Tender For special Repair For Replacement And Unserviceable /Ber Water Cooler,Refrigerator & Provn Of Servo Voltage Stabilizer At Various Locations At Saa Under Ge(S) Tezpur
Tender Value
45.35 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
18 days left
EMD
90700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair For Replacement And Unserviceable /Ber Water Cooler,Refrigerator & Provn Of Servo Voltage Stabilizer At Various Locations At Saa Under Ge(S) Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, commissioning and testing of Refrigerator electric driven (single phase), 3 star rating double door, capcity 400 liters capacity complete all as sepcified and directed. |
| 2 | Supply, installation, commissioning and testing of Refrigerator electric driven (single phase), 3 star rating double door, capcity 310 liters capacity complete all as sepcified and directed. |
| 3 | Supply, installation, commissioning and testing of Refrigerator electric driven (single phase), 3 star rating double door, capcity 250 liters capacity complete all as sepcified and directed. |
| 4 | Supply, installation, commissioning and testing of Refrigerator electric driven (single phase), 3 star rating double door, capcity 185 liters capacity complete all as sepcified and directed. |
| 5 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40/80 Ltr complete all as specified and directed. |
| 6 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 60/120 Ltr complete all as specified and directed. |
| 7 | Supply, installation, commissioning and testing of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 150/150 Ltr complete all as specified and directed. |
| 8 | Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 2.5 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade suitable dia 25mm complete with fittings complete all as specified and as directed. Note:- Two runs of 2.5 Sqmm conductor as main wire and one run of 2.5 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 9 | Supply and Fix Stop Valves, Cast copper alloy, screwed down , high pressure with crutch or butterfly handle , screwed both ends 15 mm bore dia for iron pipe or for unions and fixed complete all as specified and directed. |
| 10 | Supply and lay tubes Medium grade galvanised with all fittings bore of tube 15 mm fixed complete to walls and ceiling or laid in trenches complete all as directed and specified. |
| 11 | Supply and fix Voltage Stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 V with accuracy ±2.5% and speed of correction 8 Volts per second and of capacity 250 KVA, complete all as specified and directed. |
| 12 | Supply, laying, jointing and testing LT Cable in trenches or on poles/walls, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm, 3.5 core, complete all as specified and directed.Note:- 1. Excavation and earth work will be measured and paid separately |
| 13 | M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 14 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender