| Sl. No. | Item Description |
| 1 | Running, Maintenance and Operation (RMO) of all Internal and External E&M Installation such as security lights, compound light, submersible pump sets, 25KVA DG set including preventive and break down maintenance as per the inventory, terms & conditions attached [1 No. Grade-2 Wireman cum Pump Operator in General Shift (9 am - 5 pm) & 1 No. Khallasi in General Shift (9 am - 5 pm)] |
| 2 | Supply of 200 mm sweep Exhaust-fan with 100% copper motor rotating at min. 1000 RPM complete in all respect in PVC Body etc. complete as required. |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
| 7 | 20 mm |
| 8 | 25 mm |
| 9 | Supplying and fixing metal box of 200 mm X 150 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 11 | 5/6 amps switch |
| 12 | 15/16 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 6 pin 15/16 A socket outlet |
| 15 | Bell Push |
| 16 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 1 or 2 Module (75mmX75mm) |
| 19 | 4 Module (125mmX75mm) |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 22 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 23 | Installation, Testing and Commissioning of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 24 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 26 | Single Pole |
| 27 | Double Pole |
| 28 | Triple Pole |
| 29 | Triple Pole and Neutral |
| 30 | Wiring for circuit/ submain wiring along-with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 31 | Supplying, Installation, Testing & Commissioning of 22 Watt Panel light 2x2 ft. of Powder coated die cast / Extruded aluminium Body (Thickness > 1.20 mm) & System lumen efficacy >135 lm/Watt and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy > 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 32 | Supplying, installation, Testing & Commissioning of 18-22 Watt LED surface mounted Batten light of Powder coated die cast / Extruded aluminium Body (Thickness > 1.20 mm) & System lumen efficacy >135 lm/Watt) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 33 | Supplying, Installation, Testing & Commissioning of 70 Watt Flood Light, powder coated pressure die cast aluminium body & System lumen efficacy >135 lm/Watt with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size CCT shall be as approved by Engineer-in-Charge. |
| 34 | Supply, Installation, Testing and Commissioning of Brush Less Direct Current (BLDC) Fan without Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 35 | Supply & Installation of Wall-mounted RO+UV+UF+TDS Control Kent-make Water Purifier having min. 20 L/hr flow-rate and min. 8 Litre Storage Capacity working at 230 V 50 Hz supply with minimum 1Year Brand Warranty i/c connections, fittings etc. complete as required. |
| 36 | Supplying & fixing PVC insulated 3 Core 4 sq.mm PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required |
| 37 | Supply of B / Medium Class GI Pipe conforming to IS:1239 Part-1 (2004) having nominal diameter of 40 mm for being lowered into bore of depth upto 120 Meter i/c all fittings & connections like SS Nipple, Teflon Tape, Bends etc. complete as required. |
| 38 | Lifting of Existing Submersible Pump Set from existing office complex bore well up to 120 mtr below the ground including dismantling of G.I. pipe line, submersible cable etc. as required. |
| 39 | Repair of Defective 27-Stage Submersible Pump Set of 3 phase A.C. 415 Volts, 2900 RPM, upto 5 HP rating including inspection, Rewinding, Replacement of bearing, bush, Thrust bearing, Coupling Key etc of 5 HP deep bore sub. Motor, i/c replacement of EP impellers, SS Shaft & other acessories i/c reassembling testing etc as required to and fro transportation, dismantling & reassembling, painting after repair testing from authorized repair/service centre with warranty etc.complete as required. |
| 40 | Assembling and Lowering of above Submersible Pump Set into the tube well up to the required depth with the existing & new G.I. pipe and all its accessories including replacement of damaged nut-bolts, rubber gasket, jointing of delivery line electric connection with starter, testing etc complete as required. |
| 41 | Repairing of Submersible Cubicle Panel including cleaning, painting, rewiring, replacement of one no. DOL 3 phase Starter (MK-1), single phase preventor, indicating Lamps, selector swtiches reconnections, replacement of thimble, MCB of phase neutral & earthing retesting complete as required. |
| 42 | Rewiring for light point/ fan point/ exhaust fan point/call bell point - Group C with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required |
| 43 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 44 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender