Tender For Purchase Of Electronics And Communication Lab Equipments
Tender Overview
Project Description
Tender for Purchase Of Electronics And Communication Lab Equipments , Dth Trainer Kit Power Supply: • 200 V To 240 V Ac, 50 Hz. Dish Antenna: • 1.5 Ft Aluminium Steerable Dish Antenna. Lnb (Low Noise Block Down Converter): • Input Frequency: Ku -Band. • Output Frequency: 950 Mhz To 1450 Mhz. • Conversion Gain: 65 Db. • Noise Temperature: 35 K (Max ) Set -Top Box Receiver In Trainer Form: • If Frequency: 70 Mhz. • Video Bandwidth: 50 Hz To 5 Mhz. • Video Output Level: 1 Vpp At 75 Ω Load. • Video Polarity: Normal/Inverted, Switch Selectable. Audio Subcarrier Frequency: Tunable From 5.0 Mhz To 8.0 Mhz. • Remote Control Provided. • Hdmi Cable: 10 M. Controls: • Channel Selection. • Volume Control. Fault Simulation: • Five Built -In Simulated Faults For Troubleshooting Experiments. • If Signal Disconnected. • Video Output Fault. • Audio Mute Fault. • Tuner Misalignment. • Rf Output Interruption. Pcb Size: • 15 × 12 With Multicolour Section -Wise Block Diagram. Standard Accessories: • 1.5 Ft Dish Antenna. • Lnb. • Trainer Pcb. • Dish Connecting Wire. • Audio -Video Cable. • User Manual. • Acrylic Cover. • Hardware Materials For Assembly Of Dish Antenna. Additional Features: • Dth Subscription Connection With Doordarshan Free Channels. • Free -To -Air Channel Demonstration. , Dc Voltmeter Analog - Moving Coil - (0-30)V, Class 1.0 (±1 % Full-Scale) Accuracy , Dc Digital Voltmeter - 3½ Digit Led/Lcd Display, Measurement Range: 0-20 V Dc, Accuracy: Class 0.5(±0.5 % Full-Scale) , Dc Ammeter Analog - Moving Coil - (0-100) Ma, Class 1.0 (±1 % Full-Scale) Accuracy , Dc Ammeter Analog - Moving Coil - (0 -500) Ma, Class 1.0 (±1 % Full-Scale) Accuracy , Dc Ammeter Analog - Moving Coil - (0 - 1000) Μa, Class 1.0 (±1 % Full-Scale) Accuracy , Dc Ammeter Digital - 3½ Digit Led/Lcd Display, Measurement Range: 0-5 A Dc, Accuracy: Class 0.5 (±0.5 % Full-Scale) , Decade Capacitance Box • Range: 100 providing fixing To 100 Μf • Rotary Switch Selection With 6 Dials. • Maximum Voltage: 350 V. • Accuracy: ±1%. , Decade Inductance Box • Range: 10 Μh To 10 H. • Rotary Switch Selection With 6 Dials. • Low-Loss Inductors. • Accuracy: ±1%. , Sim Reader Trainer Kit Power Supply: • Operates On 230 V Ac ±10%, 50 Hz Mains Supply. • Built -In Regulated Smps Power Supply. • Operating Dc Supply: 5 V / 12 V With Overload And Short -Circuit Protection. Sim Card Interface: • Supports Gsm Sim Cards Compatible With 2G / 3G / 4G / 5G Networks. • Sim Card Read/Write Interface. • Supports Sim Card Initialization, Authentication, And Communication Functions. • Compatible With Standard 6 -Pin / 8 -Pin Sim Card Sockets. Communication Interface: • Usb 2.0 Interface For Pc Communication. • Rs -232 Serial Communication Interface. • Uart Communication Facility For Embedded System Interfacing. Sim Operating Parameters: • Selectable Sim Clock Frequencies: • 3.579 Mhz • 7.159 Mhz • 14.318 Mhz • Sim Supply Voltage Selection Facility. • Sim Reset And Activation Control. Supported Protocols And Standards: • Gsm Etsi 07.07 And Etsi 07.05 At Command Support. • Iso/Iec 7816 Smart Card Communication Support. • Sim Communication Command Monitoring Facility. Hardware Features: • On -Board Sim Card Socket. • Led Indication For: • Power Status • Sim Detection • Reset Activity • Data Transmission/Reception • Built -In Keypad For Standalone Operation. • Lcd Display Module (128 × 64) For Menu And Status Display. • On -Board Microcontroller -Based Control Section. Software Support: • At Command Execution And Monitoring Software. • Sim Manager Utility Software. • Data Logging And Communication Terminal Utility. • Pc -Based Gui Software For Sim Data Communication Experiments. Trainer Features: • Fault Simulation Facility For Troubleshooting Experiments. • Simulation Of Faults Such As: • Sim Not Detected • Clock Failure • Vcc Failure • Reset Failure • Multiple On -Board Test Points For Signal Observation. • Test Points For: • Sim_Rst • Sim_Clk • Sim_Io • Vcc • Uart Tx/Rx • Suitable For Cro/Dso Signal Monitoring. • Glass Epoxy Pcb With Educational Block Diagram Layout. • Compact Tabletop Enclosed Cabinet Design. Construction: • Front Panel With Printed Block Diagram. • Banana Test Points And Patching Facility. Standard Accessories: • Gsm Sim Trainer Unit. • Usb Communication Cable. • Rs -232 Communication Cable. • Power Cord. • User Manual. • Utility Software Cd / Downloadable Software Package.
BOQ
| Sl. No. | Item Description |
| 1 | DTH Trainer kitPower Supply: • 200 V to 240 V ac, 50 Hz. Dish Antenna: • 1.5 ft aluminium steerable dish antenna.LNB (Low Noise Block Down Converter):• Input frequency: Ku -band. • Output frequency: 950 MHz to 1450 MHz. • Conversion gain: 65 dB. • Noise temperature: 35 K (max )Set -Top Box Receiver in Trainer Form: • IF frequency: 70 MHz. • Video bandwidth: 50 Hz to 5 MHz. • Video output level: 1 Vpp at 75 Ω load. • Video polarity: Normal/Inverted, switch selectable.Audio subcarrier frequency: Tunable from 5.0 MHz to 8.0 MHz.• Remote control provided. • HDMI cable: 10 m. Controls: • Channel selection. • Volume control.Fault Simulation:• Five built -in simulated faults for troubleshooting experiments. • IF signal disconnected. • Video output fault. • Audio mute fault. • Tuner misalignment.• RF output interruption.PCB Size:• 15\\" × 12\\" with multicolour section -wise block diagram.Standard Accessories: • 1.5 ft dish antenna.• LNB. • Trainer PCB. • Dish connecting wire. • Audio -video cable. • User manual. • Acrylic cover.• Hardware materials for assembly of dish antenna. Additional Features: • DTH subscription connection with Doordarshan free channels.• Free -to -air channel demonstration. |
| 2 | DC Voltmeter ANALOG - Moving coil - (0-30)V, Class 1.0 (±1 % full-scale) accuracy |
| 3 | DC Digital Voltmeter - 3½ digit LED/LCD display, Measurement range: 0–20 V dc, Accuracy: Class 0.5(±0.5 % full-scale) |
| 4 | DC Ammeter ANALOG – Moving coil - (0-100) mA, Class 1.0 (±1 % full-scale) accuracy |
| 5 | DC Ammeter Analog - Moving coil - (0 -500) mA, Class 1.0 (±1 % full-scale) accuracy |
| 6 | DC Ammeter Analog - Moving coil - (0 - 1000) μA, Class 1.0 (±1 % full-scale) accuracy |
| 7 | DC Ammeter DIGITAL - 3½ digit LED/LCD display, Measurement range: 0–5 A dc, Accuracy: Class 0.5 (±0.5 % full-scale) |
| 8 | Decade Capacitance Box• Range: 100 pF to 100 μF • Rotary switch selection with 6 dials.• Maximum voltage: 350 V.• Accuracy: ±1%. |
| 9 | Decade Inductance Box• Range: 10 µH to 10 H. • Rotary switch selection with 6 dials. • Low-loss inductors.• Accuracy: ±1%. |
| 10 | SIM Reader Trainer kitPower Supply: • Operates on 230 V ac ±10%, 50 Hz mains supply.• Built -in regulated SMPS power supply.• Operating DC supply: 5 V / 12 V with overload and short -circuit protection. SIM Card Interface: • Supports GSM SIM cards compatible with 2G / 3G / 4G / 5G networks. • SIM card read/write interface. • Supports SIM card initialization, authentication, and communication functions. • Compatible with standard 6 -pin / 8 -pin SIM card sockets. Communication Interface:• USB 2.0 interface for PC communication.• RS -232 serial communication interface. • UART communication facility for embedded system interfacing. SIM Operating Parameters:• Selectable SIM clock frequencies: • 3.579 MHz • 7.159 MHz• 14.318 MHz • SIM supply voltage selection facility.• SIM reset and activation control. Supported Protocols and Standards:• GSM ETSI 07.07 and ETSI 07.05 AT command support. • ISO/IEC 7816 smart card communication support. • SIM communication command monitoring facility. Hardware Features:• On -board SIM card socket. • LED indication for:• Power status • SIM detection • Reset activity • Data transmission/reception • Built -in keypad for standalone operation. • LCD display module (128 × 64) for menu and status display. • On -board microcontroller -based control section. Software Support: • AT command execution and monitoring software. • SIM manager utility software. • Data logging and communication terminal utility. • PC -based GUI software for SIM data communication experiments. Trainer Features: • Fault simulation facility for troubleshooting experiments. • Simulation of faults such as: • SIM not detected • Clock failure • VCC failure • Reset failure • Multiple on -board test points for signal observation.• Test points for: • SIM_RST • SIM_CLK • SIM_IO • VCC • UART TX/RX • Suitable for CRO/DSO signal monitoring.• Glass epoxy PCB with educational block diagram layout. • Compact tabletop enclosed cabinet design. Construction: • Front panel with printed block diagram. • Banana test points and patching facility. Standard Accessories: • GSM SIM trainer unit.• USB communication cable. • RS -232 communication cable.• Power cord.• User manual. • Utility software CD / downloadable software package. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender