Tender For Work Regarding The Installation Of A Unit Within The Chambers And Retiring Rooms Of The District Judge/Additional District Judge At The District Court, Barabanki.
Tender Value
1.15 Crore
Estimated cost
Bid Submission
03 Aug 2026
6 days left
EMD
7.80 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Barabanki → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Work Regarding The Installation Of A Unit Within The Chambers And Retiring Rooms Of The District Judge/Additional District Judge At The District Court, Barabanki.
BOQ
| Sl. No. | Item Description |
| 1 | जनपद न्यायालय बाराबंकी मे ए0सी0 स्थापना का कार्य (Part-A)SITC of Air Cooled Hi Wall split type AC complete with indoor unit, Outdoor unit,Concealed copper refigerant piping with insulation inverter type-cooling only 2.0 TR 5 Star BEE Rating.The System Shall be able to operate up to 52°C (Outdoor ambient Temperature) Make:- Carrier /Panasonic/Blue Star/LG |
| 2 | SITC of Air Cooled Hi Wall split type AC complete with indoor unit, Outdoor unit,Concealed copper refigerant piping with insulation inverter type-cooling only 1.5 TR 5 Star BEE Rating.The System Shall be able to operate up to 52°C (Outdoor ambient Temperature)Make:- Carrier /Panasonic/Blue Star/LG |
| 3 | SITC 4 KVA Automatic Voltage Stablizer(130-280V) Copper Winding.Approved Make |
| 4 | SITC 5 KVA Automatic Voltage Stablizer(130-280V) Copper Winding.Approved Make |
| 5 | S/L of 2.5 sqmm 4 Core round copper cable for indoor unit to outdoor unit. |
| 6 | S/L of 2.5 sqmm 3 Core round copper cable for Stabilizer to indoor unit. |
| 7 | SITC of Suction/Discharge both copper pipe line in split A.C. Unit 1.5 ton capacity including brazing, nitrile, rubber insulation 6mm thick class 'O' etc complete 1/4\\" (6.40 mm) and 1/2\\" (12.70 mm) |
| 8 | SITC of Suction/Discharge both copper pipe line in split A.C. Unit 1.8/2.0 ton capacity including brazing, nitrile, rubber insulation 9mm thick class 'O' etc complete 3/8\\" (9.50 mm) and 5/8\\" (15.90 mm) |
| 9 | Supply and laying of Heavy Duty PVC Plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessories complete. |
| 10 | Supply and Fixing of Outdoor Unit stand for split type A.C. |
| 11 | Supply , Fabrication and Installation of M.S.cage for protection of Outdoor unit from animal/theft L X W X H 1300 mm X 600 mm X 1200 mm complete in all respect. |
| 12 | S/F of 2mm thick trans parent polythin curtain with all assesories etc. |
| 13 | Supply and fixing of 100 mm width X 60 mm depth X 5 mm thickness DLP PVC Trunking System. |
| 14 | जनपद न्यायालय बाराबंकी मे ए0सी0 के विद्युत संबंधी कार्य (Part-B)S/F of DP Sheet Steel enclosure on surface/recess along with 25/32 amp. 240V \\"C\\" curve DP MCB complete with connection,testing and commissioning etc. as required. |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 16 | 2x6 sqmm. + 1x6 sqmm. |
| 17 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, VTPN MCB distributionboard of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 18 | S/F of 40 Amp.FPMCB (10KA) C-Series |
| 19 | S/F of 63 Amp.FPMCB (10KA) C-Series |
| 20 | S/F single pole blanking plate in the existing MCB DB complete etc. as required |
| 21 | Supply and fixing of 240 volts C Curve 5A. To 32A. amp SP miniature circuit breaker suitable for inductive load of following poles in the existing MCB, DB complete with connection, testing and commissioning etc. |
| 22 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering. |
| 23 | Incoming :- 200 Amp. MCCB FP 36kA - 01 NoOutgoing :- 63 Amp. MCCB FP 36kA - 03 Nos.-32/40 Amp. MCCB FP 36kA - 01 Nos. |
| 24 | Incoming :- 800 Amp. MCCB FP 36kA - 01 NoOutgoing :- 125 Amp. MCCB FP 36kA -01 Nos. - 200 Amp. MCCB FP 36kA -03 Nos.- 63 Amp. MCCB FP 36kA -02 Nos. |
| 25 | Incoming :- 125 Amp. MCCB FP 36kA - 01 NoOutgoing :- 63 Amp. MCCB FP 36kA -02 Nos. |
| 26 | Incoming :- 200 Amp. MCCB FP 36kA - 01 NoOutgoing :- 63 Amp. MCCB FP 36kA -03 Nos. |
| 27 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 V grade on wall as directed by the Engineer-Incharge, complete in all respect including exavation and refilling. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 28 | 400 sqmm 3-1/2 Core |
| 29 | 150 sqmm 3-1/2 Core |
| 30 | 70 sqmm 3-1/2 Core |
| 31 | 50 sqmm 3-1/2 Core |
| 32 | 35 sqmm 3-1/2 Core |
| 33 | Supply and making of end termination with brass compression gland and Aluminium Lugs for following size of PVC insulated PVC Sheathed/ XLPE Aliminium Conductor cable of 1100 V grade as required. |
| 34 | 400 sqmm 3-1/2 Core |
| 35 | 150 sqmm 3-1/2 Core |
| 36 | 70 sqmm 3-1/2 Core |
| 37 | 50 sqmm 3-1/2 Core |
| 38 | 35 sqmm 3-1/2 Core |
| 39 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 40 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 41 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 42 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 43 | Earthing with GI earth pipe 4.5 mtr long 40mm dia including accessories & providing masonry encloser with cover plate havig loking arrangment & watering pipe etc. with charcoal/ coke and salt as required. |
| 44 | Providing and fixing of 25mmx5mm G.I. strip on surface or in recess for connections etc. as required. |
| 45 | S/R of fire extinguisher ABC type 6.00 Kg. capacity (ISI Marked IS:15683& A.C. approved) complete with internal charge and wall bracket alongwith supply of all material and labour complete in all respect. |
| 46 | S/R of CO2 type fire extinguisher 4.5 Kg. capacity (ISI marked : 2878 & TAC approved) with intal changed and wall bracket along with supply of all material and labour for Proper complete of work. |
| 47 | S/L of Electrical Insulation Rubber sheet size 2mm x 1mtr x 2mtr complete |
| 48 | S/F of Danger board Fabricated from 10 gauge MS Sheet as per IE Rules. |
| 49 | S/F of 63Amp. FP Switch disconnector Fuse bolted type with three fuses in sheet steel enclosure complete in all respect. Make- Havells make. |
| 50 | S/F of 1250 A FP EDO type A.C.B. 65KA with Triple Busbar arrangement complete in all respect. |
| 51 | Less @ 5% Deducted by PFAD |
| 52 | Add : GST @18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender