Tender for Attending Providing electrical installation & Fans For 2Nd Floor At Tnt Complex, Chennai.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required |
| 4 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 2 x 1.5 sq. mm |
| 6 | 3 x 1.5 sq. mm |
| 7 | 6 x 1.5 sq. mm |
| 8 | 3 x 2.5 sq. mm |
| 9 | 6 x 2.5 sq. mm |
| 10 | 9 x 2.5 sq. mm |
| 11 | 3 x 4 sq. mm |
| 12 | 6 x 4 sq. mm |
| 13 | 3 x 6 sq. mm |
| 14 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 15 | 1 Pair |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 32 mm |
| 18 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 19 | 5/6 A switch |
| 20 | 3 pin 5/6 A socket outlet |
| 21 | 15/16 A Switch |
| 22 | 6 pin 15/16 A socket outlet |
| 23 | Telephone socket outlet |
| 24 | RJ 45 Socket Cat-6 UTP with shutter |
| 25 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 26 | Supplying and fixing following module, GI box on surface / recess for fixing modular base & cover plate etc. as required |
| 27 | 1 or 2 Module |
| 28 | 3 Module |
| 29 | 6 Module |
| 30 | Supplying and fixing following modular base & cover plate on existing modular metal boxes etc. as required. |
| 31 | 1 or 2 Module |
| 32 | 3 Module |
| 33 | 6 Module |
| 34 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 35 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 36 | Supplying and fixing of 400 mm sweep wall mounting fan complete with testing and commissioning etc. as required. (Make: Crompton or SS make) |
| 37 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 38 | 8 way (4 + 24), Double door |
| 39 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/Isolator) |
| 40 | 8 way (4 + 24), Double door |
| 41 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Light DB) |
| 42 | 12 way , Double door |
| 43 | Supplying and fixing of 225 mm Exhaust fan of 1400 rpm in the existing opening i/c making connections with copper conductor cable complete with testing and commissioning etc. as required. (Make : Crompton / similar superior) |
| 44 | Supply and fixing of 200 mm Exhaust fan of 1300 rpm with dust protection shutters, in the existing opening i/c making connections complete with testing and commissioning etc. as required. (Make: Crompton / Similar Superior) |
| 45 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 46 | Single pole |
| 47 | Triple pole |
| 48 | Triple pole and neutral |
| 49 | Supplying and fixing Triple Pole 63 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 50 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. |
| 51 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 52 | Supplying and fixing 4 way sheet steel enclosure on surface/ recess with provision for mounting FP MCB etc. as required. |
| 53 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 54 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of following size on surface of wall/cable tray complete as required. |
| 55 | 4 X 25 Sqmm |
| 56 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 57 | 4 X 25 Sqmm |
| 58 | Supplying and fixing of 36W, 2'x2' LED surface mounting fitting in the existing ceiling i/c connections with copper conductor cable complete with testing and commissoining etc. as reqd. (Make: Philips / Crompton / Similar superior) |
| 59 | Supplying and fixing of 36W, 2'x2' LED recess mounting fitting in the existing false ceiling i/c providing supporting chains, connections with copper conductor cable complete with testing and commissoining etc. as reqd. (Make: Philips /Crompton / Similar superior) |
| 60 | Supplying and fixing of following type LED downlighter in the existing false ceiling i/c connections with copper conductor cable complete with testing and commissioning etc. as reqd. |
| 61 | 18 Watts LED type Recessed Panel light (Make: Crompton, Star Slim / Similar superior) |
| 62 | Supplying and fixing 20 watts 4ft LED batten on surface of wall / ceiling i/c making connections with copper conductor cable complete with testing and commissioning etc. as required (Make: Philips or SS make) |
| 63 | Supplying of adaptor / Junction boxes fabricated out of 16 SWG MS sheeet including making cutting, welding, powder coating and fixing on surface or in recess including cutting the wall / floor and making good the same in case of recessed system etc. as required. |
| 64 | Supplying, installation, testing and commissioning of following capacity TPN tap off box made of 1.6 mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. |
| 65 | 100 A TPN |
| 66 | 200 A TPN |
| 67 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC conduit as required. |
| 68 | Supplying and fixing of 3 mm thick phenolic laminated sheet etc. as required. |
| 69 | Supplying and fixing of 100 x 50 mm PVC trunking with cover, on surface of wall etc. as required. (Make: Legrand / similar superior) |
| 70 | Supplying and fixing of SMC meter box of size 400 x 300 x 190 mm with hinged front door and viewing glass, on surface of wall etc. as required. (Make: Sintex / similar superior) |
| 71 | Supplying and fixing of 3 Phase, 4 Wire, 20 - 100 A, Direct base mounting LCD type kWh Meter in the existing meter box complete with testing and commissioning etc. as required. (Make: Lauritz Knudsen / similar superior) |
| 72 | Supplying and drawing of 35 sqmm PVC insulated copper conductor flexible cable etc. as required. |
| 73 | Supplying and making end termination with copper lug suitable for 35 sqmm PVC insulated copper conductor cable etc. as required. |
| 74 | Supplying and fixing of following sizes of MS members i/c making necessary drilling, cutting, welding, painting etc. as required |
| 75 | 40 x 5 mm MS Flat |
| 76 | Disconnecting and Removing of Fluorescent / CFL / LED lamp fittings of all types, Ceiling fans, PVC insulated copper conductor single core cables / PVC insulated and sheathed armoured aluminium / copper conductor cables, MS / PVC conduit / casing capping on surface, Cat 5/6 LAN cables, telephone cables, 5/15Amps switch boxes / Junction boxes, Single / Three Phase wall mount stabilisers, SPN / TPN Industrial socket outlet boxes, TPN Switchgear, SPN / TPN DBs on surface or in recess available in the entire II floor of TNT Complex Bldg at No. 60, Ethiraj Salai, Chennai and shifting the same to the desired location within the building premises as instructed by Engineer-in-charge etc. complete as required. |
| 77 | Removing of 1.5TR Split type AC Unit (Indoor & Outdoor) available in the II floor of TNT Complex building along with copper refrigerant pipes connecting indoor & outdoor unit i/c pumping down of refrigerant gas in the outdoor unit if required and shifting the same to the desired location within the building premises as instructed by Engineer-in-charge etc. as reqd. |
| 78 | 1.0 TR |
| 79 | 1.5 TR 500 KVA EA SET Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender