Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56360957

Tender For Maintenance, Repair And Replacement Of Damaged Mcb Dbs, Sub Main Wiring, Earthing And Ceiling/ Exhaust Fans, Geysers And All Internal Electrical Services At Naya Raipur Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Raipur, Chhattisgarh
Tender Value
9.50 Lakhs
Estimated cost
Bid Submission
29 Jul 2026
18 days left
EMD
19000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raipur → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Maintenance, Repair And Replacement Of Damaged Mcb Dbs, Sub Main Wiring, Earthing And Ceiling/ Exhaust Fans, Geysers And All Internal Electrical Services At Naya Raipur Mil Stn

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 10-Jul-2026 Corrigendum No 01 BOQ 29-Jul-2026

BOQ

Name of Work:- MAINTENANCE, REPAIR AND REPLACEMENT OF DAMAGED MCB DBs, SUB MAIN WIRING, EARTHING AND CEILING/ EXHAUST FANS, GEYSERS AND ALL INTERNAL ELECTRICAL SERVICES AT NAYA RAIPUR MIL STN
Sl. No. Item Description
1Taking down submain wiring size and any type
2Taking out MCB DBs of any size or any capacity and any type.
3S & F in rep in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar Triple pole and neutral 415 V, 4 Ways, double door type,complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T
4S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door type complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T
5S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door type complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T
6S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door type, including taking down of existing sheet metal enclosure complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T
7S & F in repair MCB SPN 40 to 63 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Indo Asian/Legrand/L&T/ Havells)
8S & F in repair MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Indo Asian/Legrand / L&T / Havells)
9S & F in repair MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells)
10M&L for replacement of damaged internal cover plate of MCB Distribution Board (DB) of any size and any type, of any module and way, complete with careful dismantling of existing cover plate, removal and refixing of MCBs and associated accessories, proper dressing and termination of internal wiring, making good disturbed connections, and carrying out testing and commissioning to ensure satisfactory operation of the distribution board
11Supply and fix in repair sheet metal enclosure earth plug socket for SP 20 amps, with single pole MCB 240 volts.
12S & F in repair PVC insulated unsheathed twin core multistrand aluminum cable of size 10 sqmm complete all as specified and directed.
13S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 1.5 sqmm all as specified and directed. Make Anchor/Polycab/Havells
14S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 2.5 sqmm all as specified and directed. Make Anchor/Polycab/Havells
15S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 4.0 sqmm all as specified and directed. Make Anchor/Polycab/Havells
16S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 6.0 sqmm all as specified and directed. Make Anchor/Polycab/Havells
17M&L in rep for submain wiring comprising single core, 2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia PVC conduits and conduit fittings complete including S & F in rep 1 X 6 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire .
18All as per item No 17 above but with 2 x 4 sqmm and 1x 4 sqmm as earth wire.
19All as per item No 17 above but with 2 x 2.5 sqmm and 1x 2.5 sqmm as earth wire. Please Enable Macros to View BoQ information
20All as per item No 17 above but with 2 x 2.5 sqmm and 1x 2.5 sqmm as earth wire. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56360957
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.50 Lakhs
LAST DATE 29-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Maintenance, Repair And Replacement Of Damaged Mcb Dbs, Sub Main Wiring, Earthing And Ceiling/ Exhaust Fans, Geysers And All Internal Electrical Services At Naya Raipur Mil Stn
Basic Detail
Tender No 8400/445/E8
Bidding Type Tender
Location
City Raipur
State Chhattisgarh
Key Dates
Publish Date 10 Jul 2026
Submission Date 29 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 9.50 Lakhs
Tender Fee 500
EMD 19000
Exemption Not Available
Document List
BOQ_870433.xls
e0c42fda-63c7-4c3d-bad6-988524d92f89.html
Tendernotice_1 (4).pdf
TenderPage445.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 18 days
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_870433.xls

html

e0c42fda-63c7-4c3d-bad6-988524d92f89.html

pdf

Tendernotice_1 (4).pdf

pdf

TenderPage445.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders