Tender For Installation Of Solar Submerssible With Water Purifier At Different Place Gp Under Purbasthali-Ii Block Out Of 15Th Fc Fund 2025-26
Tender Overview
Project Description
Tender for Installation Of Solar Submerssible With Water Purifier At Different Place Gp Under Purbasthali-Ii Block Out Of 15Th Fc Fund 2025-26 , Labour For Boring Tube Well Of Required Dia. By Water Jet System Through Any Type Of Soil Strata Including Hire And Labour Charges For Boring Pipes, Scaffolding, Tools And Plants As Necessary And Taking Out Them And Lowering Pipes, Strainers, Blind Pipe Etc. And Fitting And Fixing The Same Complete Including Bucket Washing And Other Incidental Works In The Connection. The Tube Well Should Have A Minimum 50 Mm Gap In Between The Outside Of The Tubewell Pipe And The Bore. (D) For Depth Upto 150 Metre For 50 Mm Dia. Tube Well With Top Enlargement Of 100 Mm Dia. (Iii) 40 Mm Dia. Boring Etc. , (Ii) 100 Mm Dia. Boring Etc. Top Enlargement , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) (I) 40 Mm Dia. (Patton/Polo/Utkarsh/Swastick) , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) (Ii) 100 Mm Dia. (Patton/Polo/Utkarsh/Swastick/Bansal) , Supplying Pvc Strainer Of Approved Make With Adapter Conforming To I.S.12818 Specifications. (I) 40 Mm Dia. , Supplying, Fitting And Fixing Steel Cutter Piece Upto 450 Mm Long With Sockets. (I) 40 Mm Dia , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (L) Reducing Socket (Mm X Mm) 100 X 40 , Supply Of G.I. Short Piece Of Tata Make (Above 50Mm & Upto150 Mm Long) (Ix) 100 Mm , Packing The Annular Space Between The Outside Of The Tube Well Pipes & Strainers And The Bore With Pea Size Washed Gravel Of Approved Quality Having Size From 2 Mm To 5 Mm Or The Size Approved By The Engineer-Incharge Including Cost Of All Materials Labour And Equipment Complete. , Supplying, Fitting And Fixing 300 Mm M.S. Housing Clamp Of Approved Quality. , Solar Module: Supply , Transport , Installation And Commissioning Of Isi Marked Solar Modules As Per Following Specification: 1. Cell: Indigenous Mono Crystalline Silicon Spv Cells 2. Solar Module: Monocrystalline Cell With Perc Technology / Module With Bifacial Cell. 3. Standards: Isi Marked As Per Is 14286 And Having Certification Of Iec 61853(1), 61730(1&2), 61710 4.Modules Must Qualify To Is 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill Factor: More Than 75% . 7. Module Wattage Mismatch In The Spv Array: Within ±3% 8. Wattage Output Warranty:Should Not Be Less Than 90% At The End Of 10 Years And 80% At The End Of 25 Years. 9.The Power Output Of Individual Pv Modules Used In The Pv Array, Under Stc: Minimum 300 Wp. Necessary Test Certificates Also To Be Supplied. For Detail Information Please See Cl. No. 2.1 Of Technical Specification . A) For 1 Hp Off-Grid Solar Water Pumping System With Monocrystalline/ Monocrystalline Perc/Bifacial Spv Modules - 900 - 1200 Wp. (Solar Submerssible Pump) , Power Conditioning Unit With Enclosure :Supply , Transport , Installation And Commissioning Of Solar Power Conditioningunit Consisting Of Following Components And Features: 1) Variable Frequency Drive With Inbuilt Mppt, Voltage Rangesuitable For Operating Pump-Motor Set Of 1Hp To 20 Hp, Detail Mentioned In Cl.6.12) Power Input : Dc Source For 1Hp, 2Hp And 3Hp.3) Power Input : Ac / Dc Source Or Hybrid For 5Hp And Above.4) Incomer: Dc Mcb 2 Pole 16 annual periodical maintenance Upto 5 Hp, 25 annual periodical maintenance For 7.5Hp And 10 Hp, 40 Ampfor 15 To 20 Hp As Per Is/Iec 60947-25) Incomer: Ac Mcb 4 Pole 16 annual periodical maintenance For 5.0 Hp, 25 annual periodical maintenance For 7.5Hp And 10 Hp, 40 Ampfor 15 To 20 Hp As Per Is/Iec 60947-2 6) Type Ii Dc Spd Of 40 Ka. 7) Type Ii Ac Spd Of 40 Ka For Ac/ Dc Or Hybrid Input. 8) Dual Input (Solar/Grid) 25 annual periodical maintenance Changeover Switch For 5Hp And 7.5 Hp, 40 Ampfor 10 Hp, 63 annual periodical maintenance For 15 To 20 Hp 9) Reverse Protection Diode 1600 Vdc With Heat Sink.10) Data Logger.11) Remote Monitoring System.12) Should Have Built -In Emc Filters .13)Ip 65 Glands For Cable In And Out. 14) Min. Ip 54 Enclosure.For Detail Features, Protections, Rms, Communication Architecture, Security, Data Storage, Tolerance Of Various Parameters, Standards To Be Qualified, Etc. Please Refer To Cl. 6.1 Of Technical Qualification. Note: Ac Spd, Ac Mcb And Selector Switch To Be Provided Only For Item No. 3(F) To 3(L). A) For 1 Hp Capacity Pump-Motor Set With Ac / Dc Or Hybrid Input (For Solar Submerssible) , Cable And Accessories :Supplying, Fitting And Fixings Of Uv Rated Copper Cable Laid Inside Hdpe Conduit Andother Accessories As Per Followings With Necessary Connection With The Solar Pvmodule, Mppt Etc.I. 4.0 Sq Mm Single Core Multi Studs - 5M(For 1Hp/2Hp/3Hp) & 20M(For5/7.5/10/15/17.5/20 Hp)Ii. Lugs, Hdpe Pipe, Flexible Pipe, Saddle, Cable Tie Etc A) For 1 Hp/2 Hp/3Hp Per Structure (For Solar Submerssible) , Earthing: Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below: By Isi-Medium Gi Pipe Including Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming And Connecting To Individual Structure To Earth Electrode Including S&F 20 Mm X 3 Mm Galvanised (Hot Dip) Ms Flat On Wall/Floor With Gi Saddles As Required And Connection To Equipments Incl. Drilling Holes, With Bolts, Nuts, Washers Etc. , M.S. Structural Works In Columns, Beams Etc. With Simple Rolled Structural Members .......................Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. I) For Structural Members Of Specified Sections Weighing Less Than 22.5 Kg./M (For Solar Submerssible) , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) 32 Mm (Patton/Polo/Utkarsh/Swastick) , Supply And INSTALLATION Of 80 Mm Bore Well 1 Hp Submesible Pump (Kirloskar/ Crompton/ C.G/ K.S.B./Cri Or Other Approved Brand As Per Direction Of Eic ( Ac/ Dc Supply 80 To 110 Volt Outlet 32 Mm ) , Supply And INSTALLATION Of 80 Mm Bore Well 1 Hp Submesible Pump (Kirloskar/ Crompton/ C.G/ K.S.B./Cri Or Other Approved Brand As Per Direction Of Eic ( Ac/ Dc Supply 80 To 110 Volt Outlet 32 Mm ) 32 Mm , Power Conditioning Unit (Pcu) Supply & Installtion Of Offgrid Hybrid Pcu, 1 Kv, 24V System, Main Features - Pcu Should Be A Combined Unit Comprising Of Inverter, Charge Controller, Visual Display And Necessary Protection. It Should Be Industrial Grade Bi-Directional Inverter It Should Have Integrated Mppt Charge Controller It Should Be Rated For Continuous Operation At Full Load It Should Have Programmable Battery Management Parameters It Should Have Solar Priority Grid Charging & Load. It Should Automatic Restart After Over Load Triggered Shutdown. It Should Have Continuous Battery Life And State Of Health Monitoring. Pcu Should Have Provision For Pcu By-Pass Arrangement So As To Cater Load Directly Through Grid, In Case Of Pcu Failure Major Specification Are As Follows: Rating Of Pcu-1 Kva 230 V Ac Sine Wave Inbuilt Mppt Charge Controller Suitable To Charge (2 Nos 12V 100 Ah Battery Bank, Control Type-Voltage Source, Microprocessor Assisted, Output Regulation. Power Control Mppt, Output Voltage - 1 Phase, 230V Ac, Adjustable Up To 250V (+12.5%, -20% V Ac) Frequency-50 Hz, +-0.5 Hz, Dc Link Voltage Range, Operting Temperature Range 0 C To 55 C. Housing Cabinet - Pcu To Be Housed In Suitable Switch Cabinet With Protection Class - Ip20. Over Load Capacity 200 % Of Continuous Rating For 10 Sec. Over Load Protection - Auto Reset Protections: Grid Over/Under Voltage, Grid Over/Under Frequency, Inverter Over Load, Unbalance Output Load, Short Circuit (Line-To-Line & Line-To-Ground), Battery Low/High Shutdown. Solar/Battery Reverse, Surge Protection At Ac And Dc Both Side Front Panel Displaying : Battery Voltage & Current Spv Voltage, Current, Instantaneous Power (Kw), Instantaneous Energy (Kwh), Inverter Output Voltage, Current Nad Power (Kva), Grid Voltage, Current, Battery Charging And Discharging Status And Charge Level Indicator Front Panel Led Indicators : System On, Inverter On, Spv Charging, Mains Charging, Battery Low, System Fault Dielectric Strength : 1.1 Kv Between Input/Output With Ground With Emi Protection & 1.5 Kv Between Input And Output Standerd & Make : As Per Mnre Guidelines And Conforms To Iec 61683 And Iec 60068 , Battery Bank Supply Of 12V Tubular Solar Lead Acid Type Battery Bank Having A Storage Capacity Of C10, 100 Ah The Battery Bank Should Be Compromised Of 2 Nos Of 12 V, 100 Ah Each, Tubular Lead Acid Type Battery Having Long Service Life (Minimum 5 Years), The Details Specification Are As Flow : Terminal Of Cell: Insulated Cover, Saftey Vent: Fitted With Explosion Proof Safety Vents Plug. Self Discharge Rate:5% Per Month At 20 C And 8% Per Month At 30 C Charge Efficiency More Than 90% Up To 70% State Of Charge. Container: Polypropylene/Hard Rubber With Carrying Handle. Cover Protective Cover Of Polypropylene/Hard Rubber. Max Depth Of Discharge 80% (@C/10 Standared & Make As Per Bis Standerds . Exide/Luminous/Utl) , Distn. Wiring In 22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire (Brand Approved By Eic) In 19 Mm Bore, 3 Mm Thick Polythen Pipe Complete With All Accessories Embedded In Wall To 240 V 6A 5 Pin Plug Point Incl. S&F 240 V 6A 3 Pin Modular Type Plug Socket & Modular Type Switch (Brand Approved By Eic) Incl. S&F Earth Continuity Wire, Fixed On 4 Module Gi Switch Board With 3/4 Module Top Cover Plate Flushed In Wall Incl. Mending Good Damages To Original Finish Ref.:- Pwd (Wb) Schedule Of Rates 2017 For Electrical Works, P/E-20, Item No. - 3(I),(Iii); (I) On Board , (Iii) Average Run 3 Mtr , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection,6-32 A ,Sp (Make Legrand/L&T/Havells ) , Extra For Supplying Additional Wire For Down Rod & Painting The Rod Exceeding 30 Cm By 2X1.5 Sqmm Flexible Copper Wire Ref.:- Pwd (Wb) Schedule Of Rates 2017 For Electrical Works, P/C-3, Item No. - 21(B); , Supply And Delivery Of Ceilling Fan 48 Sweep Orient Make (Urban Development And Municipal Affairs Department Schedule Of Rates For Electrical-Mechanical Works 2018; Page No. - 23; Item No - 70B) , Fixing Only Ceiling Fan Complete With Blades, Canopy, Fork, Rubber Bush Etc. Incl. S&F Connecting Wire For Down Rod Upto 30 Cm Incl. Painting The Rod With Approved Paint And Making Necessary Connection As Required By 2X1.5 Sqmm Flexible Copper Wire Ref.:- Pwd (Wb) Schedule Of Rates 2017 For Electrical Works, P/C-3, Item No. - 21(A); , Supply & Fixing 240V, Modular Socket (2 Module) Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. , Supplying And Fixing Of 20W Led Bulb On Wall With All Necessary Accessories (Phillips/Havells/Crompton Greves) Ref.:- Market Rate , Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming. For Soft Soil , Supplying Fitting Fixing Of 36 Watt 220-240 Volt Led Tube Light Approved By Eic. (Philips,Bajaj) Ref.:- Market Rate , Supplying Fitting Fixing Of 300 Mm Exhaust Fan (Crompton) Ref.:- Market Rate , Supplying And Fixing Sheet Steel Main Switches On Flat Iron Frame On Wall 240V Dp With Fuse On L&N 15/16 A Havells , Collecting Sample Of Water For Bacteriological And Chemical Test From Any Depth At Any Time During Execution Of Work Including Hire And Labour Charges For Tools And Plants And Sterilising The Equipments, Paying All Charges And Fees, Testing Etc. Complete In All Respect As Per Direction. , Supplying P.V.C. Water Storage Tank Of Approved Quality With Closed Top With Lid (Black) - Multilayer (B) 1000 Litre Capacity , Labour For Hoisting Plastic Water Storage Tank. (I) Upto 1500 Litre Capacity. (A) Upto 2Nd Story From G.L. , Kent And/Or Approved Make Water Purifiers 8L Capacity With 60L/Hr Output Fully Automatic , Display Board , Cess
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Jul-2026 | DATE CHANGE | Date | 15-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (iii) 40 mm dia. boring etc. |
| 2 | (ii) 100 mm dia. boring etc. top enlargement |
| 3 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) (i) 40 mm dia. (Patton/Polo/Utkarsh/Swastick) |
| 4 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) (ii) 100 mm dia. (Patton/Polo/Utkarsh/Swastick/Bansal) |
| 5 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 40 mm dia. |
| 6 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (i) 40 mm dia |
| 7 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (L) Reducing Socket (mm X mm) 100 X 40 |
| 8 | Supply of G.I. short piece of TATA make (Above 50mm & upto150 mm long) (ix) 100 mm |
| 9 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. |
| 10 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 11 | Solar Module: Supply , transport , installation and commissioning of ISI marked Solar Modules as per following specification: 1. Cell: Indigenous mono crystalline silicon SPV cells 2. Solar Module: Monocrystalline cell with PERC technology / module with bifacial cell. 3. Standards: ISI marked as per IS 14286 and having certification of IEC 61853(1), 61730(1&2), 61710 4.Modules must qualify to IS 170210 (Part 1) 5.Min. Efficiency: 19.5%. 6. Fill factor: More than 75% . 7. Module wattage mismatch in the SPV array: within ±3% 8. Wattage output warranty:Should not be less than 90% at the end of 10 years and 80% at the end of 25 years. 9.The power output of individual PV modules used in the PV array, under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For detail information please see Cl. no. 2.1 of technical specification . a) For 1 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 900 - 1200 Wp. (Solar Submerssible pump) |
| 12 | Power conditioning unit with enclosure :Supply , transport , installation and commissioning of Solar Power conditioningUnit consisting of following components and features: 1) Variable frequency Drive with inbuilt MPPT, voltage rangesuitable for operating pump-motor set of 1HP to 20 HP, detail mentioned in Cl.6.12) Power input : DC source for 1HP, 2HP and 3HP.3) Power input : AC / DC source or hybrid for 5HP and above.4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5HP and 10 HP, 40 ampfor 15 to 20 HP as per IS/IEC 60947-25) Incomer: AC MCB 4 pole 16 amp for 5.0 HP, 25 amp for 7.5HP and 10 HP, 40 ampfor 15 to 20 HP as per IS/IEC 60947-2 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5HP and 7.5 HP, 40 ampfor 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heat sink.10) Data Logger.11) Remote monitoring system.12) Should have built –in EMC filters .13)IP 65 glands for cable in and out.14) Min. IP 54 enclosure.For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(l). a) For 1 HP capacity Pump-motor set with AC / DC or hybrid input (For Solar Submerssible) |
| 13 | Cable and Accessories :Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit andother accessories as per followings with necessary connection with the Solar PVModule, MPPT etc.i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3HP) & 20m(for5/7.5/10/15/17.5/20 HP)ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc a) For 1 HP/2 HP/3HP per structure (For Solar Submerssible) |
| 14 | Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 15 | M.S. structural works in columns, beams etc. with simple rolled structural members …………………..including all incidental chagessuch as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m (For Solar Submerssible) |
| 16 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes(Dia) 32 mm (Patton/Polo/Utkarsh/Swastick) |
| 17 | Supply and instalation of 80 mm bore well 1 HP Submesible pump (Kirloskar/ Crompton/ C.G/ K.S.B./CRI or other approved brand as per direction of EIC ( AC/ DC supply 80 to 110 Volt outlet 32 mm ) |
| 18 | Supply and instalation of 80 mm bore well 1 HP Submesible pump (Kirloskar/ Crompton/ C.G/ K.S.B./CRI or other approved brand as per direction of EIC ( AC/ DC supply 80 to 110 Volt outlet 32 mm ) 32 mm |
| 19 | Power Conditioning Unit (PCU) Supply & installtion of Offgrid Hybrid PCU, 1 KV, 24V System, Main Features - PCU should be a combined unit comprising of inverter, charge controller, visual display and necessary protection. It should be industrial grade bi-directional InverterIt should have Integrated MPPT Charge ControllerIt should be rated for Continuous operation at full loadIt should have Programmable battery management parametersIt should have solar priority grid charging & Load. It should Automatic restart after over load triggered shutdown. It should have Continuous battery life and state of health monitoring. PCU should have provision for PCU by-pass arrangement so as to cater load directly through grid, In case of PCU failureMajor Specification are as follows: Rating of PCU-1 KVA 230 V AC sine wave inbuilt MPPT Charge Controller Suitable to charge (2 nos 12V 100 AH Battery Bank, Control Type-Voltage Source, Microprocessor assisted, Output regulation. Power Control MPPT, Output Voltage - 1 Phase, 230V AC, adjustable up to 250V (+12.5%, -20% V AC) Frequency-50 Hz, +-0.5 HZ, DC link Voltage range, Operting Temperature Range 0 C to 55 C. Housing Cabinet - PCU to be housed in suitable switch cabinet with protection Class - IP20. Over load capacity 200 % of continuous rating for 10 Sec. Over load Protection - Auto ResetProtections: Grid over/Under voltage, Grid Over/Under frequency, Inverter Over load, Unbalance Output load, Short Circuit (line-to-line & line-to-ground), Battery Low/High Shutdown. Solar/Battery Reverse, Surge Protection at AC and DC both sideFront Panel Displaying : Battery Voltage & Current SPV Voltage, Current, Instantaneous Power (KW), Instantaneous Energy (kWh), Inverter Output Voltage, Current nad Power (kVA), Grid Voltage, Current, Battery Charging and Discharging status and Charge level IndicatorFront Panel LED Indicators : System On, Inverter On, SPV Charging, Mains Charging, Battery Low, System FaultDielectric Strength : 1.1 kV between input/output with ground with EMI protection & 1.5 kV between input and outputStanderd & Make : As per MNRE Guidelines and conforms to IEC 61683 and IEC 60068 |
| 20 | Battery Bank Supply of 12V Tubular Solar Lead Acid type Battery Bank having a storage capacity of C10, 100 AH The battery bank should be compromised of 2 nos of 12 V, 100 Ah each, Tubular lead Acid type battery having long service life (minimum 5 Years), The details specification are as flow : Terminal of Cell: Insulated Cover, Saftey Vent: Fitted with explosion proof safety vents plug. Self discharge rate:<5% per month at 20 C and <8% per month at 30 C Charge efficiency more than 90% up to 70% state of charge. Container: Polypropylene/Hard Rubber with carrying handle. Cover protective cover of polypropylene/hard rubber. Max Depth of Discharge 80% (@c/10 Standared & Make As per BIS Standerds . Exide/Luminous/UTL) |
| 21 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish Ref.:- PWD (WB) Schedule of Rates 2017 for Electrical Works, P/E-20, Item No. - 3(i),(iii); (i) On Board |
| 22 | (iii) Average run 3 mtr |
| 23 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection,6-32 A ,SP (Make Legrand/L&T/Havells ) |
| 24 | Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wireRef.:- PWD (WB) Schedule of Rates 2017 for Electrical Works, P/C-3, Item No. - 21(b); |
| 25 | Supply and delivery of Ceilling fan 48” Sweep Orient Make (Urban Development and Municipal Affairs Department Schedule of Rates for Electrical-Mechanical Works 2018; Page No. - 23; Item No - 70b) |
| 26 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire Ref.:- PWD (WB) Schedule of Rates 2017 for Electrical Works, P/C-3, Item No. - 21(a); |
| 27 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 28 | Supplying and fixing of 20W LED bulb on wall with all necessary accessories (Phillips/Havells/Crompton Greves) Ref.:- Market Rate |
| 29 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil |
| 30 | Supplying fitting fixing of 36 watt 220-240 volt LED Tube Light approved by EIC. (Philips,Bajaj) Ref.:- Market Rate |
| 31 | Supplying fitting fixing of 300 mm Exhaust Fan (Crompton) Ref.:- Market Rate |
| 32 | Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V DP with fuse on L&N 15/16 A Havells |
| 33 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 34 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity |
| 35 | Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 2nd story from G.L. |
| 36 | Kent and/or approved make water purifiers 8L capacity with 60L/hr output fully automatic |
| 37 | Display Board |
| 38 | Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender