Tender For Provision Of Electrical Connections For Smart Warehouse Project And Repair/Restoration Of Damaged Electrical Connections In Shed Nos. 1, 2 & 3 At Fsd Jaynagar Under Do Darbhanga
Tender Value
17.21 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
7 days left
EMD
34430
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Madhubani → Bihar
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Electrical Connections For Smart Warehouse Project And Repair/Restoration Of Damaged Electrical Connections In Shed Nos. 1, 2 & 3 At Fsd Jaynagar Under Do Darbhanga
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (a) 8 module horizontal |
| 2 | (b) 2 module |
| 3 | (c) 12 module |
| 4 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole |
| 5 | (b) Single Pole & Neutral |
| 6 | (c ) Triple pole |
| 7 | (d) Triple pole & Neutral |
| 8 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 3 pin 5/6 A socket outlet |
| 10 | (b) 6 pin 15/16 A socket outlet |
| 11 | (C)15/16 A Switch |
| 12 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door |
| 14 | (b) 6 way, Double door |
| 15 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 4 way (4 + 12), Double door |
| 16 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 4 way (4 + 12), Double door |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required(a) 6 x 4 sq. mm |
| 18 | (b) 3 x 4 sq. mm |
| 19 | (d) 9 x 2.5 sq. mm (For Smart Ware house) |
| 20 | (c) 6 x 2.5 sq. mm |
| 21 | (d) 3X2.5 sq. mm |
| 22 | (e) 9X1.5 sq. mm |
| 23 | (f) 6X1.5 sq. mm |
| 24 | (g) 3X1.5 sq. mm |
| 25 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a)25 mm |
| 26 | (b) 20mm |
| 27 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 28 | Supplying and fixing of 1000mm x 600mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 29 | Supplying and fixing of 600mm x 600mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 30 | Supplying and fixing of 300mm x 300mm size metallic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knob type locking arrangement including painting, making recess in wall, masonry, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 31 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.(a) 200 mm X 150 mm X 60 mm deep |
| 32 | (b) 150 mm X 75 mm X 60 mm deep |
| 33 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(a) 15/16 amps switch |
| 34 | Supplying of XLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date amendments of the following size as required.(a) 3 x 10 sq.mm |
| 35 | (b) 4 X 16 sq. mm |
| 36 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 37 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required (a).Group C |
| 38 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 39 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender