Tender For Construction Of Mini Community Sanitary Complex Near Pums (Type-I Common) At V.Kumaramangalam Panchayat In Kammapuram Block Cuddalore District.
Tender Value
5.92 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
8 days left
EMD
5920
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuddalore → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Mini Community Sanitary Complex Near Pums (Type-I Common) At V.Kumaramangalam Panchayat In Kammapuram Block Cuddalore District.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work excavation and depositing on bank with initial lead and lift in hard gravelly soil, hard stiff clay, black cotton soil, hard red earth,shales, murram, and earth muds with 50% fair sized boulders as per SS 20B for narrow foundation. |
| 2 | Filling with river M-Sand including cost and coveyance of all materials to work site and all labour charges etc. |
| 3 | Cement Concrete 1:4:8 mix using 40mm metal including cost and conveyanceof all materials to work site and all labour charges etc. |
| 4 | Supplying and errecting for sides & soffits including supports and strutting upto 3.29m height for plane surface in all floors including cost and conveyance and all labour charges etc. Below Basement. |
| 5 | Supplying and errecting for sides & soffits including supports and strutting upto 3.29m height for plane surface in all floors including cost and conveyance and all labour charges etc. Above Basement. |
| 6 | Brick work in cement mortar 1:5 mix using country bricks including cost and conveyance of all materials to site and all labour charges etc complete Upto basement |
| 7 | Brick work in cement mortar 1:5 mix using country bricks including cost and conveyance of all materials to site and all labour charges etc complete Above basement |
| 8 | RCC 1:1.5:3 mix using 20mm metal including cost and conveyance and all labour charges etc.Upto Basement |
| 9 | RCC 1:1.5:3 mix using 20mm metal including cost and conveyance and all labour charges etc.Above Basement |
| 10 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 11 | Plastering with cement mortar 1:5, 12mm thick including cost and conveyance and all labour charges etc. |
| 12 | ReFilling with including cost and coveyance of all materials to work site and all labour charges etc. |
| 13 | Supplying WPC Door D1 of size 0.75m x 2.10m as per standard specification. |
| 14 | Supplying WPC Door SD of size 1.20m x 2.10m as per standard specification. |
| 15 | Supplying RCC Jolly of size 0.60m x 0.45m |
| 16 | Supplying Water Closet IWC |
| 17 | Supplying Water Closet EWC |
| 18 | Fixing Doors (Labour Charge) |
| 19 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone M.Sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)20MM THICK |
| 20 | Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface, chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent and as directed. |
| 21 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work |
| 22 | Roof top Finish with Granolthic pattern using cc 1:2:4 mix 10-12 mm chips 50mm thick using water proofing admixture including cost and conveyance of all charges etc |
| 23 | Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification |
| 24 | Plastering with Cement Mortar 1:5 (One Cement and Three Plastering M.Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers. |
| 25 | Paving the floor with special type of flooring tiles (Cement based Hydraulically pressed Anti skid tiles (20mm thick) in CM 1:3, 20mm thick |
| 26 | Dadooing walls Plain Galzed tiles of size 150x150x6mm including cost and conveyance of all charges etc |
| 27 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. |
| 28 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 29 | Cost, supply and fixing of Precast RCC Ring, including all cost and Labour charges etc., complete. |
| 30 | Cost, supply and fixing of Precast RCC Round slab, including all cost and Labour charges etc., complete. |
| 31 | 110mm dia PVC pipe |
| 32 | 110mm PVC Door Bend |
| 33 | 110mm PVC TEE |
| 34 | 2000 Lit HDPE tank |
| 35 | Brass screw down tap - 15mm dia(M-0508) |
| 36 | Painting Name Board |
| 37 | 20 MM Pvc pipe( M-0875) |
| 38 | 25 MM Pvc pipe( M-0876) |
| 39 | 25 MM TEE (M-0900) |
| 40 | 20 MM TEE(M-0899) |
| 41 | 20 MM BEND(M-0893) |
| 42 | 25 MM BEND(M-0894) |
| 43 | 20 MM ELBO (M-0887) |
| 44 | 25 MM ELBO(M-0888) |
| 45 | 20 MM COUPLER (M-0884) |
| 46 | 25 MM COUPLER(M-0882) |
| 47 | Shellac(M-0518) |
| 48 | Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu.conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for concealed PVC light/ fan point (SD No.25) |
| 49 | Supply and fixing of water tight Bulk Head fitting with guard (Philips / Bajaj / Crompton / Klite) suitable for incandencent lamp and 60W bulb (SD N0.83) |
| 50 | Supply and run of 2 of 1.50 Sq.mm polythene insulated PVC sheathed heavy duty SC Copper conductor of 1100 V grade on 7/20 GI bearer wire for service connection mains (SD No.64) |
| 51 | Supply and fixing of TNEB meter Board suitable for 32A Single Phase service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1\\" x 1/8\\" Copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1\\" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit. (SD No. 125) |
| 52 | Supply and run of 2x4 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains SD 70 |
| 53 | Provision for EB Deposit Charges Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender