Tender For Completion Of Incomplete Work For Provision Of Indoor Sports Complex With Allied Work Under Ge (C) Pune
Tender Value
8.50 Crore
Estimated cost
Bid Submission
12 Aug 2026
31 days left
EMD
7.50 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Completion Of Incomplete Work For Provision Of Indoor Sports Complex With Allied Work Under Ge (C) Pune
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part-I to XIV items which are Prepriced by MES, Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Total amount of Sch ‘A’ Part IA (Building/ Structures) |
| 3 | Total amount of Sch ‘A’ Part I B (Building & Structures) |
| 4 | Total amount of Sch ‘A’ Part II (Site clearance,Excavation and Earth Work) |
| 5 | Total amount of Sch ‘A’ Part III ( Internal Water Supply) |
| 6 | Total amount of Sch ‘A’ Part IV (Internal Electric Supply) |
| 7 | Total amount of Sch ‘A’ Part V (Road, Path and Culverts) |
| 8 | Total amount of Sch ‘A’ Part VI (Sewage Disposal) |
| 9 | Total amount of Sch ‘A’ Part VII (Area Drainage) |
| 10 | Total amount of Sch ‘A’ Part VIII (External Water Supply) |
| 11 | Total amount of Sch 'A' Part-IX (External Electric Supply) |
| 12 | Total amount of Sch 'A' Part-X (Compound wall, Fencing and Gate) |
| 13 | Total amount of Sch 'A' Part-XI (Rain Water Harvesting) |
| 14 | Total amount of Sch 'A' Part-XII (Demolition and Dismantling) |
| 15 | Total amount of Sch 'A' Part-XIII Deviation orders partially executed/ not executed by the defaulter contractor ) |
| 16 | Total amount of Sch 'A' Part-XIV (Structural Retrofit Schedule) |
| 17 | SCHEDULE 'A' PART-XV (MISC B/R AND E/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as \\"Rs 0.00\\" under Col 6 signifies this fact only |
| 18 | S&F 3mm thick PVDF coating aluminium composite wall cladding as approved by GE on Facia, column and other decorative faces including Aluminium frame work as approved by Engr-in-Charge complete all as specified and as directed. |
| 19 | S&F 15mm dia bore chromium plated 2 way bib cock with wall flange confirming to CAT No LYR-CHR-38041 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 20 | S&F health faucet with 8mm dia, 1.2 m long flexible tube and wall hook with NRV confirming to CAT No ALD-CHR-577 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 21 | S&F chromium plated toilet paper holder conforming to CAT No CAN 1151 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 22 | S&F 15mm dia bore chromium plated bib cock with wall flange confirming to CAT No LYR-CHR-38037 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 23 | S&F 15mm dia bore chromium plated angular stop cock with wall flange confirming to CAT No LYR-CHR-38053 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 24 | S&F CP shower rose confirming to CAT No OHS 1709 of Jaquar or equivalent in makes listed in Appendix 'C', complete all as specified and as directed |
| 25 | M&L for Shear Connectors by drilling 16mm dia holes up to a depth of 300mm maximum , Clean the hole using air or blower and filled the holes with one or two component styrene free vinylester resin anchor or two components, styrene & cement free epoxy- acrylate fixing and anchoring compound.Make: Bostik RESIFIX-G , Hilti , Sikaor as approved by GE. Note : TMT bars shall be measurment and paid separately under relevant |
| 26 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC roof as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer complete all as specified and as directed by the Engineer-in-Charge. Make :- TP/Chemsol/Bostik/Choksey/Fosroc as approved by GE. |
| 27 | M&L for Cleaning & applying rust remover (Sika rustoff100) in two coats over rusted reinforcement n exc 16mm dia along girth surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns dft with Sika friazinc R or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding, machinery, tools tackles and clearing of debris complete all as specified and as directed by the Engineer-in-Charge. Make : STP/Chemsol/Bostik/Choksey/Fosroc as approved by GE |
| 28 | S&F MS anchor bolt with Nut head of dia 40mm dia and length 1300mm as shown in drg |
| 29 | M&L for de-shuttering of Right Annexe 3.2m Slab any description,size at any height all as specified and directed by Engineer-in-Charge |
| 30 | Dismantling of erected PEB structure of any size,any description at any height all as specified and directed by Engineer-in-Charge |
| 31 | Supply, installation, testing, and commissioning of floor-mounted pop-up socket outlets, flush with finished floor level, comprising 3 modules of 6 Amp sockets, complete in all respects, including all accessories and fixing arrangements, as specified and as directed.The pop-up socket shall be of Legrand make or equivalent, from the approved makes listed in Appendix ‘C’. |
| 32 | Supply, installation, testing, and commissioning of floor-mounted pop-up socket outlets, flush with finished floor level, comprising 4 modules of 16 Amp sockets, complete in all respects with all necessary accessories and fixing arrangements, as specified and as directed.The pop-up socket shall be of Legrand make or equivalent, from the approved makes listed in Appendix ‘C’. |
| 33 | Supply and fix LED tube light fitting, wall-mounted, 18 Watt LED, 6500K (cool white), with opal white polycarbonate diffuser, provided with a high-efficiency integral constant current driver, suitable for 230 Volts AC supply, complete with mounting batten, all internal pre-wiring, and all necessary accessories.The fitting shall include connection with twin-core twisted flexible copper conductor of suitable size from ceiling rose to connector, and shall conform to Bajaj Catalogue No. BLRB DB 118 / BLRB 18W CW LED, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 34 | Supply and fix LED wall-mounted mirror light fitting, 10 Watt LED, with polycarbonate co-extrusion tube housing and engineering plastic end caps, complete luminaire with integral constant current output driver, suitable for standard AC supply.The fitting shall conform to Bajaj Catalogue No. BCLSB 10WH, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 35 | Supply and fix surface-mounted integral round LED downlight, 18 Watt, with powder-coated spun aluminium housing and dome-shaped opal diffuser, complete with in-built driver, suitable for indoor application, complete in all respects as specified and as directed.The luminaire shall conform to Bajaj Catalogue No. BGCML 18W, or equivalent approved make from those listed in Appendix ‘C’. |
| 36 | Supply and fix LED energy-efficient security light fitting, 25 Watt LED, with pressure die-cast aluminium housing, heat-resistant glass cover, and IP-65 protection, suitable for outdoor application.The item shall include 32 mm dia GI pipe, 1.2 m long, medium-grade, complete with two numbers of clamps fixed with suitable size screws, and all necessary mounting accessories.The fitting shall conform to Bajaj Catalogue No. BCLST 25W LED IV2, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 37 | Supply and fix LED energy-efficient flood light fitting, 120 Watt LED luminaire, with pressure die-cast aluminium housing for efficient heat dissipation and anodised aluminium reflector, complete with IP-66 protection and heat-resistant 4.7 mm toughened glass.The fitting shall be provided with in-built 5 kV surge protection and external 10 kV surge protector, suitable for outdoor application.The luminaire shall conform to Bajaj Catalogue No. BJFL 120W LED, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 38 | Supply and fix ceiling fan, 1200 mm sweep, 5-Star BEE rated with BEE mark (after assembly), complete with fan hook/box and connecting up, including electronic fan regulator (stepped type), modular type, 2-module flush mounted, and all required accessories.The item shall include three-core copper flexible cord of 0.5 sq.mm cross-sectional area, of required length, from ceiling rose to porcelain connector block of the fan.The fan shall be of Bajaj make, Catalogue No. KASSEL STAR, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 39 | Supply and fix exhaust fan, 300 mm sweep, 1400 RPM, single-phase, with lightweight white/ivory plastic rust-proof body and blades, complete with self-opening louvers for protection against birds and rainwater.The fan shall be fixed by means of rugged bolts, nuts, and washers in a round opening cut in the wall, including all necessary fixing accessories.The item shall include three-core copper flexible cord of 0.5 sq.mm cross-sectional area, of required length, from ceiling rose to porcelain connector block of the exhaust fan, suitable for operation on 230 V AC, single-phase supply.The exhaust fan shall be of Bajaj make, Catalogue No. 70068 SUPREME PLUS, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 40 | Supply and fix exhaust fan, 380 mm sweep, 1400 RPM, single-phase, with lightweight white/ivory plastic rust-proof body and blades, complete with self-opening louvers for protection against birds and rainwater.The fan shall be fixed by means of rugged bolts, nuts, and washers in a round opening cut in the wall, including all necessary fixing accessories.The item shall include three-core copper flexible cord of 0.5 sq.mm cross-sectional area, of required length, from ceiling rose to porcelain connector block of the exhaust fan, suitable for operation on 230 V AC, single-phase supply.The exhaust fan shall be of Bajaj make, Catalogue No. 70066 SUPREME PLUS, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed. |
| 41 | Supply and fix air circulator wall-mounted fan, 600 mm sweep, 1400 RPM, single-phase, 200 W, with air delivery capacity of 250 CMM, 3-speed control, complete with all necessary mounting brackets, screws, and accessories.The fan shall be of Bajaj Catalogue No. 250528 SUPREME PLUS, or equivalent approved make from those listed in Appendix ‘C’, complete in all respects as specified and as directed |
| 42 | M&L for submain wiring with 4 single-core FRLS PVC insulated unsheathed multi-stranded flexible copper conductors, 1100 V grade, 10.0 sq.mm, drawn through concealed PVC conduit (heavy grade).The installation shall include 1 single-core 10.0 sq.mm 1100 V grade FRLS PVC insulated unsheathed multi-stranded flexible copper conductor as a continuous earth wire, complete with all necessary accessories, connections, and termination as required, in accordance with standard practice and as directed. |
| 43 | M&L for submain wiring with 2 single-core FRLS PVC insulated unsheathed multi-stranded flexible copper conductors, 1100 V grade, 6.0 sq.mm, drawn through concealed heavy-grade PVC conduit.The installation shall include 1 single-core 6.0 sq.mm 1100 V grade FRLS PVC insulated unsheathed multi-stranded flexible copper conductor as a continuous earth wire, complete with all necessary accessories, connections, and termination, in accordance with standard practice and as directed |
| 44 | M&L for submain wiring with 2 single-core FRLS PVC insulated unsheathed multi-stranded flexible copper conductors, 1100 V grade, 4.0 sq.mm, drawn through concealed heavy-grade PVC conduit.The installation shall include 1 single-core 4.0 sq.mm 1100 V grade FRLS PVC insulated unsheathed multi-stranded flexible copper conductor as a continuous earth wire, complete with all necessary accessories, connections, and termination, in accordance with standard practice and as directed. |
| 45 | M&L for submain wiring with 2 single-core FRLS PVC insulated unsheathed multi-stranded flexible copper conductors, 1100 V grade, 2.5 sq.mm, drawn through concealed heavy-grade PVC conduit.The installation shall include 1 single-core 2.5 sq.mm 1100 V grade FRLS PVC insulated unsheathed multi-stranded flexible copper conductor as a continuous earth wire, complete with all necessary accessories, connections, and terminations, in accordance with standard practice and as directed. |
| 46 | M&L for submain wiring with 2 single-core FRLS PVC insulated unsheathed multi-stranded flexible copper conductors, 1100 V grade, 2.5 sq.mm, drawn through surface-mounted heavy-grade PVC conduit.The installation shall include 1 single-core 2.5 sq.mm 1100 V grade FRLS PVC insulated unsheathed multi-stranded flexible copper conductor as a continuous earth wire, complete with all necessary accessories, connections, and terminations, in accordance with standard practice and as directed |
| 47 | M&L for Vertical 6-way TPN double-door distribution board, recess-mounted or wall-mounted, with MCCBs as incomer: 3-pole V-Tec MCCB, 125 A rating, 16 kA breaking capacity.Outgoing feeders shall be MCBs, SP/TP, factory pre-fitted with all necessary accessories including cost of MCCB and complete with metal enclosure, DIN rail, neutral and earth busbars, earthing arrangement, labeling, and connections, as specified and as directed. |
| 48 | Supply and fix MCB, single pole with neutral, 240 Volts, 6 Amps to 32 Amps, 10 kA breaking capacity, complete with all necessary accessories, enclosure, connections, and termination, as specified and directed. |
| 49 | Supply and fix MCB, single pole with neutral, 240 Volts, 32 Amps, 10 kA breaking capacity, complete with all necessary accessories, enclosure, connections, and termination, as specified and directed. |
| 50 | Supply and fix MCB, four-pole (TPN), 415 Volts, 63 Amps, 10 kA breaking capacity, complete with all necessary accessories, enclosure, connections, and terminations, as specified and directed |
| 51 | Supply and fix foot valve, gunmetal assembly, complete with suitable check nut and other accessories, of 25 mm dia, conforming to IS 4038, complete in all respects as specified and as directed. |
| 52 | Supply and fix non-return valve, 40 mm dia, brass, heavy-duty, ISI marked, complete with all necessary fittings and accessories, as specified and as directed. |
| 53 | Supply, install, test, and commission a self-priming centrifugal pump set (monoblock), including base frame as per OEM specifications. The pump shall be electric-driven, single-phase, 230 Volts, with a discharge of 1.25 LPS at a head of 15 m, driven by a suitable 0.5–1 HP single-phase motor (confirm exact rating as per design).The installation shall include all necessary accessories, a suitable MS weatherproof shelter, and a single-phase starter. The pump set shall be of make as mentioned in Appendix ‘C’, complete in all respects as specified and as directed. |
| 54 | Cutting the existing 100 mm dia CI line and providing tapping connection to 40 mm dia GI pipe, including Fixing 100 × 100 × 80 mm CI tee, with one end flanged and one end spigot tail piece at both ends.40 mm dia GI pipe connection using threaded flange suitable for fixing with 80 mm flange, including gaskets, bolts, nuts, and all necessary accessories.Excavation and backfilling, and supplying and fixing all other required CI and GI fittings for proper connection and alignment complete in all respects as specified and as directed. |
| 55 | Supply, lay, and test XLPE insulated, screened, PVC-bedded, galvanised steel strip armored (RM) electric power cable, heavy-duty with aluminium conductor, 22 kV grade, earthed, 3-core, 95 sq.mm cross-sectional area, laid in trenches, ducts, along poles, or along transformer routes as required.The work shall include all necessary accessories, terminations, joints, and connections, complete in all respects as specified and as directed. |
| 56 | Supply and fix HT cable termination box, suitable for 22 kV (earthed) grade cable, for 3-core XLPE armoured aluminium conductor cable, 95 sq.mm, for outdoor termination, heat-shrink type.The termination shall include all jointing materials, accessories, and necessary fittings, suitable for proper connection of the 3-core 95 sq.mm XLPE armoured cable, complete in all respects as specified and as directed. |
| 57 | Supply, install, test, and commission plinth-mounted step-down outdoor type distribution transformer, HT 22 kV, 3-phase, LT 433 V, 4-wire, 100 kVA Level-I as per latest BIS code including amendments, copper-wound, oil-immersed, naturally cooled with external cooling tubes, core type, delta connected on primary (HV) side and star connected on secondary (LV) side with neutral brought out on LV side, in accordance with vector symbol DYN-11 (Vector group: Dyn-11, vector grounded).The transformer shall have off-load hand-operated tap changer on the primary side with tappings in equal steps of 2.5% from +5% to -7.5%, for LT voltage correction on the secondary side.The transformer shall include all standard accessories and fittings, mainly comprising:Primary (HT) side – 3 nos. porcelain bushings with brass/gunmetal rods, complete with nuts and washers.Secondary (LT) side – 1 cable box with 4 nos. porcelain bushings with GM rods, complete with GM nuts and washers, and 1 cable gland suitable for outgoing 95 sq.mm, 3-core, LT PVC-sheathed armored cable.Oil conservator – filter type, with drain valve and oil level indicator. Dehydrating breather – with first fill of dehydrating agent. Explosive vent. Thermometer pocket on tank cover.Dial-type thermometer – 100 mm dia, vapor pressure type, range 0–120°C, with temperature pointer and maximum temperature indicator Complete in all respects, as per OEM specifications, IS standards, and as directed. |
| 58 | Supply, installation, testing, and commissioning of weather-, dust-, and vermin-proof LT distribution panel board, factory-made, outdoor type, of suitable size to accommodate the following accessories, depth not less than 500 mm, IP-54 rated, prewired and fabricated with 3.15 mm thick CRCA sheet, epoxy powder-coated, double-door with aprons, mounted on MS angle iron frame 50 × 50 × 6 mm, welded in shape with two coats of synthetic enamel paint over red oxide primer. |
| 59 | Installation and civil works:Grouting in PCC 1:3:6 (C-1) with 20 mm graded coarse aggregates, legs 50 cm grouted in ground, top of PCC at 40 cm above ground.Panel complete with all connection cables and terminations, as specified and directed.Accessories and components:Bus Bars:Aluminium bus bar, 300 Amps – 03 Nos for phases, and 01 No for neutral, duly colour-sleeved and mounted on epoxy insulators – 01 set.Incoming Protection:MCCB, 200 Amps, FP, 415 V, 50 Hz, ICU 35 kA, thermally adjustable between 70–100% – 01 No.Outgoing Protection:MCCB, 63 Amps, TP, 415 V, 50 Hz, ICU 25 kA, thermally adjustable between 70–100% – 04 Nos.MCB, 32 Amps, FP, 415 V, 50 Hz, 10 kA – 01 No.Meters and Indicators:Digital LED Ammeter, 3-phase, 0–500 A, Class 1.0, with suitable CTs & selector switch – 01 No.Digital LED Voltmeter, 3-phase, 0–500 V, Class 1.0, with suitable CTs & selector switch – 01 No.LED-type indicator lamp set (R, Y, B) – 01 set.Note: Panel shall be manufactured by a reputed manufacturer in possession of a valid type test certificate (CPRI), not older than 10 years. |
| 60 | Supply, installation, testing, and commissioning of cubical type outdoor APFC panel, 4-stage (5+5+5+5) 20 kVAR rating, complete with:Standard power contactors for staged operation,Heavy-duty gas-filled capacitors,63 A, 25 kA, 4-pole MCCB as incomer, and all suitable standard control elements.Construction and fabrication:Factory-made, outdoor type, fabricated from 3 mm thick CRCA sheet, weatherproof, powder-coated, IP-54 rated,Mounted on MS angle iron frame, and fixed on suitable PCC plinth (PCC plinth measured and paid separately) Complete in all respects, as specified and as directed. |
| 61 | M&L for laying of RCC pipes of dia 150mm, class NP 2 with one caller per length of pipe, 2 Nos half round (for bottom and top) and before laying, excavated area shall be levelled all as specified and as directed. |
| 62 | Supply, install, and erect steel tubular swaged welded poles (swan-neck type), in true vertical position, complete with MS base plate, 6 mm thick, 300 × 300 mm,Finial, taper plug, pole cap,Bolts, nuts, washers, and screws,Pole made of ERW MS tubing conforming to IS 2713 (Part II), 1980, Type 410 SP-31, 9 meters long.One coat of red oxide primer and two coats of aluminium paint for exposed surfaces andTwo coats of black bituminous paint for portion embedded in concrete,Three black/red bands at lower portion of pole at 300 mm spacing,Pole number painted with black paint at suitable height.Complete in all respects, as specified and as directed. |
| 63 | Dismantling of gang-operated air break switch, 22 kV, triple-pole, horizontal/vertical mounted, including insulators and operating mechanism, and refixing at same or any other location, including all connections and necessary accessories, complete as specified and directed. |
| 64 | Dismantling of DO fuse, 22 kV, triple-pole, including insulators, and refixing at same or any other location, including all connections and necessary accessories, complete as specified and directed. |
| 65 | S & F HT 22 KV insulators PIN type, polymer type including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut of standard size complete all as specified and directed |
| 66 | S & F HT 22 KV insulators DISC type,· porcelain, vitreous white/ brown/ green insulator or polymer type including cast iron stud. Gl bolt, nuts, washers clamps, etc. suitable for fixing cin cross arms complete all as specified |
| 67 | Supply and install HT 22 kV outdoor-type gang-operated air break switch, triple-pole, with 3-insulator double stalk type, suitable for horizontal or vertical mounting, complete with all accessories including Mounting channels, bolts, nuts, washers,GI operating rod of suitable length,Locking arrangement with Godrej 7-lever lock (Navtal) and 3 keys, Rated up to 200 Amps, including all necessary connections and terminations, complete in all respects as specified and directed. |
| 68 | Supply and install drop-out fuse unit, expulsion type, outdoor, single-pole, rated 200 Amps, mounted on two insulators fixed to MS channels complete with Bolts, nuts, washers, Synthetic-bonded fuse carrying tube, HT fuse elements of 25 A capacity, suitable for HT 22 kV working voltage,Including all necessary connections and accessories, complete in all respects as specified and directed. |
| 69 | Supply and fix lightning arrester, non-linear type, complete with mounting accessories, fixed on cross-arms of pole and connected with aluminium conductor using all necessary fittings, forming a transmission-class earthing system, with Discharge capacity: 10 kA, Suitable for 22 kV grade working voltage,complete in all respects as specified and directed. |
| 70 | Supply and fix aluminium bus bar, for 2/4 pole structure, made of aluminium tube, 32 mm outer dia, 6 mm thick, suitable for 22 kV, complete with:All suitable joints, fittings, and couplings,Stainless steel nuts, bolts, washers,Insulation with colour sleeves as per standard colour code,complete in all respects as specified and directed. |
| 71 | Supply and fix LED street light fittings, 30 W, IP-66, with Pressure die-cast aluminium housing,Heat-resistant toughened glass,Optimized optics for uniform light distribution,Complete with connecting flexible copper conductor wires – 2 × 2.5 sq.mm for phase and neutral, 1 × 2.5 sq.mm for earth, PVC insulated,As per Bajaj Cat. No. BCLST 30W LED or equivalent.Complete in all respects as specified and directed |
| 72 | Supply, install, connect, test, and commission storage-type water cooler, 80 Litres capacity, with cooling capacity 40 L/hr, using eco-friendly refrigerant gas R-134a, including:Extending drain outlet pipe to nearest drain system,Complete with all necessary accessories, connections, and commissioning Complete in all respects as specified and directed.Make: Blue Star / Usha Nolta |
| 73 | M&L for earthing system, complete with Galvanised steel earth plate electrode, 600 × 600 × 6.3 mm thick, buried vertically in earth pit not less than 2.25 m deep, with top edge of plate at least 1.5 m below ground level,connected to galvanised steel earthing wire, 4 mm dia, using bolts, nuts, checknuts, and washers,GI protection pipe, 15 mm dia, medium grade, for protection of the earth strip, length up to 7.5 m,provision of mixture of charcoal dust & common salt packed 150 mm all around the earth plate,PCC 1:2:4 type B-1 earth pit, with MS angle iron frame, cast iron cover with locking arrangement,GI 20 mm dia medium grade pipe with MS funnel and wire mesh for watering arrangement,Earthing connection to main electrical switchboard (inside building), with GI protection pipe buried under floor/plinth, fixed on walls, or concealed in walls as required,Necessary excavation and earthwork in any strata, and testing of earth pit,complete in all respects as specified, shown on Electrical Plate No. 3 of MES SSR-2009 Part-1, and as directed. |
| 74 | M&L Earthing with galvanised steel earth plate electrode, complete with Earth plate: 600 × 600 × 6.3 mm thick, buried vertically, with earth pit not less than 2.25 m deep and top edge at least 1.5 m below ground level,Connection: Galvanised iron strip 32 × 6 mm, fixed with bolts, nuts, checknuts, and washers,Protection: GI pipe 40 mm dia, medium grade, covering earth strip for up to 7.5 m,Earth pit fill: Mixture of charcoal dust and common salt, 150 mm all around the earth plate,Earth pit structure: PCC 1:2:4, type B-1, with MS angle iron frame and cast iron cover with locking arrangement,Watering arrangement: GI 20 mm dia medium grade pipe, MS funnel with wire mesh,Connections: To main electrical switchboard inside building, GI pipe buried under floors/plinths, fixed on walls, or concealed in walls as required,Excavation, earthwork in any strata, and testing included,As shown on Electrical Plate No. 3, MES SSR-2009 Part-1,complete in all respects as specified and directed. |
| 75 | Supply, laying, testing, and commissioning of underground LT cables, 1100 V grade, XLPE insulated, screened, PVC sheathed, galvanised steel strip or wire armoured, with multi-stranded aluminium conductor, ISI marked, heavy duty, including:Cable glands, cable lugs, and all necessary jointing/connecting materials, Connection to LT panel/MCC in building,Laying in trenches, ducts, under plinth floors, passing through pipes, or fixed on walls,Material and labour for complete installation,complete in all respects as specified and directed, for the following sizes: |
| 76 | 95 sqmm x 3.5 core |
| 77 | 35 sqmm x 3.5 core |
| 78 | 25 sqmm x 4 core |
| 79 | 16 sqmm x 4 core |
| 80 | 10 sqmm x 4 core |
| 81 | 10 sqmm x 2 core |
| 82 | Total amount of Sch 'A' Part-XIII (Schedule of Credit for the defaulter contractor’s materials, tools and plants lying at site) Note:(i) Contractor shall quote the percentage addition over lumpsum price of credit for material, sheds/store and T&P inserted by MES and carry forward the corresponding amount. However the quoted percentage shall not be less than NIL percent (i.e. shall not be on minus side). In case contractor’s quoted percentage is less than 0% (zero percent) it shall be restricted to 0% (zero percent) & total amount accordingly be corrected. The contractor shall take this aspect in account and nothing extra whatsoever shall be admissible on this account. (ii) This schedule of credit amount will be deducted from the contract sum to arrive quoted contract sum. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 31 daysAug 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 38 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender