Defence Government Departments Closing in 10 days TDR #56356193

Tender For Repair And Maintainance Of Tennis Court With Synthetic Acrylic Paint At Khasiamangal C Us 104 Bn Bsf Under Shq Bsf Teliamura. (Sh: Electrical)

Issued by Government Departments · Khowai, Tripura
Tender Value
1.49 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
10 days left
EMD
2995
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khowai → Tripura
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintainance Of Tennis Court With Synthetic Acrylic Paint At Khasiamangal C Us 104 Bn Bsf Under Shq Bsf Teliamura. (Sh: Electrical)

BOQ

Name of Work:- Repair and maintainance of Tennis court with synthetic acrylic paint at khasiamangal c us 104 Bn BSF under SHQ BSF Teliamura. (SH: Electrical)
Sl. No. Item Description
1LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 250 watt
2Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
3Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
4Single pole
5Supplying and laying of PVC insulated and PVC sheathed Aluminium conductor power cable of 1.1 KV grade of 3 X 25 sqmm size in the existing RCC/ HUME/ METAL pipe/DWC pipe as required.Make-Havells/Polycab/Finolex/KEI
6Supplying and laying of PVC insulated and PVC sheathed Aluminium conductor power cable of 1.1 KV grade of 3 X 25 sqmm size as loop .Make-Havells/Polycab/Finolex/KEI
7Providing and fixing of cable junction box/loop box of size (130 x 180 x 77) mm on esixting pole with the help of suitable size clamp including connector, connections etc required.
8Painting of exposed portion of steel tubular poles, swaged type 07 mtr long, with 2 coat of aluminium paint and 1 coat priming including scraping give an even shade i/c cleaning of surface with sand proof regmal as required. As per direction of Engineer in charge.
9Fabrication, supplying/installation, testing and commissioning of hut type out door joint box duly painted with powder coated of size 400 mm x 400 mm x 400 mm deep made out of 2 mm Thick CRCA sheet having 4 strip aluminum bus bar duly PVC sleeved marked with (Red,Yellow,Blue & N(black) of busbar capacity 400A mounted in it with help of insulators along with locking arrangement ,danger plate, bottom base plate for cable entry and two nos earthing studs with angle iron frame of size 45 mm x 45mm x 5 mm and long 0.6 mtr to be fixed in cement concrete as per direction of Engg in charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56356193
AUTHORITY Government Departments
TENDER VALUE 1.49 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Border Security Force
Work Description Tender for Repair And Maintainance Of Tennis Court With Synthetic Acrylic Paint At Khasiamangal C Us 104 Bn Bsf Under Shq Bsf Teliamura. (Sh: Electrical)
Basic Detail
Tender No 10/AE(Elect)/SHQ TLM/2025-26
Bidding Type Tender
Location
City Khowai
State Tripura
Key Dates
Publish Date 08 Jul 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 1.49 Lakhs
Tender Fee Ref. Documents
EMD 2995
Exemption Available
Document List
BOQ_963046.xls
cd6a4334-662c-44ba-a104-b4e5061ee77d.html
Tendernotice_1 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_963046.xls

html

cd6a4334-662c-44ba-a104-b4e5061ee77d.html

pdf

Tendernotice_1 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders