Water Resources and Irrigation Government Departments Closing in 8 days TDR #56370138

Tender For Providing Lis To Village Khateta, Johri In Gp Maan In Tehsil Arki District Solan Hp (Sub Head:- Construction Of Pump House I/C Electrical Works, Construction Of Sumpwell 50000 Litrs Capacity, Main Storage Tank / Mdt 50000 Liters Capacity ,

Issued by Government Departments · Solan, Himachal Pradesh
Tender Value
1.02 Crore
Estimated cost
Bid Submission
20 Jul 2026
8 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Lis To Village Khateta, Johri In Gp Maan In Tehsil Arki District Solan Hp (Sub Head:- Construction Of Pump House I/C Electrical Works, Construction Of Sumpwell 50000 Litrs Capacity, Main Storage Tank / Mdt 50000 Liters Capacity , Intake Well, Laying, Jointing, Testing Of Gms Pipe In Rising Main Conforming To Is (1239-Part-I) Of 150 Mm Dia, Laying, Jointing And Testing Of Gms Pipe Conforming To Is-1239 (Part-1) Of Dia 125Mm (Mg) And Laying, Jointing And Testing Of Hdpe Pipe Conforming To Is 4984-2016 In Distribution System Construction Of Field Out Let, Assemblies Supply, Erection And Testing Of Submersible And Centrifugal Pumping Machinery Along With Allied Accessories And Construction Of Retaining Wall And Boundary Wall Around The Pump House).

BOQ

Name of Work:- Providing LIS to village Khateta, Johri in GP Maan in Tehsil Arki District Solan HP (Sub Head:- Construction of pump House i/c electrical works, construction of Sumpwell 50000 litrs capacity, Main Storage Tank / MDT 50000 liters capacity , intake well, Laying, jointing, testing of GMS pipe in rising main conforming to IS (1239-Part-I) of 150 mm dia, laying, Jointing and testing of GMS Pipe conforming to IS-1239 (Part-1) of dia 125mm (MG) and laying, jointing and testing of HDPE pipe conforming to IS 4984-2016 in distribution system construction of field out let, assemblies Supply, erection and testing of submersible and centrifugal pumping machinery along with allied accessories and construction of retaining wall and boundary wall around the pump house).
Sl. No. Item Description
1Cutting in earth work and disposal of excavated earth upto a lead of 20 metres in Pick and Jumper work 50% each
2Excavation work by mechanical means ( Hydroulic excavator)/ menual means in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing of pumping out water, blasting soft/hard rock where blasting is prohibited. In all lifts including trimming and dressing of sides, levelling of beds to correct grade i/c shoring, strutting, planking timbering and dewatering wherever required, stacking the usable and un-useable material / soil separately and after laying, jointing of pipes returning the useable soil in trenches in trenches in 15 cm (fifteen centimeters) layers including consolidating of each of each deposited layer by ramming and watering and disposing of all surplus excavated soil un useable materials as directed within all leads & lifts including restoration of un-metalled surfaces to its original condition and including cost of diverson for traffic night signals, fixing caution boards, crossing over trenches for excess to houses, fencing etc.complete in all respect with in all leads & lifts as per the direction of the Engineer-in-charge.
3Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, in all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within all leads and lifts in all kinds of soil complete in all respect and as per the direction of and to the entire satisfaction of the Engineer in charge..
4Excavation in foundation for digging well in dry excavation from G.L.upto the level,where well curb is placed from natyral surface to 1.50 metre depth.
5Wet well sinking gravel including all pumping,soring etc.and as per the direction of Engineer-in-charge.
6From spring level to 3.00 mtr.depth below S.L
7From spring level to 3.00 metre to 6.00 Mtr. Depth S.L
8Providing and laying cement concrete 1:5:10 ( I cement : 5 sand : 10 graded stone aggregate 40 mm nominal size)and curing complete excluding the cost of form work in foundation and plinth including carriage of material in all leads & lifts and as per the direction of the Engineer-in-charge. .
9Providing and laying cement concrete 1:4:8 ( I cement : 4 sand : 8 graded stone aggregate 40mm nominal size)and curing complete excluding the cost of form work in foundation and plinth including carriage of material in all leads & lifts.
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3 : 6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
111st class Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:- Cement mortar 1:6 (1 cement : 6 coarse sand) complete in all respect and as per the direction of Engineer in charge.
12Frist class Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)complete in all respect and as per the direction of Engineer in charge.
13Providing Centering and shuttering including strutting, propping etc. and removal of form for all heights Suspended floors, roofs, landings, balconies and access platform. with waterproof ply 12 mm thick and string courses and like complete in all respect and as per the direction of Engineer in charge.
14Beams, cantilivers, girders and lintels sides and soffits of beams,beam haunchings cantilivers, girders, bressumers and lintels not exceeding 1 metre in depth in all leads and lifts.
15Vertical surfaces such as walls (any thickness), partitions and the like including attached pillasters, buttress,plinthand string courses and the like in all leads and lifts.
16Providing form work of ordinary timber plankings so as to give a rough finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plaiin concrete work in:-
17Arches, domes, vaults up to all span in all leads and lifts.
18Providing and laying machine batched and machine mixed cement concrete of design mixed M30 grade for reinforced cement concrete work using cement content as per approved design mix including pumping of concrete to site of laying but excluding the cost of centering, shutring, finishing and reinforcement, including admatures in recomended preperation as per IS: 9103 to accelerate, seterd setting of concrete, inprove workability without imprecing strength and durability as per direction of Engineer-in-charge. (Note:-Cement contant considered in this item @ 340 Kg/cum excess and less cement used as per design mix is payable/recoverable separately).
19All work upto plinth level
20Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum. All works above plinth level upto floor V level).complete in all respect and as per the direction of Engineer in charge.
21Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum. All works up to plinth level.
22Providing & Laying no fine concrete 1:4 (1cement : 4 stone aggregate) complete in all respect including carriage of material in all leads & lifts.
23Providing and Placing Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. including carriage of material in all leads & lifts complete in all respect and as per the direction of Engineer in charge.
24Prov. and fixing MS man hole cover of size 600 x 600 mm made up of 3.15 mm thick plain MS sheet fixed in angle iron frame frame of 50x50x5mm supported with MS flat of 50x5mm at center of sheet including fising hold fast ,hinges and locking arrangement and lock of medium size etc complete in all respects.
25Providing 200 mm wide CI rungs with chequered or ribbed non slip surface i/c fixing in structure with 200 x 200 x 100 mm cement concrete 1:3:6 ( 1 cement :3 sand : 6 graded stone aggre 20 mm nominal size )
26Laying, jointing and testing of galvanised MS pipe conforming to IS1239- part -II of following diameter and wall thickness i/c fittings in trenches flanged jointed with table 5 complete in all respect
27Outlet pipe :- 125 mm dia.
28Inlet pipe i/c bypass arrangement :- 150 mm dia
29Scour pipe :- 150 mm dia.
30Providing and fixing C.I. Sluice valve (with hand wheel) as per IS:14846-2000 complete with bolts, nuts, rubber insertion etc,(The tail pieces if required shall be measured and paid for separately)
31Inlet valve / for by pass :- 150mm dia & scour valve
32Outlet valve :- 125 mm dia
33Steel work welded in built up sections,trusses and framed work including cutting,hoisting, fixing in position and applying a priming coat of red lead paint :- in gratting, framed guard bar, ladders, railing brackets and similar works in all leads and lifts.
34Providing and fixing 0.60 m high ventilation arrangement in 500mm dia at top of dome with 6 Nos. 20mm MS square bar duly welded in 20mm MS square bar and bottom. The circular frame at bottom edge should be properly welded with reinforcement bar of circular frame of 500mm dia both top Dome. The circular ventilation frame should be enclosed with mosquito proof wire mesh. Roofing over ventilation should be provided with Plain galvanized sheet after fixing it with sloped bar so as to avoid rain water inside the tank complete in all respect as per entire satisfaction of Engineer in charge.
3515 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:4 ( 1 cement : 4 sand ) including all leads and lifts and as per the direction of the Enginner-in-Charge.
36P/ F pressed steel door frames manufactured from commercial MS sheets of 1.25mm thickness including hinges, jump lock jamp. Bead and if required angle threshold of MS angle 50 x 25 mm or base tie of 1.25mm pressed MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamp i/c steel butt hinges 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of steel primer after pretreatment or surface as directed by Engineer-in-charge.
37Profile---\\"B\\"
38Profile---\\"C\\"
39Providing and fixing 1mm thick M.S.sheet door with frame of 40mmx40mmx6mm angle iron 3.15mm M.S. gusset plate at the junctions and corners including all necessary fittings, complete including applying a priming coat of red lead paint.using flat 30mm x6mm for diagonal braces and control cross/pieces.complete in all respect and as per the direction of Engineer in charge.
40Filling in plinth with sand under floors including watering ramming consolidating and dressing complete. in all leads and lifts as per the direction of the Enginner-in-Charge.
41Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate including carriage of materials with in all leads and lifts.and as per direction of the Engineer-in-Charge.
42Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. complete in all respect.including entire carriage of material and as per direction of the Engineer-in-Charge.
43Providing and applying Birla white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.and as per direction of the Engineer-in-Charge.
44Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer and as per direction of the Engineer-in-Charge.
45Finishing with Deluxe/ Apex Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture and as per direction of the Engineer-in-Charge.
46Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.complete in all respect.
47Painting two coats(excluding priming coat) on new steel work based surfaces,with ready mixed paint,brushing to give an even shade including cleaning of all dirt,dust and other foreign matter,sand papering and stopping,with paint other than white..complete in all respect.
48Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
49Providing and fixing M.S. grills of required pettern in windows frames of windows etc. with M. S. Flats Square or round bars with round headed bolts and nuts or by screws. (Plain grill) Fixed to openings /wooden frames with rawl plugs screws etc.complete in all respect.
50Providing & fixing M.S. gate of angle iron and flat 6 mm thick with frame I/c locking arrangment andplacing in position complete i/c carriage of materials with in all leads and lifts.
51Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked of suitable capacity of 500 Ltrs, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. complete in all respect.
52P/F vitreous china wash down water closet squatting pan (Indian Type WC pan) size 580 mm (Earth work, bed concrete, foot rest and tap should be measured and paid for seprately (Orissa Pattern) complete in all respect and entire satisfaction of Engineer in charge.
53P/F high pressure PVC spigot and soaket, waste and ventilating pipes ISI marked i/c fixing with approved adhesive etc. complete 110 mm dia
54Providing and fixing PVC trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet
55P/F brass bib tap (Superior or heavy type) of 15 mm dia
56Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall
57Providing and fixing Fittings and accessories ( Horizontal) complete in all respect and as per the direction of Engineer-in-charge. (HDPE fittings).
5875 mm dia PN 4 /5/6/8 HDPE pipes.
59Reducing HDPE equal TEE 110 x 110 x 110
60Reducer 110 x 75
61Providing and fixing Fittings and accessories ( Vertical) complete in all respect and as per the direction of Engineer-in-charge. (GI fittings)
6265 mm dia G.I pipes.
6340 mm dia G.I Elbow
6440 mm dia G.I TEE
6540 mm dia G.I Nipple ( 6\\" lenhth).
6665mm dia X 40 mm dia G.I unequal Tee.
6765mm dia Union.
6865mm dia G.I Elbow.
69Providing and fixing of 40 mm dia GM Wheel valve IS 778-1984 of reputed make such including entire carriage of material complete in all respect and as per the direction of Engineer-in Charge.
70Laying, jointing, testing and commissioning at site in trenches GMS tube (Medium & Heavy grade) of following dia meters for rising main as under conforming to BIS 1239 part-I or latest wih upto date amendments, capable of withstanding required test pressure as prescribed in BIS code in random length of 5.50 to 6.50 metres including specials, short pieces, bends, reducer, Tee etc. made from parent tube. The joiniting of pipes shall be done with butt welded joints, MS flanges are to be provided in 1% of total joint and remaining 99% joint shall be provided with butt welded joints. The pipe end shall be bevelled suitable for butt welding conforming to IS- 816-1969 or latest wih upto date amendments as applicable to make joint leak proof in two layers at site of work with electrod as per IS 814-2004 or latest wih upto date amendments. The laying of pipes should be conform to BIS code 5822-1994 or latest wih upto date amendments and shall i/c the cost of all operation such as cutting, welding, DP test of butt welding joints , jointing making pipe bevelled for butt welded joints, fabrication of bend, Tees, valve etc. i/c lowering and laying in excavted trenches to ensure required level i/c flushing, cleaning and hydraulic testing complete in all respect and carriage of materials at site in all leads and lifts as per the directed by Engineer-in Charge.
71Nominal dia Thickness Class
72150 mm 5.40 GMS 1239 Heavy P.E
73150 mm 4.80 GMS 1239 Heavy P.E
74125 mm GMS (M)
75Providing and fixing M.S plate flanges of following dia @ 1% of total joint, conforming to following table as per IS 6392- 1971 (latest upto date amendments) and welding of MS flanges with GMS tube in three layers (two layers on outer face and one layer on inner face) to make joint leakproof with required numbers and size of nut bolts conforming to BS 1364 (latest upto date amendments), The welding of flanges should conform to IS 816-1969 with electrode as per IS 814-1994 ( the cost for laying and jointing of GMS pipe and butt welded joint, to be measured and paid for seprately) The thickness of gaskit ( champion sheet) should not be less than 3 mm thick conforming to IS 2712-1998 or latest upto date amendments complete in all respect and carriage of materials at site in all lead and lifts as directed by Enginer-in-charge.
76Nominal dia flange Table
77150 mm 28
78150 mm 17
79150 mm 5
80125 mm 5
81Laying, jointing and commissioning of HDPE (High Density Polyethylene pipes) of following diameter and class confirming to IS 4984-2016 with fusion welding process including all necessary fittings & bends in all leads and lifts to the entire satisfaction of Engineer-in-charge.(Earth work in trenches to be measured and paid separately).
82HDPE pipe 110 mm dia PN 4.0 PE 80/SOR-26
83SUBMERSIBLE
84Supply, erection, testing & commissioning of submersible/ mono submersible pump for open well pumping set of reputed make such as KSB/ BS/Johnston / Clama/ SU/ Kirloskar or any other state/ department approved make conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per IS 14220 or latest with up to date ammendments suitable for raw water having greased packed bearings & shaft with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a siutable submersible energy effecient motor of minimum effeciency level IE-2 dule cage electric Induction motor of Kirloskar/ NGEF/ Jyoti / Crompton / BHEL/ GEC/ SIEMENS/ ABB/ MATHER & PLATmake conforming to relevent BIS code compatible with pump with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- From P/Well to S/Well.
85Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 33.56
86Capacity (in LPS) of each pump set. 16.57
87Dia of R/Main (in mm) 150.00
88Dia of riser pipe (in mm) 150.00
89Length of R/Main. 120.00
90SITE CONDITIONS:-
91Location of Site:- GAMBHAR KHAD
92The altitude of place in which the motor is intended to work:- 672.80
93Humidity:- Wheather Generally remain humid during monsoon seasons
94Nature of atmosphere:- As normally encountered in shivalik ranges.
95Detail of quality of water :- Clear cold water
96Water free from sand or not:- Yes
97Water corosive or not:- Not
98Turbidity :- 50ppm
99Type of well:- Percolation
100Inside Dia of Well:- 6.00
101Depth of water during HFL in the pond:- 10.00
102Max. draw down:- (Metres) 3.00
103Depth of Percolation well:- (Metres) 5.00
104Any other information or requirement:- ----
105OPERATING CONDITIONS:-
106Type of current:- AC three/Single Phase
107Operating frequency:- 50 HZ
108Rated voltage:- 400 (+/-) 10 % Volts.
109System of earthing if any to to be adopted:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments.
110Speed of revolution:- To be quoted by tenderer.
111Direction of rotation:- To be quoted by tendrer.
112No. of working hours per day:- 20.00 Hours
113The max. Temp. of cooling air & water in the place in which the pumpset is intented to work in ordinary service:-
114MOTOR:- Generally warm
115Ref to BIS code:- BIS 9283-2013 read with BIS 14336-1998 or latest with upto date ammendments energy efficient motor of minimum effeciency level IE-2 as per IS 12615 2011.
116Type of enclosure of motor:- As per BIS 4691-1985 or latest with upto date ammendments
117Type of duty:- \\"S1\\" i.e Continuous duty type as per IS-12824-1989 or latest with upto date ammendments.
118Mechanical out put in KW:- Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20 % may be kept in the rated out put of prime mover.
119Class of insulation:- Class -B-
120Max.permissible temp. rise of motor reqd. if different from that given in B (viii) above:- To be quoted by tenderer
121Particulars of test reqd. & where they are to be conducted:-. As per terms & conditions attached.
122Particulars as to whether voltage limiting device will be employed:- Star Delta starter, oil immersed, fully automatic to be installed between bus bar & motor. Shunt capacitor is also proposed to be installed for improving the power factor at site.
123(NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW & above)
124Type of motor:- As per BIS 9283-2013 or latest with upto date ammendments.
125Details of shaft extension reqd:- To work with the pump offered.
126Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
127Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period:- To work the pump offered.
128Where possible fault capacity of the system to which the motor is connected:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
129PUMPS:-
130Nos of pumps reqd.:- 1 No Pump
131Spare parts required:- For two years normal maintenance as recommended by manufacturer.
132Type of drive:- Electric induction motor
133Optional fittings reqd.:-
134PUMP OPERATING CONDITIONS:-
135Capacity of each pump (in lps) :- 16.57
136Total head (in Mts.) :- 33.56
137If total head is not known then following details be provided:-
138i) Static head (in mtrs):-
139ii) Minimum depth of water (in mtrs) :-
140iii) Seasonal Variation in water level (in mtrs):-
141iv) Ground level to max. water level (in mtrs) :-
142v) Ground level to delivery point (in mtrs):-
143vi) Pressure in the suction tank (in kg/cm^2)-
144vii) Pressure in the delivery tank (in kg/cm^2) :-
145Length of R/Main (in mtrs):- 120
146Dia of R/Main (in mm):- 150
147Length of riser pipe (in mtrs):- 7
148Dia of riser pipe (in mtrs) 150
149Turbidity of water (in ppm):- 50 ppm
150Drive type:- Electric driver
151Limits of total head in which the pump is reqd. to operate:- (-)15% to (+) 10% of total head.
152Suction/delivery size of pump:- To be specified by the tenderer
153Efficiency of pump at To be specified by the tenderer
154a) duty head 33.56
155b) (+) 10 % head 36.92
156c) (-) 15 % head 28.53
157Material of construction:- To be specified by the tenderer (Manufactures certificate to be appended).
158Supplying and installation of suitable direct on line/ oil immersed star delta/ ATS/ stator rotor starter of standard make such as MEI /Kilburn/ Jyoti/ Siemens /Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
159Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
160Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting including providing and fixing in position the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
161a). Ammeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-(P-II)1983 latest with up to date ammendments.
162b). Voltmeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments.
163c). ICTP switches with HRC fuses of Kilburn / Larsen & Tubro/Standard/ Siemen/ Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
164d).Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
165e).ACB/ MCB/ Oil circuit breaker of suitable capacity of Kilburn/ L &T/ MEI/ GEC/ Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
166f).Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
167g) Earth leakage circuit breaker/ relay of recommended make such as Kilburn / L&T/ MET/ GEC conforming to IS-13118-1(1987) with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
168h).Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
169i).Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
170k).Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
171supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ Bir/ Kartar/ Pelicon make of cast iron double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 50(a) + surge pressure or 1.5 times the sustained operating pressure which ever is more conforming to BIS/API-standards with up to date ammendments for delivery line of pump. The class of valve shall be PN 1.6 conforming to IS 14846 -2000.
172Supply of Kirloskar/ Kilburn/ IVC/ Fouress/Gled/ BHEL/ Leader/ Bir/ Kartar/ Pelicon make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 50(a) + surge pressure or 1.5 times the sustained operating pressure which ever is more conforming to BIS/API-standards with up to date ammendments for delivery line of pump. The class of valve shall be PN 1.6 confirming to IS: 5312-Part-1.
173a).Providing,laying,jointing & testing at site suitable size copper PVC insulated armoured power three & half core cable ( from meter of HPSEB TO CIRCUIT BREAKER) conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/ EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder, nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. (30 Rmt.). The size of cable shall be 10 mm square
174b).Providing,laying,jointing & testing at site PVC jointless flat water proof cable ( for Motor Side ) as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. (2x125 = 250 Rmt.) The size of cable shall be 4 mm square
175Supplying and fixing of 100 mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
176Supply and errection of floor/wall mounted power factor shunt capactor confirming to BIS 2834-1986 latest with upto date ammendments BHEL/GES/Machneil/Mager/Bajaj make to raise the wevailing power fact or at ite to 0.95 for direct connection to induction motor individuly of required KVAR accourding to HP of motor offered incuding cable siemens/Gloster/zec make from busbar chamber to capacitor and also including LT/LK/Kilburn make TCTP switches confirming to BIS 4064-1978 or latest with HRC fuses (ranges to be specified by tenderer ) including cost of carrige of material in all leads and lifts and as per directed by the Engineer-In-Charge the capacitor shall be of 6 KVAR
177Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti / Kirloskar/ Beaconweir /BS & BE conforming to BIS 6595-2018 or latest with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear raw water having charters tics as mentioned in item 56.01 as under, with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof energy efficient three phase induction electric motor having minimum energy efficiency level IE-2 suitable for operation on the data given below. i/c the cost of all accessories in all lead & lifts & carriage of material at site as per direction of Engineer-In-Charge.
178Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 237.04 mtrs
179Capacity (in LPS) of each pump set. 16.57 Lps
180Dia of R/Main (in mm) 150.00 mm
181Length of R/Main. 1780.00 mtrs
182SITE CONDITIONS:-
183Location of Site:- GAMBHAR KHAD
184The altitude of place in which the motor is intended to work:- 676.50 Mtrs
185Humidity:- Wheather generally remains humid during monsoon season
186Nature of atmosphere:- As normally encountered in Shivalik Ranges
187Detail of quality of water :- Clear cold water
188Water free from sand or not:- Yes
189Water corosive or not:- Not
190Turbidity :- upto 50 PPM
191NPSH available :- Positive suction.
192Any other information or requirement:- ----
193OPERATING CONDITIONS:-
194Type of current:- AC three/Single phase
195Operating frequency:- 50 HZ
196Rated voltage:- 400 (+/-) 10 % Volts.
197System of earthing if any to to be adopted:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments.
198Speed of revolution:- To be quoted by tenderer
199Direction of rotation:- To be quoted by tenderer
200No. of working hours per day:- 20.00 Hours
201The max. Temp. of cooling air & water in the place in which the pumpset is intented to work in ordinary service:- 35 degree centigrade
202MOTOR:-
203Ref to BIS code:- BIS 12615-2011 read with BIS 900-1992 (latest) with upto date ammendments.
204Type of enclosure of motor:- SPDP (as per BIS 4691-1985 (Latest)
205Type of duty:- Continuous duty type as per IS-12824-1989 or latest with upto date ammendments.
206Mechanical out put in KW:- Suitable for driving centrifugal pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20 % may be kept in the rated out put of prime mover.
207Class of insulation:- Class - B-
208Max.permissible temp. rise of motor reqd. if different from that given in B (viii) above:- 35 degree centigrade
209Particulars of test reqd. & where they are to be conducted:-As per terms & conditions attached.
210Particulars as to whether voltage limiting device will be employed:- ATS/star delta starter, oil immersed, fully automatic to be installed between bus bar a& motor shunt capacitor is also proposed to be installed for improving the power factor at site.
211(NOTE:- Star delta starter upto 37.5 KW, ATS between 37.5 KW to 50 KW & Stator rotor starter beyond 50 KW)
212Motor whether squirrel cage or slipring:- (Note:- Squirrel cage upto 65HP and slipring above 65HP) Squirrel cage/slip-ring
213Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
214Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continouslly rated for Squirrel cage/Slipring motor
215Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 time of the full load current.
216Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period:- Sufficient to work the pump offered.
217Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 time the rated current for two minutes without suffering damages or permanent deformations.
218PUMPS:-
219Nos of pumps reqd.:- 1 No Pump
220Spare parts required:- For two years normal maintenance as recommended by manufacturer.
221Optional fittings reqd.:- Air cock for exahausting air from each stage.
222PUMP OPERATING CONDITIONS:-
223Capacity of each pump (in lps) :- 16.57
224Total head (in Mts.) :- 237.04
225If total head is not known then following details be provided:-
226i) Static head (in mtrs):-
227ii) Minimum depth of water (in mtrs) :-
228iii) Seasonal Variation in water level (in mtrs):-
229iv) Ground level to max. water level (in mtrs) :-
230v) Ground level to delivery point (in mtrs):-
231vi) Pressure in the suction tank (in kg/cm^2)-
232vii) Pressure in the delivery tank (in kg/cm^2) :-
233Length of R/Main (in mtrs):- 1780
234Dia of R/Main (in mm):- 150
235Drive arrangement:- Direct through flexible coupling on a common base plate.
236Drive type:- electric driven
237NPSH reqd.:- To be qoted by the tenderer
238Limits of total head in which the pump is reqd. to operate:- (-)15 % to (+) 10% of total head.
239Suction/delivery size of pump:- To be specified by the tenderer
240Efficiency of pump at To be specified by the tenderer
241a) duty head 237.04 mtrs
242b) (+) 10 % head 260.74 mtrs
243c) (-) 15 % head 201.48 mtrs
244Material of construction:- To be specified by the tenderer (manufacturers certificate to be appended)
245Supplying and installation of suitable direct on line/ oil immersed star delta/ ATS/ stator rotor starter of standard make such as MEI /Kilburn/ Jyoti/ Siemens /Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
246Note:- Star - delta - starter upto 37.5 KW , ATS between 37.5 KW to 50 KW and stater rotor starter with slipring motor beyond 50 KW.
247Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting including providing and fixing in position the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
248a). Ammeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 1248-(P-II)1983 latest with up to date ammendments.
249b). Voltmeter AC supply,100 mm dia circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selector switches conforming to BIS 4064-1978 with up to date ammendments.
250c). ICTP switches with HRC fuses of Kilburn/Larsen & Tubro/Standard/Siemen/Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
251d).Busbar chamber having three copper bars of suitable rating for full length equal to width of board of three live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
252e).ACB/ MCB/ Oil circuit breaker of suitable capacity of Kilburn/ L &T/ MEI/ GEC/ Standard make on incomming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with initial oil filling whenever required & neutral linked under voltage release.
253f).Three phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
254g) Earth leakage circuit breaker/ relay of recommended make such as Kilburn / L&T/ MET/ GEC conforming to IS-10118-461989 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side.
255h).Hour run meter of reputed make of four digit capacity conforming to BIS-722 (latest edition)/recommendations.
256i).Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
257k).Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
258Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled/ BHEL/ Leader/ Bir/ Kartar/ Pelicon make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) + surge pressure or 1.5 times sustained operating pressure whichever is more conforming to API-standards with up to date ammendments for delivery line of pump. The class of valve shall be ASA-300 conforming to API-600 specifications
259Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar /Pelicon make of suitable size cast steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 56.01 + surge pressureor 1.5 times sustained operating pressure whichever is more conforming to API-standards with up to date ammendments for delivery line of pump. The class of valve shall be ASA-300 conforming to API-6D specifications
260Supply of Kirloskar/ Kilburn/IVC/ Fouress/ Gled/ BHEL/ Leader Bir/ Kartar/ Pelicon make of suitable size cast iron /Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure as per item No.5601+ surge pressure or 1.5 times sustained operating pressure whichever is more conforming to API-standards with up to date ammendments for delivery line of pump. The class of valve shall be ASA-300 conforming to API-6D specifications
261Providing, laying,jointing & testing at site suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads & lifts & as directed by the Engineer-in-charge. The size of cable shall be 120 mm square.
262Providing, laying, jointing & testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads & lifts & as directed by the Engineer-in-charge. The size of cable shall be 70 mm square.
263Providing & laying at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c cost of carriage of material in all leads & lifts & as directed by the Engineer-in-charge.
264Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/ Gloster/ ICC make from busbar chamber to capacitor & also including L&T// Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads & lifts & as directed by the Engineer-in-charge.i/c cost of carriage of material in all leads & lifts & as directed by the Engineer-in-charge. The capacity of shunt capactor is 25 KVAR.
265Supply of 100 mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
266NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
267Wiring for light/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm PVC insulated heat resitant flame retardent (HRFR)of low smoke single core (flexible) copper conductor cable in PVC casing and capping and earthing the light point with 1.5 sq.mm HRFRLS /PVC insulated single Group \\"C\\" as required required including carriage of all material within all leads and lifts.
268Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible ) copper conductor cable in PVC casing and caping along with 1 no, 4sq. mmHRFRLS/PVC insulated single core copper as required including carriage of materials within all leads and lifts.
269Wiring for light/power plug with 4 x 4 Sq.mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible ) copper conductor cable in PVC casing and capping along with 2no, 4sq. mmHRFRLS/PVC insulated single core copper as required including carriage of materials within all leads and lifts.
270Wiring for light/power plug with 2 x 1.5 Sq.mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible ) copper conductor cable in PVC casing and capping along with 1 no, 4sq. mmHRFRLS/PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts.
271Wiring for circuit / sub main wiring with 4 x 1.5 Sq.mm PVC insulated heat resistant flame retardent (HRFR)and low smoke single core (flexible ) copper conductor cable in PVC Casing & capping along with 2 no, 2.5sq. mm(4x2.5+2x2.5) HRFRLS/PVC insulated single core copper conductor cable as required including carriage of materials within all leads and lifts.
272Supplying and fixing metal box of 100 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phonolic leminated sheet cover fixing 3 pin 15/16 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts
273S/F of 6amps to 32 amps rating 10 KA breaking capacity ,240 Volts, \\"C\\" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required including carriage of materials within all leads and lifts Category -A single pole.
274Supplying and fixing 40 Amps/50 amps / 63 Amps rating 10 KA breaking capacity 240 Volts \\"C\\"curves miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts.Double pole Category- B 63 Amps.
275Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts,on surface/recessed complete with tinned, copper busher neutral link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing etc. as required : bus bar 8 way.
276Providing, installing, testing and commissioning of 2x36 watt -CFL surface mounting (categary \\"A\\" including wiring with 1.5 Sq mm PVC insulated copper conductor single core cable etc.as required .
277Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length(upto 30 cm) with 1.5 Sqmm PVC insulated copper conductor single core cable etc.as required 1200 mm sweep Category A.
278Providing, installing, testing and commissioning of 1x36 watt -FTL (T8) shock proof slim (categary \\"A\\" including wiring with 1.5 Sq mm PVC insulated copper conductor single core cable etc.as required . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56370138
AUTHORITY Government Departments
TENDER VALUE 1.02 Crore
LAST DATE 20-07-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for Providing Lis To Village Khateta, Johri In Gp Maan In Tehsil Arki District Solan Hp (Sub Head:- Construction Of Pump House I/C Electrical Works, Construction Of Sumpwell 50000 Litrs Capacity, Main Storage Tank / Mdt 50000 Liters Capacity , Intake Well, Laying, Jointing, Testing Of Gms Pipe In Rising Main Conforming To Is (1239-Part-I) Of 150 Mm Dia, Laying, Jointing And Testing Of Gms Pipe Conforming To Is-1239 (Part-1) Of Dia 125Mm (Mg) And Laying, Jointing And Testing Of Hdpe Pipe Conforming To Is 4984-2016 In Distribution System Construction Of Field Out Let, Assemblies Supply, Erection And Testing Of Submersible And Centrifugal Pumping Machinery Along With Allied Accessories And Construction Of Retaining Wall And Boundary Wall Around The Pump House).
Basic Detail
Tender No 5439-79 dated 08-07-2026
Bidding Type Tender
Location
City Solan
State Himachal Pradesh
Key Dates
Publish Date 08 Jul 2026
Submission Date 20 Jul 2026
Open Date 20 Jul 2026
Finance
Tender Value 1.02 Crore
Tender Fee 5000
EMD 1.77 Lakhs
Exemption Not Available
Document List
BOQ_205198.xls
da1eac04-6409-4b8f-8090-e904214806b2.html
Form6.pdf
Form8.pdf
TC.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_205198.xls

html

da1eac04-6409-4b8f-8090-e904214806b2.html

pdf

Form6.pdf

pdf

Form8.pdf

pdf

TC.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail