Housing Urban and Rular Development Government Departments Closing in 2 days TDR #56370003

Tender For Renovation Work (Civil Construction Along With Related Electrical Installations) At Jadavpur University Main Hostel Block A & D --- Balance electrical installation Works --Different Blocks.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Jul 2026
2 days left
EMD
60952
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Work (Civil Construction Along With Related Electrical Installations) At Jadavpur University Main Hostel Block A & D --- Balance electrical installation Works --Different Blocks.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Jul-2026 1st Corrigendum Notice in respect of change in BOQ BOQ 24-Jul-2026

BOQ

Name of Work:- Renovation work (Civil construction along with related electrical installations) at Jadavpur University Main Hostel Block A & D --- balance EI works --Different Blocks.
Sl. No. Item Description
1Dismantling the existing defective main switch, BDB's and damaged wirings, fan, light fittings,computer board etc. including handed over the same to the authority without disturbing the day to day Govt works as well as providing uninterrupted power supply by temporary arrangement.
2Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per following rating (Make: Siemens/ L&T or as approved by E.I.C)
3Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4a) 4 way (4 + 12), Double door [Make: Legrand /Siemens/L&T or as approved by E.I.C]
5Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
6a) 4 way (4 + 12), Double door [Make: Legrand /Siemens/L&T or as approved by E.I.C]
7Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8a) 16 way, Double door [Make: Legrand /Siemens/L&T or as approved by E.I.C]
9Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
10125 A,36KA,FPMCCB [Make: Legrand /Siemens/L&T or as approved by E.I.C]
11Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12(a) 63 A [Make: Legrand /Siemens/L&T or as approved by E.I.C]
13Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1463A [Make: Legrand /Siemens/L&T or as approved by E.I.C]
15Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
16a) Single pole [Make: Legrand /Siemens/L&T or as approved by E.I.C]
17b) 63 Amps TP MCB [Make: Legrand /Siemens/L&T or as approved by E.I.C]
18Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable (Finolex/RR Kabel / Havells/ Polycab/Gloster or as approved by E.I.C) in surface/ recessed medium class PVC conduit (Precision make or as approved by E.I.C), with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
19Group B
20Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable (Finolex/RR Kabel / Havells/ Polycab/Gloster or as approved by E.I.C) in surface/ recessed medium class PVC conduit (Precision make or as approved by E.I.C) as required.
21a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
22b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
23c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
24Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
25a) 2.5 sq mm
26b) 4 sqmm
27c) 6 sq mm
28Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C]
294 Core 50 Sqmm
304 Core 25 Sqmm
31Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
32Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
33Upto 35 sq. mm (clamped with 1mm thick saddle)
34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
354 X 50 sq. mm (35mm)
364 X 25 sq. mm (28mm)
37Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
38Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
39Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
40Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt (Make: Signify / LT / Wipro or as approved by E.I.C)
41Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification
42Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
43Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm) Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 140 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient or as approved by E.I.C)
44Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
45Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite /perspex top cover incl. making necy. connections etc.
46Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9mm MS sheet flat suitable for beam having flange upto 150 mm wide–(As per Drawing no. 476 of PWD Specification Book – May 1991)
47Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.
48Supply & delivery of 230 V, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 920 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient or as approved by E.I.C)
49Supply & delivery of 230 V, 50 Hz, single phase, 132 watts, 18\\" (450 mm) Sweep, speed 900 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 3965 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. (Make:- Crompton Greaves/EPC/Orient or as approved by E.I.C)
50Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, ommissioning etc. as required.
51Upto 450 mm sweep
52Supply, fabrication and fixing of iron structure for fixing exhaust fan by 25 mm x 6 mm flat iron and painting the same as per direction of EIC
53Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
54a) 200 mm X 250 mm X 60 mm deep
55Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required
56a) 240 mm x 200 mm x 65 mm
57Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
58a) 200 mm x 150 mm x 65 mm
59Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws
60a) 200 mm x 150 mm x 65 mm
61Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
62Earthing with G.I. earth pipe 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. By ISI-Medium GI pipe
63Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56370003
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 24-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Work (Civil Construction Along With Related Electrical Installations) At Jadavpur University Main Hostel Block A & D --- Balance electrical installation Works --Different Blocks.
Basic Detail
Tender No WBPWD/EE-ECD/e-NIQ-35/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 13 Jul 2026
Submission Date 24 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 60952
Exemption Not Available
Document List
ae18f6f9-ad4d-4531-909e-603e72bdc395.html
BOQ_5086137.xls
Tendernotice_1 (15).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

ae18f6f9-ad4d-4531-909e-603e72bdc395.html

xls

BOQ_5086137.xls

pdf

Tendernotice_1 (15).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender