Tender For Repair & Replacement Of Lt Ug Cable Connected Lt Swith Gear System With External Light Fittings And Allied Works At Air Force Stn Under Ge Avadi.

Issued by Statutory Bodies & Commissions/Committees · Thiruvallur, Tamil Nadu
Tender Value
49 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
17 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvallur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Replacement Of Lt Ug Cable Connected Lt Swith Gear System With External Light Fittings And Allied Works At Air Force Stn Under Ge Avadi.

BOQ

Name of Work:- REPAIR & REPLACEMENT OF LT UG CABLE CONNECTED LT SWITH GEAR SYSTEM WITH EXTERNAL LIGHT FITTINGS AND ALLIED WORKS AT AIR FORCE STN UNDER GE AVADI.
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out any type of soil for laying cables/pipes/erection of poles etc., complete, all as specified and directed.
2Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete, all as specified and directed.
3Returning and filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each, complete, all as specified and directed.
4Laying in trenches fine sieved excavated dry soil including spreading, levelling and cushioning for underground cables, complete, all as specified and directed.
5Supply and laying of common burnt clay building bricks, sub class ‘B’ size, for cable protection, complete, all as specified and directed.
6M&L for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in replacement of existing unserviceable cable/OH line ACSR conductor of any type, including taking down old cable, for size 10 sq mm 2 core cable, complete, all as specified and directed. Note: Earthwork and connected items shall be measured and paid separately under respective items of Schedule.
7All as per item No. 6.00 hereinbefore but for 16 sq mm 4 core cable, complete, all as specified and directed.
8All as per item No. 6.00 hereinbefore but for 25 sq mm 3.5/4 core cable, complete, all as specified and directed.
9All as per item No. 6.00 hereinbefore but for 35 sq mm 3.5 core cable, complete, all as specified and directed.
10All as per item No. 6.00 hereinbefore but for 50 sq mm 3.5 core cable, complete, all as specified and directed.
11All as per item No. 6.00 hereinbefore but for 70 sq mm 3.5 core cable, complete, all as specified and directed.
12All as per item No. 6.00 hereinbefore but for 95 sq mm 3.5 core cable, complete, all as specified and directed.
13All as per item No. 6.00 hereinbefore but for 120 sq mm 3.5 core cable, complete, all as specified and directed.
14All as per item No. 6.00 hereinbefore but for 185 sq mm 3.5 core cable, complete, all as specified and directed.
15Taking out LT XLPE UG cable/PVC sheathed aluminium conductor armoured cable from trenches/poles/walls etc. and relaying after fault rectification duly tested in trenches/poles/walls for LT UG cable 4 core 16 sq mm, complete, all as specified and directed. Note: Earthwork and connected items shall be measured and paid separately under respective items of Schedule.
16All as per item No. 15.00 hereinbefore but for LT UG cable 3.5/4 core 25 sq mm to 3.5 core 50 sq mm, complete, all as specified and directed.
17All as per item No. 15.00 hereinbefore but for LT UG cable 3.5 core 70 sq mm to 3.5 core 120 sq mm, complete, all as specified and directed.
18All as per item No. 15.00 hereinbefore but for LT UG cable 3.5 core 150 sq mm to 3.5 core 185 sq mm, complete, all as specified and directed.
19Testing cables with high voltage DC testing machine and locating faults by cable fault locating machine to pinpoint exact location of fault, disconnecting faulty 1.1 KV LT cables of different sizes from both ends, removal of fault, reconnection and testing after rectification, complete, all as specified and directed.
20Supply and fixing of straight through heat shrink type cable jointing kit suitable for underground LT XLPE/PVC sheathed armoured heavy duty aluminium conductor cables of size 3.5/4 core 16 sq mm to 50 sq mm, complete, all as specified and directed.
21All as per item No. 20.00 hereinbefore but for LT XLPE/PVC sheathed armoured heavy duty aluminium conductor cable of size 3.5/4 core 70 sq mm to 120 sq mm, complete, all as specified and directed.
22All as per item No. 20.00 hereinbefore but for LT XLPE/PVC sheathed armoured heavy duty aluminium conductor cable of size 3.5/4 core 150 sq mm to 185 sq mm, complete, all as specified and directed.
23M&L for GI tubing light grade for cable protection laid in trenches/road crossings or fixed to walls/poles including taking down old unserviceable tubing, for 40 mm bore GI tube, complete, all as specified and directed.
24All as per item No. 23.00 hereinbefore but for 50 mm bore GI tube, complete, all as specified and directed.
25All as per item No. 23.00 hereinbefore but for 80 mm bore GI tube, complete, all as specified and directed.
26M&L in replacement of outdoor type aluminium bus bar chamber feeder box of capacity 300 Amps, 3 phase, 4 wire, 415 Volts, size 90 x 60 x 45 cm including incomer MCCB 300 Amps, 4 pole, 36 KA breaking capacity. The panel shall be fabricated with 3.15 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over one coat of red oxide primer and fixed/supported with angle iron frame grouted in PCC 1:2:4 up to 0.60 m above ground level and 0.40 m below ground level. Contractor shall submit drawing and obtain approval before placing order, complete, all as specified and directed.
27M&L in replacement of outdoor type aluminium bus bar chamber feeder box of capacity 300 Amps, 3 phase, 4 wire, 415 Volts, size 90 x 60 x 45 cm including incomer MCCB 250 Amps, 4 pole, 36 KA breaking capacity. The panel shall be fabricated with 3.15 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over one coat of red oxide primer and fixed/supported with angle iron frame grouted in PCC 1:2:4 up to 0.60 m above ground level and 0.40 m below ground level. Contractor shall submit drawing and obtain approval before placing order, complete, all as specified and directed.
28M&L for boring under roads without disturbing the top surface of road for passing cables using 75 mm dia HDPE pipe including necessary tools, plants, machinery and equipment required for boring operation. Note: HDPE pipe shall be measured and paid separately under relevant item, complete, all as specified and directed.
29M&L for 75 mm dia HDPE pipe PN-10 with fittings laid in trenches/walls for protection of underground cable at road crossings/fixed on walls as in repairs, complete, all as specified and directed.
30M&L for cutting road/path for laying GI tubing and making good disturbed road/path including providing PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate, complete, all as specified and directed.
31S&F in replacement of LED energy saving high bay light fitting of capacity 150 Watt, IP-65 protection with high efficiency integrated electronic driver fixed at hangers/sheds including connection to light fitting with suitable size cable and suitable fixing arrangement to trusses, complete, all as specified and directed.
32Supply and fixing in replacement of LED flood light fitting, 230 V AC, 120 Watt LED, outdoor type with heat resistant toughened glass, IP-65/66 protection with driver, fixed on existing/new bracket and making connections including taking down old fitting, complete, all as specified and directed.
33Supply and fixing in replacement of LED flood light fitting, 230 V AC, 100 Watt LED, outdoor type with heat resistant toughened glass, IP-65/66 protection with driver, fixed on existing/new bracket and making connections including taking down old fitting, complete, all as specified and directed.
34Supply and fixing in replacement of LED flood light fitting, 230 V AC, 210 Watt LED, outdoor type with heat resistant toughened glass, IP-65/66 protection with driver, fixed on existing/new bracket and making connections including taking down old fitting, complete, all as specified and directed.
35M&L for replacement of 1100 Volts grade heavy duty cable, PVC insulated, PVC sheathed, fire resistant, round copper conductor, 3 core industrial cable of size 1.50 sq mm including taking down old unserviceable cable, complete, all as specified and directed.
36All as per item No. 35.00 hereinbefore but for 1100 Volts grade heavy duty cable, PVC insulated, PVC sheathed, fire resistant, round copper conductor, 3 core industrial cable of size 2.50 sq mm including taking down old unserviceable cable, complete, all as specified and directed.
37M&L for MCCB 63 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz AC, 16 KA breaking capacity. The MCCB shall have spreader links and barriers as standard features of manufacturer including taking down old unserviceable MCCB, complete, all as specified and directed.
38All as per item No. 37.00 hereinbefore but for MCCB of capacity 100/125 Amps, 25 KA breaking capacity including taking down old unserviceable MCCB, complete, all as specified and directed.
39All as per item No. 37.00 hereinbefore but for MCCB of capacity 160 Amps, 36 KA breaking capacity including taking down old unserviceable MCCB, complete, all as specified and directed.
40All as per item No. 37.00 hereinbefore but for MCCB of capacity 200 Amps, 36 KA breaking capacity including taking down old unserviceable MCCB, complete, all as specified and directed.
41All as per item No. 37.00 hereinbefore but for MCCB of capacity 250 Amps, 36 KA breaking capacity including taking down old unserviceable MCCB, complete, all as specified and directed.
42All as per item No. 37.00 hereinbefore but for MCCB of capacity 400 Amps, 26 KA breaking capacity including taking down old unserviceable MCCB, complete, all as specified and directed.
43M&L for open enclosure type on load change over switch, 200 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz AC suitable for fixing in panels including taking down old unserviceable switch, complete, all as specified and directed.
44S&F in replacement of ACB 800 Amps, 50 KA breaking capacity, 4 pole with microprocessor release, draw out type including necessary connections, complete, all as specified and directed.
45M&L for replacement of earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at depth not less than 2.25 m below normal ground level with top edge of plate not less than 1.5 m below ground level, surrounded by 15 cm thick packed layer of charcoal dust and common salt, including electrode connection with 25 x 4 mm GI strip, bolts, nuts, check nuts and washers, GI protection pipe, watering arrangement with funnel, wire mesh, RCC pit cover and PCC chamber including excavation, earthwork and disposal of surplus soil, complete, all as specified and directed.
46M&L for replacement of earth continuity conductor/main earthing conductor of 25 mm x 4 mm galvanised iron strip fixed to wall on batten with saddles and fixing screws or PVC/porcelain insulators, recessed in chase, buried in ground, drawn in conduit/pipe or fixed to poles including brazing on both sides at all joints for loop earthing, complete, all as specified and directed.
47Repair to earth pit including necessary excavation, earthwork and PCC work to make good damaged/disturbed surfaces of earth pit chamber, providing new RCC 1:2:4 Type B-1 pit cover using 20 mm graded stone aggregate reinforced with 8 mm MS bars @ 150 mm centre to centre both ways including lifting handle, wire mesh, funnel and reconnection of earth strip/wire with panel/equipment using GI nuts, bolts and washers, complete, all as specified and directed.
48M&L for repairing/welding existing broken LT panel door including replacement/repair of defective parts such as packing, nuts, bolts, hinges and welding works etc. to make the panel door serviceable, complete, all as specified and directed. Note: One door shall be considered as one job.
49M&L for preparation of old painted surfaces of panel board by cleaning, removing old paint by wire brushing/sand papering including denting of broken/rusted surfaces and applying two coats of synthetic enamel paint by spray painting on outside surface matching existing colour of panel, complete, all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56370355
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair & Replacement Of Lt Ug Cable Connected Lt Swith Gear System With External Light Fittings And Allied Works At Air Force Stn Under Ge Avadi.
Basic Detail
Tender No 8442/E8
Bidding Type Tender
Location
City Thiruvallur
State Tamil Nadu
Key Dates
Publish Date 09 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Available
Document List
8442TENDERDOCUMENTS.pdf
9802713a-8572-4f02-a2da-fd248434e0ee.html
BOQ_870557.xls
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

8442TENDERDOCUMENTS.pdf

html

9802713a-8572-4f02-a2da-fd248434e0ee.html

xls

BOQ_870557.xls

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders