Tender for Establishment Of Hindlabs Diagnostic Laboratory At Bangalore
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Jul-2026 | SITE VISIT REGARDING | Technical Bid | 15-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Dismantling & Demolishing |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 4 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below |
| 5 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 6 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. |
| 7 | Dismantling of wash basin/ Sink, closing the pipeline with end cap if necessary, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 9 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | RCC WORK |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending,lacing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 20 | STEEL WORK |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 22 | Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS : 14862, with suitable screws for fibre cement board as false ceiling, side covering, work slab support etc. complete (frame work to be paid separately) :6 mm thick cement board |
| 23 | MASONRY WORK |
| 24 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 25 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 26 | PLASTERING |
| 27 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 28 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 29 | DOORS & WINDOWS |
| 30 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm |
| 31 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmm |
| 32 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper |
| 33 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete. |
| 34 | Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make-MAC/VISTA/NOVA or any equivalent make. |
| 35 | Providing and fixing panelling or Providing and fixing panelled or Making Shelf, Racks, Tables, etc (Area of opening for panel excluding portion inside grooves or rebates to be measured): Marine Ply wood , 18 mm thick with laminated Finish. |
| 36 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick |
| 37 | Providing and fixing powder coated telescopic drawer channels(pair) 300 mm long with necessary screws etc. complete as per directions of Engineerin-charge. |
| 38 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 50 mm. |
| 39 | Providing and fixing magnetic catcher of approved quality in cupboard /ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type. |
| 40 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm |
| 41 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hingesfixed to the frame complete as per manufacturer’s specification and direction of Engineer- incharge Extruded section profile size 48x40 mm |
| 42 | Providing and fixing to existing door frames. 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow sectionof size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 43 | ALUMINIUM WORK |
| 44 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 45 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 46 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 47 | Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness. |
| 48 | Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete |
| 49 | Providing and fixing frosted film in the fixed glass etc. Complete as per the direction of departmental officers |
| 50 | FALSE CEILING |
| 51 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 112.5 mm thick tapered edge gypsum moisture resistant board |
| 52 | WALL TILE |
| 53 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. completeSize of Tile 1000x1000 mm |
| 54 | FLOORING |
| 55 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1000x1000 mm |
| 56 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joint treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. Area of slab over 0.50 sqm |
| 57 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 58 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 1000x1000 mm |
| 59 | PAINTING |
| 60 | Providing and applying white cement based putty of average thickness 1 mm, of approvedbrand and manufacturer, over the plastered wall surface to prepare the surface even andsmooth complete. |
| 61 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 62 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 63 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 64 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 65 | PLUMBING & SANITARY FITTINGS |
| 66 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall |
| 67 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 68 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed/ Concealed on wall |
| 69 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore |
| 70 | Providing and fixing Polypropylene laboratory sink with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : 20.9 x 15.3 x 11.1 inches; 2.26 Kg. |
| 71 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore |
| 72 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes |
| 73 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes |
| 74 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 75 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 76 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 78 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms |
| 79 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe 40 mm dia |
| 80 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms. |
| 81 | Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore |
| 82 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid |
| 83 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 84 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 85 | Providing and fixing PTMT grating of approved quality and colour. Circular type100 mm nominal dia |
| 86 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 87 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 88 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 89 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee |
| 90 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 91 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm Dia Y |
| 92 | Providing and fixing PPR Unions- PPR Union 110mm |
| 93 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 94 | SIGNAGES |
| 95 | Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 16\\" x 10\\". Complete as per the per the direction of Engineer in charge. |
| 96 | NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design, Supplying and fixing Name Board as per the technical specifications given -1 Inch GI pipe frame (16Guage) for Frame (Size proportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets (Aluminum Composite Panel) for Box area, 18mm thick Multi wood Lettering for Name Board as approved by Engineer in charge. For Measurement purpose, only area of ACP sheet to be measured |
| 97 | FURNITURES |
| 98 | Providing & Fixing mid back chair with ergonomic revolving chair with five-star nylon base, 50 mm dia. nylon twin-wheel castors, pneumatic gas-lift height adjustment, back-angle adjustment, 2 D adjustable armrests, PU-moulded foam seat, mesh backrest, and heavy-duty rubber-backed fabric upholstery in Black, complete as per standard specifications and as directed by the Engineer-in-Charge. |
| 99 | Providing & Fixing table of size 5.58 ft X 2.5ft made up of 18mm particle board with lamination on both sides. Side partitions, drawers, racks, lock and laches etc including all complete both side laminated top. with 18 mm thick door and 9 mm thick both side laminated drawer bottom and back panel including necessary approved hinge, telescopic slide ,multipurpose lock ,hanger rod of 25mm dia 16 gauge nickel plated MS Pipe ,2nos. tower bolt of barrel type having size 150 x 10mm, 4 nos. magnetic catcher triple strip vertical type of approved quality, 128 mm handle , kd/minifix fitting, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand fixture and finishing etc.. complete job. as per approved shade and colour and as per Architecture drawing and Engineer in Charge. . |
| 100 | Supply of SS Revolving Stool with 100 Kg Capacity of 300mm seat dia, Height adjustable 450mm to 680mm. 3 legs tubular base, Revolving top, Legs fitted with shoes 16 & 18 Guage Pipe, 1Mm Sheet. |
| 101 | Providing & Fixing 3 seater stainless steel chair. Silver colour with seating capacity 3 SS 201 grade (or better) steel perforated seat sheet and back rest and arm rest. Suitable for heavy public use. Should be ISO certified manufacturer. Width of seat 52cm to 55cm, height from ground 79cm. |
| 102 | Providing, fabricating, supplying and installing Slotted Angle Storage Racks made from high-quality mild steel slotted angles of minimum 2.0 mm thickness, conforming to standard storage rack specifications. The vertical members shall be formed from slotted MS angles of size 40 mm × 40 mm × 2 mm or equivalent, with uniformly punched slots at regular intervals to facilitate adjustable shelving. The racks shall be provided with horizontal tie members and bracings made from MS flat/angle sections to ensure structural rigidity and load stability. Shelves shall be fabricated from 18 gauge (1.2 mm thick) mild steel sheet with folded edges on all sides for strength and safety. Each shelf shall be adjustable at suitable intervals and capable of carrying a uniformly distributed load of minimum 80–100 kg per shelf. All components shall undergo surface preparation including cleaning and phosphating, followed by Epoxy Polyester Powder Coating of minimum 60–70 microns thickness in approved colour to ensure corrosion resistance and durability. The rack shall typically consist of 5 adjustable shelves, overall height 2000 mm, depth 450–600 mm, and length 900–1200 mm, assembled with high tensile nuts and bolts complete in all respects as per approved layout and site requirements. The work shall include supply, installation, alignment and fixing of racks with all necessary accessories and hardware for proper installation. Approved Make: Godrej / Ezy Rack / or equivalent approved make. |
| 103 | WORKSTATION |
| 104 | Providing, fabricating, supplying and installing Laboratory Modular Work Table fabricated from 1.2 mm thick Electro-Galvanized Iron (EGI) sheet with 120 GSM zinc coating, wrinkle-free and double skin pass, using steel from TATA / POSCO / Jindal or equivalent approved make. All metal components shall undergo an 8-tank surface pretreatment process followed by Epoxy Polyester Powder Coating of 70–80 microns thickness applied through a conveyor operated automated powder coating system to ensure high resistance to corrosion, chemicals and abrasion for both internal and external surfaces. The work table shall be provided with modular cabinets of standard width of 750 mm to 900 mm and height 775 mm for instrument tables or 875 mm for wet chemistry tables. Doors and drawer front panels shall be of double wall sound-deadening sandwich construction. The worktop shall be 16 mm thick chemical resistant laboratory grade surface manufactured using Electron Beam Cured technology, free from melamine and conforming to SEFA 3.0 chemical resistance standards, preferred make Trespa or equivalent, OR 18 (+1) mm thick mirror polished jet black granite with half round bullnose edge finishing on exposed sides. Provision of reagent racks with stainless steel rods and 10 mm thick toughened glass shelves: 150 mm wall-side two-tier rack, 300 mm double side two tier rack. The racks shall be adjustable and the glass shelves removable for cleaning and maintenance. The workstation shall be complete with SS 304 five-knuckle hinges (SEFA approved) and powder coated soft closing drawer slides with minimum 30 kg load capacity, make Hettich / Häfele / Ebco, and recessed aluminium handles with epoxy powder coated or brushed aluminium finish, including all electrical LAN, Plumbing and other necessary accessories, fixtures and fittings for complete installation as per approved drawings and site requirements. |
| 105 | Providing, fabricating, supplying and installing Laboratory Overhead Cabinets fabricated from 1.2 mm thick Electro-Galvanized Iron (EGI) sheet with 120 GSM zinc coating, wrinkle-free and double skin pass, using steel from TATA / POSCO / Jindal or equivalent approved make. All metal components shall undergo an 8-tank surface pretreatment process followed by Epoxy Polyester Powder Coating of 70–80 microns thickness applied through a conveyor operated automated powder coating system to ensure resistance to corrosion, chemicals and abrasion for both internal and external surfaces. The cabinets shall be wall mounted modular units with standard width of 350mm and height 450 - 600 mm suitable for laboratory storage above work benches.Doors shall be double wall construction with sound deadening sandwich design and shall be provided with toughened glass viewing panels (where specified) to allow visibility of stored materials. Internal shelves shall be fabricated from EGI sheet with epoxy polyester powder coating and shall be adjustable for height.The cabinet shall be complete with SEFA approved SS 304 five-knuckle hinges, soft closing mechanism, and recessed aluminium handles with epoxy powder coating or brushed aluminium finish, make Hettich / Häfele / Ebco or equivalent approved. The overhead cabinets shall be securely mounted to wall or structural support using suitable heavy duty brackets and anchor fasteners, complete with all accessories, fixtures and fittings required for proper installation as per approved drawings and site requirements. |
| 106 | ELECTRICAL WORK |
| 107 | Point wiring in PVC conduit with modular type switch: |
| 108 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B |
| 109 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 110 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 111 | Wiring through PVC conduit: |
| 112 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 113 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 114 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 115 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 116 | S/F PVC Conduit: |
| 117 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 118 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 119 | Modular boxes, bases & cover plate: |
| 120 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 121 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 122 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 123 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface |
| 124 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module |
| 125 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 3 module moulded plastic box on surface |
| 126 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module |
| 127 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 6 module moulded plastic box on surface |
| 128 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 129 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 130 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 131 | Modular type switch/socket: |
| 132 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 133 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 134 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 135 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 136 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 137 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 138 | DB Accessories: |
| 139 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 140 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way (4 + 18), Double door |
| 141 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 4 way (4 + 12), Double door |
| 142 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 100 A,30KA,FPMCCB |
| 143 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 30mA. |
| 144 | Supplying and fixing 40A / 63A, TP MCB, 415 Volts, \\"C\\" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 145 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 146 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 147 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 148 | Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 149 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 150 | EARTHING: |
| 151 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 152 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 153 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 154 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 10 SWG) |
| 155 | SUPPLY AND LAYING OF LT CABLES: |
| 156 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 157 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 158 | LT CABLE TERMINATION: |
| 159 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35mm) |
| 160 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 161 | CABLE TRAYS |
| 162 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 163 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 164 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Tee\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 165 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"Cross member\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness |
| 166 | LIGHT FITTINGS & FANS: |
| 167 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operatingvoltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum powerconsumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not riseabove 90°C).Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) 36 watt |
| 168 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim Powder coated die cast /Extruded aluminium Body including trim .18 watt |
| 169 | SITC of 30 Watts Ip-65 Bis Approved Waterproof Rectangular Outdoor Arm Light,Shape Rectangular.Material-Aluminium,Finish Type-Powder Coated,,IP65 Rating (Waterproof), CRI : >80%, Premium quality, LED : 100-120lm/w, CCT - 6000-6500K (Cool White) |
| 170 | Supplying and fixing of required length 32 mm dia G.I. Pipe (light class) including painting etc. as required. |
| 171 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 172 | SITC of 450mm sweep Wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation. |
| 173 | SITC of 250mm sweep Exhaust Fan, 900rpm light duty exhaust fan shutter type white colour, 9\\" or 10\\" star rated as per BEE, with its all accessories including mounting as required for complete installation. |
| 174 | DISMANTLING |
| 175 | Electrical Labour works for dismantling of existing ceiling fan, light fittings, Switch Boards, DB Boards (SPN &TPN) using mechanical means or physical means without disturbing the overall structure of proposed area. All items dismantled and shall be made a checklist for returning back to concerned Authorities. All items shall be verified by Electrical Engineer (HLL) before handing over. If any working product is damaged during transit, the same shall be replaced without any additional claim. |
| 176 | Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance,protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature: STS, Inverter, PFC. g) EventLogging & Statistical Data (On LCD/LED): UPSshould capture and display up to 3000 events like:Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j)Audible Alarms : Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 10KVA (Each Power module shall be < 10 KVA) |
| 177 | CCTV: |
| 178 | Supplying Installation Testing and Commissioning of 2MP IP IR Dome Camera having followingspecifications, type of lens and features etc :-1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date &Time in live & recorded video2)Image Sensor: 1/2.8\\" or better progressive ScanCMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120db or more)5) Digital Noise Reduction:- DNR (3D) On/Off6) Video Streaming & Frame Rates :- Triple streaming, configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:720P@25/30 fps).7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client softwareor web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, videoencryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted boot.9) Onboard Storage: Camera should support built-inMicro SD/SDHC/SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard.280 10) Recording Management: Format SD, overwrite, storage management, video to NAS device 11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast13) System Capability: ONVIF, Camera shall supportopen source VMS14) Ethernet: 1 RJ 45 10/100 Ethernet port15) Audio : It should support 1 x Built-In Mic and 1/1Alarm In/ Out for External Mic. and Speakers as persite requirement.16) Power Input: The camera should supportsimultaneous dual power input—12 VDC (via poweradapter) and PoE (802.3af)—to ensure continuousoperation in the event of a failure in one power source.17) Power Requirement: 12VDC/24 VAC/PoE(802.3af)/ePoE18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens |
| 179 | SITC Of Finolex co-axial 3+1 Copper CCTV Cable with more than 100% conductivity,with low signal loss, sharp picture & clear sound. In-House formulated & manufactured special grade FR PVC compound. (Brand Finolex) |
| 180 | 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 |
| 181 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 182 | SITC Of 16 Channel Power Supply with Input of 200-240VAC 50-60Hz, 3.5A Max and Output Voltage 12VDC 20A with metal Housing Desktop/Wall Hanging |
| 183 | SITC OF 4U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key. |
| 184 | DC Connector Screw Type |
| 185 | NETWORK: |
| 186 | Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/ULverification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 187 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable |
| 188 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required. |
| 189 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm ToughenedGlass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U rack |
| 190 | Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink |
| 191 | TELEPHONE |
| 192 | Supply of User Phone- Analog phone |
| 193 | SITC of EPABX System of 8 lines extendable to 16 lines, No. of Junctions – 2, Console Operator – 1, ISDN Compatible. Extendable to 16 intercom connections; Internal/External Music on Holding, Operator/Auto-attendant Mode, Remote Programming. Day/Night Mode (Manual), Music and Ringing Recordable OGM (Outgoing Message), Music Duration 20 Seconds. Caller ID, Call Transfer, Call Forwarding Manually, Outgoing Call Transfer, Power Failure Transfer, Specific Main Line (CO/Trunk Line) Dialing, Three Way Conference, Do Not Disturb, Auto/Manual Dial-Out Mode. Type: Digital / Analog Temperature Range: 0°C to 50°C Operating Humidity: 0–95%, Non-Condensing. |
| 194 | Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 195 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 196 | DOCUMENTATION AND APPROVAL: |
| 197 | DOCUMENTATION AND APPROVAL - \\"Charges for Preparation of all drawings submitting and getting approval from EB, submitting of Completion certificates and arranging inspection, getting sanction from EB, obtaining power allocation if necessary & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts |
| 198 | Reverse Osmosis (RO) Water Treatment Plant |
| 199 | Supply, Installation and Commissioning of Reverse Osmosis Water treatment plan with purification Capacity of 500 LPH, including the following specifications. 1.Raw Water Pump: 1000LPH Horizontal Centrifugal 0.5HP ,2.FRP Dual Media Filter: Graded silex, Quartz Sand and Premium anthracite, 3.FRP Carbon Filter: Pebbles, Quartz Sand and Activated carbon of IV1050.,4.Dosing System: 5LPH, 4 Bar ,5.Reverse Osmosis Membrane: Spiral Wound Type Membrane, 60% max recovery ,6.Micron Filter: Wound Type Membrane, 0.5 Micron Rating,7.Pressure Tubing System: Positive Horizontal Series 1/2 array, 8.High Pressure Pump: I000LPHV ertical Multistage 2HP ,9.MicroProcessor Control System: TDS Display, Starters and Overload Relay ,10. Instrumentation: Flow Meter, High- and Low-Pressure Switch, Pressure Guage , l l.Plumbing: ASTM pipes (max 5m), NRV release valve as required, 12. SS Base: 304 Stainless Steel 13.Automatic Cut-off Switches: EELEQUA or equivalent make,14. l 000Liter SS Tank: 304 Stainless Steel, 15. l 000Liter HDPE Tank: Sintex or equivalent make, 16. Ultra Violet Disinfection System: 2000LPH, 17.Water Dispensing System: UPVC pipes (max 50in). |
| 200 | HVAC WORKS |
| 201 | HIWALL SPLIT AC |
| 202 | Supply, Installation, Testing and Commissioning of 1.0TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single-phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature).WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier |
| 203 | Supply, Installation, Testing and Commissioning of 2.0TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single-phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature).WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval.Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier |
| 204 | Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short-circuit and surge protection |
| 205 | Supply and installation of automatic voltage STABILIZERS suitable for 2.0TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short-circuit and surge protection |
| 206 | Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in-Charge’s directions, ensuring level alignment with wall/floor mounting options |
| 207 | Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system. |
| 208 | Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling. |
| 209 | Supply Installation Testing and Commissioning of Condensate Drain Pump, with the following parameters - Max. flow 550L/h @ 0 head, Max. rec. head 5m. Single Phase Supply . All inclusive of accessories, wiring etc. necessary for fixing of the unit |
| 210 | FIRE ALARM |
| 211 | FIRE ALARM SYSTEM |
| 212 | Supplying, installation, testing & commissioning of smoke etector with builtin LED and mounting base complete with all connections etc. as required. |
| 213 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 214 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 215 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 Zone |
| 216 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 217 | SITC OF ISI marked (IS:2878) fire extinguisher CO2 type capacity 4.5kg. Flat base including valve, discharge hose of not less than 10mm dia , 1 meter long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1996 filled to filling rate of not more than 0.667 and wall bracket (fixed with anchor Fastner) or floor mounted Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 09, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Jul 15, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender