Tender For Repair/ Maintenance Incl Replacement Of Street Lights, Perimeter Security Lights, Lt Switch Gears, Oh Lt Conductors, Lt Panels, Ug Cable, Electric Geyser, Ceiling Fan/ Exhaust Fan/ Wall Mounted Fans, Sub Main Wiring, Point Wiring, Switch S
Tender Overview
Project Description
Tender for Repair/ Maintenance Incl Replacement Of Street Lights, Perimeter Security Lights, Lt Switch Gears, Oh Lt Conductors, Lt Panels, Ug Cable, Electric Geyser, Ceiling Fan/ Exhaust Fan/ Wall Mounted Fans, Sub Main Wiring, Point Wiring, Switch Socket, Light Fitting At Various Location At Jamshedpur Under Ge Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully exising unserviceable copper/aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed. |
| 2 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit suitable size including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSHH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (Note- Modular cover plate and base plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before. |
| 3 | (a) One light point controlled by one, one way switch 5 Amps |
| 4 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 5 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 6 | (d) One bell point controlled by one, bell switch 5 Amps |
| 7 | (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 8 | Description all as per item No 2 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. |
| 9 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes 1.6 mm thick, 60 mm deep with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-(Contractor should make good even distributed wall/surface as before.) |
| 10 | (a) One light point controlled by one, one way switch 5 Amps |
| 11 | (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 12 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. |
| 13 | (d) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 14 | Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 15 | S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 16 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 17 | S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp (set of 3 switches) , including junction box complete all as specified. JAQUAR Cat Part No SWG-GRY-GL16A3G01 , Havells AHLPLCGV03, Legrand- AC21312MT |
| 18 | S & F for Modular Switch Socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp including junction box complete all as specified. JAQUAR Cat Part No SKG-GRY-GL16ASC1GS1, Havells ACGPTOFV03, Schneider E8315_16_DG |
| 19 | S & F ceiling fan regulator rotary type heavy duty suitable to work on 230 volts AC supply including junction box and removal of old unserviceable one complete all as specified. JAQUAR Cat Part No SWG-GRY-GL1ARFSS, Havells ACYRFHG008, Legrand 573462 |
| 20 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 21 | S & F for Modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 22 | S & F ceiling fan regulator socketed, step type, 1 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 23 | S & F ceiling fan regulator socketed, step type, 2 Module heavy duty suitable to work on 230 volts AC supply including removal of old unserviceable one complete all as specified. |
| 24 | S & F for Bell push modular 6 Amps single module complete all as specified. |
| 25 | Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 26 | S & F for Lamp holder, PVC body suitable for batten fitting completes all as specified. |
| 27 | S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified |
| 28 | S & F for Switch piano flush type, single pole, one way, and 6 Amp complete all as specified. |
| 29 | S & F for Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, piano flush type complete all as specified. |
| 30 | S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked |
| 31 | S&F switch socket combination 2 in 1, 3 pin, 15 amp multipurpose, flush type, all as specified and as directed |
| 32 | S & F for wall mounted LED tube light fitting 1x 22 W, 220V, 4000K batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 33 | S & F for LED 10 watts batten with decorative end caps complete all as specified and as directed. |
| 34 | S & F for Highly efficient LED Bulbs, 10 W, of make Bajaj, Havells, HPL complete all as specified and directed |
| 35 | S & F for sheet metal enclosure MCB DB TPN 4 way Vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 36 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 37 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 38 | S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 Amps with extended terminals complete all as specified. |
| 39 | S & F for MCB tripple pole and neutral rated capacity 63 Amps, 415 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 40 | S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 41 | S & F for MCB Single pole and neutral rated capacity 40-63 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 42 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 volts breaking capacity 10 KA including removal of old unserviceable one complete all as specified and as directed. |
| 43 | Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed. |
| 44 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified. |
| 45 | S & F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. |
| 46 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 47 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 48 | Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed. |
| 49 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size concealed in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed including taking down old Unserviceable. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 50 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed including taking down old Unserviceable. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 51 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4.0 Sqmm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed including taking down old Unserviceable. Note:- Two runs of 4.0 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 52 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed including taking down old Unserviceable. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit Please Enable Macros to View BoQ information |
| 53 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into PVC non metallic rigid heavy duty PVC casing caping of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed including taking down old Unserviceable. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender