Tender For Running maintenance Of Uws Scheme Under Kamalpur Nagar Panchayet./Sh:- Repair And Maintanance Of The Office Building Of Pwd (Dws) Division, Kamalpur, Dhalai, Tripura During The Year Of 2026-27.
Tender Value
9.43 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
4 days left
EMD
18870
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dhalai → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Running maintenance Of Uws Scheme Under Kamalpur Nagar Panchayet./Sh:- Repair And Maintanance Of The Office Building Of Pwd (Dws) Division, Kamalpur, Dhalai, Tripura During The Year Of 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account). |
| 2 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 3 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 4 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired doorshutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 5 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground with all leads and lifts including finishing even and smooth and curing complete as per direction of the Engineer in charge:-13.30.2) With cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 6 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 7 | Distempering with 1st quality washable acrylic distemper of approved brand and manufacture and of required shade on old work ( one or more coats ), to give an even shade as required complete as per direction of the Engineer in charge. |
| 8 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture on old work ( one or more coats ) including preparation of surface as required complete as per direction of the Engineer in charge. |
| 9 | Painting on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint ( one or more coats) of required colour of approved brand and manufacture to give an even shade on old work over and including preparation of surface as required complete as per direction of the Engineer in charge:- |
| 10 | 75 mm dia. |
| 11 | 100 mm dia. |
| 12 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand andmanufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge.On steel grill |
| 13 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.8.18.2) 30 mm thick including ISI marked Stainless Steel butthinges with necessary screws. |
| 15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.8.46.1 ) Fixed to steel windows by welding. |
| 16 | Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: |
| 17 | 8.93.4) 100x63x4 mm |
| 18 | 8.93.6) 75x63x4 mm |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :8.94.1) 300x16 mm |
| 20 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc.complete : |
| 21 | 8.95.3) 200x10 mm |
| 22 | 8.95.4) 150x10 mm |
| 23 | 8.95.5) 100x10 mm |
| 24 | Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overalldimension, as below (tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frame to be jointed with galvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the frames reinforced by galvanized MS tube of size 19 × 19 mm and 1 mm +/- 0.1 mm wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-Charge.8.114.2) Extruded section Profile size 42x50 mm. |
| 25 | Providing and fixing to existing door frames. |
| 26 | 8.115.1) 24 mm thick factory made PVC door shutters made of styles and rails of a UPVC hollow section of size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised /plastic brackets of size 75×220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserying galvanised MS tube of size 20×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \\"H\\" Section, a UPVC hollow section of size 100×24 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic /galvanised MS \\"U\\" cleats. The shutter frame filled with a UPVC multi-chambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontaly 6 mm galvanised MS rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 27 | Cement concrete flooring 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. all completeetc as per direction of Engineer-in-charge.10.5.1) 40 mm thick with 20 mm nominal size stone aggregate |
| 28 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge.10.42.3) Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid)10.42.3) Size of tile 600 mm x 600 mm |
| 29 | Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge.10.54.1) In dark shade using ordinary cement |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters andpartition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-16.3.1) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 32 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :17.14.1) Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 33 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: |
| 34 | 18.82.1) Single socketed pipe - 75 mm OD |
| 35 | 18.82.2) Single socketed pipe - 110 mm OD |
| 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC soil, waste & vent pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: |
| 37 | Coupler |
| 38 | 75 mm |
| 39 | 110 mm |
| 40 | Single equal tee without door |
| 41 | 75x75x75 mm |
| 42 | 110x110x110mm |
| 43 | Single equal tee with door |
| 44 | 75x75x75 mm |
| 45 | 110x110x110mm |
| 46 | Bend 87.5° |
| 47 | 100mm |
| 48 | Providing and fixing to the inlet mouth of rain waterpipe PTMT grating with thickness of 8mm and weighing not less than 100gm. etc. complete as per direction of Engineer-in-charge.11.58.2) 100 mm |
| 49 | Providing and fixing 25mm x 1.40 mm clips made out of aluminium strip of approved design to unplasticised - PVC soil, waste & vent pipes by means of Plastic Wall Plugs fitted in the brick work/R.C.C work by drilling with the help of mechaine and screwed with M.S. screws of required length and making good the wall etc. complete. |
| 50 | 18.86.1) 75 mm |
| 51 | 18.86.2) 110 mm |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall19.7.1) 15 mm nominal outer dia .Pipes. |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.External work19.9.3) 25 mm nominal outer dia .Pipes. |
| 54 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I.fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge. Internal work - Exposed on wall. |
| 55 | 19.10.1) 15 mm dia. nominal bore |
| 56 | 19.10.3) 25 mm dia. nominal bore |
| 57 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):19.17.1) 25 mm nominal bore |
| 58 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :219.18.3) 5 mm nominal bore |
| 59 | Providing and fixing gun metal non-return valve of approved quality (screwed end):19.19.1) 25 mm nominal bore |
| 60 | 19.19.1.1) Horizontal |
| 61 | 19.19.1.2) Vertical |
| 62 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 markedwith cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 63 | Providing and fixing PTMT bib cock of approved quality and colour.19.54.1) 15mm nominal bore, 86 mm long, weighing not less than 88 gms. |
| 64 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. |
| 65 | 19.75.3) 25 mm nominal bore. Weighing not less than 62 gms. |
| 66 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-5.3.2) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 67 | Centering shuttering including struttings, propping etc. and removal of form work for:5.8.4.1) Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 68 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.19.4) Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 69 | Electrick Work PVC Insulated Copper conductor wiring in PVC casing capping with piano type switch, socket etc.101) Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- |
| 70 | a)Short Point :- |
| 71 | b)Medium Point :- |
| 72 | c)Long Point :- |
| 73 | Providing and fixing of 3 pin 5/6 amps plug point with piano type 5/6 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 74 | Providing and fixing of 3/6 pin15/16 amps plug point with piano type 15/16 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) on switch board, earthing the 3rd pin etc. as required:- |
| 75 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 76 | n) Electronic 5 step fan regulator |
| 77 | r) Angle/batten holder |
| 78 | s) Ceiling rose |
| 79 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 80 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 81 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-a) Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:- |
| 82 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-b) 36 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 83 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-e) 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink : |
| 84 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-c) 63 amps 240 volts DP main switch (rewireable):- Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender