Housing Urban and Rular Development Government Departments Closing in 4 days TDR #56363215

Tender For Necessary Repairing And Renovation Of Go-Down, Barrack, Canteen & Toilet Block At Hrbc Bhawan To Accommodate Office Of The Enquiry Commission At Munshi Prem Chand Sarani, Kolkata 700021 During The Year 2026-2027------Electrical Installatio

Issued by Government Departments · Kolkata, West Bengal
Tender Value
26.90 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
4 days left
EMD
53806
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Necessary Repairing And Renovation Of Go-Down, Barrack, Canteen & Toilet Block At Hrbc Bhawan To Accommodate Office Of The Enquiry Commission At Munshi Prem Chand Sarani, Kolkata 700021 During The Year 2026-2027------Electrical Installation Work

BOQ

Name of Work:- Necessary repairing and renovation of Go-down, Barrack, Canteen & toilet block at HRBC Bhawan to accommodate office of the Enquiry Commission at Munshi Prem Chand Sarani, Kolkata 700021 during the year 2026-2027------Electrical Installation Work
Sl. No. Item Description
1Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-11/15]
28 way Up to 160A Make:-Legrand Enclosure (607914) [D-11/15]
3Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14]
4a) 6 Way Enclosure [Make: Legrand Enclosure (607716) or equivalent model of Siemens/Crabtree/L&T as approved by E.I.C]
5Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
6a) 2+10 way Make:-Legrand Enclosure (607711) [D-9/13]
7Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6]
8(a)63 A FP Make:-Legrand [D-5/6]
9(b)40A FP Make:-Legrand [D-5/6]
10Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-6/7]
11(a) 6-32 Amps SP MCB [D-6/7]
12Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment [D-12/16]
13a) 6 way [D-12/16]
14Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
15(a)160 A FP MCCB (Make Legrand/L&T/ Siemens as approved by E.I.C) [D-8/10]
16Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection []
1763 A TP Make:-Legrand [D-6/7]
18Supplying and fixing double door horizental sheet steel (16SWG), powder coated cable end box for TPN DB vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment []
198 way [D-12/16]
20Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] [E-25/5]
21Average run 12 mtr [E-25/5(g)]
22b) On Board [E-24/3(a)]
23Supplying and fixing PVC 25x10mm casing-capping [Precision Make] onwall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works[E-13/10)]
24Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works
2519 mm dia 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire[E-2/3(b))]
26Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1]
27i) 3 x 22/0.3 (1.5 sqmm) [E-9/1(b)]
28ii) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)] [Computer Point and Power Point]
29iii) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] [1.5Tr. And 2 Tr. Ac point]
30iv) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC[E-9/1(y)] [PDB to SPN DB]
31v)4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E-9/1(d1)]
32vi)4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9/1(g1)]
33Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7]
34a) 20mm size [E-16/7(a)]
35b) 25mm size [E-16/7(b)]
36Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-5/9]
37i) 1.5 sqmm
38ii) 2.5sqmm [F-5/9(i)]
39iii) 4 sqmm [F-5/9(ii)]
40iv) 6 sqmm [F-5/9(iii)]
41v)10sqmm [F-5/9(iv)]
42vi)16sqmm [F-5/9(v)]
43Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1]
44i) 2 Row 18 Module [E-17/1(f)]
45ii) 4 Module [E-17/1(a)]
46iii) 6 Module [E-17/1(b)]
47Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
48Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works [E-17/2]
492 Module [E-17/2(a)]
50Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)]
51Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)]
52Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)]
53Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
54Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/17]
55Supply & Fixing 240 V, 25A Modular switch type SP MCB (C-Curve) (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(E-19/219(a))
56Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [D-13/20(a)]
57Supply & Fixing GI Sheet (20 SWG) metal Cowl with MS flat iron frame & GI Wire mesh on wall with necessary bolts & nuts (6mm dia x 62mm long).
5830 cm Exhaust fan (12\\") [D-14/33]
59Supply & fixing of Indicator for existing modular box
60Supply & fixing of Blank Plate for existing modular box
61Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 . Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K,
62Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: System lumen efficacy ≥ 110 lm/Watt [Make:-Signify/LT/Wipro]
63a) 18 - 20 Watt
64Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) 2'x2' with powder-coated pressure Die-cast Aluminium/CRCA sheet body with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K/ 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR,
65PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy shall be as below:System lumen efficacy shall be as below: System lumen efficacy ≥ 135 lm/Watt [Make:-Signify/LT/Wipro]
66a) 33 - 36 Watt
67\\"Supplying and delivery of LED Industrial Batten light made of CRCA SheetBody (Thickness≥0.50mm) andconstruction as perrelevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminiumend-cap)voltageAC140-270Volt,freq50/60hz, Operating temp range 0o to 40oC,internal surge protection of 2.5 KV(internal) with Short& Open circuit protection,THD< 10%,P. F.≥0.9, IP20, CRI>80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate(T.C.). Manufactures Word Mark / NameEngraved / Embossing / Screenprintingonhousing,withMinimum5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Labas per BIS shall be submitted. (Systemlumenefficacy≥115lm/Watt) \\" (Make: Signify / Wipro / LT).
68Twin fittings along with S/F of 2 no. 18-20 W LED lamps as per specification
691.3 Supply & delivery of 230 V, 50 Hz, single phase, 58 watts, 56\\" (1400 mm) Sweep, speed 300 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 250 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make:- Crompton Greaves/EPC/Orient/ Havells ]
70Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. [Make:- Crompton Greaves/EPC/Orient]
71Supplying and delivery of following size Un-Armoured cables XLPE insulated are designed for 1.1 kV Stranded copper conductor and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make:-Gloster/Polycab/Havells/RR Kable]i) 3 core 4 sqmm(from OLP starter to single phase A.C outdoor Connection)
72Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make:-Gloster/Polycab/Havells/RR Kable]
734 core 95 sqmm
74Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy. mending good damages and painting [F-1/2(e)]
75Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : [F-4/7]
76upto 4 core 95 sqmm [F-4/7(c)]
77Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : [F-5/8(b)]
783½ core 95 sqmm cable [F-5/8(b)(xviii)]
79Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the groundlevel as below:By ISI-Medium GI pipe
80Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc.
81Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
82Extra for treatment of soil by using salt & charcoal or coke for plate electrode
83Excavation of soil for installation of Earth Electrode and filling & ramming.
84(a) For Soft Soil
85Supply and delivery MS down rod (14SWG) for AC ceiling fan and Tube light including measurement and cutting in proper size with necessary hole making cuutting filling and polishing & painting the rod complete in all respect as per requirement and making proper clamping arrangement as per instruction of EIC.
86Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
87Supply and fixing of 10 W LED Bathroom Wall Light, having luminoius efficacy of 100lm/W a [Philips/LT/ Wipro or manufacturer with own NABL accredited Lab with valid Test certificate as approved by E.I.C] (Make: Signify / Wipro / LT)
88Disconnection & dismantling existing old Electrical installation, Split AC machine ,Switch-board, wiring, Electrical fitting/fixtures etc with owns tools & takles incl. mending good damages as per GS and clearing/removing and shiftng from the site at HRBC Bhawan to HRBC store
89Add. G.S.T.@ 18% on total of item
90Add. LWC.@ 1% on total of item Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56363215
AUTHORITY Government Departments
TENDER VALUE 26.90 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Necessary Repairing And Renovation Of Go-Down, Barrack, Canteen & Toilet Block At Hrbc Bhawan To Accommodate Office Of The Enquiry Commission At Munshi Prem Chand Sarani, Kolkata 700021 During The Year 2026-2027------Electrical Installation Work
Basic Detail
Tender No WBPWD/EE-WKED/NIT-36/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 08 Jul 2026
Submission Date 27 Jul 2026
Open Date 29 Jul 2026
Finance
Tender Value 26.90 Lakhs
Tender Fee Ref. Documents
EMD 53806
Exemption Not Available
Document List
4e3d09ac-6471-4d6e-9000-141fcbe0d284.html
BOQ_5086055.xls
Tendernotice_1 (15).pdf
WBF-2911.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

4e3d09ac-6471-4d6e-9000-141fcbe0d284.html

xls

BOQ_5086055.xls

pdf

Tendernotice_1 (15).pdf

pdf

WBF-2911.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders