Tender For Various Electricity Line Works, In Deposit Scheme Runnlng Contract, In The Jurisdiction Of Eddpilkhuwa, Under Edc Hapur
Tender Value
40 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
2 days left
EMD
40000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hapur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Various Electricity Line Works, In Deposit Scheme Runnlng Contract, In The Jurisdiction Of Eddpilkhuwa, Under Edc Hapur
BOQ
| Sl. No. | Item Description |
| 1 | FOR VARIOUS ELECTRICITY LINE WORKS, IN DEPOSIT SCHEME (RUNNLNG CONTRACT), IN THE JURISDICTION OF EDD-PILKHUWA, UNDER EDC HAPUR |
| 2 | Carriage of all petty material of estimate, from Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 3 | Carriage of ST Pole I I mtrs. Long from Electricity store center, Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 4 | Carriage of PCC Pole 8.5 mtrs. Long from Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 5 | Carriage of 10KVA to 250KVA from Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 6 | Carriage of 11KV CT/PT Unit from Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 7 | Carriage of Metering Cubical Set Complete, from Electricity Store Centre at Hapur / J.E. Store to the site of work, including loading and unloading at both ends. The work shall be executed over kachha and pakka roads as per the directions of the Site In-charge. The scope includes arrangement of suitable transport, labour for loading/unloading, and all necessary Tools & Plants (T&P). The lead distance shall be up to 0–50 Km, covering stores located at Hapur / Ghaziabad / Bulandshahr. |
| 8 | Erection & Fixing of PCC Pole 8.5 mtr. long in I l KV line after digging o suitable pits including fixing of requisite all accessories as per RESPO Drawing Norms by providing F•Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge. |
| 9 | Errection & Fixing of PCC Pole 8.5 mtr. long in LT. line are digging of suitable pits including fixing of requisite accessories as per RESPO Drawing Norms by providing LT. Pin Clamps, M.S. Flat of size 50x6 & Schacle Insulator of size 75x90mm, with proper size nuts and bolts, as per direction of site incharge. |
| 10 | Erection & Fixing of STP Pole I I mtr. long in I l KV line after digging o suitable pits including fixing of requisite all accessories as per RESPO Drawing norms by providing F-Bracket and holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts., as per direction of site incharge. |
| 11 | Erection of double pole structure with all accessories on ST Pole I I mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. T/F Angle, E Bracket, I l KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing/ Norns by providing all clamps made of M.S. Flat o size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge. |
| 12 | Erection of double pole structure with all accessories on PCC Pole 8.5 mtr. long, fabrication and fixing of M.S. Top & Dropper Channel, M.S. TIF Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting etc., as per RESPO Drawing Norms by providing all made o M.S. Flat of size 50x6 mm with proper size nuts and bolts, and jumpering etc work, as per direction of site incharge. |
| 13 | Safely installing transformer with the help of crane/manual labour at LT Sub-Station Double Pole/Plinth, as per direction o site incharge. |
| 14 | Safely installing the 1 1KV CT/PT Unit with the help of crane/manual labour at Sub-Station Double Pole/Plinth, as per direction of site incharge. |
| 15 | Laying of 140/160mrn O/D PN-4PE-80 PN.4 grade UV stabilized IIDPE pipe per IS of 6mctcr, for laying of underground Cable as pcr RESPO/Norms, including cost of above IIDPE pipe, as per direction of site incharge |
| 16 | Laying of 1 1 KV and 33KV XLPE cable under ground (50x2-lOO Double Circuit) into IIDPE Pipe, spare cable shall be left in the loop shape at both ends as per RESPO/Norms, as per direction of site incharce. |
| 17 | Digging of earth and refling with road restoration pucca charge as per RESPO/Drawing Norms. (The Firm will be fully responsible for this work and taking necessary permission), as per direction of site inchargc |
| 18 | Digging of earth and refling with road restoration Kaccha/footpath charge as per RESPO/Drawing Norms. (The Firm will bc fully responsible for this work and taking necessary permission), as per direction of site incharge |
| 19 | Laying of 11K V ABC of various capacity and completion work properly, as per RESPO/Norms and as per direction of site incharge. |
| 20 | Laying of 11KV XLPE Cable 3x35-3x70+3x120-3x185sqmm and completion work properly, as per RESPO/Norms, and as per direction of site incharge. |
| 21 | Laying of LT ABC of various capacity and completion work properly, as per RESPO Norms, and as per direction of site incharge. |
| 22 | Erection & Fixing of Distribution Box on pole by providing 02 Nos. DIB Clamps & proper size nut & bolts, as per direction of site incharge. |
| 23 | Providing and fixing of Suspension Clamp with Eye Hook as per RESPO Norms and as per direction of site incharge. |
| 24 | Providing and fixing of Dead End Clamp with Eye Hook, as per RESPO/Norms and as per direction of site incharge. |
| 25 | Making and filling of 11KV Cable Jointing Kit, Indoor/outdoor type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms, and as per direction of site incharge. |
| 26 | Installation of 11KV Metering Cubical Complete work as per RESPO Norms, and as per direction of site incharge. |
| 27 | Fabrication & Fixing of T•Channel on pole by providing Holding Clamps, F• Clamps & Proper size nuts & bolts, as per RESPO/Norms and as per direction of site incharge |
| 28 | Grouting & fixing of stay rods (20x1800)mm including all work o excavation, cement concrete in size (0.60x0.60xO.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops, as per direction of site incharge. |
| 29 | Earthing of supports with MS earth Rod of (20x2500) mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts, as per direction of site incharge. |
| 30 | Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballst) Grouting will be done in the block of size (450x450)mm xl/6th o full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials, as per direction of site incharge |
| 31 | Wrapping of barbed wire on 11KV ST/PCC poles as anti-climbing device for a length of 0.9mtrs. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75 mtr from the ground complete, including providing & fixing of lower end & upper end clamps made of M.S. Flat 40X5mm complete with nuts & bolts and all other required material and T&P., as per direction of site inchargc. |
| 32 | Fabrication of Guarding Angle X Arm & other requisites material for guarding by drawing 02Nos G.I Wire and making loop at suitable distance as per RESPO drawing Norms by providing holding 02Nos. Eye bolts made of M.S. round size 12mm dia-100mm long & Cross Arm clamps made of M.S. Flat of size 50X6mm and bolts as per norms of RESPO Lucknow, and as per direction of site incharge. |
| 33 | Laying , Stringing and final sagging of ACSR Weasel Conductor, as per RESPO[Drawing Norms and as per direction of site incharge. |
| 34 | Laying , Stringing and final sagging of ACSR Rabbit Conductor, as per RESPO[Drawing Norms and as per direction of site incharge. |
| 35 | Laying , Stringing and final sagging of ACSR Dog Conductor, as per RESPO/Drawing Norms and as per direction of site incharge. |
| 36 | Providing & Fixing of (3.1. pipe 6\\"dia Class-B over 11KV 3X70 and 3x120Sq.mm XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be buried under carth about 500mm each including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends, as per direction of site incharge. |
| 37 | Construction of TIF plinth suitable for 250KVA (size of 2x2x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). 1st class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 are duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour, as per direction o site incharge. |
| 38 | Erection & Fixing of 11KV. Fuse set on STP/PCC Pole, by providing all required fixing materials as per RESPO/Norms and as per direction of site incharge. |
| 39 | Erection & Fixing of 1 IKV. TPMO set on STP/PCC Pole, by providing all required fixing materials as per RESPO Norms and as per direction of site incharge. |
| 40 | Construction of safety fencing (MS) for Transformer 11/0.4 KV Sub Station, With supply of material required for MS fencing (50X50X3 MM) M.S. wire mesh construction utilizing vertical post duly grouted/fitted in ground/on floor. Horizontal anglen-iron to be fitted on vertical posts. Pickets (i required) fitted to rail and gate to facilitate entry and exit. The vertical Posts/Horizontal post shall be made of M.S. angle 75x75x6mm. Such post shall be kept preferably at distance of 800-1000 MM. and shall be grounded with CC ratio 1:4:8. The length of vertical post shall be sufficient to take care of fencing as requirement at site, and as per direction of site incharge. |
| 41 | Providing & Fixing of Danger Board, including fixing of all accessories by providing all required materials (like suitable nuts & bolts etc.) as per RESPO/Drawing Norms and as per direction of site incharge. |
| 42 | Providing & Fixing of Number Plate alongwith all required accessories (like suitable clamps, nuts & bolts etc) as per RESPO/Drawing Norms and per direction of site incharce. |
| 43 | Safely dismantling work properly and carriage of old & used STP/PCC from site of two Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road as per direction of site incharge. |
| 44 | Safely dismantling & removal and carriage of old & used ACSR Conductor from site Of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge |
| 45 | Safely dismantling Work properly and carriage of old & used 25/63KVA T/F from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge. |
| 46 | Earthing of neutral & body of TIF By Boring and lowering of G.I. Pipe size 32 mm dia... into the ground up to water level 120 fit. With the lower end o solid copper cone approx. 225mm long and 750 gm. in weight shall be provided and in pipe as well as bringing out a continuous copper wire 6 SWG from the cone up to the ground surface where it will bc bolted to the Nf.S. earth strip for TIF neutral connection, the earth strip '*Vill be welded to the G.l. pipe and neutral earthing support, as per direction of site incharge. |
| 47 | Providing and installation of maintenance free multifaceted proactive and corrosion free chemical earthing electrode size 80mm x 3000mm complete with 50KG backfill compound with all required accessories for Body/neutral earthing of Transformers, including cost of M.S. carth strip for connection the earth strip will be soiled to the earthing and neutral support, as per RESPO Norms and as per direction of site incharge. |
| 48 | Jumpering and line energisation work properly as per RESPO Norms and as per direction of site incharge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender