Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56370253

Tender For Repair/ Replacement Of Solar Water Heaters, Solar Panel, Dg Set, Security Light, Lightening Conductor, Street Lights, Junction Box, Street Light Timer And Repair/ Renewal Of Air Conditioner, Refrigeraton, Deep Freezers And Other Coonected

Issued by Statutory Bodies & Commissions/Committees · Solan, Himachal Pradesh
Tender Value
36.62 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
16 days left
EMD
73240
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Solar Water Heaters, Solar Panel, Dg Set, Security Light, Lightening Conductor, Street Lights, Junction Box, Street Light Timer And Repair/ Renewal Of Air Conditioner, Refrigeraton, Deep Freezers And Other Coonected Works At Kasauli & Dagshai Under Ge Kasauli.

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF SOLAR WATER HEATERS, SOLAR PANEL, DG SET, SECURITY LIGHT, LIGHTENING CONDUCTOR, STREET LIGHTS, JUNCTION BOX, STREET LIGHT TIMER AND REPAIR/ RENEWAL OF AIR CONDITIONER, REFRIGERATON, DEEP FREEZERS AND OTHER COONECTED WORKS AT KASAULI & DAGSHAI UNDER GE KASAULI.
Sl. No. Item Description
1Schedule 'A' Section - I
2Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
3Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
4Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
5Material and labour for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed.
6Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
7Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 Sqmm 2 core with required aluminium cable lugs all as specified and directed.
8All as per item No. 6.00 here-in-before but 10 Sqmm 2 core complete all as specified and directed.
9All as per item No. 6.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed.
10Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and light grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete all as specified and directed Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
11Supply and fixing GI tubing light grade 50mm bore, ISI marked, for cable protection in road crossing all as specified and directed.
12Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 4.0 sqmm and overall PVC sheathed to pass through the street light pole from junction box to street light fitting incl dismantling taking down unserviceable one all as specified and directed.
13Supply and fixing 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6.0 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart including 4mm suspension GI wire from OH conductor to building incl dismantling taking down unserviceable one all as specified and directed.
14All as per item No. 12.00 here-in-before but 10 Sqmm complete all as specified and directed.
15Material and labour for painting of steel tubular pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate white and black paint strip 30 cm wide (5 Nos) with synthetic enamelled paint all as specified and directed.
16Dismantling / taking down carefully flood/street/gate light fittings of any type, any make and any capacity from Pole/Building for repair or for fixing in other position complete all as specified and directed.
17Supply and fixing in replacement LED 48/50 watts street light fiitting made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection incl complete fixed to pole/wall with necessary MS clamp accessories complete all as specified and directed.
18Supply and fixing of 45 watts Inverter type LED Street Light with IR Sensor for automatic ON/OFF of street lights and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be pressure die cast and system efficiency >100LPW,CRI >70,CCT 5700K ,PF > 0.9, THD<15% .
19Supply and fixing Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismantling taking down unsv complete all as specified and directed.
20Supply and fix in replacement of sintex box thermo plast (weather proof) IP 66, on street light poles made out of thermoplastic of size 300mm x 200 mm x 105 mm size with connector for connecting incomming and outgoing of cable including 01 No of MCB DP 06 Amps to control the pole light circuit and MS brackets made out of 32 x 4 mm flats for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incomming, outgoing of cable Complete all as specified and directed by Engr-In-Charge.
21Supply and fixing in replacement of 200 watts flood light Warm white/ coolday light in colour as per rquirement, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information
22Supply and fixing in replacement of 200 watts flood light Warm white/ coolday light in colour as per rquirement, LM6 aluminium or higher grade powder coated and water proof pressure die cast aluminium enclosure, with inbuilt electronic drivers and IP 66 protection complete ,Single phase, etc fixing in MS chanel by drilling hole of suitable , size, using nut, bolts and washers of suitable size including suitable mounting structure on existing pole as reqd at the site complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56370253
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36.62 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Solar Water Heaters, Solar Panel, Dg Set, Security Light, Lightening Conductor, Street Lights, Junction Box, Street Light Timer And Repair/ Renewal Of Air Conditioner, Refrigeraton, Deep Freezers And Other Coonected Works At Kasauli & Dagshai Under Ge Kasauli.
Basic Detail
Tender No GEK-16/2026-27
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 08 Jul 2026
Submission Date 28 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value 36.62 Lakhs
Tender Fee 500
EMD 73240
Exemption Available
Document List
46a28937-671b-4b4c-bf1e-6be2b79eae4c.html
BOQ_870395.xls
GEK162627.pdf
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

46a28937-671b-4b4c-bf1e-6be2b79eae4c.html

xls

BOQ_870395.xls

pdf

GEK162627.pdf

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders