Tender For Construction Of Dining Hall For Boys (120 Seating Capacity) Old Basholi Boys Hostel And Pre-Engineering Boys Hostel At Smvd University, Kakryal, Katra

Issued by Boards / Undertakings / PSU · Reasi, Jammu and Kashmir
Tender Value
1.31 Crore
Estimated cost
Bid Submission
22 Jul 2026
10 days left
EMD
2.64 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Dining Hall For Boys (120 Seating Capacity) Old Basholi Boys Hostel And Pre-Engineering Boys Hostel At Smvd University, Kakryal, Katra

BOQ

Name of Work:- CONSTRUCTION OF DINING HALL FOR BOYS (120 SEATING CAPACITY) OLD BASHOLI BOYS HOSTEL AND PRE-ENGINEERING BOYS HOSTEL AT SMVD UNIVERSITY, KAKRYAL, KATRA
Sl. No. Item Description
1Civil Work
2Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts,wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres.
3All kinds of soil
4Filling available excavated earth (excluding rock) in trenches, plinth, foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited sides of layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
5Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
6Supplying chemical emulsion in sealed containers including delivery as specified.Chlorophriphos/Lindane emulsifiable concentrate of 20%
7Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for pre-constructional anti-trermite treatment and creating a continuous chemical barrier under and all round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of the building, expansion joint, over the top surface of consolidated earth on which apron is to be laid surroundings of pipes and conduits etc., complete as per specifications (plinth area of the building at ground floor level only shall be measured for payment) , chloropyrifos emusifiable concentrate 20% with 1% concentration
8Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
9Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.(1 kg of water proofing material in 50 kg of cement)
10Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7 kg per square meter on damp proof courses after cleaning the surface with brushes andfinally with a piece of cloth lightly soaked in kerosene oil.
11Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
121:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
13Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
141:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
15Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
16Thermo-Mechanically Treated bars of grade Fe-500D or more.
17Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections
18Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.
19All works upto plinth level
20Providing and laying in position machine batched and machine mixed design mix M-25grade cement concrete for reinforced cement concrete work, using cement content as preapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.
21All works above plinth level upto floor V level
22Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over thespecified cement content used is payable/ recoverable separately.
23Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note:- Cement content considered in M-30 is @ 340 kg/cum)
24Add or deduct for using more or less cement in the items of design mix over and above thespecified cement content therein.
25Centering and shuttering including strutting, propping etc. and removal of form for:
26Foundations, footings, bases of columns etc. for mass concrete.
27Suspended floors, roofs, landings, balconies and access platforms.
28Lintel, beams, plinth beams, girders, bressumers and cantilevers.
29Columns, pillars, piers, abutments, posts and struts.
30Stairs (excluding landings) except spiral staircases
31Edges of slabs and breaks in floors and walls
32Weather shades, chajjas, corbels etc. including edges
33Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).
34Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
35Brick work with common burnt clay (non-modular) bricks of class designation 75
36Cement mortar 1:6 ( 1 cement : 6 coarse sand)
37Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level
38Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in :
39Cement mortar 1:6 ( 1 cement : 6 coarse sand)
40Brick edging 7cm wide 11.4cm deep to plinth protection with common burnt clay (nonmodular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1Cement : 4 fine sand) and curing complete.
41Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, stairs, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels
42Granite of any colour or shade (18mm)
43Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
44Granite work
45Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete kitchen
46Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
47Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick.
48Float glass panes
495.0 mm thick glass pane (weighing not less than 12.50 kg/sqm)
50Providing and fixing ISI marked flush door shutters conforming to IS: 2202(Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
51With ISI marked M.S. pressed butt hinges bright finished of requiredsize with necessary screws (35mm)
52Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured)
53Extra for providing vision panel not exceeding 0.1 sqm in all types of flush doors (Cost of glass excluded) (overall area of door shutter to be measured)
54Rectangular or square
55Providing and fixing ISI marked oxidized M.S. spring hinges with necessary screws etc. complete:
56Double Acting Spring hinge
57150 mm
58125 mm
59ANODIZED ALUMINUM FITTINGS (All fittings shall be ISI marked) Providing and fixing ISI marked aluminum butt hinges ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
60100x75x4 mm
6175x63x4 mm
62Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.99.1 300x10 mm
63Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 9.102.1 125 mm
64Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 9.103.2 Twin rubber stopper
65Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
66Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 9.98.1 300x16 mm
67Providing and fixing circular/hexagonal cast iron box for ceiling fan clamp,of internal dia 140 mm, 73mm height, top lid of 1.5mm thick M.S. sheetwith its top surface hacked for proper bonding, top lid shall be screwed intothe cast iron/M.S. sheet box by means of 3.3mm dia. round headed screws,one lock at the corners. Clamps shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
68Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
69In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. ( wt. @ 8kg/m)
70Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
71MS tube
72Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand)
73Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
74Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
75In colour such as White, Ivory, Grey,Fume Red Brown
76Making khurras 45x45 cm with average minimum thickness of 5 cmcement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregateof 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron,finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and acoat of neat cement, rounding the edges and making and finishing theoutlet complete
77Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes
78110MM DIA PIPE
79Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion
8012.59.5 Bend 87.5°
81110MM DIA
82Providing and fixing un-plasticised -PVC pipe clips of approved design toun-plasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length, includingcutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarsesand) and making good the wall etc. complete.
83110mm
84Providing and fixing to the inlet mouth of rain water pipe cast iron grating15 cm diametre and weighing not less than 440 grams.
85CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix:
861 : 6 ( 1 cement : 6 fine sand)
8718mm Cement plaster in two coats under layer 12mm thick cement plaster1 : 5 (1 cement : 5 coarse sand) finished with a top layer 6mm thickcement plaster 1 : 3 (1 cement : 3 coarse sand) finished rough with sponge
886MM CEMENT PLASTER6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
89Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
90Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
91Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
92Providing and applying white cement based putty of specified thickness,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.( 2 mm thick )
93Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying
94:(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.
95(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with wate(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
96The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed Slurry.
97Providing and laying integral cement based water proofing treatmentincluding preparation of surfaces as required for treatment of roofs,balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cementadmixed with water proofing compound conforming to IS 2645 andapproved by Engineer-in-charge over the RCC Slab including adjoiningwalls upto 300mm height including cleaning the surface beforetreatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mmto 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarsesand) admixed with water proofing compound conforming to IS 2645and approved by Engineer-in-charge over 20mm thick layer of cementmortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with waterproofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cementslurry using 2.75kg/sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix1:4(1 cement: 4 coarse sand) admixed with water proofing compoundconforming to IS 2645 and approved by Engineer-in-charge includinglaying glass fibre cloth of approved quality in top layer of plaster andfinally finishing the surface with trowel with neat cement slurry andmaking pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for aminimum period of two weeks for curing and for final test. All aboveoperations to be done in order and as directed and specified by Engineerin-charge.
98With average thickness of 120mm and minimum thickness at khurra as 65 mm
99Fine dressing of the ground
100Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides withrequired EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.)
101Powder coated aluminum (minimum thickness of powder coated 50 microns)
102For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)
103Powder coated aluminum (minimum thickness of powder coated 50 microns)
104Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
105With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
106Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- plate etc. complete as per the direction of Engineer-in-charge. 22.4.1 With Stainless Steel cover plate minimum 1.25 mm thickness.
107Cement (avg. 50kms from Jammu)
108Sand (avg.25kms from Nagrota)
109Stone aggregate (avg.40kms from Jammu)
110Bricks (avg. 60kms)
111Steel (avg. 50kms from Jammu)
112ConcealInsidetheWallsProviding and fixing of Polyethylene/Aluminium/Polyethylene (PE-AL-PE) Composite Pipes as per IAPMO IGC- INDIA 308, UMC-1TMcertificationmarked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant DZR brass fittings as Female Elbows/Tees, MTC /FTC and Engineering plastic fittings with internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplersConnectors, clamps at one meter spacing, with PAP valves etc.MakeKitec , Maithilee and Vista.Concealed installation including cutting chasesand making good in the wall etc, Complete in all respect. (Cold and Hot)
1131620(20MMOD)PIPE
1142025(25MMOD)PIPE
115ExternalWorkProviding and fixing of Polyethylene/Aluminium/Polyethylene (PE-AL-PE) Composite Pipes as per IAPMO IGC- INDIA 308, UMC-1TM certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant DZR brass fittingsasFemaleElbows/Tees,MTC/FTCandEngineeringplasticfittingswith internal sealing system like Eq. elbows, Eq. tees, reducers, Straight couplersConnectors, with PAP valves etc.Trenching, re filling and testing etc. Complete as per Engineer In Charge.MakeKitec ,Maithilee and Vista.
1162532(32MMOD)PIPE
117DRAINAGE WORK Internal work- Exposed on wallProviding and fixing of Polyvinyl Chloride Pipe (PVC) 4kg/cm2 (0.4 MPa) class II in accordance with IS 4985 certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant Engineering plastic fittings like tees, bends, couplers, y-tee, solvent etc. Including testing of lines and joints as per Engineer in charge .Make :Finolex or equivalent
118200 MMPolyvinyl Chloride Pipe (PVC) 4kg/cm2 (0.4 MPa) class II
119160 mmPolyvinyl Chloride Pipe (PVC) 4kg/cm2 (0.4 MPa) class II
120Conceal In floorProviding and fixing of Polyvinyl Chloride Pipe (PVC) 4kg/cm2 (0.4 MPa) class II in accordance with IS 4985 certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant Engineering plastic fittings like tees, bends, couplers, y-tee, solvent etc. Including testing of lines and joints as per Engineer in charge .Make :Finolex or equivalent
121110 mm PVC pipe
12275 MM PVC PIPE
123External Work
124Providing and fixing of Polyvinyl Chloride Pipe (PVC) 4kg/cm2 (0.4 MPa) class II in accordance with IS 4985 certification marked on the pipe at the interval not greater than 1 meter with nominal pipe size with manufacturer’s name or trade mark including all relevant Engineering plastic fittings like tees, bends, couplers, y-tee, solvent etc. Including testing of lines and joints as per Engineer in charge .Make :Finolex or equivalent
125160 MM PVC
126200 MM PVC
127Providing and Fixing of PVC over water tank UV Coated 2 Layers With ISI Mark(as per IS standards of approved make and quality)
128Capacity : 2000 Litre
129Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III): 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
130Inside size 90x80 cm and 45 cm deep including C.I. cover withframe (light duty) 455x610 mm internal dimensions, total weight ofcover and frame to be not less than 38 kg (weight of cover 23 kg andweight of frame 15 kg) :
131With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
132Providing and fixing round built-in wash basin 450mm , first quality vitreous china of approved make, colour, and finish , complete with all necessary plumbing connections including labour complete
133Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand iron P or S trap, 10 liter low level white PVC flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS:7231 , with all fittingsand fixtures complete, including cutting and making good the walls and floors wherever required.
134White vitreous china Orissa W.C. pan of size 580x440 mm with integral type foot rests
135Providing and fixing wash basin with C.I. brackets, 15.. C.P. brass pillar taps , 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
136White Vitreous China flat back wash basin size 550x400mm with single 15mm C.P. brass pillar tap
137Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
138Providing and fixing 15 mm nominal bore C.P. brass long body bib cockof approved quality conforming to IS standards and weighing not lessthan 690 gms
139Providing and fixing 15mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS: 8931.
140Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931
141Providing and fixing SOAP DISH of approved quality conforming to IS standards.
142Providing and fixing C.P. NIPPLE 1” of approved quality conforming to IS standards .
143Providing and fixing C.P NIPPLE 1.5” of approved quality conforming to IS standards .
144Providing and fixing WASTE COUPLING 1.25” X 4” of approved quality conforming to IS standards .
145Providing and fixing P.V.C WASTE PIPE for sink or wash basin including waste fittings complete:
146Semi rigid pipe
14740mm dia.
148Providing and fixing C.P JAALI (HOLE) of approved quality conforming to IS standards .
149Providing and fixing P.V. CON 18” of approved quality conforming to IS standards .
150Providing and fixing 2000 litres (1000 litres each) capacity tank (OHT) on the terrace including material and labour complete
151Providing and fixing 600x450mm beveled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
152Point wiring in PVC conduit, with modular type switch
153Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required.
154Group A
155Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
1562 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
1572 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
1582 X 4 sq.mm + 1 X 4 sq.mm earth wire
1594 X 10 sq.mm + 2 X 10 sq.mm earth wire
160Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
1612 Pair
162Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
16325 mm
164SITC of 20W LED tube light T5 suitable for operation on 230V AC supply with minimum 110 lumens / watt. as per standard tested for min. 10k hours confirming minimum 50000 burning hours of life 6500K LED's only. LED Driver shall withstand 2kV surge protection.
165Supply and Fixing of ceiling fan (Aluminium Body) including wiring, the down rods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulated copper conductor single core cables,Phenolic sheet cover etc., as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge.
1661200 MM Sweep Ceiling Fan
167Supplying,Installation, testing and commissioning of pre-wired exhaust fan complete with all accessories etc. directly on wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
168600 mm sweep steel body
169Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
1701 Module Box (75mmX75mm)
1711 Module Modular Sheet with Base Plate
172Supplying and fixing following modular Switch Socket with Modular Base Plate and Cover Shee on the existing modular box including connections.
17315/16 amps switch
17416A Switch & Socket
175Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
1764 Module Box (127 mmX75 mm)
177Supplying and fixing following modular Accessories with Modular Base Plate and Cover Sheet on the existing modular box including connections.
1786 Amp 1-Way Switch
179S/F modular type electronics fan regulator :
180Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1814 Module Modular Sheet with Base Plate
182Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
18312 Module Box (203 mm x 152 mm)
184Supplying and fixing following way, three pole and neutral, prewired, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with loose wire box, terminal blocks, duly prewired with suitable size FR PVC insulatd copper conductor up to terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB / RCCB /Isolator).
1858 way (4 + 24), Double Door
186Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
187Single pole
188Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
18963 Amp
190Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 1.6mm thick CRCA sheet, hinged doors of 1.6mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required.
191Incoming: 400Amp FP, 36 kA MCCB - 1No. Adjustable thermal & adjustable magnetic setting Ics = 100% of Icu. and Rotary Handels with speader link.3 Nos. Phase indication LED lamps with 2 Amps back up MCB, breaker ' ON/OFF' indicating light with 2A MCB1 No. Intelligent multi-function digital panel meters(VAF) of class 0.5 accuracy with communication interface port R 485 for recording V (Between Phases and between each phase and neutral, A (In each phase and neutral), KWHr with suitable rating CTs, CT shorting links, R,Y, B LED indicating lamp and 2 A control SP MCB's.
192BUS BARS: Electrolytic high conductivity aluminium Four Pole (full rated)busbars rated at 433V,50 Hz., 200 amps, 35kA, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints.
193100 Amps, 415V 4P MCCB '25kA' with Double Break Rotary Mechanism and overcurrent and short circuit Thermal based release.- 2 Nos. 63 Amps, 415V 4P MCCB '25kA' with Double Break Rotary Mechanism and overcurrent and short circuit Thermal based release.- 2 Nos.Adjustable thermal & adjustable magnetic setting Ics = 100% of Icu. and Rotary Handels with speader link.3 Nos. Phase indication LED lamps with 2 Amps back up MCB, breaker ' ON/OFF' indicating light with 2A MCB1 No. Intelligent multi-function digital panel meters of class 0.5 accuracy with communication interface port R 485 for recording V (Between Phases and between each phase and neutral, A (In each phase and neutral), KWHr with suitable rating CTs, CT shorting links, R,Y, B LED indicating lamp and 2 A control SP MCB's.
194Supplying and laying of XLPE,Aluminium armoured cable of 1.1KV grade in ground including excavation,sand,brick protection,refilling the same or laying in existing pipes,existing cable tray,existing cable trench/wall with GI Clamps,on floor/wall with all haed ware and fixing arrangement etc. for surface laying as required.
1953.5 Core 95 Sqmm XLPE Alu cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56363984
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.31 Crore
LAST DATE 22-07-2026
Authority
Authority Name Shri Mata Vaishno Devi University
Work Description Tender for Construction Of Dining Hall For Boys (120 Seating Capacity) Old Basholi Boys Hostel And Pre-Engineering Boys Hostel At Smvd University, Kakryal, Katra
Basic Detail
Tender No SMVDU/Engg/Tenders/26/165 Dated 08-07-2026
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 08 Jul 2026
Submission Date 22 Jul 2026
Open Date 23 Jul 2026
Finance
Tender Value 1.31 Crore
Tender Fee 3000
EMD 2.64 Lakhs
Exemption Not Available
Document List
BOQ_1021362.xls
c904e211-ee14-46ff-b150-507338ccbf3f.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1021362.xls

html

c904e211-ee14-46ff-b150-507338ccbf3f.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender