, conducting all tests and complete of work all as specified and directed.Note: (i) LV/HV bushes, Silica gel breather etc will be measured and paid for separately.(ii) Draining out all the transformer oil, dismantling and inspection of transformer core and winding including taking out burnt out winding/insulation of LV/HV coils in the presence of the authorized rep and rewinding the damaged core wih suitable gauge of copper winding wire winding, drying out in Heat chamber till specified IR values are obtained and providing new insulation materials, gasket, nuts, bolts, checking of leakages and rectifying the same by welding etc.(iii)While removal of the core care shall be taken not to spoil the transformer oil and required f iltration including topping up shall be carried out, which shall be measured and paid under respective items of schedule for carry out repair (rewinding) works as directed and reinstall back in original location including re-connection of HT & LT supply system including testing complete all as specified and directed for the following capacity. (Note spare items required for repair including rewinding will be measured and paid seperately under respective items of Sch. Please Enable Macros to View BoQ information |
| 29 | Dismantling and taking down any type of transformers indoor/outdoor,by disconnect HT & LT connections from plinth/ platform/ pole mounted and shifting to workshop and refix it back on site after all repairs and testing and commissioning, conducting all tests and complete of work all as specified and directed.Note: (i) LV/HV bushes, Silica gel breather etc will be measured and paid for separately.(ii) Draining out all the transformer oil, dismantling and inspection of transformer core and winding including taking out burnt out winding/insulation of LV/HV coils in the presence of the authorized rep and rewinding the damaged core wih suitable gauge of copper winding wire winding, drying out in Heat chamber till specified IR values are obtained and providing new insulation materials, gasket, nuts, bolts, checking of leakages and rectifying the same by welding etc.(iii)While removal of the core care shall be taken not to spoil the transformer oil and required f iltration including topping up shall be carried out, which shall be measured and paid under respective items of schedule for carry out repair (rewinding) works as directed and reinstall back in original location including re-connection of HT & LT supply system including testing complete all as specified and directed for the following capacity. (Note spare items required for repair including rewinding will be measured and paid seperately under respective items of Sch. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓