BOQ
| Sl. No. | Item Description |
| 1 | Dismantling the existing Burner assembly of heating plant of capacity 2 Lakh Kcal/ hr for repairs and replacement of coupling for blower and motor of burner assembly and refixing the same position including testing, complete all as specified and as directed by Engineer-in-charge. |
| 2 | Dismantling the existing Boiler assembly of heating plant of capacity 2 Lakh Kcal/ hr for de- carbonazation , Descaling and refractory cement and assemble the same and testing, complete all as specified and as directed by Engineer-in-charge. |
| 3 | De- carbonazation of Boiler assembly of heating plant, complete all as specified and as directed by Engineer-in-charge. |
| 4 | Descaling of Boiler assembly of heating plant, complete all as specified and as directed by Engineer-in-charge. |
| 5 | Refractory cement / heat resistance cement of Boiler assembly of heating plant complete all as specified and directed. |
| 6 | S&F in repair of ball cock valve heavy duty made out of gun metal of size 20mm x 5/8'' , complete all as specified and as directed by Engineer-in-charge. |
| 7 | Supply And Fixing in replacement of Solenoid Valve suitable for burner heating plant of capacity 2 Lakh Kcal/hr RAPID THERM Boiler complete all as specified and directed. |
| 8 | S&F in repair of photo cell sensor suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. Make - COFI |
| 9 | S&F in repair Hydraulic Pressure gauge showing reading 0-20 bar with accuracy +/- 2.5% to be connected with 15 mm dia GI Pipe complete with suitable size of battery complete all accessories and protection cover, complete all as specified and as directed by Engineer-in-charge. |
| 10 | S&F in repair Digital Temperature Controller (DTC) suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. |
| 11 | Supply and fixing in repair of ignition Electrode suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. |
| 12 | Supply and fixing in repair of igintion Transformer suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. |
| 13 | Supply and fixing in repair of Fuel feed pump with indicator suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. |
| 14 | S&F in repair of Nozzel 60 degree, complete all as specified and as directed by Engineer-in-charge. Make : Danfoss or equivalents make. |
| 15 | Replacement of old unserviceable minor part for the control panel including repairing of wiring etc as per existing , complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F in repair ON/OFF selector switch with indicator suitable for burner heating plant 2 Lakh Kcal Boiler RAPID THERM Boiler, complete all as specified and as directed by Engineer-in-charge. |
| 17 | Supply and fix in repair Thermostat suitable for burner heating plant of capacity 2 Lakh Kcal/hr RAPID THERM boiler complete all as specified and directed. |
| 18 | Supply & Fix in repair of Sequence controller complete all as specified and as directed by Engineer-in-charge (Model LO24, Siemens or equivalent make) |
| 19 | S&F in repair Contactor 25A, 230V/440V suitable for 2 Lakh Kcal Boiler RAPID THERM Boiler including testing, complete all as specified and as directed by Engineer-in-charge. Model No - CA 3-16 of L&T or equivalent in approved make. |
| 20 | S&F in repair of Contactor 230/ 440V including testing , complete all as specified and as directed by Engineer-in-charge.. Model No - MNX 12 of L&T or equivalent in approved make. |
| 21 | S&F in repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 HZ, 415 Volts suitable for 2 Lakh Kcal Boiler RAPID THERM Boiler including testing , complete all as specified and as directed by Engineer-in-charge. Model No - MN 2 of L&T or equivalent in approved make. |
| 22 | S&F in repair Relay 6 - 10 Amps,3 Phase, 50HZ, 415 Volts including testing, complete all as specified and as directed by Engineer-in-charge. Model No - MN 2 of L&T or equivalent in approved make. |
| 23 | S&F in repair Diesel filter Assembly with drain port complete as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 24 | S&F in repair fuel pipe for burner as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 25 | S&F in repair brass air release valve of 15 mm dia to be connected on 15 mm dia threaded GI Pipe as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 26 | Rewinding of Motor winding of capacity 1.5 HP to 2 HP 3 phase 415 Volts with suitable size super enameled copper wire and insulation as per existing gauge and rating, and fixing with pump, suitable size of key and coupling complete all as specified and directed by Engr-in-Charge. |
| 27 | Taking out the radiator unit from the location and Cleaning of grills / difusers with high pressure blower and refixing the same including replacement of gasket, identify and rectify leakage and necessary insulation where required, complete all as specified and as directed by Engineer-in-charge. |
| 28 | Supply, installation & testing in repair of compressor unit, suitable for 165 ltr capacity refrigerator, complete all as specified and as directed by Engineer-in-charge. |
| 29 | Supply & Fix in repair of thermostat for refrigerator of cap 165/360/500 ltr, complete all as specified and as directed by Engineer-in-charge. |
| 30 | Supply and Re-filling of Refrigerant gas for refrigerator of cap 165 ltr, complete all as specified and as directed by Engineer-in-charge. |
| 31 | Repair to Voltage stabilizer for automatic operation single phase naturally air cooled, indoor type designed for output variation between 170 to 250 V with output voltage stablized at 230 V with accuracy of + 2.5 % and capacity 1/2/3 KVA and making connection with AC , complete all as specified and as directed by Engineer-in-charge. |
| 32 | Supply & Fixing in repair of inner shell made of stainless steel 1.5mm thick suitable for Geyser inclusive of glass wool as an insulating material for geyser of capacity 15-25 Ltrs, complete all as specified and as directed by Engineer-in-charge. |
| 33 | Supply & fixing in repair of Thermostat for geyser 0 to 80˚ C, complete all as specified and as directed by Engineer-in-charge. |
| 34 | M&L in repair of flexible PVC connection pipe for geyser of length 450mm as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 35 | Supply & Fixing in repair of pressure release valve for geyser of 25 ltr having size 15mm dia, complete all as specified and as directed by Engineer-in-charge. |
| 36 | Supply & Fixing in repair of heating element for 25 ltr cap Round type 1.5 Kw, complete all as specified and as directed by Engineer-in-charge. |
| 37 | Supply & Fixing in repair of heating element for 25 ltr cap Triangle type 1.5 Kw suitable for Hamam/Food warmer/Geyser as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 38 | Supply & Fixing in repair of Geyser assembly suitable for 25 litre Geyser as per sample, complete all as specified and as directed by Engineer-in-charge. |
| 39 | M&L for repair of kerosine oil batti including blower, burner for Hammam as per sample complete all as specified and directed. |
| 40 | S&F in replacement of Brass Tap size 15/20mm for Hamam as per sample complete all as specified and directed. |
| 41 | S&F in repair of compressor new sealed unit, suitable for 320 litre capacity deep freezer and testing on full load complete all as specified and as directed by Engineer-in-charge. |
| 42 | S&F in repair of compressor new sealed unit, suitable for 500 litre capacity deep freezer and testing on full load complete all as specified and as directed by Engineer-in-charge. |
| 43 | Supply and Re-filling of Refrigerant gas as per existing for deep freezer of capacity 320 ltr to 500 ltr and detecting leakage and rectified the leakage, complete all as specified and as directed by Engineer-in-charge. |
| 44 | Dismantling of 3 phase electric induction motor of any make and type and removing the old burnt copper winding wire from 3 HP to 5 HP motor and rewinding with existing gauge of super enamelled copper winding wire including refixing in its original position and testing complete all as specified and as directed by Engineer-in-charge |
| 45 | M&L charges for servicing of Air Handling Unit (AHU) including Blower cleaning, balancing of blower motor pully complete all as specified and directed |
| 46 | Dismantling of unserviceable HEPA Filters and supply, fixing of HEPA Filters with Al box and flange type of size 610 x 610 x 310 mm with frame having efficiency of 3 microns, complete all as specified and as directed by Engineer-in-charge. |
| 47 | Supply and topping up of Antifreeze (Coolant) suitable for - 35 to - 40 degree celsius to be filled in reservoir tank for central heating system, complete all as specified and as directed by Engineer-in-charge. |
| 48 | Supply and Fixing of Elastomeric Nitrile rubber foam insulation sheet for ducts having anti microbial properties having thickness 10 mm with suitable adhesive, including taking out old Nitrile Foam complete all as specified and as directed by Engineer-in-charge. |
| 49 | Supply and Fixing in repair of Copper tube of size 1/4 inch for refrigerator and deep freezeer, complete all as specified and as directed by Engineer-in-charge. |
| 50 | Supply and Fixing in repair of Copper capillary tube with all fittings for deep freezeer of cap 320 litre, complete all as specified and as directed by Engineer-in-charge. |
| 51 | Supply and Fixing in repair of Copper capillary tube with all fittings for refrigerator of cap 160 litre, complete all as specified and as directed by Engineer-in-charge. |
| 52 | Supply and fixing in repair of heating bank for electric boiler suitable for burner heating plant 5x446 Kcal/hr Boiler RAPID COOL boiler, complete all as specified and as directed by Engineer-in-charge. |
| 53 | Supply & Fix in repair of Relay PCB board for electric boiler suitable for burner heating plant 5x446 Kcal/hr Boiler RAPID COOL boiler, complete all as specified and as directed by Engineer-in-charge. |
| 54 | Supply & Fix in repair of thermostat for electric boiler suitable for burner heating plant 5x446 Kcal/hr Boiler RAPID COOL boiler, complete all as specified and as directed by Engineer-in-charge. |
| 55 | Supply & Fix in repair of Switch Disconnector Fuse Unit 63 Amp, TPN 440V, AC 50Hz for electric boiler ,suitable for burner heating plant 5x446 Kcal/hr Boiler RAPID COOL boiler, complete all as specified and as directed by Engineer-in-charge. |
| 56 | Supply & Fix in repair of Fuse 63 Amp for electric boiler ,suitable for burner heating plant 5x446 Kcal/hr Boiler RAPID COOL boiler, complete all as specified and as directed by Engineer-in-charge. |
| 57 | Dismantling the existing electric boiler of heating plant of capacity 5x446 Kcal/ hr for repairs and replacement of electric heater and general servicing including checking of panel and connecting items motor of burner assembly PCB etc and refixing the same position including testing, complete all as specified and as directed by Engineer-in-charge. |
| 58 | Dismantling the existing radiator unit of capacity from 3000 to 6000 K Cal per hour, taking it to nearest workshop cleaning the complete unit with coil shine chemical, detecting the leakage protion by applying nitrogen gas pressure, brazing the leakage protion, refixing the same unit from dismantled location including testing on load complete all as directed at site by Engineer-in- Charge. |
| 59 | S&F in Repair / replacement of fan coil unit parts, dual shaft electric motor of capacity 30 watt 930 RPM, 3 speed as per existing, complete all as specified and directed. |
| 60 | S&F in repair of FCU connection of copper pipe 20/16 mm with check nut at both side as per required length, complete all as specified and directed. |
| 61 | S&F in repair of needle valve 3/8\\" BSP as per existing, complete all as specified and directed. |
| 62 | S&F in repair of temp controller regulator type , complete all as specified and directed. |
| 63 | S&F in repair of inlet outlet Ball valve 3/4\\" for FCU as per existing, including supply and fixing MS / GI nipple of size 3/4 inch includig welding work including cutting the existing rusty unserviceable MS/GI nipple complete all as specified and directed. |
| 64 | Supply & Fixing in repair of radiator unit of capacity from 3000 to 6000 K Cal per hour, including taking down old unsv radiator complete all as directed at site by Engineer-in- Charge. |
| 65 | S&F in repair of Inlet/outlet ball copper valves set of 1/4\\", complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F in repair of Pipe fitting of brass (Nipple outer thread) 1/4\\" size, complete all as specified and directed by Engr-in-Charge. |
| 67 | S & F in repair of ring clip of flexible PVC pipe of existing size all as specified and directed. |
| 68 | M&L for cleaning of bulk oil (diesel) tank cap 10000 Ltr by dismantling all connected parts and making leak proof by welding and refixing the same at its original position and connecting all desmantled parts and testing the same complete all as specified and directed by Engr-in-Charge. |
| 69 | M&L for cleaning of day oil (diesel) tank cap 1000 Ltr by dismantling all connected parts and making leak proof by welding and refixing the same at its original position and connecting all desmantled parts and testing the same complete all as specified and directed by Engr-in-Charge. |
| 70 | S&F in replacement of AHU fan motor belt as per sample complete all as specified and directed. |
| 71 | M&L in repair of factory made retro reflective sign board 2 mm thick aluminium sheet plate of size 1200X800 mm in 40 mm bore stainless steel pipe frame incl legs with aluminium/stainless steel rivets and flats of suitable size . The plate to be provided with comprised cut directional arrows,alphabets,lines & symbols etc with white colour reflective tape with font size and thickness as directed over dennison HIP base green reflective background sheets. Top height of the boards with legs from ground level as decided by engr in charge including embeding in PCC 1;2;4 type b-1 blocks of size 45X45X60 cm including excavation, taking out old board (any type and size) all as per sample approved by GE. |
| 72 | M&L for repair of Bulk oil tank 10000 Ltr steel with glass wool fibre insulation and covered with cement plaster complete by removing old layer of damaged cement and glass wool fibre insulation and supply and fix new insulation and cement plaster with same material as per exesting all as specified and directed. |
| 73 | M&L for preparation of surface by removing old paint by scrapping with scrap paper/ sand paper and applying two coat of synthetic enamel paint as per the existing colour on Boiler, Bulk Oil Tank, Day Oil Tank etc complete all as specified and as directed. |
| 74 | M&L for cleaning and internal inspection of ducting of central heating system by advance robotic duct cleaning machine including camera based inspection, brushing, vacuuming and removing of dust, debris and microbial contaminants from inside surface of ducts, bends, joints and diffusers, complete pre and post cleaning inspection (camera based) alongwith ensuring hygienic and contamination-free duct system all as specified and directed by Engr-in-Charge. |
| 75 | M&L for Repair and servicing of steam generator associated with Air Handling Unit (AHU) including connection of steam lance with required accessories and making hole into the ducts of suitable size and cleaning, replacement of damaged parts, connection of pipe with insulation to the system either AHU/Ducts including connection of water inlet drain and electrical control wiring, ensuring proper humidity control operation with testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 76 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 30,373.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender