Heavy Industries and Public Enterprises Government Departments Closing in 5 days TDR #56358803

Tender For Construction Of Operator Office Of Compressor Station Inside Within Existing Workshop Including Partitioning, Doors, Windows, Glazing And False Ceiling Complete As Per Specifications For Dnp Limited At Madhuban, Duliajan

Issued by Government Departments · Dibrugarh, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Jul 2026
5 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Operator Office Of Compressor Station Inside Within Existing Workshop Including Partitioning, Doors, Windows, Glazing And False Ceiling Complete As Per Specifications For Dnp Limited At Madhuban, Duliajan

BOQ

Name of Work:- Construction of Operator Office of Compressor Station inside within existing workshop including partitioning, doors, windows, glazing and false ceiling complete as per specifications for DNP Limited at Madhuban, Duliajan
Sl. No. Item Description
1Civil Part
2Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive),consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete. Partition Specification: 66 mm overall thickness partition using 8 mm thick one side and 12mm other side, double skin multipurpose cement board Type-B, Category-III as per IS: 14862 : 2000 reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) with suitable fibre cement screws
3Float glass panes of 5mm thickness(Weight not less than 12.50 kg/m2)
4Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded builtup tubular sections/appropiate Z sections and other sections of approved make cinforming to IS 733 and IS 1285, fixing with dash fastners of required dia and size, including necessary filling up the gaps at junctions i.e., at top, bottom and sides with required EPDM rubber/neoprene gaskate etc. Aluminium sections shall be smooth, rust free, straight, mitred and joined mechanically wherever required cleat angle, aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge.(Glazing, panelling and dash fastners to be paid for separately)
5Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
6Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :
7Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge.
8Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheets and galvanized with zinc coating of 120 gm/m² (Both side inclusive) as per IS: 277 and consisting of angle cleats of size 25mm wide × 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fasteners 12.5mm dia into 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 × 10 × 0.50mm of required length with nut and bolts of required sze and other end of angle hanger fixed with intermediate GI channels 45 ×15 × 0.9mm running at the spacing of 1200mm centre to centre, to which the celing section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre , shall be fixed in a direction perpendicular to GI intermediate channel with connecting clips made out of 2.64mm dia into 230mm long GI wire at every junction, including fixing perimeter channels 0.5mm thick 27mm heigh having flanges of 20mm and 30mm long, the perimeter of celing fixed to wall/ pertition with the help of rawl plugs at 450mm centre, with 25mm long dry wall screws @230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 × 25mm at 230 mm centre to centre, including jointing and finishing to a flash finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in three layrs covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufactures specifications and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specifications and direction of the engineer in charge but excluding the cost of painting with : 12.5mm thick tapered edge gypsum moiture resistant board.
9particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 25 mm thick
10Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
11Electrical Part
12Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
13Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
15Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
16Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
17Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
19Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
20Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
21Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
22Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
23Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322…………..(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 12 -15 watt
24Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable)…………..(Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)18- 22 Watt Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56358803
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 14-07-2026
Authority
Authority Name Department Of Industries And Commerce
Work Description Tender for Construction Of Operator Office Of Compressor Station Inside Within Existing Workshop Including Partitioning, Doors, Windows, Glazing And False Ceiling Complete As Per Specifications For Dnp Limited At Madhuban, Duliajan
Basic Detail
Tender No DNPL/CIVIL/WORKSHOP/RM/100
Bidding Type Tender
Location
City Dibrugarh
State Assam
Key Dates
Publish Date 08 Jul 2026
Submission Date 14 Jul 2026
Open Date 16 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee 200
EMD Ref. Documents
Exemption Not Available
Document List
527f0f5b-321e-4128-8e0d-983bfcb02833.html
BOQ_83538.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

527f0f5b-321e-4128-8e0d-983bfcb02833.html

xls

BOQ_83538.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders