Agriculture Government Departments Closing in 6 days TDR #56364901

Tender For Development Of Infrastructure Facilities Of Jalabassa Rural Market Under Panisagar Agri. Sub-Division North Tripura District Sh/:- Providing Internal Electrification (2Nd Call).

Issued by Government Departments · tripura, Tripura
Tender Value
11.95 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
6 days left
EMD
23919
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Infrastructure Facilities Of Jalabassa Rural Market Under Panisagar Agri. Sub-Division North Tripura District Sh/:- Providing Internal Electrification (2Nd Call).

BOQ

Name of Work:- Development of Infrastructure facilities of Jalabassa Rural Market under Panisagar Agri. Sub-division North Tripura District SH/:- Providing Internal Electrification (2nd call).
Sl. No. Item Description
1Electrical work :
2Wiring for light & fan point with 2 X 1.5 sq. mm. PVC insulated copper conductor cable (FR) in PVC casing and capping complete with PVC surface modular switch board with cover plate and 10A. modular switch including connection etc. as required a) Short Point :-
3b) Medium point:-
4c) Long point:-
5Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socketincluding connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
6Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socketincluding connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required
7Wiring for circuit/sub-main wiring with theFollowingsizesPVCinsulatedcopperconductorcable (FR) in PVC casing capping including connection etc. as required. 2X1.5sq.mm.
82X2.5sq.mm.
92 x 4.00 sq mm
102 x 10 sq mm
114 x 4 sq mm
124 x 10 sq mm
13Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- 1 X 1.5 sq mm
142 x 1.5 sq mm
152 x 2.5 sq mm
162 x 4 sq mm
172 x 6 sq mm
182 x 10 sq mm
19Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required.
20Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
21Supplying and drawing 2.5 sq. mm Copper conductor wire along with other wire for loop earthing including connection etc. as required.
22Extra for using salt (5 KG) and charcoal (46 KG) for pipe earth electrode as required.
23Supplying and fixing of M.S. frame made of 25 X 25 X 5 mm. M.S. angle with necessary support by 40 X 6 mm. M.S. flat and 12mm. thick marine plywood on top, grouted on wall with 4 Nos. leg with 25X25X5mm. M.S. angle with 20 cm. long finished with red oxide and 2 coat synthetic enamel paint including necessary C.C. work, mending the damages and painting etc. as required.
24Providing and fitting fixing after necessary testing etc. of 3X35+1X10 sq. mm. PVC sheathed PVC insulated stranded Aluminum conductor single core cable of Richa/Polycab make ISI approved quality with Bobin insulator made with Porcelain, 4 sq. mm. Aluminum conductor binding wire and 8 SWG G.I. wire of approved quality complete with Catenary wiring and fixing the same with the existing supports complete with circuit wiring, connections and all other related factors a required as per direction of the Engineer-in-charge.
25Supplying and fixing of the following PVC casing capping with all accessories etc. as required. 25 x 12 mm
2638 x 16 mm
27Supplying and fixing of the following electrical accessories including necessary connection etc. as required. 32A. 1-way DP switch (2M).
2816/20 amps piano type switch
290.5watts LED retrofit colour lamp with Polycarb- -onate body and aluminium heatsink.
303 mm. thick Bakelite sheet
3119/20mm. dia. PVC conduit (medium gauge on surface) including all accessories as required.
3225mm. dia. heavy duty PVC gland.
3332mm. dia. heavy duty PVC gland.
342 module 5-step modular fan regulator in existing switch board.
35Electronic 5 step fan regulator
3625mm. dia. heavy duty PVC flexible pipe.
371-2 module plastic switch board with cover plate etc. complete as required.
38102mm. X 102mm. size PVC switch boards with cover etc.
39102mm. X 178mm. size PVC switch boards with cover etc.
401 module blank plate.
4115 mm. dia. heavy duty PVC flexible pipe.
4220 W. LED retrofit lamp with polycarbonate body and aluminum heat sink, B.C. type.
4312 W. LED retrofit lamp with polycarbonate body and aluminum heat sink, B.C. type.
44Approved quality heavy duty 16 mm dia. 150 mm long G.I fasten nut complete for installation of ceiling fan as required
45Supplying of 25 cm. long “L” hook made with 40mm. X 6 mm. M.S. flat and fixing with necessary fasten nuts including finishing, painting etc. as required.
4610A. modular SP 1-way switch (1M).
47Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required 203mm x 254mm (8\\" X 10\\") :-
48203mm x 300mm (8\\" X 12\\") :-
49254mm x 300mm (10\\" X 12\\") :-
50300mm x 380mm (12\\" X 15\\") :-
51Supplying and fixing of the following sizes PVC switch boards with cover etc. as required. 152mm x 203mm (6\\" X 8\\") :-
52203mm x 254mm (8\\" X 10\\") :-
53Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):-
54200 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):-
55Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- 200 amps 415 volts TPN main switch (rewireable):-
56Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- 100 amps 415 volts TPN main switch (rewireable):-
57Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. 2 way SPN MCB DB (single door):-
58Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. 4 way SPN MCB DB (single door):-
59(2+4) / 6 way SPN MCB DB (single door):-
60(2+6) / 8 way SPN MCB DB (single door):-
61(2+10) / 12 way SPN MCB DB (single door):-
62Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required Enclosure suitable for MCCB upto 100 amps:-
63Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):-
64Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- 6 to 32 amps SP MCB:-
656 to 32 amps DP MCB:-
66Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- 40 amps DP isolator:-
6763 amps DP isolator:-
68Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- 200/250 amps kitkat porcelain fuse unit with base(rewireable):-
69Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:-
70Surface mounted Square/round shaped 12W. LED downlight with integral driver and high qualitypolycarbonate diffuser.
71Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- 45 watt LED street light fixture with integral driver and secondary lens (IP 66):-
72Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
73Supplying & fixing of 900 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) :-
74Supplying of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades (Without regulator) (ISI marked, BEE 1 star/minimum service value 4.0m3/min/W) : -
75Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. 3 core 4 Sq mm.
76Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required - 3 core 4 Sq mm
77Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - 1.5 sqmm - 4 sqmm Cable:-
78Supplying & installation of following power contactors including necessary connection etc as required:- 3 pole 18 amps (AC3) power contactors with 1NO+1NC Aux. Contact.
79Supplying & installation of Astronomical timer Switch including necessary connection etc as required:-
80Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required:-
81Supplying & installation of 380 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56364901
AUTHORITY Government Departments
TENDER VALUE 11.95 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Department Of Agriculture
Work Description Tender for Development Of Infrastructure Facilities Of Jalabassa Rural Market Under Panisagar Agri. Sub-Division North Tripura District Sh/:- Providing Internal Electrification (2Nd Call).
Basic Detail
Tender No 08/EE/AGRI/NORTH/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 08 Jul 2026
Submission Date 14 Jul 2026
Open Date 14 Jul 2026
Finance
Tender Value 11.95 Lakhs
Tender Fee 1000
EMD 23919
Exemption Not Available
Document List
4c5b2b09-7c12-4393-a436-4ecd89ab1f69.html
BOQ_75879.xls
DNITJalabassaMarketElec.pdf
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Jul 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4c5b2b09-7c12-4393-a436-4ecd89ab1f69.html

xls

BOQ_75879.xls

pdf

DNITJalabassaMarketElec.pdf

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders