Tender For Running Maintenance Of Rws/Jjm Schemes Under 15Th Finance Commission (Tied) Fund Within The Jurisdiction Of Bilashcherra Gp Under Durga Chowmuhani Block During The Year 2026-27/ Sh:- Running maintenance Of Pipeline Leakage, Blockage, Lower
Tender Overview
Project Description
Tender for Running Maintenance Of Rws/Jjm Schemes Under 15Th Finance Commission (Tied) Fund Within The Jurisdiction Of Bilashcherra Gp Under Durga Chowmuhani Block During The Year 2026-27/ Sh:- Running maintenance Of Pipeline Leakage, Blockage, Lowering, Lifting & Rewinding Of Burnt Pump-Motor Sets, Column Pipes Repair & Replace Of Starter, Mainswitch & Other Allied Works Under Dws Sub-Division Kamalpur.
BOQ
| Sl. No. | Item Description |
| 1 | Charges for repairing of leakages in UPVC/ HDPE pipe line with PVC coupler & solvent cement etc. in/c necessary earth excavation, backfilling of soil as required after laying of pipeline in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming, watering etc. complete as per specification & direction of the Engineer-in-charge. |
| 2 | i) 90 mm dia |
| 3 | ii) 110 mm dia |
| 4 | iii)140 mm dia |
| 5 | Lifting of summerssible pump motor with delivery assembly by heavy duty chain pullry after dismantling from delivery line and stacking properly as per direction of the Engineer-in-charge. |
| 6 | Labour charge for fitting fixing and laying of submerssible pump motor set with delivery assembly 90º to 0º in/c refitting fixing with the delivery line etc as per direction of the Engineer-in-charge. |
| 7 | Labour charge for lifting of 20,000/10,000/5000 GPH capacity water lubricated vertical submersible pump with motor in/c 80ft. Cplumn pipe assimbly by heavy duty chain pully block as per direction of the Engineer-In-Charge. |
| 8 | Labour charge for fitting, fixing & lowering of 20,000/10,000/5000 GPH capacity water lubricated vertical submersible pump with motor in/c 85ft. by heavy duty chain pully block as per direction of the Engineer-In-Charge. |
| 9 | Repair and maintenance of 10 HP / 12.5 HP Motor suitable for 5000 GPH capacity submerssible pumpset by complete dismantling in/c providing and fitting fixing PVC ( IS : 8783-1978 ) insulated electro grade copper (IS: 613-1984) conductor winding in stator & all necessary spare parts and reassembling the same in/c servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge. |
| 10 | Repair and maintenance of submessible Motor suitable for submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specif ication and direction of the Engineer-in-charge.i) 2.0 HP Motor suitable for 2000 GPH capacity submerssible pumpset |
| 11 | Supplying and fitting fixing of single phase motor Starter panel unit capacity Comprise With 2 pole Conductor ,Over load relay ,capacitor ,voltmeter, Ampsmeter, of BCH / L&T make with necessary Copper wire etc. Complete & direction of the Engineer-in-Charge. |
| 12 | Supplying and fitting fixing of 32 Amps single phase main Switch of BCH / Havel's make in/c cost of necessary copper Wire Wiring complete as per direction of the Engineer-in-charge. |
| 13 | Providing and fixing G.I pipes ( Medium class ) as per IS 1239 with latest amendment complete with GI fittings in/c trenching and reffilling , cutting & making good the walls etc. complete as per specification & direction of the Engineer-in-charge. (External work).a) 15 mm dia. nominal bore |
| 14 | b) 40 mm dia. nominal bore |
| 15 | Providing and fitting fixing with PVC insulated 3 core flat Copper cable conforming to relevant IS code for submerssible motor with all necessary equipments and fittings as required as per specif ication and direction of the Engineer-in-charge.i) 2.50 sqmm |
| 16 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 17 | i) 90 mm dia |
| 18 | i) 40 mm dia |
| 19 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge. |
| 20 | i) 150 mm dia. PN - 1.0 |
| 21 | Supplying & fitting fixing of panel box of M.S. sheet with locking arrangement comprise with starter, main Switch, busber Volt Meter selector switch etc. inside the box in/c. service connection within 50.00 mtr. length from LT line with roof for rain water protection and 4(four) nos. stand by c.c. work in all respect as per direction of the Engineer in Charge (excluding the cost of starter and main switch). |
| 22 | Excavating trenches of required width for pipes, cables etc, in/c excavation for sockets, & dressing of sides where required, ramming of bottoms, depth up to 1500 mm(slope-1 in 200) in/c getting out the excavated soil, & backfilling of soil as required, after laying of pipeline, in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming, watering etc. & disposing of surplus excavated soil with all required leads as per chapter - 2 of CPWD specification & direction of the Engineer-in-charge. |
| 23 | A. For UPVC pipes in new work |
| 24 | a. In all kinds of soil |
| 25 | i) For pipes not exceeding 90 mm OD |
| 26 | ii) For pipes exceeding 90 mm dia but notexceeding 300 mm dia |
| 27 | Providing, fixing & laying Rigid UPVC pipes conforming to IS: 4985 jointing with couplers, of same class conforming to IS : 10124(Pt- II) with slovent cement conforming to IS : 14182 in/c. testing of joints complete (But excluding the cost of specials like bends, tees etc. which will be paid saperately as per CPWD specification and direction of the Engineer-In-Charge. |
| 28 | A) Class - 3 (working pressure 6.00kg/ sqcm) |
| 29 | i) 40 mm OD |
| 30 | ii) 90 mm OD |
| 31 | iii) 110 mm OD |
| 32 | iv) 140 mm OD |
| 33 | Removal of Blockage from existing distribution pipe line of all domestic as well as washing by inserting 40mm dia PVC coil pipe upto the length of 30.00 mtr by cutting of pipe at any depth including necessary de-watering whenever required etc. complete as per direction of the Engg-in-charge. (Bitumen road cutting , excavating earth and re-filling the same sand filling cutting and relaying of pipes ,specials in/c lead joints will be paid separately). |
| 34 | Providing and laying of flexible PVC pipe (conforming to IS:7634) complete in/c earth work as per specification and direction of the Engineer - in - charge (cost of fittings will be paid separately). |
| 35 | i) 15 mm dia |
| 36 | Providing and fixing brass ferrule with C.I. cover conforming to IS : 2692 including boring and tapping the main as per CPWD specification and direction of the Engineer - in - charge. |
| 37 | i) 10 mm nominal bore |
| 38 | Providing and fixing U.P.V.C. service saddle as per CPWD specification and direction of the Engineer - in - charge. |
| 39 | i) 40 mm dia with 15 mm dia opening |
| 40 | ii) 90 mm dia with 15 mm dia opening |
| 41 | iii) 110 mm dia with 15 mm dia opening |
| 42 | iv) 140 mm dia with 15 mm dia opening |
| 43 | Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge. |
| 44 | i) 15 mm dia |
| 45 | Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge |
| 46 | i) 15 mm dia |
| 47 | Providing and fixing G.I. Nipple of medium class as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia 75 mm long |
| 48 | Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different location as per specification & direction of the Engineer-in-charge.. i) 15 mm dia PVC /plastic bib cock |
| 49 | Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge. i) 15 mm dia |
| 50 | Providing and fixing in position precast RCC platform of size 900 mm x 900 mm x 100 mm with curb of size 75 x 75 mm kepping an opening of 200 mmwide for surface drain of 60 cm length of size (200 mm x 150 mm )in a suitable place for draining out of grey water (made with cement concrete 1:2:4 ( 1 cement:2 sand :3 graded well brunt brick aggregate 20 mm nominal size ) and steel reinforcement (TMT bars) 6 nos 8 mm dia in both direction including plastering the exposed surface with 6mm thick cement morter 1:3 (1 cement: 3 sand) for platform and 12 mm cement plaster ( 1:4) (1 cement: 4 sand) for surface drain finish with a floating coat of neat cement complete with all earthwork required including refilling etc complete as per approved drawing (Drawing No.-06/CE/ACE/P&DU/DWS/2022-23) , specification and direction of Engineer-in-charge . |
| 51 | Providing and fixing in position precast RCC hydrant post of size 100 mm dia made with reinfored cement concrete 1:2:4( 1 cement :2 sand :4 graded well burnt brick aggregate 1st class 20 mm nominal size ) and steel reinforcement (TMT bars ) 3 nos 8 mm dia 950 mm long and 7 nos 6 mm dia ties including plastering the surface with 6 mm thick cement morter 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement including providing and embedding 15 mm dia G.I. pipe ( medium class as per IS :1239) with necessary G.I. fittings like 2 nos elbow , 1 no socket , 2 nos nipple 225 mm long and fitting fixing of PVC bib cock with G.I. socket with all earthwork required including refilling etc complete as per approved drawing (Drawing No.-06/CE/ACE/P&DU/DWS/2022-23) , specification and direction of Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender