Agriculture Boards / Undertakings / PSU Closing in 8 days TDR #56353080

Tender For Annual Repairs & Maintenance Of Electrical Installations At Fsd Balaghat (Navegoan), Balaghat (Kosmi), Jabalpur, Seoni, Katni, Katangi And Waraseoni Under District Office Jabalpur.

Issued by Boards / Undertakings / PSU · Jabalpur, Madhya Pradesh
Tender Value
43.41 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
8 days left
EMD
86850
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jabalpur → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Repairs & Maintenance Of Electrical Installations At Fsd Balaghat (Navegoan), Balaghat (Kosmi), Jabalpur, Seoni, Katni, Katangi And Waraseoni Under District Office Jabalpur.

BOQ

Name of Work:- Annual Repairs & Maintenance of Electrical installations at FSD Balaghat (Navegoan), Balaghat (Kosmi), Jabalpur, Seoni, Katni, Katangi and Waraseoni Under District Office Jabalpur.
Sl. No. Item Description
1Sub Head - 1 (Establishment)
2Repairs and maintenance of following electrical and mechanical installations, details as follows and according to terms and conditions mentioned as per I.E. rules with specified attendance of wiremen and helpers/khallsis. a) E.i., Lights/Fans/Plug Points/Power Points and Street/Compound lightning arrangements as per I.E. Rules as detailed inside at page.b) Water Supply arrangementc) Water Coolers d) Air Coolers e) Air conditioner f) Feeder pillars/LT panels maintenance. (including EPF & ESIC).
3Note:(1) Contractor may read all the clauses including \\"GENERAL DESCRIPTION OF WORK FOR AMC OF ELECTRICAL AND MECHANICAL SERVICES\\" and ''Condition of contract'' of the MTF carefully before quoting rates. (2) Wages paid to the worker for this work must not less than minimum wage as provided by chief labour commissioner(C), ministry of labour & Employment(3) In addition to all the documents as described in MTF Clauses the Contractor has to submit Monthly Wagesheets & EPF/ ESIC Challans. (4)The contractor may be asked to produce Monthly Transaction receipt of monthly wage to be paid to the employed labour.(5) In case of non compliance of EPF act 1952/ partial submission of EPF Contribution, as specified in Condition of contract Clause 19B, FCI will be at liberty to withhold the pending bills, Security Deposit etc., and or any other payments due to the Contractor.(6) The contractor must arrange for all types ofladders (Self supported & wall supported), safetygears and tools at sites w.r.t. Working height up to20 feets in suspension / wall or pole.
4FSD Balaghat (Navegoan)
5FSD Balaghat (Kosmi)
6FSD Jabalpur
7FSD Seoni
8FSD Katni
9FSD Katangi
10FSD Waraseoni
11Sub Head - 2 Materials only, for installation, no labour charges is to be involve, as the same has to be get replaced by staff supplied under AMC contract.
12Supply of XLPE insulated PVC sheathed cable of 1.1 KV grade (heavy duty) armoured under ground aluminium conductor cable as required confirming to IS-1554(Part-1) with up to date amendments of the following sizes. : 2 x 10 sqmm
134 x 16 sqmm
144 x 25 sqmm
15For Repairing of ceiling fan / exhaust fan : Capacitor
16Bearing
17Rewinding including credit the damage wire
18Supply of FRLS PVC Insulated copper conductor single core cable of following sizes : 1.5 sqmm
192.5 sqmm
204 sqmm
21Supply of following 6 amp to 32 amp capacity \\"c\\" curve MCB, Isolator and RCCB
22Single pole MCB
23Double pole MCB
24Triple pole and neutral MCB
25Supply of 25 amp capacity 30ma to 300ma breaking capacity RCCB
26Supply of 63 amp capacity 30ma to 300ma breaking capacity RCCB
27Providing for replacement of driver/ LED plate of following range of wattage capacity of well glass/ street light as required.
2830W to 70W
2971W to 150W
30Supply of following sizes PVC conduit with saddle(Labour part involved vide AMC labour at Item 1)
3120 mm dia
32Supplying of following sizes of steel conduit along with accessories in surface/recess including painting(Labour part involved vide AMC labour at Item 1) : 20 mm
33Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Derived on DSR)
34Providing 20 watt retrofit LED tube for replacement as required. (NABL certified as per specification)
35Providing for replacement of Metalik box type batten fixture suitable for fixing of 18 to 22 watt LED tube rod with provision of conduit entry at side and top etc. as required. (NABL certified as per specification)
36LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
3750 Watt
38150 Watt
39LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
4045 Watt
4170/72 Watt
42Supplying / Installation / Testing / Commissioning of Pressure Die Cast Aluminum body of following watt LED well glasse having IK10 impact resistivity and 5KV inbuilt surge protection with high efficacy of greater than or equal to 140 lumens / watt fitting with control gear housing, IP 66 Protection with heat resistance glass eye bolt provided for mounting purpose & wire guard t etc. as required of make of reputed brand under MII confirming to IS and IEC codes on the platform of godown truss/ truss of the shed blocks as directed by the Engineer incharge with M. S. clamps wiring with 3 x 1.5 Sq mm PVC insulated / WP flexible copper conductor wire, painting the clamps including connections and dismantling the existing fittings etc. as reqd. Ref.
4335/36 Watt
4470/72 Watt
45Sub Head III - Repairs of Water Pump :Repairs and maintenance existing submersible tube well water pump including lifting from the existing bore well & re-installation/ refixing details are given as given below :
46Lifting & lowering the existing submersible water pump along with pipe line from bore well including G.I./PVC Pipe Line, Valves etc. as required.
47Rewinding of submersible / monoblock / monosubmersible water pump including credit the damage wire.
48Replacement of required accessories i.e. bearing, bush, etc. in submersible motor pump set.
49Supply of following sizes PVC insulated and PVC sheathed multy strand copper conductor 1100 V grade submersible flat cable with provision of water tight joint as req. : 3 core x 2.5 sqmm
50Sub Head IV - Credit to estimate : The items are to be dismantaled during the execution of work and items lying obsolete in the godown are to be take away by the giving the credit to the estimate as in where as basis.
51Conduit Pipe, old Panel Board, MS clamp, Iron material etc
52Aluminium cables etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56353080
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 43.41 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Annual Repairs & Maintenance Of Electrical Installations At Fsd Balaghat (Navegoan), Balaghat (Kosmi), Jabalpur, Seoni, Katni, Katangi And Waraseoni Under District Office Jabalpur.
Basic Detail
Tender No 05/2026-27
Bidding Type Tender
Location
City Jabalpur
State Madhya Pradesh
Key Dates
Publish Date 07 Jul 2026
Submission Date 20 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 43.41 Lakhs
Tender Fee Ref. Documents
EMD 86850
Exemption Not Available
Document List
2500a9af-b6fe-4afe-83ca-a72d61d1e190.html
BOQ_963002.xls
mtf.pdf
Tendernotice_1 (3).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

2500a9af-b6fe-4afe-83ca-a72d61d1e190.html

xls

BOQ_963002.xls

pdf

mtf.pdf

pdf

Tendernotice_1 (3).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders