Tender For Maintenance, Repair And Replacement Of Damaged Mcb Dbs, Sub Main Wiring, Earthing And Ceiling/ Exhaust Fans, Geysers And All Internal Electrical Services At Naya Raipur Mil Stn
Tender Overview
Project Description
Tender for Maintenance, Repair And Replacement Of Damaged Mcb Dbs, Sub Main Wiring, Earthing And Ceiling/ Exhaust Fans, Geysers And All Internal Electrical Services At Naya Raipur Mil Stn
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Jul-2026 | Corrigendum No 01 | BOQ | 29-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down submain wiring size and any type |
| 2 | Taking out MCB DBs of any size or any capacity and any type. |
| 3 | S & F in rep in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar Triple pole and neutral 415 V, 4 Ways, double door type,complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T |
| 4 | S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door type complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T |
| 5 | S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door type complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T |
| 6 | S & F in rep Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 12 Ways, double door type, including taking down of existing sheet metal enclosure complete all as specifide and directed. Make- Indo Asian/Legrand/Havells/L&T |
| 7 | S & F in repair MCB SPN 40 to 63 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Indo Asian/Legrand/L&T/ Havells) |
| 8 | S & F in repair MCB SP 5 to 32 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Indo Asian/Legrand / L&T / Havells) |
| 9 | S & F in repair MCB TPN 40 to 100 Amps, 240 Volts, minimum 10 KA, \\"C\\" series rupturing capacity and to be housed in DBs catered here in before complete all as specified and directed :-(Make- Legrand / L&T / Havells) |
| 10 | M&L for replacement of damaged internal cover plate of MCB Distribution Board (DB) of any size and any type, of any module and way, complete with careful dismantling of existing cover plate, removal and refixing of MCBs and associated accessories, proper dressing and termination of internal wiring, making good disturbed connections, and carrying out testing and commissioning to ensure satisfactory operation of the distribution board |
| 11 | Supply and fix in repair sheet metal enclosure earth plug socket for SP 20 amps, with single pole MCB 240 volts. |
| 12 | S & F in repair PVC insulated unsheathed twin core multistrand aluminum cable of size 10 sqmm complete all as specified and directed. |
| 13 | S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 1.5 sqmm all as specified and directed. Make Anchor/Polycab/Havells |
| 14 | S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 2.5 sqmm all as specified and directed. Make Anchor/Polycab/Havells |
| 15 | S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 4.0 sqmm all as specified and directed. Make Anchor/Polycab/Havells |
| 16 | S & F in repair PVC insulated unsheathed multistranded single core copper conductor of size 6.0 sqmm all as specified and directed. Make Anchor/Polycab/Havells |
| 17 | M&L in rep for submain wiring comprising single core, 2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia PVC conduits and conduit fittings complete including S & F in rep 1 X 6 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire . |
| 18 | All as per item No 17 above but with 2 x 4 sqmm and 1x 4 sqmm as earth wire. |
| 19 | All as per item No 17 above but with 2 x 2.5 sqmm and 1x 2.5 sqmm as earth wire. Please Enable Macros to View BoQ information |
| 20 | All as per item No 17 above but with 2 x 2.5 sqmm and 1x 2.5 sqmm as earth wire. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 18 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender