Housing Urban and Rular Development Government Departments Closing in 0 days TDR #56363627

Tender For Develoment Of City Center At Agatti, U T Of Lakshadweep

Issued by Government Departments · Lakshadweep District, Lakshadweep
Tender Value
34.05 Crore
Estimated cost
Bid Submission
31 Jul 2026
0 days left
EMD
44.05 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lakshadweep District → Lakshadweep
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Develoment Of City Center At Agatti, U T Of Lakshadweep

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Jul-2026 corrigendum-1 Technical Technical Bid 31-Jul-2026

BOQ

Name of Work:- Develoment of City Center at Agatti, U T of Lakshadweep
Sl. No. Item Description
1Civil
2Plumbing Work
3Electrical Work
4Fire Fighting Work Please Enable Macros to View BoQ information
5Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m and more outside the periphery of the area cleared.
6Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish within 50 m lead, leveling, etc., complete.
7Earthwork in excavation by mechanical means (Hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sq.m on plan) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
8Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment. 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor:2.35.3.1 With Chlorpyriphos/Lindane E.G. 20% with 1 % concentration.
9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
10Providing and laying sub base below BBCC of Grade slab. Filling with available broken masonry/concrete debris (malba) in foundation trenches and plinth, layered filling (not exceeding 20 cm) including led, crushing, breaking compacting the debris, and filling the voids with selected earth or sand, watering and ramming etc. complete as per direction of Engineer-in-Charge. CONCRETE WORK
11Providing and laying Brick Bat Cement Concrete (1:3:6) consisting of 1 part cement, 3 parts coarse sand, and 6 parts brick bat aggregate of nominal size 40 mm in foundation and plinth, including all operations such as collection of brick bats from existing demolition debris, removing adhered mortar,crushing, breaking, grading, cleaning and washing, stacking, batching, mixing, laying in position, ramming, consolidating, grouting with cement slurry to fill voids, and curing complete for the required period. The work shall be carried out as per standard specifications and to the required lines, levels, and thickness. The rate shall exclude the cost of formwork/shuttering. Item shall be complete as per direction of Engineer-in-Charge.
12Providing and laying design mix controlled cement concrete of grade M-25 for CC work in grade slab, using approved mix design, including mixing in concrete mixer, centring, shuttering, finishing and curing complete, including cost of admixtures (Silica Fume conforming to IS 15388:2003 and chemical admixtures as per IS: 9103) but excluding cost of reinforcement As Per Direction Of The Engineer - In - Charge. (Minimum Cement content- 360Kg/Cmt). Note - Cold Joint chemical to be used for concrete
13Providing and laying in position machine batched and machine mixed M25 grade Cement Concrete in Toe wall up to 1.20m height, using special aggregate (Coconut Shell as per local availability) as partial replacement (up to 25%) of nominal size 20mm crushed stone coarse aggregate, excluding cost of centring, shuttering, finishing and reinforcement, including placing in position, compacting with mechanical vibrators, curing, etc., all complete as per the direction of the Engineer-in-charge. (Minimum Cement content- 360Kg/Cmt) Note:- Contractor has to ensure mix design and get approved from engineer in charge.
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
15Providing fusion bonded epoxy coating not less than 175 micron thickness and upto 300 micron to reinforecment bars as per IS-13620-1993/ASTM-775 M including testing of coating at plant and all taxes All dia bars and as directed by EIC.Approved Makes of Reinforcement: SAIL,TISCO.RINL,VIZAG or equivalent.
16Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts 4.3.2 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
17Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. 4.6.1A - 1 :1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25% STEEL WORKS
18Structural steel work riveted, bolted or welded in available/ built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Note - Structure should be pre fabricated at shop and should be erected on site.
19Extra over and above structural steel works for pre-fab components to be factory produced and erected on site. Including structure to be shot blasted, hot dip galvanized, coated with epoxy primer, paint and top coat with PU paint of not less than 150microns, suitable for coastal salinity and humidity as per approved drawings. Pipes shall be of TATA / JINDAL / ASIAN / APOLLO / JSW or equivalent as per Indian standards in accordance with the drawings prepared by the structural consultants and as per the general specifications. The steel work shall include all the structural members like joints, angles, plates anchor - bolts, connecting bolts including final colour and finish as per the consultants requirements suitable for coastal salinity and humidity. Colour to be approved by architect. Shop drawings to be provided for approval of the consultant before execution.
20Fabrication, transportation and installation in line and level of Architectural fabrication for cable net structure. Design; provide detailed engineering for supporting the cable net structure, supply and installation at site in the presence of engineers who will provide the cable net structure, commissioning of fabricated steel structure to support the Tensioned Membrane Structure and installing above the terrace level in position various structural items of steel, galvanized cable, All compression members; nut bolts of the cable net structure to be shot blasted, hot dip galvanized, coated with epoxy primer, paint and top coat with PU paint of not less than 150microns, suitable for coastal salinity and humidity as per approved drawings.Pipes shall be of TATA / JINDAL / ASIAN / APOLLO / JSW or equivalent as per Indian standards in accordance with the drawings prepared by the structural consultants and as per the general specifications. The steel work shall include all the structural members like joints, angles, plates anchor - bolts, connecting bolts including final colour and finish as per the consultants requirements suitable for coastal salinity and humidity. Colour to be approved by architect. Item to be executed in conjunction and by the same agency as the cable net structure. Cost to include all transportation, protective packaging, handling, insurance, wastage, clearing site after installation and any other required for successful installation and completion on site. Note - Structure should be pre fabricated at factory and should be erected on site. Design calculations to be submitted for checking by third party. Once approved, shop drawings to be provided for consultant's approval before execution.
21Providing and fixing modular weldmesh fencing system (UNICOPRIMA or equivalent approved make) comprising factory-made welded mesh panels, posts, clamps and accessories, complete as per manufacturer’s specifications and direction of architect and engineer-in-Charge. The fencing system shall consist of welded mesh panels with mesh size 200 mm (H) × 50 mm (V), panel width 2500 mm, and height as per site requirement (1260 mm / 1560 mm / 1860 mm). The panels shall be made of galvanized steel wire with polyester powder coated finish suitable for coastal salinity and humidity of approved colour. The system shall include steel posts of minimum 50 mm × 50 mm section (UNICOPRIMA type), fixed at 2560 mm centre-to-centre spacing, with post height as per requirement (1300 mm / 1600 mm / 1900 mm). Panels shall be securely fixed to posts using manufacturer’s standard clamps/fixtures with tamper-proof nuts and bolts. Posts shall be anchored to RCC/masonry/PCC base using M12 × 150 mm anchor bolts with nuts and washers. The work includes supply of all materials, panels, posts, clamps, fasteners, anchor bolts, end caps, accessories; cutting, handling, carriage, hoisting, erection, alignment, checking for line, level and plumb; and fixing in position complete, including all incidental charges as per manufacturer’s specifications. Cost to include all transportation, protective packaging, handling, insurance, wastage, clearing site after installation and any other required for successful installation and completion on site. Shop drawings to be provided for Consultant's approval before execution. MASONRY
22Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level. 7.8.2 - Masonry work (second sort), in cement mortar 1 :6 (1 cement: 6 coarse sand)
23Providing and making Gabion structure with mechanically woven double twisted hexagonal shaped wire mesh gabion boxes as per IS 16014:2012 and MORTH Clause 2500, of required size , Mesh type 10x 12 (D= 100 mm 1ith tolerance of + 2%), Zinc + 10% Aluminium Alloy +PVC coated, mesh wire diameter 2.7/3.7 mm (ID/OD), mechanically edged/selvedged with partitions at every 1 mm interval and having minium 10 nos of openings per m of mesh perpendicular to twist, tied with lacing wire of diameter 2.2/3.2 mm (ID/OD), supplied @ 3% by weight of Gabion boxes , filled with boulders having least dimension of 200mm, as per drawings , complete in all respects and as directed by engineer- in - charge. The boulders to be highly packed in the cage without any distortion in the cage. Sample to be made for approval before execution.
24Extra to be paid over and above for substituting boulders with dead corals collected from beaches.
25Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level, in cement mortar 1:4 6.13.2- 1 cement : 4 coarse sand, including curing, raking of joints, scaffolding, etc., complete. FLOORING WORK
26Providing and laying vitrified floor tiles in different sizes (thickness as specified by manufacturer), with water absorption less than 0.08% (IS 15622), of approved make, in all colours and shades, laid on 20 mm thick bed of cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg/sqm, including grouting with white cement and matching pigments, complete.
27Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :11.26.1 25 mm thickNote- Item will also be used for backing for Precast Bench - Slab or Panel. The item to include edge polishing and the thickness to be uniform.
28Providing and laying cobble stone flooring using hand dressed cobble stones of size 75mm x 75 mm x 75mm to 100 mm x 100mm x 100mm laid over 40 mm thick sand/stone dust bedding, including filling of joints with sand/ cement mortar, dressing, levelling, ramming, watering, curing and finishing complete as per direction of Engineer- in- Charge. The color to be selected by the Architect. Samples to be made for approval before execution.
29Providing and laying pebble flooring with selected natural pebbles of approved size, shade and texture embedded in cement mortar over BBCC base, including jointing,curing, washing,finishing, finishing and complete as directed. Samples of various sizes and colors of pebbles will have to be made for approval from Architect. The final surface has to be free from cement on top of finished flooring .
30Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
31Providing and laying broken China Mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over Cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall,clearing with water and oxalic acid etc. as directed.
32Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine granite cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
33Providing , supplying and fixing 8 mm thick laminated wooden flooring consisting of multi- layer construction with high- density fibreboard (HDF) core, decorative layer and wear-resistant overlay, conforming to relevant standards (EN 13329/equivalent), with AC3/AC4 abrasion class suitable for residential/light commercial use. The work shall include sub-floor preparation, moisture protection, Soundproof layer, skirting / edge finishing, trims and accessories, post installation cleaning. Thickness= 8 mm, Plank size = Approx. 1200-1220 mm x 190-200 mm, Edge profile: Tongue and groove/click-lock system, Finish: Wood grain texture Formaldehyde emission: E1/E0 grade, Abrasion class: AC3/AC4. The samples to be provided for approval of the consultant. ROOFING
34Supply and install laminated glass (Saint Gobain or equivalent) panel, in line and level, in roof and / or floor and / or facia of 6”mm tempered ST167 reflective laminated + Sentry Glass ionoplast interlayer 1.52mm + 6mm tempered clear laminated as per architect’s approved drawing. Panels to be factory cut, edge polished, delivered to site with all handling, packing and transportation charges included. Material specification: 6mm tempered clear laminated glass and ST167 reflective laminated: IS 12569 / equivalent on both outer layers. Interlayer: Dupont Sentry Glass or equivalent ionoplast interlayer with thickness as required for the structural stability of the glass to withstand natural forces. Providing high strength stiffness and impact resistance complying with relevant Indian and international standards for safety and structural performance. Finish: Clear with tint of colour and transparency as approved by architect, optically flat, edge polished with no visible bubbles, delamination or distortion. Shape and size as per architect’s drawings and approval. Rate to include all material costs, transportation to site, including loading, unloading, handling, packing, scaffolding, props, labour and expertise with installing on site complete and finished in all respects. Rate to include accessories like setting blocks rubber gaskets, edge sealed suitable for coastal salinity and humidity. Stainless steel structural fittings, clamps, or brackets, (ASTM Grade) as required. These will include patch fittings, U- clamps, channel systems. Silicon sealant / structural adhesive (clear UV resistant, marine grade) for edge bonding and glazing. Fabrication, marking, protective packaging, installation, leveling alignment, and clearing of site after installation to be all included. Backing between glass and steel to be filled by backing material. Cost to include all insurance, breakage and any other required for successful installation and completion on site. Samples to be prepared for approval from architect.
35Providing and fixing artificial thatch roof, in line and level, (Palmex or equivalent), free from micro-plastic, of approved make and quality to achieve aesthetic of traditional Dutch thatch roof, 150 mm thick, including cutting, laying, fixing with necessary supports, fasteners, with overlap joints as per manufacturers recommendations, complete as per design and directions of architect / engineer-in-charge. To be installed over wood finished roofing sheet with leak proof self-drilling screws 25mm with inbuilt washers and gaskets. The roofing sheet to be installed over aluminium framing with wood finished coating. Roofing sheet with 20-year warranty with UV stabilisation, with wood finish galvalume sheets (PPGL) with high strength coated with an aluminium zinc alloy (55% aluminium, 43% zinc and 1.6% silicon) finished with durable realistic wood grain pattern. Thickness of coating to be 0.6mm. Tensile strength of 550 MPa. Profile shape high rib corrugated sheet for structural durability. All finish including steel and coating to be suitable for coastal salinity and humidity. Edges and joints to be suitably finished for weather proofing. Samples, including edges and joints to be prepared for approval from architect. Cost to include all transportation, protective packaging, handling, insurance, wastage, clearing site after installation and any other required for successful installation and completion on site. Samples to be made before execution of work.
36Supply and commissioning of Radial Cable net structure with fabric: Supplying, transporting, installation at site & commissioning of Tensioned Membrane Structure on Radial Cable Net. Designing structure as per the Architects drawing including preparation and approved Membrane shop drawings of coated tensioned membrane roof structure with high-density coating to provide high UV resistance and long-lasting performance including coastal salinity and humidity made from Mehgies /Ferrari / Sattler companies of TF 400 / FT381 420 gsm, 3000N/5cm tensile strength, 700N tear strength with 10 yr warranty both sides pvdf lacquer with an openness factor of 30%. Including aluminium clamp bards, hardware like bolts, CSK, Allen screws, washers, keder profile extrusion to receive bolts, galvanized cables as per Indian standard. The rate includes design & detailed engineering (approved by an engineer registered under IstructE, having at least 15 years of designing tensile structures and similar roof structures, having authorised copies of non-linear design, analysis and verification software for such structures) at Kavaratti and/or Agatti Islands of Lakshadweep. Colour of fabric as per architect’s approval. All hardware and structure to be suitable for coastal salinity and humidity. Item to be executed in conjunction and by the same agency as the supporting fabrication. Cost to include all transportation, packaging, handling, insurance,wastage, clearing site after installation and any other required for successful installation and completion on site. The design calculations to be submitted for checking by third party before execution. WOOD WORK
37Providing and fixing, in line and level, factory-seasoned and chemically treated First-class Teakwood of density not less than 700 kg/m3 of various thicknesses to steel used in cladding, counter tops, seat tops, etc. including transparent clear protective coating of marine grade penetrating nano technology sealer with protego hard oil wax in natural colour applied in two coats. All details as per approved architect’s drawings to complete including all fasteners, screws, finishing in given size and profile including curvature. Cost to include all transportation, protective packaging, handling, insurance, wastage, clearing site after installation and any other required for successful installation and completion on site. Samples to be provided for approval before execution. DOOR WINDOW
38Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built-up standard tubular sections / appropriate Z sections and other sections of approved make, conforming to IS 733 and IS 1285, fixing with dash fasteners, screws, etc., including necessary fittings, including anodizing of 20 microns complete as per direction of Engineer-in-Charge.
39Providing & fixing Greenlam Sturdo Magna Collection - Fuse-In Restroom Cubicle (of following standard dimension which includes 600mm door size width) self-supporting 12mm thick compact laminates made out of, urea free, thermosetting phenolic resins treated Kraft papers as core material and Amino plastic resin treated decor papers on the finish surface, conforming to latest and applicable IS: 2046-1995, EN 438:2016 and NEMA LD3-2005 quality standards with Antivirus, Antibacterial and Antifungal properties (conforming to ISO 21702:2019, JIS Z2801:2010 and ASTM G21-2015 standards respectively) to fulfil the applicable requirements of indoor air quality certifications for Greenguard-Gold standards. This also includes providing and fixing in position necessary hardware made out of Aluminium 6063 -T6 in Charcoal black anodised finish & Zinc Diecasted Charcoal black/Antique gold anodised finish hardwares as per manufacturer’s specifications & Architects instructions like (1) SS grade 316 Spring loaded hinges in black powder coated finish with antique gold lacquered hinge covers (2) Anodized metallic antique Gold finish over Zinc die casted black charcoal finsh slide Bolt with Occupancy indicators (3) Coat hook in Anodized Antique Gold Finish on zinc Die casted body and fine spark texture on pvc parts (4) Aluminium U & F- profiles with snap fit Screw Cover made from aluminium alloy grade 6063-T6 , Anodized in Charcoal black color in matte finish (5) Zinc die casted adjustable foot ( Mid Panel Mounted or Divider Setback Leg) in dual color finish of Charcoal black and Antique gold color (6) Top rail with end cap is a Box shaped Extrusion made of aluminium alloy grade 6063-T6 in charcoal color Anodized matte finish,which will get fixed with pilasters with SS Screws, (7) Rubber noise deafening tape, (8) Screws & wall Plugs ( SS- 316 ). All screws will of 316 Grade in stainless steel. All pilasters are supported by Zinc diecasted charcoal black/anitque gold anodize finish with Mid panel mounted Set Back Leg /divider mounted straight leg, anchored to the floor with a ground clearance upto 100 to 150mm. Toilet Cubicle with standard dimension of 1985mm Height x 1000mm Width x 1500mm Depth, which includes 600mm door size width. Toilet Cubicle I-Shape (Front Partition) with standard dimension of 1985mm Height x 1000mm Width which includes 600mm door size width). PLASTER
4018 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
41Providing and applying 2-3 mm thick Plaster of Paris (POP) punning over plastered surface including surface preparation, application, finishing to smooth surface, curing (if required), complete as per direction of Engineer-in-charge. PAINT
42Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm MISCELLANOUS
43Providing and mixing integral crystalline admixture for water proofingtreatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight ofcement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer in-charge. The product performance shall carry guarantee for 10 years against any leakage.
44Supplying and fixing Double Bay Swing made of heavy-duty GI/MS tubular sections with anti-rust treatment and powder-coated finish. Item to include high-quality FRP/Plastic seats, stainless steel chains with anti-wrap bearings, safety railings, and all necessary fittings. Installation shall include foundation in PCC (1:2:4), erection, testing, and commissioning as per direction of Engineer-in-Charge. Equipment must conform to IS 9873 safety standards and be suitable for coastal conditions.Make: KOOCHIE GLOBAL / Erocon / Funriders / Playgro / OK Play or equivalent.
45Supplying and fixing Four-Seater/Two-Seater See-Saw made of heavy-duty GI/MS tubular sections with anti-rust treatment and powder-coated finish. Item to include ergonomic FRP/Plastic seats with integrated handles, shock-absorbing rubber footrests, heavy-duty central pivot bearings, and all necessary fittings. Installation shall include foundation in PCC (1:2:4), erection, testing, and commissioning as per direction of Engineer-in-Charge. Equipment must conform to IS 9873 safety standards and be suitable for coastal conditions.Make: KOOCHIE GLOBAL / Erocon / Funriders / Playgro / OK Play or equivalent.
46Supplying and fixing Stand-alone Slide (approx. 2.1m height) made of heavy-duty GI/MS tubular sections with anti-rust treatment and powder-coated finish. Item to include a UV-stabilized FRP/Plastic slide chute, non-slip wide steps/ladder, safety handrails, and a landing buffer. Installation shall include foundation in PCC (1:2:4), erection, testing, and commissioning as per direction of Engineer-in-Charge. Equipment must conform to IS 9873 safety standards and be suitable for coastal conditions.Make: KOOCHIE GLOBAL / Erocon / Funriders / Playgro / OK Play or equivalent.
47SITC of PYLON TOWER : For Single Side: Cost of Supply & Fixing Name PYLON having Co-Sign H Section Profile (from Belgium) with Silver Grey Anodised , illuminate with LED & supported by M.S. Structure of 50 mm x 50 mm tubular section. ACP Sheet - 3 mm thickness will covered with Router through cut on CNC by which Light can be Illuminate Acrylic Sheets (3.0 mm) will be provide for Campus Title & Amenities. Diffuser Sheets : Vertically fixed on Right & Left Side of Pylon in which Blue Light will pass. Base Plate : 10 mm Thick fixed chemical anchor ( by Hilti) Size of Pylon : 144\\" x 42\\" x 4\\" [ Ht x W x Depth - in inch]
48SITC of Aluminium Modular Sign For MAP : For Single Side: Cost of Supply & Fixing Name Backlt Aluminium Modular SIGN for MAP having Aluminium Profile ( Aluminium Alloy-6063-T6) with Silver Satin Anodised & supported by M.S. Structure of 50 mm x 50 mm tubular section. FRONT FASCIA - Textile Fabric Media with Silicon Strip PRINT : Dye Sublimated /UV -on Latex Platform Base Plate : 8 mm Thick fixed chemical anchor ( by Hilti) Size : 48\\" x 96\\" x 4\\" [ Ht x W x Depth - in inch
49Providing and fixing high-density, polymerically bound recycled rubber safety edging (E-shape or L-shape profile) designed for playground safety. The edging shall have a rounded safety top to eliminate trip hazards and provide soft impact protection. Material must be UV-stabilized, weather-resistant, and non-toxic.Specifications:Dimensions: Typical sections of 1100mm x 130 mm 50 mm (Length x Height x Width). Installation: To be secured using heavy-duty plastic or galvanized steel anchoring pins (minimum 250 mm length) through pre-drilled holes into the sub-base. Sections shall be interlocked or butt-jointed with polyurethane adhesive for a seamless finish.Finish: Slip-resistant surface, available in Terracotta, Green, or Black.Make: KOOCHIE GLOBAL / Erocon / Funriders / Playgro / OK Play or equivalent. FURNITURE
50Fabricating and placing in position MS dust bins as per the designs. The rates shall be inclusive of all MS sections, MS sheets, MS perforated sheets, MS base and shoe plates of 8mm thickness, MS angles, heavy duty pivots, excavation, M25 precast RCC base blocks and grouting of the dust bin supports as per designs and fixing the same using 12mm dia anchor bolts. The rates shall also include for applying Duco putty and marine grade paint in two coats of approved colour and make.
51Providing and fixing Glass Fiber Reinforced Concrete (GRC) Chair of approved design and profile, manufactured using white Ordinary Portland Cement (OPC) of approved make such as Ultratech / Birla White / JK White, crushed coloured stone aggregates of various grades, 90% silica sand, AR grade glass fibers comprising Roving (AR2500H103) and Chopped Strand (ACS13PH901X), reinforcement steel Fe-415 only, potable water, approved plasticizer and polymer admixtures, and pure iron oxide pigments, including moulding, casting, curing, finishing, reinforcement, lifting, transportation, installation and all necessary fixtures and accessories complete as per approved drawings and specifications.The GRC chair shall be of size, shape and thickness as indicated in the drawings, with colour, texture and finish as selected and approved by the Architect/Engineer-in-Charge. The rate shall include all labour, materials, scaffolding, handling and complete installation at all levels, finished complete in all respects.The rate is inclusive of Transportation and packing charges. HORTICULTURE
52Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
53Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
54Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).
55Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 4.75 mm
56Rough dressing the trenched ground including breaking clods.
57Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.
58Fine dressing of the ground.
59Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
60Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
61Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)(A) Holes 90 cm dia, and 90 cm deep
62(B) Holes 60 cm dia, and 60 cm deep
63Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).
64Flooding the ground with water including making kiaries and dismantlingthe same.
65Topiary cutting/shapping of plant removing of cut materials, cleaning, hoeing of plants complete design hoeing of trees (Topiary) watering manure etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. Height of Topiary above 120 cm.
66Complete maintenance of trees, jobs like making of basin at regular interval,application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) as per direction of officer in chargePAYMENT SHOULD DONE MONTHLY
67Complete maintenance of shrubs (outside garden features), jobs like making of basin at regular interval,application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.PAYMENT SHOULD DONE MONTHLY
68Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge
69Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserviceable material’s as per direction of officer in charge (excluding cast of plant & water)(A) Shrubs : Aloe Vera Draceana trifasciata(Snake plant) Aglaonema red plant Red Draceana Chlorophytum comosum Eranthemum red Plectranthus scutellarioids (Coleus Plant) Red palm
70Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserviceable material’s as per direction of officer in charge (excluding cast of plant & water)(A) Trees : Beach Cordia Golden Shower Gulmohar Indian Almond Tree (Terminalia Arjuna) Lantern Tree Pipal Tree Plumbing Work Item No. Description of Work Unit Qty. Rate Amount Amount in Words
71SANITARY INSTALLATIONS :-Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
72Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) Stainless SteelAISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
73Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever W.C. pan with ISI marked white solid plastic seat and lid
74Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors W.C. pan with ISI marked white solid plastic seat and lid
75Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete
76Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge
77Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal.
78Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
79Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
80Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern
81Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
82Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
83Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : Single squatting plate with 5 litre P.V.C. automatic flushing cistern
84Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern
85Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
86Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
87Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of White Vitreous China Flat back wash basin size 450x 300 mm with single 15 mm C.P. brass pillar tap
88Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
89Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked
90Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of Stainless SteelAISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap
91Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap
92Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
93Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
94Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm
95Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board ,610x510 mm bowl depth 200 mm
96Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board ,610x460 mm bowl depth 200 mm
97Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. Size 450x300x150 mm
98Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40 mm C.P. Size 600x450x200 mm
99Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm
100Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge
101Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
102Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia
103Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40mm dia.
104Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40mm dia.
105Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Circular shape 450 mm dia
106Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Rectangular shape 453x357 mm
107Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Oval shape 450x350 mm (outer dimensions)
108Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete Rectangular shape 1500x450 mm
109Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete
110Providing and fixing toilet paper holder :C.P. brass
111Providing and fixing toilet paper holder :Vitreous china
112Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
113Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms
114Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
115Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
116Providing and fixing PTMT towel rail complete with brackets fixed to 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
117Providing and fixing PTMT towel rail complete with brackets fixed to 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190
118Providing and fixing of Jaquar Urinal Partition (Model no.- 1810-UC /1810-US) made of 8mm colour chrome Toughened Glass & Frosted in Curved Shaped height 900 mm width 450mm or equivalent make including all necessary fitting to be fixed by drilling holes with Brass bracket in Chrome finish all Complete as per drawing and directed by engineer-In-Charge. ( Cera/ Jauar/ Hindware/ Parryware or any other make as approved by the chief engineer)
119Providing & fixing Single Lever concealed Diver with Over head wall Shower and Spout Assembly, ( Cera/ Jauar/ Hindware/ Parryware or any other make as approved by the chief engineer)
120Providing & fixing of Health faucet with Angular Cock Assembly( Cera/ Jauar/Hindware/Parryware or any other make as approved by the chief engineer)
121Handicaped ToiletProviding and Fixing Handicap Toilet set including EWC, Cistern, Seat Cover, Fittings, Washbasin,, Hinged Rail, Grab Bar and Faucet with Spatula Lever including Cast Iron chair backed and necessary bolts and nuts complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required to the satisfaction of Engineer-In-Charge. Special Needs Toilet Set: Jaquar - CNS-WHT- 755SN + Cistern Set CNS-WHT-207, Wash Basin CNS-WHT-811 & Grab Bar 2 No. - WAC-WHT-BG0800 & WAC-WHC-BR0600 - 2 nos.+ or Equivalent approved Make ( Cera/ Jauar/Hindware/Parryware or any other make as approved by the chief engineer)
122Providing and fixing 2 Nos. support arms and backrest to mount at fixed height (Commander or equivalent) for handicap toilet complete as recommended by the E-I-C. ( Cera/ Jauar/Hindware/Parryware or any other make as approved by the chief engineer)
123Providing and fixing raised toilet seat with cover for handicap toilet (Commander or equivalent) as recommended by the E-I-C ( Cera/ Jauar/Hindware/Parryware or any other make as approved by the chief engineer)
124Providing and fixing brackets, tracks with flexible feed & waste pipes for adjustable type wash basin complete as recommended, for handicap toilet (Commander or equivalent) ( Cera/ Jauar/Hindware/Parryware or any other make as approved by the chief engineer)
125Providing and fixing central hole basin Pressmatic Pillar cock, with required braided pipes from basin pillar tap to angular stop cock,heavy duty CP connections, etc complete.( Cera/ Jaquar/Hindware/Parryware or any other make as approved by the chief engineer)
126Supplying & Installing & fixing of Flush Valve Auto operation cock with wall Flange 32mm with lever knob complete in all respects including cutting and making good the walls etc.( Cera/ Jaquar/Hindware/Parryware or any other make as approved by the chief engineer) 32mm dia.DUAL FLUSH METROPOLE FLUSH VALVE
127Providing & fixing in position 15 mm C.P. brass 2-way bib cocks of best quality (as approved by the Engineer-in-Charge).( Cera/ Jaquar/Hindware/Parryware or any other make as approved by the chief engineer)
128Providing & fixing in position 15 mm C.P. brass Pressmatic bib cocks of best quality (as approved by the Engineer-in-Charge).( Cera/ Jaquar/Hindware/Parryware or any other make as approved by the chief engineer)
129Providing and fixing Trap Grating - 150 x 150mm S.S. jali scread down or hinged grating including the cost of cutting and making good the walls. ( Grating:- Chilly, Camry, Floora or Eq. make)
130Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
131Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
132Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
133Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
134Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
135Providing fixing, testing and commissioning in position 3 Rmt Silensio/Hulliot/Astral Heavy Duty PP PIPE Noiseless Ring fit pipe including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including cutting holes in walls and making good the same. (For Chemical/Kitchen/Medical waste Drain ) (Astral/ Hulliot/ Ashirvad Makes) 160MM dia.
136Providing fixing, testing and commissioning in position 3 Rmt Silensio/Hulliot/Astral Heavy Duty PP PIPE Noiseless Ring fit pipe including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including cutting holes in walls and making good the same. (For Chemical/Kitchen/Medical waste Drain ) (Astral/ Hulliot/ Ashirvad Makes) 110MM dia.
137Providing fixing, testing and commissioning in position 3 Rmt Silensio/Hulliot/Astral Heavy Duty PP PIPE Noiseless Ring fit pipe including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/plugs etc. jointing with PVC Adhesive joints including cutting holes in walls and making good the same. (For Chemical/Kitchen/Medical waste Drain ) (Astral/ Hulliot/ Ashirvad Makes) 75MM dia.
138Providing & fixing Silensio/Hulliot/Astral Heavy Duty PP PIPE Noiseless Ring socket & spigot Trap as per IS: 3989 , Floor Trap OR multi floor trap of 100mm dia diameter, with necessary distance piece of 75mm dia pipe and 150x150mm grating, making necessary SLAB /WALLholes and cutting walls, etc complete
139Providing , Lowering Laying & fixing PVC Pipe ISI marked brand as per IS:4985 (6 kg.) complete with PVC Fittings & clamps & hinges including cutting and making good the walls & ceiling for waste pipes, connections & as directed by the Engineer-in-Charge.For Basin , Sink, urinal washout pipe 40mm (Supreme/ Astral Makes)
140Providing , Lowering Laying & fixing PVC Pipe ISI marked brand as per IS:4985 (6 kg.) complete with PVC Fittings & clamps & hinges including cutting and making good the walls & ceiling for waste pipes, connections & as directed by the Engineer-in-Charge.For Basin , Sink, urinal washout pipe 50mm (Supreme/ Astral Makes)
141Providing and fixing FRP/G.I./M.S. With coated holder-bat clamps of approved design to PVC pipe embedded in wall/ floor/ and including L- Brackets, Runner Strips, anchore, fashtner, grouting etc. Complete works.( Chilly, Intellotech, or Eq. Make) for 160mm dia pipe
142Providing and fixing FRP/G.I./M.S. With coated holder-bat clamps of approved design to PVC pipe embedded in wall/ floor/ and including L- Brackets, Runner Strips, anchore, fashtner, grouting etc. Complete works.( Chilly, Intellotech, or Eq. Make) for 110mm dia pipe
143Providing and fixing FRP/G.I./M.S. With coated holder-bat clamps of approved design to PVC pipe embedded in wall/ floor/ and including L- Brackets, Runner Strips, anchore, fashtner, grouting etc. Complete works.( Chilly, Intellotech, or Eq. Make) for 75mm dia pipe
144Providing and fixing FRP/G.I./M.S. With coated holder-bat clamps of approved design to PVC pipe embedded in wall/ floor/ and including L- Brackets, Runner Strips, anchore, fashtner, grouting etc. Complete works.( Chilly, Intellotech, or Eq. Make) for 50mm & 40mm dia pipe
145Providing and fixing FRP/G.I./M.S. With coated holder-bat clamps of approved design to PVC pipe embedded in wall/ floor/ and including L- Brackets, Runner Strips, anchore, fashtner, grouting etc. Complete works.( Chilly, Intellotech, or Eq. Make) for 32mm & 25mm /20mm/15mm dia pipe
146Providing & Making Khurras 45x45cm with avarage minimum thickness of 5 cm. cement concrete 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement: 3 corse sand) and a QUOTE of neat cement rounding the edge sand making and finishing the outlet complete, The scope are including providing & fixing to the inlet mouth of rain water pipe S.S./ Gunmetal/FRP grating 15cm diameter not less than 440grams. (FRP Grating Cover will Supply by Client)
147Making holes upto 50mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or any other make as approved by the chief engineer. including disposing the debries,all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC .
148Making holes upto 100mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or any other make as approved by the chief engineer. including disposing the debries,all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC ..
149Making holes upto 150mm dia. 300mm long in any RCC members by diamond Core Cutting machine of HILTI or any other make as approved by the chief engineer including disposing the debries all works refinishing of the GP-2 pipe grout complete with water proof testing etc completed as directed by E.T.C/PMC .
150PVC PIPE SLEEVE WORK DURING CONSTRUCTION PHASE:-Providing and fixting of the PVC - 6kg. pipe sleeves of 75mm, 100mm & 150mm dia pipe during civil work casting works, the lenght of pipe should be 450mm and 300mm as per the requirments, the sleeve works must be coordinated with the civil agency, beam, sleeves, slab and RCC reating walls etc. complete as directed by EIC/Architect
151WATER SUPPLY :-Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, Internal work - Concealed piping Works :- 15mm Dia.
152Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, Internal work - Concealed piping Works :- 20mm Dia.
153Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, Internal work - Concealed piping Works :- 25mm Dia.
154Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, Internal work - Concealed piping Works :- 32mm Dia.
155Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, External Shaft & Terrace Wall - piping Works :- 15mm Dia.
156Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, External Shaft & Terrace Wall - piping Works :- 20mm Dia.
157Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, External Shaft & Terrace Wall - piping Works :- 25mm Dia.
158Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, External Shaft & Terrace Wall - piping Works :- 32mm Dia.
159Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge, External Shaft & Terrace Wall - piping Works :- 40mm Dia.
160Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. External Shaft & Terrace Wall - piping Works :- 50mm Dia.
161Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 15mm Dia.
162Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 20mm Dia.
163Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 25mm Dia.
164Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 32mm Dia.
165Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 40mm Dia.
166Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 50mm Dia.
167Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 65mm Dia.
168Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :- 80mm Dia.
169Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :-100mm Dia.
170Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. External -Underground - piping Works :-150mm Dia.
171Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 15mm dia.
172Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20mm dia.
173Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 25mm dia.
174Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32mm dia.
175Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 40mm dia.
176Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50mm dia.
177Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65mm dia.
178Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80mm dia.
179Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
180Providing and fixing brass stop cock of approved quality : 20 mm nominal bore
181Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
182Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
183Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
184Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
185Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
186Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
187Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
188Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts 100mm dia. Class.II
189Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts 150mm dia. Class.II
190Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore
191Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
192Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore
193Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 25 mm nominal bore
194Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 32 mm nominal bore
195Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 40 mm nominal bore
196Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 50 mm nominal bore
197Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 65 mm nominal bore
198Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical : 80 mm nominal bore
199Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep(inside)withchainedlidandRCCtopslab1:1.5:3mix(1cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class
200Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep(inside)withchainedlidandRCCtopslab1:1.5:3mix(1cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished With common burnt clay F.P.S.(non modular) bricks of class
201Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
202Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm dia
203Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 80 mm dia
204Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore
205Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 100 mm dia nominal bore
206Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -15mm dia pipe
207Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -20mm dia pipe
208Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -25mm dia pipe
209Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -32mm dia pipe
210Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -40mm dia pipe
211Providing and fixing 9 mm thick nitrial electrometic insulation tube over pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (Internal work : inside the wall / covered installation/) (Tharmaflex, Accoflex, Superloan Makes) for Hot water -50mm dia pipe
212DRAINAGE & SEWERAGE & RAIN DRAIN :-Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depthupto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia. butnot exceeding 300 mm dia
213Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
214Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :100mm dia pipe
215Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :150mm dia pipe
216Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :200mm dia pipe
217Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :250mm dia pipe
218Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :300mm dia pipe
219Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 150 x 100 mm size P type With common burnt clay F.P.S. (non modular)
220Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 180 x 150 mm size P type With common burnt clay F.P.S. (non modular)
221Providing and fixing ECO Drain Pipes in including supporting the ECO Drain pipe on the bricks at each joint including leakproof joints ECO Drain Pipe etc., complete. 160mm dia.pipe( Astral/ Ashirvad/ Supreme/Finolex or Eq. Make)
222Providing and fixing ECO Drain Pipes in including supporting the ECO Drain pipe on the bricks at each joint including leakproof joints ECO Drain Pipe etc., complete. 200mm dia.pipe( Astral/ Ashirvad/ Supreme/Finolex or Eq. Make)
223Providing and fixing ECO Drain Pipes in including supporting the ECO Drain pipe on the bricks at each joint including leakproof joints ECO Drain Pipe etc., complete. 315mm dia.pipe ( Astral/ Ashirvad/ Supreme/Finolex or Eq. Make)
224Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe
225Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
226Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
227Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
228Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe
229Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
230Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular
231Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular)
232Extra for depth for manholes : Size 90x80 cm With Sewer bricks conforming to IS : 4885
233Extra for depth for manholes : Size 120x90 cm With With common burnt clay F.P.S. (non modular)
234Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
235Supplying and fixing C.I. cover without frame for manholes : 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg
236Supplying and fixing C.I. cover without frame for manholes :500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 560 mm diameter C.I. cover (heavy
237Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality M D - 10 Square shape 450 mm internal dimension
238Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality M D - 10 Circular shape 500 mm internal diameter
239Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20 Circular shape 560 mm internal diameter
240Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg
241Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class
242Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast R.C.C. horizontal grating with frame and vertical grating With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
243Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
244RAIN WATER PERCOLATION:-Boring/drillingborewellofrequireddiaforcasing/strainerpipe,bysuitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
245Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
246Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
247Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer- in-charge
248Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
249Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer- in-charge.
250Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
251Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement
252Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
253Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm dia
254Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of 200 mm dia
255PUMPS & EQUIPMENTS :-HYDRO PNEUMATIC SYSTEM:-Supply, installation, testing & commissioning of VFD based Hydropneumatic system with FRP tank, pump-motor set, suction delivery valves & pipe, all instrumentation viz. Pressure switch, pressure gauge, level indicator, etc, starter panel (including one main pump & one trimmer pump shall have VFD), cables, etc. FRP Hydropneumatic Tank with inter connection and suitable connections such as inlet, drain, outlet, pressure gauge, union connection, isolation valve, outlet pipe (to be connected to the header pipe), pressure switch, outlet valves, mounting pads, etc. with all accessories. vertical booster pumps directly coupled with the motor with SS casing, SS impeller, SS shaft and driven by 415 V AC, 3 phase, 50 Hz.motor running at 2900 RPM speed and shall be supplied with all accessories viz. strainer / dry run protection/foot valve, base plate, coupling, etc.complete. The scope shall also include suction & delivery piping & valves.( Domestic )( Grundfos, ITT Lowara, or Eq.Make)Domestic Water Supply System :7.50m3/hr x 2 Nos. main Pumps ( 2 Working + 1 Stand by Set)Head : 45 mtr.Booster Tank : 100 ltrs. x 1 nos.
256FLUSHING :-HYDRO PNEUMATIC SYSTEM:-Supply, installation, testing & commissioning of VFD based Hydropneumatic system with FRP tank, pump-motor set, suction delivery valves & pipe, all instrumentation viz. Pressure switch, pressure gauge, level indicator, etc, starter panel (including one main pump & one trimmer pump shall have VFD), cables, etc. FRP Hydropneumatic Tank with inter connection and suitable connections such as inlet, drain, outlet, pressure gauge, union connection, isolation valve, outlet pipe (to be connected to the header pipe), pressure switch, outlet valves, mounting pads, etc. with all accessories. vertical booster pumps directly coupled with the motor with SS casing, SS impeller, SS shaft and driven by 415 V AC, 3 phase, 50 Hz.motor running at 2900 RPM speed and shall be supplied with all accessories viz. strainer / dry run protection/foot valve, base plate, coupling, etc.complete. The scope shall also include suction & delivery piping & valves.( Flushing & Irrigation )( Grundfos, ITT Lowara, or Eq.Make)Flushing Water Supply System :6.0m3/hr x 2 Nos. main Pumps ( 2 Working + 1 Stand by Set)Head : 45 mtr.Booster Tank : 100 ltrs. x 1 nos.
257Suppying, installing, testing and commissioing of centrifugal monoset submersible pumps with c.i. casing, Bronze impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, starter panel, cabling up to panel, earthing,delivery & header pipes & valves etc., complete. (Domestic RAW water UGT to WTP Softener Feeder)( Grundfos, ITT Lowara, or Eq.Make)Capacity : 7.0 mtr3/hr.2 Nos. pumps ( 1 Working + 1 Stand by Set)Head : 25 mtr.
258DRAIN PUMPS ( RAIN WATER DEWATERING PUMP) ()Supply, installation, testing & commissioning of Submersible type drain sump pump having CI casing & SS impleller. The scope shall also include necessary PVC piping with delivery isolation valve & NRV with starter panel, etc. complete. (for Pump Room / Basement Wash Area Drain ) ( Grundfos, ITT Lowara, or Eq.Make)Capacity : 10 mtr3/hr. ( Solid Handling Capacity up to 32-50mm)( 1 W + 1 S)Head : 10 mtr.
259Suppying, installing, testing and commissioing of Vertical Multistage Booster Pump with c.i. casing, Bronze impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, starter panel, cabling up to panel, earthing,delivery & header pipes & valves etc., complete. (Domestic Pressure Pump lvl.)( Grundfos, ITT Lowara, or Eq.Make)Capacity : 7.5 mtr3/hr.2 Nos. pumps ( 1 Working + 1 Stand by Set)Head : 35 mtr. Booster Tank 100 ltr.
260Suppying, installing, testing and commissioing of Horizontal Multistage Booster Pump with c.i. casing, Bronze impeller, SS Shaft and driven by 415 V AC, 3 phase, 50HZ., motor running at 2900 rpm speed and shall be supplied with all accessories viz., base plate, coupling, motor, starter panel, cabling up to panel, earthing,delivery & header pipes & valves etc., complete. (Domestic Pressure Pump at Terrace lvl.)( Grundfos, ITT Lowara, or Eq.Make)Capacity : 6 mtr3/hr.2 Nos. pumps ( 1 Working + 1 Stand by Set)Head : 30mtr.Booster Tank 60 ltr.
261WTP/ SOFTENER PLANT SYSTEM:- CENTRALIZED SYSTEM ( LOCATION AT BASEMENT LVL.) -Supply installation, testing and commissioning of dometic water treatment plant comprising of pressure sand filter, multi media, activated carbon filter, chlorination, etc. accrording to input water quality/analysis. The scope shall include interconnection piping, valves, instruments, back wash arrangement, etc. complete ( Paintair , Ionexchange, Tharmax, PowerH2o Make) Input Flow Rate : 7.5. mtr3/hr.Output water : As per IS requirment < 10 PPM Supply installation, testing and commissioning of online softner plant consisting of fiber glass reinforced plastic (FRP) tank, filter media, resins, piping, isolation valves, instruments supports, etc. complete. Input Water Hardness :- 800 PPM to 1000 PPM ( As per Water Test can be verify )Output Water Hardness : < 50 PPM ( 50m3/day Req.)
262STP PLANT :-Supply, installation, testing & commissioning of Sewage Treatment Plant with all electromechanical equipments, interconnected piping, valves, pumps, instaruments, gauges, electrification like panel, starter, cabling, earthing, etc. & all accessories required as per specifications. Design & Construction of RCC tanks including collection & treated waste water tank min 1 day storage req. with manhole cover & all accessories required to complete the job ,Operation & maintennace of Sewage Treatment Plant with all spares, tools, consumables, hardwares, testing, man power, etc. Connection underground sewage line to STP with required civil works of collection tank of 25m3 other civil structure of the pump room of the plant, equilization tank, areation tank etc all included in the scope., piping work & accessories,Connection of Treated waste water overflow to the nearest drain with required civil, piping work & accessories,Connection of Treated waste water overflow to the nearest drain with required civil, piping work & accessories,Bypass connection of STP to required drain point with required civil, piping work & accessories (Envisol/ Ion Exchange, Sintex & Power H2o Make)Capacity : 22 cu. mtr./ per day ( OUT Put Perameter as Per Flushing & Irrigation Reuse water req. quality , Pollution Control board Laws)
263WATER COOLER ; Supply, installation, testing & commissioning of S.S. storage type water cooler with inbuilt with on line U.V. fultration along with built all intercnnectio piping, supports and valve and other electrical requirment ,along with inbuilt storage tank with nessesarry accessories, safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Voltas, Blu star, Power H2o Make) Capacity : 50 storage capacity. Complete as directed by site eng. incharg.
264WATER COOLER ; Supply, installation, testing & commissioning of S.S. storage type water cooler with inbuilt with on line U.V. fultration along with built all intercnnectio piping, supports and valve and other electrical requirment ,along with inbuilt storage tank with nessesarry accessories, safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Voltas, Blu star, Power H2o Make) Capacity :150 storage capacity. Complete as directed by site eng. incharg.
265TERRACE LVL. R.O PLANT ; Supply, installation, testing & commissioning of 1000 ltr. /hr. R.O.plant with including PVC RO. Water Tank of 2000 LTR. CAP. Sintex make 3 layer and Product water Tank also Included in 3 layser type, The R.O.plant including of primary & seconadary tratent with on line U.V. fultration along with built in booster pumps all intercnnectio piping, supports and valve and other electrical requirment ,safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Pentair, Power H2O,Ion Exchange, Tharmex, Make) Capacity : 1000/hr. R.O.plant complete job.Inlet Water Quality :- ( Quality To Be Chq.)( As per Bore Water Test can be done by bidder.)Flow Rate of the System :- 1000 ltr/hr./ Feed Flow Rate : 2000 LPH/ Product Flow Rate : 1000 LPH/ Reject Flow Rate : 1000 LPH/ Operating Pressure : 12-13 kg/cm2/ Recovery : 50% to 70%
266R.O PLANT ; Supply, installation, testing & commissioning of 150 ltr. /hr. R.O.plant with including PVC RO. Water Tank of 150 LTR. CAP. Sintex make 3 layer and Product water Tank also Included in 3 layser type, The R.O.plant including of primary & seconadary tratent with on line U.V. fultration along with built in booster pumps all intercnnectio piping, supports and valve and other electrical requirment ,safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Pentair, Power H2O,Ion Exchange, Tharmex, Make) Capacity : 150/hr. R.O.plant complete job.Inlet Water Quality :- ( Quality To Be Chq.)( As per Bore Water Test can be done by bidder.)Flow Rate of the System :- 1000 ltr/hr./ Feed Flow Rate : 300 LPH/ Product Flow Rate : 150 LPH/ Reject Flow Rate : 150 LPH/ Operating Pressure : 12-13 kg/cm2/ Recovery : 50% to 70%
267KITCHEN LVL. R.O PLANT ; Supply, installation, testing & commissioning of 15 ltr. /hr. Domestic R.O.plant with including , The R.O.plant including of primary & seconadary tratent with on line U.V. fultration along with built in booster pumps all intercnnectio piping, supports and valve and other electrical requirment ,safety valve, air valve, drain arrangement, all insturumentation, base frame, necessary electrification, etc. complete for Drinking Water supply. ( Pentair, Power H2O,Ion Exchange, Tharmex, Make) Capacity : 15/hr. R.O.plant complete job.
268Providing and fixing of electrical instantaneous and Storage type water Geyser of approved make 6 LTR CAP. JAQUAR A-O SMITH JAQUAR/ ELENA MODEL
269Providing and fixing of electrical instantaneous and Storage type water Geyser of approved make 15 LTR CAP. JAQUAR A-O SMITH JAQUAR/ ELENA MODEL
270PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 200 mm pipe dia x 600mm length
271PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 150 mm pipe dia x 600mm length
272PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 100 mm pipe dia x 600mm length
273PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 80 mm pipe dia x 600mm length
274PUDDLE SLEEVES:-Providing & Installing of the G.I. heavy duty Puddle Sleeve in the UGT & OHT water tanks , durring the construction of the RCC tanks. The pipe and flazes nut bolt material are as per the IS recommondation must be follow. all works must properly finishing as per site eng. Incharge slab & Beams where ever req. 50 mm pipe dia x 450mm length 0.0 Rupees Zero Only Electrical work Item No. Description of Work Unit Qty. Rate Total Amount Amount in Words
275Point WiringWiring for Light point / fan point/ exhuast point/ call bell point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable in surface / ressed midium class PVC conduit with modular switch, modular plate suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc.. as requiredGroup-A
276Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate siwtch box including connection but excluding modular plate etc.. As required
277Supplying and fixing suitable size of GI box with modular plate and cover infront of surface or in recess including providing and fixing 3 pin 5/6 amp modular socket outlet and 5/6amp modular switch connections etc.. As required
278Supplying and fixing suitable size of GI box with modular plate and cover infront of surface or in recess including providing and fixing 6 pin 5/6 amp & 15/16amp modular socket outlet and 15/16amp modular switch connections etc.. As required
279Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required25mm
280Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required32mm
281Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required40mm
282MAINS : ( not for Point wiring )Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducter single core cable in surface / recessed midium class PVC conduit as required4 X 6 sq.mm. + 2 X 6 sq.mm. earth wire
283Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducter single core cable in surface / recessed midium class PVC conduit as required2 X 6 sq.mm. + 1 X 6 sq.mm. earth wire
284Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducter single core cable in surface / recessed midium class PVC conduit as required2 X 4 sq.mm. + 1 X 4 sq.mm. earth wire
285Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducter single core cable in surface / recessed midium class PVC conduit as required2 X 2.5 sq.mm. + 1 X 2.5 sq.mm. earth wire
286Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conducter single core cable in surface / recessed midium class PVC conduit as required2 X 1.5 sq.mm. + 1 X 1.5 sq.mm. earth wire
287Distribution BoardSupply, Assembling, grouting, leveling Connecting & testing D.B of IP 43 of specified make.Distribution Board-VTPNSupplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
288Distribution Board-TPNSupplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 Way (4+24), Double door
289Distribution Board-SPNSupplying and fixing of following ways single pole and neutral sheet steel MCB distribution board 240V, on surface/recessed, complete with tinned copper busbar, neutral busbar, earthbar, din bar, interconnections powder painted including earthing etc.. as required (but without MCB/ RCCB / isolator) (a) 16 Way, Double door no 1.0 0.0 Rupees Zero Only Rupees (b) 12 Way, Double door no 2.0 0.0 Rupees Zero Only Rupees (c) 8 Way, Double door no 28.0 0.0 Rupees Zero Only Rupees
290MCBSupplying and fixing 5 to 32 amp rating, 240/415V 10KA \\"C\\" curve miniature circuit breaker suitable for inductive load of follwing poles in the existing MCB DB complete with connections, testing and comisioning etc.. As required (a) Single Pole no 239.0 0.0 Rupees Zero Only Rupees (b) Three Pole no 3.0 0.0 Rupees Zero Only Rupees
291Supplying and fixing rating, double pole (single phase and neutral) 240V, residual current circuit breaker having a sensitivity current 30mA in the existing MCB DB complete with connections tecting and comissioning etc.. As required (a) 25 Amp no 54.0 0.0 Rupees Zero Only Rupees (b) 40 Amp no 1.0 0.0 Rupees Zero Only Rupees (c) 40 A FP MCB no 8.0 0.0 Rupees Zero Only Rupees (d) 63 A FP MCB no 1.0 0.0 Rupees Zero Only Rupees
292Providing and fixing following rating and breaking capacity and pole MCCB with Thermomagnetic release and terminal spreaders in existing cubical panel board inclusing drilling holes In cubical panels making connection etc.. As required (a) 125 Amp, 36KA, FP MCCB no 1.0 0.0 Rupees Zero Only Rupees (b) 100 Amp, 36KA, FP MCCB no 1.0 0.0 Rupees Zero Only Rupees
293SITC of Astronomical time switch of following configuration to be mounted in feeder pillars lighting DB's for automatic switching on and off of street lights at sunset and sunrise or twilight (Auto on , auto off, auto modes) with manual overidefacility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required2 output per phase and suitable for single phase supply
294SITC of 25 Amp DP Dinrail Mounted Contactor
295SITC of 40 Amp DP Dinrail Mounted Contactor
296SITC of IP65 Polycarbonate enclosure for FP MCCB
297Supplying and fixing 20A, 240 V, SPN industrial type socket utlet with 2 pole and earth, metal enclosed plug top alongwith 20 A\\"C\\" curve, SP MCB, in sheet steel enclosute, on surface or in recess with chained metal cover for the socket outlet and complete with connection, testing and comissioning etc. as required
298Supplying and fixing 30A, 415 V, TPN industrial type socket utlet with 4 pole and earth, metal enclosed plug top alongwith 30 A\\"C\\" curve, TP MCB, in sheet steel enclosute, on surface or in recess with chained metal cover for the socket outlet and complete with connection, testing and comissioning etc. as required
299Cable TraySupplying and installing following size of perforated hot dipped galvanised iron cable tray (Galvanisation thickness not less than 50microns) with perforation not more than 17.5% in convenient sections joined with connectors, suspended from the ceiling with GI Suspenders including GI bolts and nuts etc.. as required. (a) 100 mm width X 50mm depth X 1.6mm thickness mtr. 100.0 0.0 Rupees Zero Only Rupees (b) 300 mm width X 50mm depth X 1.6mm thickness mtr. 100.0 0.0 Rupees Zero Only Rupees
300Supplying and installing following size of perforated hot dipped galvanised iron cable tray \\"bends\\" (Galvanisation thickness not less than 50microns) with perforation not more than 17.5% in convenient sections joined with connectors, suspended from the ceiling with GI Suspenders including GI bolts and nuts etc.. as required. (a) 100 mm width X 50mm depth X 1.6mm thickness Each 2.0 0.0 Rupees Zero Only Rupees (b) 300 mm width X 50mm depth X 1.6mm thickness Each 2.0 0.0 Rupees Zero Only Rupees
301Supplying and installing following size of perforated hot dipped galvanised iron cable tray \\"Cross members\\" (Galvanisation thickness not less than 50microns) with perforation not more than 17.5% in convenient sections joined with connectors, suspended from the ceiling with GI Suspenders including GI bolts and nuts etc.. as required. (a) 100 mm width X 50mm depth X 1.6mm thickness Each 2.0 0.0 Rupees Zero Only Rupees (b) 300 mm width X 50mm depth X 1.6mm thickness Each 2.0 0.0 Rupees Zero Only Rupees
302Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres
303Construction of brick masonry pulling chamber 450 mm x 450 mm inside clear size and depth up to 0.6 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 450 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect.
304Construction of brick masonry pulling chamber 600 mm x 600 mm inside clear size and depth up to 0.60 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 600 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect.
305Construction of brick masonry pulling chamber 750 mm x 750 mm inside clear size and depth up to 0.75 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 750 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect.
306Construction of brick masonry pulling chamber 1000 mm x 1000 mm inside clear size and depth up to 1.0 meter with 350 mm thick masonry in cement mortar proportion 1:5,cement finish cement plaster in CM proportion of 15 mm thickness from inside with 150 mm thick PCC at bottom with top slab minimum 200 mm thickness in M20 grade with reinforcement. The rate shall be inclusive of providing and fixing frame and 900 mm dia cover of FRC for the Heavy Duty. Rate also inclusive of excavation and back filling & clearing the site by removing debris & Shifting of the debris & making site good As per the Instruction of the Engineer In charge complete in all respect.
307CablesSupplying of XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (a) 150 sq.mm x 3.5c Al. XLPE Arm. Cable mt 55.0 0.0 Rupees Zero Only Rupees (b) 95 sq.mm x 3.5c Al. XLPE Arm. Cable mt 198.0 0.0 Rupees Zero Only Rupees (c) 70 sq.mm x 3.5c Al. XLPE Arm. Cable mt 20.0 0.0 Rupees Zero Only Rupees (d) 50 sq.mm x 3.5c Al. XLPE Arm. Cable mt 20.0 0.0 Rupees Zero Only Rupees (e) 25 sq.mm x 4 c Al. XLPE Arm. Cable mt 451.0 0.0 Rupees Zero Only Rupees (f) 16 sq.mm x 4 c Al. XLPE Arm. Cable mt 160.0 0.0 Rupees Zero Only Rupees (g) 10 sq.mm x 4 c Al. XLPE Arm. Cable mt 1887.0 0.0 Rupees Zero Only Rupees (h) 6 sq.mm x 4 c Cu. XLPE Arm. Cable mt 20.0 0.0 Rupees Zero Only Rupees (i) 4 sq.mm x 4 c Al. XLPE Arm. Cable mt 992.0 0.0 Rupees Zero Only Rupees (j) 6 sq.mm x 3 c Al. XLPE Arm. Cable mt 1556.0 0.0 Rupees Zero Only Rupees
308Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper conductor for 1.1 KV. To be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size cable.2.5 sq.mm x 3 c cu. XLPE Arm. Cable
309Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper conductor for 1.1 KV. To be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size cable.2.5 sq.mm x 4 c cu. XLPE Arm. Cable
310Cable Laying Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV Grade of following size direct in ground including excavation and refilling the trench etc.. As required but excluding sand cushioning and protective covering: (a) Upto 35 Sq.mm. mt 2100.0 0.0 Rupees Zero Only Rupees (b) Above 35 sq.mm. and upto 95 sq.mm. mt 38.0 0.0 Rupees Zero Only Rupees (c) Above 95 sq.mm. and upto 185 sq.mm. mt 55.0 0.0 Rupees Zero Only Rupees
311Cable Laying Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV Grade of following size direct in existing RCC/ Hume/ Metal pipe as required (a) Upto 35 Sq.mm. mt 4413.0 0.0 Rupees Zero Only Rupees (b) Above 35 sq.mm. and upto 95 sq.mm. mt 200.0 0.0 Rupees Zero Only Rupees (c) Above 95 sq.mm. and upto 185 sq.mm. mt 55.0 0.0 Rupees Zero Only Rupees
312Cables TerminationSupplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required: (a) 3½c X 150 sq. mm no 2.0 0.0 Rupees Zero Only Rupees (b) 3½ cX 95 sq.mm. no 14.0 0.0 Rupees Zero Only Rupees (c) 3½c X 70 sq.mm. no 2.0 0.0 Rupees Zero Only Rupees (d) 3½ c X 50 sq.mm. no 2.0 0.0 Rupees Zero Only Rupees (e) 4c X 25 sq.mm. no 8.0 0.0 Rupees Zero Only Rupees (f) 4c X 16 sq.mm. no 8.0 0.0 Rupees Zero Only Rupees (g) 4c X 10 sq.mm. (25mm) no 46.0 0.0 Rupees Zero Only Rupees (h) 6 sq.mm x 4 c Cu. XLPE Arm. Cable no 2.0 0.0 Rupees Zero Only Rupees (i) 4 sq.mm x 4 c Cu. XLPE Arm. Cable no 42.0 0.0 Rupees Zero Only Rupees (j) 6 sq.mm x 3 c Cu. XLPE Arm. Cable no 68.0 0.0 Rupees Zero Only Rupees (k) 4/2.5 sq.mm x 3/4 c Cu. XLPE Arm. Cable no 55.0 0.0 Rupees Zero Only Rupees MV Switchgear & Power Panels Rupees Supply, Unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning main L.T. panel board, fabricated from M.S. sheet & folded channel totally enclosed cubical type compartmentalized. Scope Covers Unloading at Site, Store in Weather Proof Condition, Shift to the Location Basement / GF / FF, Grouting, Installation, Testing & Commissioning complete in all respect & As per the instruction of Architect / Consultant / Engineer Incharge. Scope also covers Co ordination with Panel Manufacturer. Rupees Design, fabrication, assembling, supply, installation , testing of Panels for 415 V, 3 phase, 50 Hz, 4 wire power supply system. Rupees Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical formation, compartmentalized in Form 4b Construction, floor mounted, free standing and shall be dust and vermin proof. 3 mm thick cable gland plate, shall be provided both at the top and the bottom of the panel. Rupees All large panels shall be provided with lifting hooks. Distribution panels shall be fabricated in accordance with the specifications. Rupees Note : Panel vendor has to provide Surge Protection at every stage of the Distribution. Rupees 1) Supporting rigid steel framework. Rupees 2) Cubicle type, 14 gauge CRCA sheet steel enclosed. Rupees 3) Complete with interconnections and distribution bus bars. Rupees 4) Proper bonding to earth. Rupees 5) Painting/lettering on Breakers and distribution boards, the location they serve, providing on each panel its circuit diagram. Rupees 6) Providing cable clamps / supports within distribution boards cable alley. Rupees 7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral link. Rupees 8) All MCB’s shall be of minimum 10 KA breaking capacity. Rupees 9) The breaking capacity of MCCB’s are mentioned panel wise. Rupees 10) All motor feeders MCCBs shall be of motor duty. Rupees 11) Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-7032 of IS-5. Rupees 12) Degree of protection for following type of distribution panel enclosure shall be as per IS:13947-1993.a) IP 52 for indoor panels.b) IP 54 for Service area panels.c) IP 65 for outdoor panels. Rupees 13) All MCCB’s shall be provided with operating mechanism for door interlock & with the roraty handle. Rupees 14) Current density of aluminium shall be 1 sq mm for 0.8 amps for rated current of bus bars and current density of copper shall be 1 sq.mm for 1 amps for rated current of bus bars. Rupees 15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided through out the length of each board. Rupees 16) All measuring instruments (Meters) shall be of digital electronic with LED of approved make and compatible with BAS. Rupees 17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire. Rupees 18) All panels shall have provision of the following:a) IP 55 for outdoor panels.b) Pad locking of MCCB’s handles in “OFF” Position. Rupees 19) Additional set of C.T.s, potential free contacts, connectors, contactors with wiring etc are to be provided for BAS including space required for various transducers in Main Switch Board sections. Only transducers shall be supplied by BAS contractor. Rupees 20) All the C.T.s should be auto short link type. Rupees 21) All the MCCB's should be with rotary handle. Rupees 22) All MCB’s used for protection of resistive and lightly inductive load shall be type “B” characteristic and inductive (motor) load shall be of type “C” characteristic and discharge lamps and UPS etc. shall be of type D characteristic. Rupees 23) All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. Rupees 24) All PTs / control transformer shall be provided with centre tap earth secondary. Rupees 25) If Any descripancy found in SLD & BOQ, it should be brought in the notice of the Client / Consultant, Client / Consultant's decision will be final in case of any descripancy.26) All outdoor panles should be provided with minimum 600mm height fabrication stand with all side 2mm thick M.S. powder coated sheet AND SHOULD BE WITH MARINE GRADE PAINT OR ANY OTHER COATING WHICH IS MARINE GRADE. Rupees 26) G.A. Drawing should be checked & Finalised by consultant before fabrication. Rupees
313SITC of Main LT Panel (TTA as per IEC 61439)Incoming : From CSS250 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-250 / 5 amps CTR digital ammeter with 3 nos 250 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 250 / 5 Amp. CT of 15 VAIncoming : From D.G250 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-250 / 5 amps CTR digital ammeter with 3 nos 250 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 250 / 5 Amp. CT of 15 VAATS250 amps with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos. Bus Bars250 amps FP Al. bus bars with colored heat shrinkable insulated sleeve.Outgoing :160 amps 4 pole MCCB ( 16 KA) : 2 Nos.125 amps 4 pole MCCB ( 16 KA) : 3 Nos.63 amps 4 pole MCCB (16KA) : 5 Nos.40 amps 4 pole MCCB (16KA) : 1 Nos.32 amps 4 pole MCB ( 10 KA ) : 1 Nos.6 to 32 amps 2 pole MCB ( 10 KA) : 4 Nos.Panel should be as per SLD & Specifications Rupees
314SITC of 50KVAR APFCR Panel (TTA as per IEC 61439)Automatic Power Factor Correction (APFC) SystemSupply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitorand reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus barsupports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340Part -1 & 2) APFC Panel shall be in compliance with IS :16636 & CPWD Specifications etc. as per below details. (A) Incomers Suitable capacity MCCB Microprocessor base withO/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED IndicatingLamp set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating. (B) Instruments & Indicationsi) 3-Phase current sensing APFC microprocessor relay/controller , advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100 KVAR & above) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V , THD-I, harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency.iv) Suitable rating control transformer shall be provided for control and indication circuit.v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.vi) Wiring of the control circuit shall be Rupees (i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of NIT.(ii) Capacitor will be MPP self healing type withdischarge resistor, pressure release mechanism.(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415Volts. (iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with Capacitor. (Note: Technical specifications sheet for selection ofthe capacitors combinations shall be provided by theNIT Approving Authority with due consideration ofnumber of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5KVAR, 10 KVAR.....for smooth correction). 50 KVAR Rupees
315SITC of IP65 Food Kiosks and Sitting Area Panel (TTA as per IEC 61439)Incoming :160 amps FP MCCB (36 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-500 / 5 amps CTR digital ammeter with 3 nos 160 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 160 / 5 Amp. CT of 15 VABus Bars160 amps FP Al. bus bars with colored heat shrinkable insulated sleeve.TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 100A FP MCCB as per SLDOutgoing63 amps 4 pole MCB ( 10 KA ) : 2 Nos.40 amps 4 pole MCB ( 10 KA ) : 2 Nos.32 amps 4 pole MCB ( 10 KA ) : 10 Nos.6-32 amps 2 pole MCB ( 10 KA ) : 32 Nos.Panel should be as per SLD & Specifications
316SITC of IP65 Plumbing & Fire Fighting Panel (TTA as per IEC 61439)Incoming :125 amps FP MCCB (16 KA) with following accessories: 1 Setsi. LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's. - 5 nos.ii. 3 Nos. of Digital type 0-500 / 5 amps CTR digital ammeter with 3 nos 125 / 5 amps, 15 VA Class I CT’s.iii. Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be protected by 2 amp TP MCB’s - 1 no.iv) Load Manager of Schneider make PM 5110 with RS 485 connectivity with 3 nos. of Class 1, 125 / 5 Amp. CT of 15 VABus Bars125 amps FP Tinned copper bus bars with colored heat shrinkable insulated sleeve.TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 100A FP MCCB as per SLDOutgoing63 amps 4 pole MCB ( 10 KA ) : 2 Nos.6 to 32 amps 4 pole MCB ( 10 KA ) : 15 Nos.6 to 32 amps 2 pole MCB ( 10 KA ): 2 Nos.Panel should be as per SLD & Specifications
317SITC of IP 65 Section Feeder Pillar (TTA as per IEC 61439)Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning double compartmentalized Street light control panel with IP 65 protection & Enclosure should be powder coated fabricated from 10 Gauge M.S. sheet & folded channel totally enclosed cubical type. with pad lock arrangement. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Architect/ Consultant. All civil work including RCC platform for street light panel should be in scope of Electrical contractor complete in all respect as per detail drawing and directed by engineer in charge. with the 600 mm height MS angle covered stand. The switchboard (panel) shall have provision for future expansion & shall be modular in construction. The bus bars shall be connected with C type clamps without any drilling on the bus bars.SITC of the IP 65 Smart Section feeder panel with space for Smart Energy monitoring system and 2 number of 3 phase Energy meter of Supply Company for the Street Lighting Consisting of followingIncoming : 63 Amp FP MCB R-Y-B-On-Off indicating Lamp with control fuse.Busbar : Set of 63 A. FP tinned copper busbars of EC. grade & adequate capacity, size & insulated with colour tape & should be tined at all joints.Auto/Manual bypass switch with indicating lampMeter : VAF meter with 63/ 5 A Class 1 ct. Outgoing : MCB's Should be of 10 KA.Timer Equivalent to Theben make Astronomical type with the battery back up : 1 nos.63 amp. FP Power Contactor : 1 nos.40 Amp. FP MCB : 1 nos.6 -32 Amp. FP MCB : 16 nos.6 - 32 amp. SP MCB : 4 nos.5 KVAR Capacitor with the 40 amp TP capacitor duty contactor with the 10 minute time delay relay. Rupees
318Light FixtureLuminaries with all electrical accessories & it should be energy efficient, low loss, ortho cyclically wound open construction copper ballast, ignitor & power factor improvement capacitor etc are prewired upto the terminal block & mounted on a removable control gear module for ease of maintenance. All electrical connections of the control gear module with the rest of the luminaire should be click fix & foolproof & require use of no tools. Mounting options should be for both lateral as well as pole top mounting. ALL LIGHT FIXTURE SHOULD BE WITH MARINE GRADE PAINT OR ANY OTHER COATING WHICH IS MARINE GRADE. (a) SITC of Any kind of Light Fixture with Basic Rate of Rs. 2500 no 710.0 0.0 Rupees Zero Only Rupees (b) SITC of Any kind of Light Fixture with Basic Rate of Rs. 5000 no 289.0 0.0 Rupees Zero Only Rupees (c) SITC of Any kind of Light Fixture with Basic Rate of Rs. 10000 no 307.0 0.0 Rupees Zero Only Rupees (d) SITC of Any kind of Light Fixture with Basic Rate of Rs. 15000 no 5.0 0.0 Rupees Zero Only Rupees (e) SITC of Any kind of Light Fixture with Basic Rate of Rs. 20000 no 26.0 0.0 Rupees Zero Only Rupees (f) SITC of Any kind of Light Fixture with Basic Rate of Rs. 30000 no 100.0 0.0 Rupees Zero Only Rupees (g) SITC of Any kind of Light Fixture with Basic Rate of Rs. 40000 no 15.0 0.0 Rupees Zero Only Rupees
319Exhaust Fans :Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
320Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM[A] 305 mm dia 900 RPM
321Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
322Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
323Street Light PoleSupplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below. POLE SHOULD BE WITH MARINE GRADE PAINT OR ANY OTHER COATING WHICH IS MARINE GRADE.4 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness
324Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and arrangement for cable terminations as erected on suitable foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by manufacturer considering site requirement. The length of poles are as below. POLE SHOULD BE WITH MARINE GRADE PAINT OR ANY OTHER COATING WHICH IS MARINE GRADE.6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness
325Supplying and erecting street light pole bracket comprising main B Class GI pipe of 4.2 cm/require outside dia. complete with suitable B Class GI sleeve tubing of approx. 45cms.length and suitable for 76.5mm/80mm or require size pole top having sufficient fastners for fixing the brackets and having suitable rise as per site condition as directed and spread of 2 mtr.with suitable welded stiffener reducer and with lock nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. Suitable for side entry fitting brackets of following nos of arms. POLE BRACKET SHOULD BE WITH MARINE GRADE PAINT OR ANY OTHER COATING WHICH IS MARINE GRADE.Single Arm bracket 1.5 Mtr
326EarthingEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
327Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke and salt as required.
328Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre lonq etc. with charcoal/ coke and salt as required.
329Earth wire/strips :Supply and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection / termination with GI thimble etc.. As required
330Providing and fixing 25 mm X 5 mm copper strip onsurface or in recess for connections etc. as required.
331Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required.1 X 6 sq.mm.
332SITC of Water Tight Junction Box of Hensel make Cat. No. KG9003IN With necessary clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with the Water tight Glands only )
333CCTVSupplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :- 1)Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR SourceInbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night.9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import,export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memoryCard.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,24) System Capability: ONVIF25) VMS: Camera shall support open source VMS26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. Rupees 29) Power Requirement: 12VDC/24VDC/PoE (802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 5MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera. Rupees
334Supplying Installation Testing and Commissioning of 5MP/6 MP IP IR Bullet Camera having following specifications, type of lens and features etc :- 1) Type of Camera: Bullet Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB8) Lens Type & Focus: as given below.9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR SourceInbuilt IR LED's with effective distance upto 50 Mtrsintegrated IR and 30 Mtrs for colour view in night.10) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 11) Wide Dynamic Range: WDR (120dB or more)12) Digital Noise Reduction: DNR (2D/3D) On/Off13) Streaming: Triple streaming, configurable14) Video Streaming & Frame Rates: Triple streaming configurable Main stream: 5MP/6MP @25/30 fps, Sub streams: D1@25/30 fps or better15) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser16) Profile Management: User configuration import,export17) Security: User Authentication, Digital Water Marking18) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 19) Recording Management: Format SD, overwrite, storage management, video to NAS device,20) Edge Analytics: Tripwire, Intrusion, Motion Detection21) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection22) Alarm Support: It should have 1/1 Alarm In/ Out Port23) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A / G.711Mu/AAC/ G.726 audio compreesion 24) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,25) System Capability: ONVIF 26) VMS: Camera shall support open source VMS27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, ,video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 28) Ethernet: 1 RJ 45 10/100 Ethernet port29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.30) Power Requirement: 12VDC/24V DC/PoE (802.3af)/ePoE31) Enclosure: IP67 weather proof, IK1032) Operating Condition: Ambient Temperature:- ()05°C to 50°C, humidity 95% (max)(non-condensing) 33) IR life: 40000 hours or higher34) Video Bit rate: 32 KBPS - 8 MBPS or better35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS MP/6MP IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) outdoor bullet Camera Rupees
335Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3)Signal System: PAL/NTSC 4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,,0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control ,White Balance- Auto, Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR SourceInbuilt IR LED's with effective distance. The camerashould have IR LED’s and cover distance up to 300 meter or above 10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC 15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, videoencryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, FaceDetection 22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS. 23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.1 27) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. Rupees 29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection31) Operating Condition:- Ambient Temperature:- ()05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 5MP IP IR motorized PTZ @25/30fps or bettercamera, Triple streaming , configurable on resolution:-Main stream: 5MP@25/30 fps Sub streams:1080p@25/30 fps, varifocal lens 3.95mm (±5mm) ~ 177.75mm (±5mm) or better with Automatic & manual Focus Adjustment provisions, 45x Optical zoom and 16x Digital zoom with angle of view H:65.7°–1.9°V: 39.4°–1.1°D: 73.1°–2.1, PAN Travel: Pan: 0° ~ 360° endless,Manual Pan: 260° /s, Preset : 300° /s, Tilt Travel: Tilt: -20° ~ 90°, auto flip 180°, Manual Tilt: 120° /s, Preset : 200° /s Rupees
336Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneouslyMulti-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compressions : H.265 or better, H.264, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring,network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playbackof cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode21) It should support Resolution: 32MP; 24MP; 16MP;12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function issupported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive anycombination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm Rupees 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :-- 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and facerecognation 64 Channel Network Video Recorder (NVR) havingdisplay split :- Main screen: 1/4/8/9/16/25/36/64, 2ndscreen: 1/4/8/9/16 Rupees
337Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.10TB (Terabytes)
338Supply, Installation & Commissioning of NVMS workstation/PC with minimum Intel Core i7-6700, 3.4GHz, 8GB RAM, Windows 10 (64 Bit) OS, DVD R/W, Integrated Intel HD graphics 530 and NVIDIA Quadro NVS 315 1 GB PCIE x 16 LP supporting 4 Monitors. The NVMMS shall be complete system for satisfactory surveillance operations with all necessary softwares, licenses, required PC Hardware, Storage, accessories etc., civil, electrical works & peripheral items, as required as per specification in Annexure A at site of work inline with the Engineer in Charge instructions..
339Supply, Installation, Testing And Commissioning of 55\\" HD Monitor for viewing the cameras
340Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE,OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government ofIndia etc. complete as required. 24 port PoE Layer 2 Network Switch with PoESupport of 370W or higher with each copper port supporting 802.3at PoE+ min.
341Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel.
342Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft)
343Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.6U Rack
344Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesivethermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required.
345Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standardscompliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cableshould have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable
346Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH(Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 607931/60794-1-2, ITU-T-REC G.652D and Telecordia GR20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 C to +50 C and Storage Temperature should be – 5 C to +50 C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required6 Core Multi Mode Optical Fiber Cable
347UNINTERRUPTED POWER SUPPLY (UPS) Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design,manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ totaldemand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge.Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltageelectromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS(as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DCbreaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 10KVA Rupees Miscellaneous Rupees
348Supplying rubber matting of following thickness as per IS : 15652/IEC611119mm
349Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required
350Providing printed instruction chart both in English, Hindi and duly framed with front glasses, for treatment of person suffering from Electric shock
351Providing the A0 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
352Providing the A1 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
353Providing the A2 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
354Providing the A3 Color size print of the Final Plan / SLD duly framed out on Glass for Electrical room & BMS Room
355SITC of IP66 Water Tight Junction Box 104mm x 104mm x 70mm With necessary clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with the Water tight IP 66 Polyamide Glands, open Holes should be sealed with the IP65 Grommets only ) J. B. Should be provided with Hensel make Cat. No. WP 0202 G or equivalent. cable connectors to connect suitable for 1.5 - 2.5 sq.mm wires + Earthing wires. including Connectors + IP65 Glands + IP65 Grommets
356SITC of IP66 Water Tight Junction Box 130mm x 130mm x 77mm With necessary clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with the Water tight IP 66 Polyamide Glands, open Holes should be sealed with the IP65 Grommets only ) J. B. Should be provided with Hensel make Cat. No. WP 0606 G or equivalent. cable connectors to connect suitable for 2.5 - 6.0 sq.mm wires + Earthing wires. including Connectors + IP65 Glands + IP65 Grommets
357SITC of IP66 Water Tight Junction Box 130mm x 130mm x 77mm With necessary clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with the Water tight IP 66 Polyamide Glands, open Holes should be sealed with the IP65 Grommets only ) J. B. Should be provided with Hensel make Cat. No. WP 1010 G or equivalent. cable connectors to connect suitable for 4.0 - 10.0 sq.mm wires + Earthing wires. including Connectors + IP65 Glands + IP65 Grommets
358SITC of IP66 Water Tight Junction Box 130mm x 180mm x 77mm With necessary clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with the Water tight IP 66 Polyamide Glands, open Holes should be sealed with the IP65 Grommets only ) J. B. Should be provided with Hensel make cable connectors to connect 1 nos. of 4/10 sq. mm. x 4 core cables+ 4-5 nos. of 4/2.5 sq. mm x 4/3 core wires + Earthing wires. of Hensel make cat. no. KX1010C + Connectors + IP65 Glands + IP65 Grommets
359Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. : (a) 63 mm dia (OD-63 mm & ID-51 mm nominal mt 5000.0 0.0 Rupees Zero Only Rupees (b) 90 mm dia (OD-90 mm & ID-76 mm nominal) mt 1500.0 0.0 Rupees Zero Only Rupees (c) 120 mm dia (OD-120 mm & ID-103 mm nominal) mt 250.0 0.0 Rupees Zero Only Rupees 0.0 Rupees Zero Only Rupees Fire Fighting Work Item No. Description of Work Unit Qty. Rate Amount Amount In Words
360HAND APPLIANCES :- Providing and fixing ABC type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 6.0 kg. I.S.I. Marked.( Make:- KANEX/ CEASE FIRE / SAFEX )
361Providing and fixing Trolley type foam fire extinguishers cap. 50 liters. 50 litres capacity ( Make:- KANEX/ CEASE FIRE / SAFEX )
362Providing and fixing in position Co2 gas type fire extinguishers of 4.5 kg. capacity each.( Make:- KANEX/ CEASE FIRE / SAFEX )
363Providing and fixing Trolley type Co2 gas fire extinguishers cap. 9 liters will be provided for transformer area.( Make:- KANEX/ CEASE FIRE / SAFEX ) 0.0 Rupees Zero Only Rupees

AI Tender Summary

OUR REF NO 56363627
AUTHORITY Government Departments
TENDER VALUE 34.05 Crore
LAST DATE 31-07-2026
Authority
Authority Name Smart City Mission
Work Description Tender for Develoment Of City Center At Agatti, U T Of Lakshadweep
Basic Detail
Tender No F.No.23/SmartCity/2025/298
Bidding Type Tender
Location
City Lakshadweep District
State Lakshadweep
Key Dates
Publish Date 17 Jul 2026
Submission Date 31 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 34.05 Crore
Tender Fee Ref. Documents
EMD 44.05 Lakhs
Exemption Available
Document List
37a3df7f-3728-4377-87a5-a837994fc03d.html
AgattiPresentation.pdf
AgattiTenderDrawingscompressed.pdf
BOQ_3820.xls
NITAgatti.pdf
Tendernotice_1 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
html

37a3df7f-3728-4377-87a5-a837994fc03d.html

pdf

AgattiPresentation.pdf

pdf

AgattiTenderDrawingscompressed.pdf

xls

BOQ_3820.xls

pdf

NITAgatti.pdf

pdf

Tendernotice_1 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders