Tender For Repair And Maintenance Of Internal Wiring, Electrical Fitting And Daily Maintenance Of Electrical Complaints In Md Accn Under Ge (A) Ahmedabad

Issued by Statutory Bodies & Commissions/Committees · Ahmedabad, Gujarat
Tender Value
20 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
15 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmedabad → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Internal Wiring, Electrical Fitting And Daily Maintenance Of Electrical Complaints In Md Accn Under Ge (A) Ahmedabad

BOQ

Name of Work:- REPAIR AND MAINT OF INTERNAL WIRING, ELECTRICAL FITTING AND DAILY MAINT OF ELECTRICAL COMPLAINTS IN MD ACCN UNDER GE (A) AHMEDABAD
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (ARMY) AHMEDABAD NAME OF WORK : REPAIR AND MAINT OF INTERNAL WIRING, ELECTRICAL FITTING AND DAILY MAINT OF ELECTRICAL COMPLAINTS IN MD ACCN UNDER GE (A) AHMEDABAD CONTRACT AGREEMENT: GE (A)/ABD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words)
2Taking down copper/aluminium point wiring ( light, fan, socket or power) complete,incl fixtures and fittings like swithes, ceiling rose, pendant, regulator, sockets, light fitting ( Mirror light,Bulk head,LED Panel 2''x2'',security light,wall fitting,down light,Flood light,post top lantern) etc. removing materials for taking credit and making good disturbed surfaces of walls, floors, etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
3M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One light / ceiling fan / exhaust fan / call bell point controlled by one switch
4M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One 6A socket point controlled by one switch on independent board
5M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of branded pressed galvanised steel terminal box, 60 mm deep with earth dolly of suitable size concealed in wall and modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-One 6A socket point controlled by one switch on same board
6All as per item No. 2.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.
7All as per item No. 2.00 above here in before but wiring in existing conduit for the following :-One light / ceiling fan / exhaust fan / call bell point controlled by one switch
8All as per item No. 2.00 above here in before but wiring in existing conduit for the following :-One 6A socket point controlled by one switch on independent board
9All as per item No. 2.00 above here in before but wiring in existing conduit for the following :-One 6A socket point controlled by one switch on same board
10All as per item No. 6.00 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires.
11M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
12M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
13M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:-4runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire) (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
14Notes for item No. 1.00 to 13.00: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface.(ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
15Supply and fix in replacement of switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed.
16Supply and fix in replacement of socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
17Supply and fix in replacement of switch piano flush type 16 Amps, one way, 240V, 50Hz complete all as specified and directed.
18Supply and fix in replacement of socket 16A & 6A, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed.
19Supply and fix in replacement of electronic socket type fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed.
20Supply and fix in replacement of bell push switch flush type 6 Amps, 240V, 50Hz complete all as specified and directed.
21Supply and fix in replacement of electric call bell ding dong type, AC, 240V, 50Hz complete all as specified and directed.
22Supply and fix in replacement of Modular switch 1 way 6A, 1 module 240V, 50Hz complete all as specified and directed.
23Supply and fix in replacement of Modular Socket, 6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
24Supply and fix in replacement of Modular switch 1 way 16A, 1 module 240V, 50Hz complete all as specified and directed.
25Supply and fix in replacement of Modular Socket 16A/6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
26Supply and fix in replacement of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed.
27Supply and fix in replacement of modular fan regulator step type 240V, 50Hz, compatible for BLDC fan complete all as specified.
28Supply and fix in replacement of Modular Bell push 6A 1 module, 240V, 50Hz complete all as specified and directed.
29Supply and fix in replacement of Modular blank plate 1 module complete all as specified.
30Supply and fix in replacement of ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed.
31Supply and fix in replacement of Lamp holder, angle type with metal ring, PVC/Polycarbonate body type B-22 with back plate, including LED bulb 12 watts complete all as specified and directed.
32Supply and fix in replacement of old unserviceable LED tube light fitting Integral slim LED batten 20 watts with polycarbonate housing and diffuser internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
33Supply and fix in replacement of old unserviceable LED mirror light light fitting Integral slim LED batten Integral 9 / 10 watts of 2 feet long internally prewired complete with all accessories and including connecting up with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed.
34Supply and fix in replacement Decorative wall light fitting, made out of polycarbonate suitable for B-22 base LED lamp including 10 watts LED lamp, full white of approved model fixed on wall and making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed.
35S&F BLDC(Brushless Direct Current) ceiling fans complete with blades, down rods, and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE,including taking out old u/s ceiling fan and deposit to MES store yard complete all as specified and directed.
36Supply and fix in replacement of LED bulkhead luminaire in die-cast aluminium alloy body heat resistant prismatic diffuser, with specially designed gasket for minimum IP 55 degree of protection suitable for and including provision of 10W retrofit LED bulb, full white with B22 lamp holder including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed.
37Supply and fix in replacement of recessed mounted LED panel light 2'x2' size, 36 watts, full white / warm white as per site requirement with electronic driver in CRCA sheet steel body with polycarbonate diffuser suitable for POP / Amstrong / grid false ceiling complete with all fixing accessories including making electrical connection with pvc insulated and pvc sheathed twisted two core wire of suitable size complete all as specified and directed.
38Supply and fixing of Exhaust Fan AC single phase 230Volt of size 300 mm sweep, high speed, energy efficient exhaust fan for kitchen (Metallic body finish) including making circular hole in wall of suitable size and grouting fastener with nut & washer-04 nos for installation of exhaust fan including providing the electrical connection with PVC insulated and PVC sheathed copper flexible cable of size 1.0 sqmm 3 core up to the ceiling rose complete all as specified and as directed.
39Supply and fix in replacement of sleek round recessed cum surface mounting LED down light 12 W, 3-in-1 color type with aluminium die-cast body, finish with drop down PC diffuser with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed.
40Supply and fix in replacement of old unserviceable recess mounting light fitting of capacity 18 Watts powder coated white CRCA full glow suitable for 220 x 220 mm square POP false ceiling including making electrical connection from ceiling rose to light fittinf complete all as specified and directed.Make : Crompton Cat No- LCTLRNE-18-FO-CDL, Havells Cat No-VENUSNEO2X2PLR18WLED857STTR, Eveready Cat No- LEDDNRS01816
41Supply and fix in replacement of ventilating / PVC exhaust fans 150mm Sweep fancy square type with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed:
42Supply and fix in replacement of ventilating / PVC exhaust fans 200mm Sweep fancy square type with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed:
43Supply and fix in replacement of ventilating / PVC exhaust fans 250mm Sweep fancy square type with plastic fiber body heavy duty 230 Volt AC, single phase complete with plastic louvers and including making suitable size of holes in wall for fixing the fan including making electrical connection with ceiling rose including taking down existing unserviceable ventilating fan of any description complete all as specified and directed:
44M&L for dismantling of ceiling fans of sizes 1200mm/1400mm (collected from MES fan store ) any make / model except old vintage, dismantled its stator,rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots and providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, screws etc as required complete all as specified and directed.
45All as per item no. 44 above but for exhaust fan of following sizes :-450mm sweep
46All as per item no. 44 above but for exhaust fan of following sizes :-300mm sweep
47All as per item no. 44 above but for exhaust fan of following sizes :-230mm sweep
48S&F in replacement of fan blade suitable for 1200mm sweep ceiling fan complete similar to original make with new screws Complete all as specified and directed .
49All as per item No.48 above but 1400mm sweep.
50S&F Fan condenser, 220 volts of the following sizes :-2.5 mfd
51S&F Fan condenser, 220 volts of the following sizes :-3.15 mfd
52S&F Fan condenser, 220 volts of the following sizes :-4 mfd
53S&F ball bearing of following sizes :-NBC/ SKF - 6201'ZZ'
54S&F ball bearing of following sizes :-NBC/ SKF - 6202'ZZ'
55S&F ball bearing of following sizes :-NBC/ SKF - 6203'ZZ'
56S&F ball bearing of following sizes :-NBC/ SKF - 6204'ZZ'
57M&L for Spray Painting of ceiling fan with two coat synthatic enamel paint after surface preparation including Writing/making of MES No complete all as specified and directed.
58Supply and replacement down rod for ceiling fans duly painted with synthetic enameled paint 3 feet long 19 mm outer dia including making required holes on both side of the rod suitable for hanging of the ceiling fan complete all as specified and directed.
59All as per Item No- 47 but of length 2 feet long complete all as specified and directed.
60Dismantling of cabin fan of any sweep and overhauling complete by means of cleaning of stator, oiling & greasing including replacement of nut and bolt etc and reassembling the same and testing complete all as specification and directed .
61Dismantling of cabin fan 400mm and rewinding the stator with super enameled copper winding wire of suitable size including greasing, cleaning of all components of fan reassembling , testing, commissioning including taking out u/s cabin fan from site and refixing back the same on exisitng location complete all as specification and directed.
62Supply and fix in replacement of LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.00m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core pvc insulated and pvc sheathed twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
63Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
64Supply and fix in replacement of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately.
65Supply and fix in replacement of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface including taking down existing unserviceable MCB DB of any description complete all as specified and directed. Note: MCBs shall be measured and paid separately.
66All as per item No. 65 here-in-before but SPN, 12 way, 230 V, 1 phase, ACNote: MCBs shall be measured and paid separately.
67All as per item No. 65 here-in-before but SPN, 8 way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
68All as per item No. 65 here-in-before but SPN, 4 way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
69Supply and fix MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release fixed in Vertical TPN complete all as specified and directed.
70Supply and fix in replacement of MCB 100A, 10 KA, TPN, 'C' curve, 415 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
71Supply and fix in replacement of MCB 40 - 63A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
72Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
73Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size any size from 5\\" X 5\\" to 9\\" X 11\\" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with new brass/GI screws and washers complete all as specified and directed.Note: S&F of switches, sockets & regulators shall be measured and paid separately. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56370306
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Internal Wiring, Electrical Fitting And Daily Maintenance Of Electrical Complaints In Md Accn Under Ge (A) Ahmedabad
Basic Detail
Tender No 8358/E8
Bidding Type Tender
Location
City Ahmedabad
State Gujarat
Key Dates
Publish Date 08 Jul 2026
Submission Date 27 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
BOQ_870201.xls
c78d2da0-cee4-44fd-90db-fb5c1d330dce.html
TENDER8358.pdf
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_870201.xls

html

c78d2da0-cee4-44fd-90db-fb5c1d330dce.html

pdf

TENDER8358.pdf

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders