Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #56369007

Tender For maintenance of Various Colonies Under South Zone Sh:- Running, Maintenance & Operation (Rmo) Of All Internal & External E&M Installations I/C Submersible Pump Sets At Dda Office Complex, Nelson Mandela Road, Vasant Kunj.

Issued by Local Bodies · New Delhi, Delhi
Tender Value
15.20 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
0 days left
EMD
30407
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Colonies Under South Zone Sh:- Running, Maintenance & Operation (Rmo) Of All Internal & External E&M Installations I/C Submersible Pump Sets At Dda Office Complex, Nelson Mandela Road, Vasant Kunj.

BOQ

Name of Work:- M/O Various Colonies Under South Zone SH:- Running, Maintenance & Operation (RMO) of all Internal & External E&M Installations i/c Submersible Pump Sets at DDA Office Complex, Nelson Mandela Road, Vasant Kunj.
Sl. No. Item Description
1Running, Maintenance and Operation (RMO) of all Internal and External E&M Installation such as security lights, compound light, submersible pump sets, 25KVA DG set including preventive and break down maintenance as per the inventory, terms & conditions attached [1 No. Grade-2 Wireman cum Pump Operator in General Shift (9 am - 5 pm) & 1 No. Khallasi in General Shift (9 am - 5 pm)]
2Supply of 200 mm sweep Exhaust-fan with 100% copper motor rotating at min. 1000 RPM complete in all respect in PVC Body etc. complete as required.
3Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
43 x 1.5 sq. mm
53 x 4 sq. mm
6Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
720 mm
825 mm
9Supplying and fixing metal box of 200 mm X 150 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
10Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
115/6 amps switch
1215/16 A switch
133 pin 5/6 A socket outlet
146 pin 15/16 A socket outlet
15Bell Push
16Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
17Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
181 or 2 Module (75mmX75mm)
194 Module (125mmX75mm)
20Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
21Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
22Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
23Installation, Testing and Commissioning of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
24Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
25Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Single Pole
27Double Pole
28Triple Pole
29Triple Pole and Neutral
30Wiring for circuit/ submain wiring along-with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire
31Supplying, Installation, Testing & Commissioning of 22 Watt Panel light 2x2 ft. of Powder coated die cast / Extruded aluminium Body (Thickness > 1.20 mm) & System lumen efficacy >135 lm/Watt and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy > 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size CCT shall be as approved by Engineer-in-Charge as per requirement.
32Supplying, installation, Testing & Commissioning of 18-22 Watt LED surface mounted Batten light of Powder coated die cast / Extruded aluminium Body (Thickness > 1.20 mm) & System lumen efficacy >135 lm/Watt) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.
33Supplying, Installation, Testing & Commissioning of 70 Watt Flood Light, powder coated pressure die cast aluminium body & System lumen efficacy >135 lm/Watt with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size CCT shall be as approved by Engineer-in-Charge.
34Supply, Installation, Testing and Commissioning of Brush Less Direct Current (BLDC) Fan without Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
35Supply & Installation of Wall-mounted RO+UV+UF+TDS Control Kent-make Water Purifier having min. 20 L/hr flow-rate and min. 8 Litre Storage Capacity working at 230 V 50 Hz supply with minimum 1Year Brand Warranty i/c connections, fittings etc. complete as required.
36Supplying & fixing PVC insulated 3 Core 4 sq.mm PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required
37Supply of B / Medium Class GI Pipe conforming to IS:1239 Part-1 (2004) having nominal diameter of 40 mm for being lowered into bore of depth upto 120 Meter i/c all fittings & connections like SS Nipple, Teflon Tape, Bends etc. complete as required.
38Lifting of Existing Submersible Pump Set from existing office complex bore well up to 120 mtr below the ground including dismantling of G.I. pipe line, submersible cable etc. as required.
39Repair of Defective 27-Stage Submersible Pump Set of 3 phase A.C. 415 Volts, 2900 RPM, upto 5 HP rating including inspection, Rewinding, Replacement of bearing, bush, Thrust bearing, Coupling Key etc of 5 HP deep bore sub. Motor, i/c replacement of EP impellers, SS Shaft & other acessories i/c reassembling testing etc as required to and fro transportation, dismantling & reassembling, painting after repair testing from authorized repair/service centre with warranty etc.complete as required.
40Assembling and Lowering of above Submersible Pump Set into the tube well up to the required depth with the existing & new G.I. pipe and all its accessories including replacement of damaged nut-bolts, rubber gasket, jointing of delivery line electric connection with starter, testing etc complete as required.
41Repairing of Submersible Cubicle Panel including cleaning, painting, rewiring, replacement of one no. DOL 3 phase Starter (MK-1), single phase preventor, indicating Lamps, selector swtiches reconnections, replacement of thimble, MCB of phase neutral & earthing retesting complete as required.
42Rewiring for light point/ fan point/ exhaust fan point/call bell point - Group C with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required
43Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
44Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56369007
AUTHORITY Local Bodies
TENDER VALUE 15.20 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Colonies Under South Zone Sh:- Running, Maintenance & Operation (Rmo) Of All Internal & External E&M Installations I/C Submersible Pump Sets At Dda Office Complex, Nelson Mandela Road, Vasant Kunj.
Basic Detail
Tender No 16/EE/ELD-6/DDA/NIT/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 09 Jul 2026
Submission Date 14 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 15.20 Lakhs
Tender Fee Ref. Documents
EMD 30407
Exemption Available
Document List
87b27fc9-fa6e-4242-a492-133a85792571.html
BOQ_963262.xls
etendernotice16.pdf
Tendernotice_1 (5).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

87b27fc9-fa6e-4242-a492-133a85792571.html

xls

BOQ_963262.xls

pdf

etendernotice16.pdf

pdf

Tendernotice_1 (5).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders