Power Government Departments Closing in 17 days TDR #56362756

Tender For Replacement Of Isolators, Ac/Dc Distribution Panels, Battery Bank And Battery Charger At Grid Station Bishnah And Supply And Erection Of Air Conditioners At Grid Station Bishnah

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
2.60 Crore
Estimated cost
Bid Submission
28 Jul 2026
17 days left
EMD
5.21 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Isolators, Ac/Dc Distribution Panels, Battery Bank And Battery Charger At Grid Station Bishnah And Supply And Erection Of Air Conditioners At Grid Station Bishnah

BOQ

Name of Work:- Replacement of Isolators, AC/DC Distribution Panels, Battery Bank and Battery Charger at Grid Station Bishnah And supply and erection of Air Conditioners at Grid Station Bishnah
Sl. No. Item Description
1Design, engineering and Supply of material
236KV, 50C/S,2500Amp, 31.5KA for one second, motor operated horizontal double break, outdoor type three pole isolator with one earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
336KV, 50C/S,2500Amp, 31.5KA for one second, motor operated horizontal double break, outdoor type three pole isolator without earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
4145KV, 50C/S, 2500Amp, 40KA for one second, motor operated horizontal double break, outdoor type three pole isolator with one earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
5145KV, 50C/S, 2500Amp, 40KA for one second, motor operated horizontal double break, outdoor type three pole isolator without earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
6245KV, 50C/S, 2500Amp, 50KA for one second, motor operated horizontal double break, outdoor type three pole isolator without earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
7245KV, 50C/S, 2500Amp, 50KA for one second, motor operated horizontal double break, outdoor type three pole isolator with one earthing switch with copper fixed and moving contacts/copper current carrying parts with galvanized iron mechanism box, SCADA compatible
8Marshalling box cum cooler control cabinet for 02 nos auto transformer and 01 no Power transformer consisting of auto coooling control system and various alarms and trip contacts of the transformer. The cooling systemcum marshalling box is as follows: 1. one no auto transformer consisting of 14 nos cooling fans and 04 nos cooling pumps with three WTIs and one OTIs along with various alarms and trips signals from the transformer. 2. one no power transformer consisting of 08 cooling fans wih one WTI and one OTI along with various alarm and trip signals from the transformer
9Marshalling kiosk with Kiosk frames Stainless steel/HotDip Galvanised structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm.Shall be provided with a degree of protection of IP: 55, with Copper Bar earthing for 33 kV.1. Marshalling Box shall be outdoor type ,rigidly constructed out of sheet steel or Aluminium and shall be dust, water & Vermin proof. Sheet steel used shall be at least 2.00 mm thick cold rolled.2. Bay Marshalling Kiosk shall have three separate distinct compartments for the following purposes:-I) To receive two incoming 415 V ,3Φ,63 Amps AC supplies with Auto changeover and MCB units and distribute minimum six outgoing 415 V ,3Φ,16 Amps supplies controlled by MCB with fuse failure remote indication.II) To distribute minimum 10 outgoing, 240 V,10 Amps supplies to be controlled by MCB to be drawn from three phase incomers.III) 200 Nos of Terminal blocks in vertical formation for interlocking facilties3. All sheet steel works shall be degreased, pickled, phosphate and than applied with two coats of Zinc chromate primer & two coats of finishing synthetic enamel paint. The color of finishing paint shall be light admiral grey in accordance with shade No 697 of IS:5 outside & insideshall be glossy white.
10220volts(D.C.) automatic float cum boost Battery charger three phase with: 1. float charging load current rating: 30/60/70/100 Amps at 220 volts to 252 volts. 2.boost current rating:50/55/60/70/80Amp at 198volts to 296volts D.c
11110volts(D.C.) automatic float cum boost Battery charger three phase with: 1. float charging load current rating: 30/60/70/100 Amps at 105 volts to 125 volts. 2.boost current rating:50/55/60/70/80Amp at 90 volts to 140 volts D.c
12AC Distribution Panel (415 V, AC) complete with ckt. Breakers, indicating Lamps etc for 220/132KV Grid Station.
13AC Distribution Panel (415 V, AC) complete with ckt. Breakers, indicating Lamps etc for 132/33KV Grid Station.
14D.C. Distribution Board(220volts) for Grid Station
15Battery bank 220volts, 300AH, of 110nos cells of 02 volts each, sealed maintenance free VRLA type, high impact copolymer container, flame retardent
16D.C. Distribution Board(110volts) for Grid Station
17Air Conditioner split type 2ton, 5 star rated, inverter technology, 5in1 convertible, turbo cool, anti-viral+PM 2.5 filter, 100% copper condenser with r32 refrigerant (commercial type) including 5 KVA Stablizer and 3 Core Copper FRLS flexible cable from AC Distribution Board to the AC units along with all allied acessories and 2 no. high speed cleaning washing pumps for Acs.
18Erection, testing and commissioning
19item no 1.01
20item no 1.02
21item no 1.03
22item no 1.04
23item no 1.05
24item no 1.06
25item no 1.07
26item no 1.08
27item no 1.09
28item no 1.10
29item no 1.11
30item no 1.12
31item no 1.13
32item no 1.14
33item no 1.15
34item no 1.16
35dismantling and write back of the existing material from item no 1.01 to 1.16 to the divisional store Narwal Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56362756
AUTHORITY Government Departments
TENDER VALUE 2.60 Crore
LAST DATE 28-07-2026
Authority
Authority Name Power Development Department
Work Description Tender for Replacement Of Isolators, Ac/Dc Distribution Panels, Battery Bank And Battery Charger At Grid Station Bishnah And Supply And Erection Of Air Conditioners At Grid Station Bishnah
Basic Detail
Tender No TLMD-VIII/J/T/07 of 2026-27 Dated-15/06/2026
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 08 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 2.60 Crore
Tender Fee 5000
EMD 5.21 Lakhs
Exemption Not Available
Document List
6e2b4a86-f88f-45b0-ad8b-7205d365cd9a.html
BOQ_1021140.xls
SBD07.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

6e2b4a86-f88f-45b0-ad8b-7205d365cd9a.html

xls

BOQ_1021140.xls

pdf

SBD07.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer