Tender For Faecal Sludge And Septage Management Under Jamshedpur Notified Area Committee (Jnac), Hurlung, Jamshedpur
Tender Value
3.33 Crore
Estimated cost
Bid Submission
24 Jul 2026
12 days left
EMD
3.33 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
East Singhbum → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Faecal Sludge And Septage Management Under Jamshedpur Notified Area Committee (Jnac), Hurlung, Jamshedpur
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item- A) and disposal of excavated earth as obtained to a distance upto 50 M. Including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I |
| 2 | Soling- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. |
| 3 | Centering & shuttering including strutting, propping etc. And removal of form for |
| 4 | i)Foundations, footings,bases of columns, etc. For mass concrete |
| 5 | ii)Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 6 | iii)Columns, Pillars, piers, Abutments, Posts and struts |
| 7 | iv)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 8 | v)Suspended floors, roofs, landings, balconies and access platform |
| 9 | Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level 5.3.1.2) 1:2:4 (1 Cement : 2 coarse sand (zone III) : 4 graded stone aggregate 40mm nominal size) PCC M-150 |
| 10 | Providing and laying in position of specified grade of reinforced Cement Concrete excluding the cost of centering, shuttering, finishing and reinforcement: 5.3.9.1) 1:1.5:3 (1 Cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size) Footing M-20 |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pillsters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. Above plinth level up to five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 Cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size) Pardi & column M-20 |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size) Slab M-20 |
| 13 | Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level 1:1.5:3 (1 Cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size) Grade slab M-20 |
| 14 | TMT steel- Providing tor steel reinforcement of 10mm, 12mm & 16mm diameters bar as per approved design and drawinga) 10 mm (TMT coil Fe 500) {Only valid for Tata (Tiscon), SAIL. JSPL, Electrosteel Steels Ltd. Bokaro and Vizag (RINL)} |
| 15 | Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with integral water proofing compound Liquid @ 125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-plastocrate plus, MYK proof WP 10, Fosroc-conplast X4211C, Dr. fixit Pidiproof LW + or Equivalent |
| 16 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 17 | Filling in foundation trenches and plinth in layers not exceeding 150 mm. Thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specifications and direction of E/I (Mode of measurement compacted volume). |
| 18 | Carriage of material over distance exceeding 0.50 km. including loading and unloading. |
| 19 | SS railing-Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipesof 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use |
| 20 | Providing designation 75A Brick work in C.M. (1:4) in superstructure |
| 21 | Internal wall plaster- Providing 12mm Thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 22 | Internal ceiling plaster- Providing 6mm Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 |
| 23 | Internal paint-Providing two coats of oil bound distamper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I |
| 24 | External plaster- Providing 25mm Thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 25 | External paint-Providing two coats of plastic emulsion apint of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding |
| 26 | Roof sheeting- Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete.(Weight of 5.5 Kilogram/sq.m.). |
| 27 | Rolling shutter-Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 28 | Providing and laying Double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete. Size of tile 600 x 600 mm. |
| 29 | Provide and laying 6mm. Thick mosaic flooring of approved texture and colour over 25mm thick P.C.C. (1:2:4) base with 1mm down stone chips and sand of F.M. 2.5 to 3 rubbed and polished to granolithic finish, with approved quality of carborandum stone, top layer of 6mm being laid with 4mm and down marble chips of approved quality and shade in ratio (1:2) cement and marble dust mixed in ratio of (3:1) by weight, marble chips) including casting in approved block, curing, taxes and royalty all complete as per building specification and direction of E/I b) With 100% white cement |
| 30 | Provide and laying 6mm. Thick mosaic in skirting dado, steps and pillars of approved texture and colour over 12mm thick cement plaster (1:3) base with sand of F.M. 1.5. rubbed and polished to granolithic finish, with approved quality of carborandum stone top layer of 6mm being laid with 4mm and down marble duct mixed in ratio (3:1) by weight of marble chips including cost of curing, royalty and taxes all complete as per building specification and direction of E/I with 100% white cement |
| 31 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. |
| 32 | Supplying, fitting and fixing 38mm. Thick good quality, well dressed, well seasoned wood fully paneled shutters (frame made of sal wood and panel of sisum wood) in doors and windows with 20mm. Thick panels |
| 33 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing with hot dip zinc coating including fabricating glazing with plain / obscured glass pans 5 mm thick and approved type quality and iron oxidized fixtures and fastening with guard square bars 12 mm 10 cm c/c and oil painting 2 coats etc. complete. |
| 34 | Supplying, fitting and fixing 38mm. Thick good quality, well dressed, well seasoned teak wood fully glazed shutters in doors with aluminium fittings such as hinges, sliding doors, bolts, tower bolts, handles or rings, hooks and eyes, cleats, sand blocks as per schedule and 5.5 mm. thick plain single glass fitted with teak wood beads, taxes all complete as per building specification and direction of Engineer-in-charge. |
| 35 | Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 36 | SS railing-Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipesof 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use |
| 37 | Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades and section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97% of standard proctor density etc. complete (Material obtained from Other sources). |
| 38 | Construction of granular sub-base by Plant Mix Method by providing close graded Material,mixing in a mechanical mix plant at OMC,carriage of mixed Material to work site,spreading in uniform layers with Motor Grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density complete as per clause 401.For Grading I Material. |
| 39 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (Natural Sand/ VSI grade finely washed Crushed Sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 milimetre, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor/ by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing and curing including preparation of sub-grade surface if required etc. complete. |
| 40 | Providing and laying in-situ M-30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (Natural Sand/ VSI grade finely washed Crushed Sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound/ by providing cement vata in cement Mortar 1:8 of 0.6 metre x 0.6 metre centre to centre, admeasuring 80 milimetre at bottom and 40 milimetre at top with depth of 75 milimetre and maintaining the same throughout curing period/ by any other method approved by Engineer-in-charge. |
| 41 | Paver block-Providing and fixing heavy duty inter locking concrete Rubber Mould Glossy Paving Blocks of 80 mm. thickness of having a strength of 400 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm. thick including skirting joints and cleaning etc. complete using 100% crushed sand. |
| 42 | Turfing lawns with fine grassing including ploughing, dressing including breaking of clods, removal of rubbish, dressing and supplying doobs grass roots at 10 cm apart, including supplying and spreading of farm yard manure at rate of0.6 cum per 100 sqm. |
| 43 | Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.Outside of the coumpund wall |
| 44 | Neem(Azadirachta indica) |
| 45 | Gulmohar(Delonix regia) |
| 46 | Mangifera indica (Mango) |
| 47 | Providing and fixing tree guard 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm and steel wire3 mm dia welded and fabricated as per design in two halves bolted together. |
| 48 | Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.Inside of the coumpund wall |
| 49 | Tecoma capensis (Ratanjot) |
| 50 | Tabernaemontana variegated (Chandni) |
| 51 | Hibiscus variegated (Guddal) |
| 52 | S&F following sizes of ISI marked ( IS:14927 P - II ) UPVC casing capping as per PWD specification for electrical Works along with all accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners , All as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 53 | 25 mm x 12 mm |
| 54 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq.mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS: 14927 P - II ) UPVC casing capping & it's accessories like coupler, inner, outer, elbow, square box, tee, end cap etc., Hot Dipped Galvanized Modular box of 18 SWG with earth terminal / surface Moulded UPVC Modular Box earth terminal , 6 A Modular switch , Modular face plate with grid plate, 3 pin ceiling rose/lamp holder/ 3 point connector , screws, all as per pre approved by Engineer in charge,making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 55 | Medium point (up to 6 mtr.) |
| 56 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) UPVC casing capping & it's accessories like coupler, inner, outer, elbow, square box, tee, end cap etc., Hot Dipped Galvanized Modular box of 18 SWG with earth terminal/ surface moulded UPVC Modular box, 3/5 pin 6 A modular switch, 6 A modular socket, Modular face plate with grid plate, screws, , all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 57 | On board |
| 58 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 59 | 3x 1.5 sq.mm |
| 60 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 61 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 62 | Providing & Fixing of ISI marked surface type buzzer as per PWD specification for electrical Works, (IS:2268-1994) including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 63 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 64 | 6 A one way switch |
| 65 | 16 Amp.1 Module switch With Led Indicator |
| 66 | Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . |
| 67 | 6 A 3 pin shuttered socket |
| 68 | 16 Amp.1 Module switch With Led Indicator |
| 69 | Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 70 | 5 step fan regulator 100 watt 1 Module |
| 71 | Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 72 | RJ-11 telephone jack single two line |
| 73 | RJ-45 computer jack with shutter |
| 74 | Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 75 | 1/2 Module |
| 76 | 3 Module |
| 77 | 6 Module |
| 78 | Providing & Fixing of following size polycarbonate modular boxes asper PWD specification for electrical Works, as per IS 14772-2000 in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 79 | 1-2-3 Module |
| 80 | 6 Module |
| 81 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade ark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. |
| 82 | 4' LED Tube shape fixture 18/20 W (Extruded Al Base) |
| 83 | 2' LED Tube shape fixture 9/10 W (Polycarbonate Base) |
| 84 | Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. |
| 85 | 36W LED light fixture 2'x2' with acrylic / prismatic front cover. |
| 86 | Providing & Fixing of ISO Certified company made BEE Approved copper wounded 1200 mm sweep BLDC technology power saving ceiling fan with longer life span and low maintenance 5 star rated which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 215 CMM, speed 350 RPM (tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod up to 30 cm with secondary support safety cable, cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 87 | Without Remote |
| 88 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR |
| 89 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 90 | 225 mm sweep |
| 91 | Providing & Fixing of ISO Certified company made ISI marked (IS:2082) of 5 star rated vertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device (PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloy connection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 92 | 25 Ltr. |
| 93 | Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank as per specification |
| 94 | 1 KVA |
| 95 | Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 96 | Supply & Fixing of ISI marked conforming to IS : 2878 Fire Extinguisher, Trolley mounted, CO2 (gas pressure) type capacity 22.5 Kg. with gun‐metal cap.delivery hose horn, trolley, handle, wheel type release valve, locking arrangement complete in all respect. bidder must have valid PESO license to refill and store compressed gas cylinders as per Gas Cylinder rules 2004 , vessel should be PESO Approved. carbon dioxide gas shall conform to IS 15222 with latest amendment. Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 97 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI /ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 98 | Single pole MCB |
| 99 | 6 A to 32 A rating |
| 100 | Double pole MCB |
| 101 | 6 A to 32 A rating |
| 102 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL /CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 103 | Two pole 30 mA sensitivity |
| 104 | 16/25 A rating |
| 105 | Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 106 | IP-43 Double door (single phase) |
| 107 | 4 Way (4 O/G +2 I/C ) |
| 108 | 8 Way (8 O/G +2 I/C ) |
| 109 | 12 Way (12 O/G +2 I/C) |
| 110 | Providing & Fixing of recessed/surface mounting type sheet steel / Plastic enclosure as per PWD specification for electrical Works conforming to IEC 61439-3 of not less then 1.2 mm thick for housing MCB/Isolator with Din rail including , all as per pre approved by Engineer in charge,making connections, with lugs, repairs etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 111 | With sheet steel enclosure |
| 112 | Two way |
| 113 | SITC of Main Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, MCCB -100 Amp FP for Electrical Interlock as per SLD having following items:-Main I/O 100 Amp TPN MCCB. 25 kA (Ics=100% of Icu) capacityDG I/O 100 Amp TPN MCCB. 25 kA (Ics=100% of Icu) capacity Bus bar chamber TPN & E with aluminium bars 100 A. Outgoing- 100AFP MCCB -2 Nos.40- 63A FP MCB C series -3 Nos. 6- 32A FP MCB C series -4 Nos.6-32A DP MCB C Series- 8 Nos |
| 114 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c), (d) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) ,hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 115 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 116 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 117 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 118 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 119 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 120 | Supplying, installation & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 121 | Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V, aux. supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 122 | 1.5 sqmm FRLSH Wire |
| 123 | 2.5 sqmm FRLSH Wire |
| 124 | 4 sqmm FRLSH Wire |
| 125 | 6 sqmm FRLSH Wire |
| 126 | 10 sqmm FRLSH Wire |
| 127 | Supplying and erecting hylam sheet/ ebonite sheet 3 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. |
| 128 | Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A |
| 129 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 130 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In)and adjustable time delay 100/200 millisecond suitable for up to 200A MCCB with inbuilt CTs. |
| 131 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 132 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 133 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel |
| 134 | SITC of FSTP Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh, EB and DG set metering and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden, MCCB -100 Amp FP for Electrical Interlock as per SLD having following items:-Main I/O 100 Amp TPN MCCB. 25 kA (Ics=100% of Icu) capacity40- 63A FP MCB C series -2 Nos. 6- 32A FP MCB C series -26 Nos.6-32A DP MCB C Series- 8 Nos |
| 135 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c), (d) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) ,hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 136 | Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB |
| 137 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 138 | Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 139 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 140 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 141 | Supplying, installation & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD |
| 142 | Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V, aux. supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 143 | 1.5 sqmm FRLSH Wire |
| 144 | 2.5 sqmm FRLSH Wire |
| 145 | 4 sqmm FRLSH Wire |
| 146 | 6 sqmm FRLSH Wire |
| 147 | 10 sqmm FRLSH Wire |
| 148 | Supplying and erecting hylam sheet/ ebonite sheet 3 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. |
| 149 | Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A |
| 150 | Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. |
| 151 | Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In)and adjustable time delay 100/200 millisecond suitable for up to 200A MCCB with inbuilt CTs. |
| 152 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 153 | Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. |
| 154 | Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel |
| 155 | Supplying and erecting 30 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC |
| 156 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (For LDB, UPS DB) |
| 157 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (For PDB) |
| 158 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 159 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (For all Panels) |
| 160 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( For Street Light) |
| 161 | Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. X 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (from Street Light Pole MCB to Fitting) |
| 162 | Supplying and erecting integrated LED street light fitting 48W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. |
| 163 | Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGODF /FLS2. |
| 164 | Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 165 | Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. |
| 166 | Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 167 | Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( Street Light Panel Foundation frame) |
| 168 | Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 169 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. |
| 170 | Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 171 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT |
| 172 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no.EA-EP |
| 173 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 174 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no.EA-EP |
| 175 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. |
| 176 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete |
| 177 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 178 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) for St. Light Panel + DG Set |
| 179 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. |
| 180 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 181 | Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP. |
| 182 | Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible /centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . |
| 183 | Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. |
| 184 | Supplying & erecting Water level controller 230/415 V, A.C., Four way under ground & Over head tank operation only. |
| 185 | Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 186 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. |
| 187 | Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. |
| 188 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 189 | Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 190 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 191 | Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 63 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 100 Amps as incomer & 6 Nos. 63 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 192 | Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 63 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with standard accessories complete with test certificate with losses below 340 Watts at 50% load, 1140 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 193 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 194 | Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG |
| 195 | Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. |
| 196 | Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD |
| 197 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete. |
| 198 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 kV |
| 199 | Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete |
| 200 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 7.47 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 75 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG |
| 201 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of 40 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. |
| 202 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU (for DG Set control Cabeling) |
| 203 | Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications.1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation.2. Eight Channel DVR with metal body construction, having software features of motion detect recording.3. 3.5 inch 2 GB HDD4. 8 port POE Switch5. 32 inch LED Screen, Keyboard & mouse. |
| 204 | Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 205 | Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation /structural steel support. With by-pass arrangement - PN-1 - 100 mm (ID) |
| 206 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation up to departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. Complete. Reflux valves as per I.S.5312 Part I (1984) With by-pass arrangement - PN-1 - 100 mm (ID) |
| 207 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Sluice valves - PN -1.0 (With by-pass arrangement) - 100 mm dia (ID) |
| 208 | Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 209 | Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation /structural steel support. With bypass arrangement - PN-1 - 65/80 mm (ID) |
| 210 | Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation up to departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. Complete. Reflux valves as per I.S.5312 Part I (1984) Without bypass arrangement - PN-1 - 65 mm (ID) |
| 211 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves - PN -1.0 (Without by-pass arrangement) - 65 mm dia (ID) |
| 212 | Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original pipe a) Working Pressure 6 to 12.5 Kg/Sq.cm |
| 213 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) |
| 214 | 100 mm |
| 215 | 65 mm |
| 216 | Giving satisfactory hydraulic testing of following C. I. D / F Reflex valves, Butterfly valves and Sluice valves. |
| 217 | 100 mm |
| 218 | 65 mm |
| 219 | Supply, Installation, Testing, Commissioning (SITC) of receiving chamber with screen (SS 304) with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 220 | Supply, Installation, Testing, Commissioning (SITC) of MBBR based STP - Liquid Stream with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 221 | Supply, Installation, Testing, Commissioning (SITC) of Screw press - Sludge Dewatering Machine with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 222 | Supply, Installation, Testing, Commissioning (SITC) of Sludge Drying System with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 223 | Supply, Installation, Testing, Commissioning (SITC) of Raw Sewage Pump (IST-1 to MBBR) with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 224 | Supply, Installation, Testing, Commissioning (SITC) of Sludge Pump (STT to Screw Press/Sludge Dewatering Unit) with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 225 | Supply, Installation, Testing, Commissioning (SITC) of Filter Feed Pump (IST-2 to TTS) with all necessary tools, tackles required to complete in all respect as per engineer in charge. |
| 226 | Operation and maintenance for the entire system for 1 year including cost of water, electricity, fuel, repair, renewal, consumables, cost of machinaries, maintenance cost - civil/mechanical/electrical works, manpower, material cost, safety tools, power, energy cost etc all complete as per direction of engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender