Tender For Installation Of Water Purifier With Submerssible Pump At Different Place Under Purbasthali-Ii Block Out Of 15Th Fc Fund 2025-26
Tender Overview
Project Description
Tender for Installation Of Water Purifier With Submerssible Pump At Different Place Under Purbasthali-Ii Block Out Of 15Th Fc Fund 2025-26 , Labour For Boring Tube Well Of Required Dia. By Water Jet System Through Any Type Of Soil Strata Including Hire And Labour Charges For Boring Pipes, Scaffolding, Tools And Plants As Necessary And Taking Out Them And Lowering Pipes, Strainers, Blind Pipe Etc. And Fitting And Fixing The Same Complete Including Bucket Washing And Other Incidental Works In The Connection. The Tube Well Should Have A Minimum 50 Mm Gap In Between The Outside Of The Tubewell Pipe And The Bore. (D) For Depth Upto 150 Metre For 50 Mm Dia. Tube Well With Top Enlargement Of 100 Mm Dia. (Iii) 40 Mm Dia. Boring Etc. , (Ii) 100 Mm Dia. Boring Etc. Top Enlargement , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) (I) 40 Mm Dia. (Patton/Polo/Utkarsh/Swastick) , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) (Ii) 100 Mm Dia. (Patton/Polo/Utkarsh/Swastick/Bansal) , Supplying Pvc Strainer Of Approved Make With Adapter Conforming To I.S.12818 Specifications. (I) 40 Mm Dia. , Supplying, Fitting And Fixing Steel Cutter Piece Upto 450 Mm Long With Sockets. (I) 40 Mm Dia , Supply Of Pvc Pipes & Fittings Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (L) Reducing Socket (Mm X Mm) 100 X 40 , Supply Of G.I. Short Piece Of Tata Make (Above 50Mm & Upto150 Mm Long) (Ix) 100 Mm , Packing The Annular Space Between The Outside Of The Tube Well Pipes & Strainers And The Bore With Pea Size Washed Gravel Of Approved Quality Having Size From 2 Mm To 5 Mm Or The Size Approved By The Engineer-Incharge Including Cost Of All Materials Labour And Equipment Complete. , Supplying, Fitting And Fixing 300 Mm M.S. Housing Clamp Of Approved Quality. , A) For 1 Hp Capacity Pump-Motor Set With Ac / Dc Or Hybrid Input (For Solar Submerssible) , Cable And Accessories :Supplying, Fitting And Fixings Of Uv Rated Copper Cable Laid Inside Hdpe Conduit Andother Accessories As Per Followings With Necessary Connection With The Solar Pvmodule, Mppt Etc.I. 4.0 Sq Mm Single Core Multi Studs - 5M(For 1Hp/2Hp/3Hp) & 20M(For5/7.5/10/15/17.5/20 Hp)Ii. Lugs, Hdpe Pipe, Flexible Pipe, Saddle, Cable Tie Etc A) For 1 Hp/2 Hp/3Hp Per Structure (For Solar Submerssible) , Earthing: Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below: By Isi-Medium Gi Pipe Including Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming And Connecting To Individual Structure To Earth Electrode Including S&F 20 Mm X 3 Mm Galvanised (Hot Dip) Ms Flat On Wall/Floor With Gi Saddles As Required And Connection To Equipments Incl. Drilling Holes, With Bolts, Nuts, Washers Etc. , Supply Of Pvc Pipes & Fittings Schedule 40 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). (A) Pvc Pipes (Dia) 32 Mm (Patton/Polo/Utkarsh/Swastick) , Supply And INSTALLATION Of 80 Mm Bore Well 1 Hp Submesible Pump (Kirloskar/ Crompton/ C.G/ K.S.B./Cri Or Other Approved Brand As Per Direction Of Eic ( Ac/ Dc Supply 80 To 110 Volt Outlet 32 Mm ) , Supply And INSTALLATION Of 80 Mm Bore Well 1 Hp Submesible Pump (Kirloskar/ Crompton/ C.G/ K.S.B./Cri Or Other Approved Brand As Per Direction Of Eic ( Ac/ Dc Supply 80 To 110 Volt Outlet 32 Mm ) 32 Mm , Supplying, Fitting And Fixing Pvc Pipes Of Approved Make Of Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reducing Socket, Reducing Tee, Short Piece Etc. Fitted With Holder Bats, Clamps, Including Cutting Pipes, Making Threads,Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Necessary Fittings As Required,Jointing Materials And Two Coats Of Painting With Approved Paint In Any Position Above Ground. (A) For Exposed Work Pvc Pipes 32 Mm , 25 Mm , Supplying, Fitting And Fixing Bib Cock Or Stop Cock. E) Ptmt (Polytetra Bib Cock / Stop Cock ( Prayag Or Equivalent) 15 Mm , Supplying, Fitting And Fixing Stainless Steel Sink Complete With Waste Fittings And Two Coats Of Painting Of C.I. Brackets. (A) Sink Only (I) 530 Mm X 430 Mm X 180 Mm , Collecting Sample Of Water For Bacteriological And Chemical Test From Any Depth At Any Time During Execution Of Work Including Hire And Labour Charges For Tools And Plants And Sterilising The Equipments, Paying All Charges And Fees, Testing Etc. Complete In All Respect As Per Direction. , Kent And/Or Approved Brand Water Purifiers 8L Capacity With 60L/Hr Output Fully Automatic , Cess
BOQ
| Sl. No. | Item Description |
| 1 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with top enlargement of 100 mm dia. (iii) 40 mm dia. boring etc. |
| 2 | (ii) 100 mm dia. boring etc. top enlargement |
| 3 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) (i) 40 mm dia. (Patton/Polo/Utkarsh/Swastick) |
| 4 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) (ii) 100 mm dia. (Patton/Polo/Utkarsh/Swastick/Bansal) |
| 5 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. (i) 40 mm dia. |
| 6 | Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets. (i) 40 mm dia |
| 7 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (L) Reducing Socket (mm X mm) 100 X 40 |
| 8 | Supply of G.I. short piece of TATA make (Above 50mm & upto150 mm long) (ix) 100 mm |
| 9 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. |
| 10 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 11 | a) For 1 HP capacity Pump-motor set with AC / DC or hybrid input (For Solar Submerssible) |
| 12 | Cable and Accessories :Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit andother accessories as per followings with necessary connection with the Solar PVModule, MPPT etc.i. 4.0 Sq mm single core multi studs - 5m(for 1HP/2HP/3HP) & 20m(for5/7.5/10/15/17.5/20 HP)ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc a) For 1 HP/2 HP/3HP per structure (For Solar Submerssible) |
| 13 | Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 14 | Supply of PVC pipes & fittings Schedule 40 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes(Dia) 32 mm (Patton/Polo/Utkarsh/Swastick) |
| 15 | Supply and instalation of 80 mm bore well 1 HP Submesible pump (Kirloskar/ Crompton/ C.G/ K.S.B./CRI or other approved brand as per direction of EIC ( AC/ DC supply 80 to 110 Volt outlet 32 mm ) |
| 16 | Supply and instalation of 80 mm bore well 1 HP Submesible pump (Kirloskar/ Crompton/ C.G/ K.S.B./CRI or other approved brand as per direction of EIC ( AC/ DC supply 80 to 110 Volt outlet 32 mm ) 32 mm |
| 17 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats, clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (a) For Exposed Work PVC Pipes 32 mm |
| 18 | 25 mm |
| 19 | Supplying, fitting and fixing bib cock or stop cock. e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 20 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm |
| 21 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 22 | Kent and/or approved brand water purifiers 8L capacity with 60L/hr output fully automatic |
| 23 | Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender