Housing Urban and Rular Development Government Departments Closing in 15 days TDR #56360775

Tender For P And F Of Heavy Duty Exhaust Fan And Heavy Duty Industrial Wall Mounted Air Circulator Fan And Led Flood Light And Led Street Light At Khelgaon Different Location. 2911

Issued by Government Departments · Udaipur, Rajasthan
Tender Value
9.98 Lakhs
Estimated cost
Bid Submission
23 Jul 2026
15 days left
EMD
19960
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for P And F Of Heavy Duty Exhaust Fan And Heavy Duty Industrial Wall Mounted Air Circulator Fan And Led Flood Light And Led Street Light At Khelgaon Different Location. 2911

BOQ

Name of Work:- P and F of Heavy Duty Exhaust Fan and Heavy Duty Industrial Wall Mounted Air Circulator Fan and Led Flood Light and Led Street Light at Khelgaon Different location. 2911
Sl. No. Item Description
1Item Code [Heavy Duty Industrial Met]:Item Type [Electrical] ::Supplying, installation, testing and commissioning of Heavy Duty Industrial Metal Exhaust Fan of size 600 mm sweep, approx. 900 RPM, capable of delivering an air displacement of not less than 10000 m³/hr, operating on 220-240 Volts, Single Phase, 50 Hz AC supply. The fan shall be equipped with a highly efficient heavy-duty motor (approx. 500 Watts power consumption), robust metal/resin blades, and a specially designed protective guard to make it foreign matter proof. Complete with all necessary mounting accessories, hardware, making connections as required and including a minimum of 24 months manufacturer warranty. (Make: Orient Electric or equivalent approved by Engineer-in-charge).
2Item Code [Heavy Duty Industrial Wal]:Item Type [Electrical] ::Supplying, installation, testing and commissioning of Heavy Duty Industrial Wall Mounted Air Circulator Fan of size 750 mm (30\\") sweep, oscillation type propeller fan, complete with an impeller consisting of 3 dynamically balanced blades. The fan shall be equipped with a high-performance motor operating on 240V, Single Phase, 50 Hz AC supply, having a power input not exceeding 250W, rated speed of approx. 1440 RPM, and minimum air delivery capacity of 22200 $m^3/hr$ (13066 CFM). The assembly must include a 3-speed setting arrangement, robust wall/column mounting bracket, sturdy metallic guard for safety, making necessary electrical connections, testing and leaving the installation in perfect working order with a minimum 2-year manufacturer warranty. (Make: Crompton or equivalent approved by Engineer-in-charge).
3Item Code [Rewinding of 250 KVA Copp]:Item Type [Electrical] ::Rewinding of 250 KVA Copper Wound Transformer including dismantling of burnt / damaged HT & LT copper winding, insulation material, cleaning of core, rewinding with super enamelled copper conductor of approved make, replacement of insulation papers, sleeves, varnishing, baking, assembling, transformer oil filtration / refilling, testing and commissioning complete as required at site.
4Item Code [1.4-2025]:Item Type [Electrical] ::Sub Item Code [1.4-2025 + 1.4.2]: S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. 25 mm
5Item Code [15.7-2025]:Item Type [Electrical] ::Sub Item Code [15.7-2025 + 15.7.3]: Providing & Fixing of BEE Star rated copper wounded with class of Insulation F, double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
6Item Code [18.11-2025]:Item Type [Electrical] ::Sub Item Code [18.11-2025 + 18.11.9]: Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. High Power LED Flood Light Minimum lumen output 32500 lm
7Item Code [18.13-2025]:Item Type [Electrical] ::Sub Item Code [18.13-2025 + 18.13.7]: Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. LED Street Light fixture with Minimum lumen output 12500 lm
8Item Code [18.19-2025]:Item Type [Electrical] ::Sub Item Code [18.19-2025 + 18.19.4]: Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. 40 mm Dia.
9Item Code [4.1-2025.]:Item Type [Electrical] ::Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. Sub Item Code [4.1-2025. + 4.1.8]: Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 3 x 2.5 sq.mm
10Item Code [7.15-2025]:Item Type [Electrical] :: Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
11Item Code [7.4-2025]:Item Type [Electrical] :: Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56360775
AUTHORITY Government Departments
TENDER VALUE 9.98 Lakhs
LAST DATE 23-07-2026
Authority
Authority Name Urban Improvement Trust
Work Description Tender for P And F Of Heavy Duty Exhaust Fan And Heavy Duty Industrial Wall Mounted Air Circulator Fan And Led Flood Light And Led Street Light At Khelgaon Different Location. 2911
Basic Detail
Tender No NIT_29_11
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 08 Jul 2026
Submission Date 23 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 9.98 Lakhs
Tender Fee 590
EMD 19960
Exemption Available
Document List
110d56f7-7bf4-465c-920c-2361415cc3b4.html
BOQ_1020784.xls
Conditions_11.pdf
Tendernotice_1 (27).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

110d56f7-7bf4-465c-920c-2361415cc3b4.html

xls

BOQ_1020784.xls

pdf

Conditions_11.pdf

pdf

Tendernotice_1 (27).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders