Tender For Special Repairs / Addition And Alteration To Fire Station (Building No P-65) Nstl Under Age (I) R&D Nstl Visakhapatnam
Tender Value
48 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
20 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatanam → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs / Addition And Alteration To Fire Station (Building No P-65) Nstl Under Age (I) R&D Nstl Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm complete all as specified and directed. |
| 2 | M&L for 10 mm thick Vitrified floor tiles in 600mmx600 mm size with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid over and including 20mm thick screed bed in cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc complete all as specified and directed. |
| 3 | M&L for 10 mm thick Vitrified tiles in different sizes, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, as in skirting, riser of steps, laid over and including 12 mm thick plaster in cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 4 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 5 | M&L for 25 mm thick Kota stone slab flooring laid over and including 20 mm thick screed bed in cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete all as specified and directed. |
| 6 | M&L for 20 mm thick Kota stone slabs as in risers of steps, skirting, dado and pillars laid over and including 12 mm thick plaster cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete all as specified and directed. |
| 7 | Taking down existing roof treatment of any description and removing the debris to a distance exceedind 500m and depositing outside MD land complete all as specified and directed. |
| 8 | M&L for Water proofing treatment with PU based treatment as under:- (a) Mechanically cleaning of surface to make it free from any bituminous residue / dirt, oil and Greece etc complete all as specified and directed. (b) Cracks treatment by cutting open cracks and cleaning it from dirt/loose materials etc and filling with polyurethane based sealant with and including application of PU based primer complete all as directed. (c) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same materials after dilution of water at 50% or specific primer matching same materials complete all as specified and directed. |
| 9 | Properties of Polyurethane based chemical shall confirming to following Technical Parameters:-(i) Highly Elastic.(ii) UV Resistance.(iii) Adhesion to concrete.(iv) Tensile strength – not less than 2.0 N /Sq.mm for free film.(v) Elongation – not less than 300%.(vi) Solid content by weight- not less than 60%(vii) Air/water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0 mm.(viii) Accelerated weathering (ASTM453) : Pass 1000 hours. (ix) Reaction to fire – non inflammable. |
| 10 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement, including taking down plastering complete all as specified and directed. |
| 11 | M&L for Rendering 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement, including taking down existing plaster complete all as specified and directed. |
| 12 | M&L for Rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement, including taking down existing plaster, complete all as specified and directed. |
| 13 | M&L for applying 2 mm thick wall care putty on wall surfaces, including preparation of surfaces etc complete all as specified and directed. |
| 14 | M&L for Preparation of new plastered surfaces of ceiling and applying two coats of white wash on new ceiling surfaces complete all as specified and directed. |
| 15 | M&L for preparation of new plastered surfaces of walls and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and directed. |
| 16 | M&L for Complete removal of existing treatment on surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (Two coats applied @ 1.43Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and directed. |
| 17 | M&L for Preparation of new surfaces and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre of approved manufacturer of required shade and colour, complete all as specified and directed. |
| 18 | M&L for complete removal of existing treatment from internal wall, washing, rubbing down and stopping of distempered and painted surfaces applying 2mm thick wall care putty and two coats of 1 st quality distempering (ready mixed) having VOC less than content less than 50 gms/litre required colour shade, complete all as specified and directed. |
| 19 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 Sqm and below complete all as specified and directed. |
| 20 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube complete all as specified and directed. |
| 21 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement and S & F in the frame at site complete all as specified and directed. |
| 22 | S&F for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or iveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and Hold fasts similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 23 | M&L for Preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer, complete all as specified and directed. |
| 24 | S&F Anodised aluminium powder coated frames for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 25 | M&L for Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 26 | S&F Anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mmlong (2 Nos.) suitable handle (1No.) complete all as specified and directed. |
| 27 | S&F Aluminium Sliding door bolts of Size 250mm complete all as specified and directed. |
| 28 | S&F Door closer, of aluminium (die cast) body, hydraulically regulated, designation No 2, universal type, suitable for door shutters of weight upto 60Kg, fixed in repairs complete all as specified and directed. |
| 29 | M&L for 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 30 | S&F Anodised aluminium barrel tower bolt 150mm long complete all as specified and directed. |
| 31 | S&F Aluminum Hooks & eye of size 150mm fixed to window shutter complete all as specified and directed. |
| 32 | Supply only Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed |
| 33 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading in squares not exceeding 0.5 Sqm each pane fixed in aluminium windows/door/partions complete all as specified and directed |
| 34 | Supply and fix 20mm dia anodised aluminium alloy curtain rod with with fixing brackets, stops, rollers etc, complete all as specified and directed. |
| 35 | M&L for Nonskid ceramic coloured tiles 300mm x 300mm x 7mm thick, as in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match laid over and including 20mm thick screed bed in CM(1:4), complete all as specified and directed. |
| 36 | M&L for 1st quality 7mm thick ceramic glazed wall tiles conforming to IS: 15622, of approved make, in all colours, shades except burgundy, bottle green, black of size 300mm x 450mm as approved, as in skirting, risers of steps and dados, laid over and including 12 mm thick bed in cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per sqm, including pointing in white cement mixed with pigment of matching shade, complete all as specified and directed. |
| 37 | M&L for white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern and including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed. |
| 38 | M&L for Wash Basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern and including painting of fittings & brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin of size 550 mm x 400 mm with single 15 mm C.P. brass pillar taps, complete all as specified and directed. |
| 39 | M&L for P.V.C. waste pipe for wash basin including P.V.C. waste fittings complete flexible pipe 32 mm dia complete all as specified and directed. |
| 40 | M&L for CP Brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms of 15mm nominal bore including taking down complete all as specified and directed. |
| 41 | S&F in repairs cast copper alloy, chromium plated 2 way bib cock 15mm dia with crutch handle with wall flange complete all as specified and directed. |
| 42 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making, including taking down complete all as specified and directed. |
| 43 | S&F C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 of 15 mm nominal bore Including Taking Down. |
| 44 | S&F C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of of 15 mm nominal bore including taking down. |
| 45 | S&F PTMT grating of approved quality and colour of 100 mm nominal dia including taking down complete all as specified and directed. |
| 46 | S&F unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length Including Taking Down complete all as specified and directed. |
| 47 | S&F C.P. brass shower rose with 15 or 20 mm inlet of 150 mm diameter Including Taking Down complete all as specified and directed. |
| 48 | S&F Cabinet mirror plastic body for Wash Hand Basin of size 350mmx450mm with 4mm thick looking mirror complete all as specified and directed. |
| 49 | S&F in repairs brass chromium plated Towel rail 'D' type, 600mm long complete with wall brackets complete all as specified and directed. |
| 50 | S&F in replacement 75mm bore cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 complete all as specified and directed. |
| 51 | S&F in replacement 100 mm bore cast iron P trap with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed. |
| 52 | S&F Gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore including taking down complete all as specified and directed. |
| 53 | Taking up or down galvanized steel tubing 15mm bore with fittings complete all as specified and directed. |
| 54 | Taking up or down galvanized steel tubing 20mm bore with fittings complete all as specified and directed. |
| 55 | Taking up or down galvanized steel tubing 25mm bore with fittings complete all as specified and directed. |
| 56 | S&F GI tubes 15mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 57 | S&F GI tubes 20mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 58 | S&F GI tubes 25mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 59 | S&F on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. complete all as specified and directed. |
| 60 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil complete all as specified and directed. |
| 61 | M&L for Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)all as specified and directed. |
| 62 | S&F Joist, channel, angle, or tee sections, fixed pendently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 63 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 64 | S&F Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 65 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 66 | M&L for Preparation of new surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enemal paint over a coat of red oxide primer, complete all as specified and directed. |
| 67 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 68 | S&F Steel rolling shutters of thickness 1.25mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with chain wheel and hand chain, complete all as specified and directed. |
| 69 | M&L for preparation New steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer on steel shutters complete all as specified and directed. |
| 70 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead in cement mortar complete all as specified and directed. |
| 71 | M&L for Half Brick masonry with non modular fly ash bricks of class designation 10, conforming to IS :12894, in super structure above plinth and upto floor V level, in cement mortar 1 : 4 (1 cement : 4 coarse sand) complete all as specified and as directed. |
| 72 | M&L for 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) complete all as specified and as directed. |
| 73 | M&L for Preparation of new surface of internal wall and applying 2mm thick Wall care putty including sand papering the puttied surfaces to form an even and smooth surface complete all as specified and directed. |
| 74 | M&L for Preparation of new surface and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete all as specified and directed. |
| 75 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as in all kinds of soil, complete all as specified and directed. |
| 76 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m, as in all kinds of soil, complete all as specified and directed. |
| 77 | M&L for Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :all as specified and as directed 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) complete all as specified and directed. |
| 78 | M&L for Brick work with fly ash bricks straight or curved on plan exceeding 6m mean radius using modular bricks built in cement mortar (1:6) complete all as specified and directed. |
| 79 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 80 | M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified and directed. |
| 81 | M&L for 100 mm thick Plain cement concrete Type D2, 1:4:8 (using 40mm graded stone aggregate) as in sub base levelling course etc, complete all as specified and directed. |
| 82 | M&L for 75mm thick Plain cement concrete (1:2:4) type-B-1 (using 20mm graded stone aggregate) as in hard standing including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 83 | Supply, install, testing and commissioning of LT panel board CPRI approved, indoor type cubical, pedestal type, floor mounted factory made, dust and vermin proof, IP-65 fabricated out of CRCA sheet not less than 2.0 mm thick fixed on angle iron frame of size 50 x 50 x 6mm conforming to Fe 410-0, front openable double stud hinged with locking arrangements ,lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket U type for natural flow of air, complete dust and vermin proof and panel fixed with PCC 1:2:4, type B-1 (Using 20mm graded stone aggregate) platform 60 cm above the ground level and 45 cm below the ground level, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz with copper bus bar of 200 Amps painted with powder coated paint having not less than 100 microns over a coat of zinc chrome primer with seven tank process and general construction confirming to IS-8623 of 1993 comprising the following:- |
| 84 | (a) Copper bus bar 300 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar-1 Set(b) MCCB, 4P, 200 Amps with Adj thermal & fixed magnetic release 36 KA at 415 Volts (Incoming)-01 No.(c) (Outgoing) MCCB, 4P, 125 Amps with ultimate breaking capacity of 36 KA at 415 Volts with Adjustable thermal & fixed magnetic release 36 KA at 415 Volts (Incoming)-02 Nos. (d) (Outgoing) MCCB, 4P, 63 Amps with ultimate breaking capacity of 25 KA at 415 Volts with Adjustable thermal & fixed magnetic release 25 KA at 415 Volts (Incoming)-01 No.(e) (Outgoing) street light timer nature switch 3 to 5 KW -01 No. (f) MCB DP 32 Amps,16 KA-02 Nos,16 KA(g) Digital Voltmeter 0-500 V of size 96 X 96 mm square with selector switch-01 No.(h) Digital Ammeter 0 to 500 A of size 96 X 96 mm square with selector switch-01 No.(j) R,Y,B phase indicating lamp assembly with HRC fuse protection - 1 No. (k) CT's Coils of suitable ratio - 01 Set. |
| 85 | M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mmm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead 25mm x 5mm thick GI strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.Notes :- (a) Main earth lead beyond 7.5 metre shall be measured and paid for separately.(b) The quoted unit rate shall also deemed included for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering 20mm GI Pipe medium grade 2.7 m long, GI protection pipe light grade 40mm dia and wire mesh, test point, charcoal dust/breeze etc. |
| 86 | M&L for 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. complete all as specified and directed. |
| 87 | Taking down/out old unserviceable aluminium cable/ Cross linked poly-ethylene (XLPE) insulated, LT cable of any size from pole/ laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles /walls/ceilings/ equipments etc. complete all as specified and directed. |
| 88 | M&L for one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size 95 sqmm 3.5 core size direct in ground including excavation,sand cushioning, protective covering and refilling the trench etc complete all as specified and directed. |
| 89 | M&L for Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. including taking down old unserviceable items complete all as specified and directed. |
| 90 | M&L for 25 mm dia GI pipe medium garde for fixing air termination rod as pipe of height 1.2 m each complete all as specified and directed. |
| 91 | Supply & fixing aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip on parapet or surface of wall for lightning conductor complete all as specified and directed. |
| 92 | Supply & fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.including taking down old u/s items complete all as specified and directed. |
| 93 | Supply & fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts, check nuts and spring washers etc. complete all as specified and directed. |
| 94 | M&L for Plain cement concrete1:3:6 Type C2(1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) for foundations filling and mass concrete complete all as specified and directed. |
| 95 | M&L for Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.including taking down old u/s items complete all as specified and directed. |
| 96 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc complete all as specified and directed. |
| 97 | Taking down old point wiring complete for light/fan/socket(5/15 Amps)/AC point/bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps, ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 98 | Taking down old DBs, MCCB , MCBs of any size and capacity & making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 99 | Taking down old sub main wiring/cable of any size and capacity including making good to the disturbed surface to match with the existing complete all as specified and directed. |
| 100 | Taking down old unserviceable exsiting ceiling/wall mounted/exhaust fan of any size and making good to the disturbed surface to match with the existing & deposite in MES store yard complete all as specified and directed. |
| 101 | M&L for Group-C wiring for Light point / Fan point / Exhaust Fan point/ Call Bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc, complete all as specified and directed. |
| 102 | Supplying and fixing 3 Pin 5/6 A modular socket outlet complete all as specified and directed. |
| 103 | Supplying and fixing 15/16 A modular socket outlet complete all as specified and directed. |
| 104 | Supplying and fixing modular switch one way 6 Amps on the existing modular plate & switch box including connections but excluding modular plate etc, complete all as specified and directed. |
| 105 | Supplying and fixing modular switch one way 16 Amps on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified and directed. |
| 106 | Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc complete all as specified and directed. |
| 107 | M&L for Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for light point , 5 Amps socket, 16 Amps power socket & sub main wiring complete all as specified and directed. |
| 108 | 2 X 1.5 Sqmm + 1 X 1.5 Sqmm earth wire |
| 109 | 2 X 2.5 Sqmm + 1 X 2.5 Sqmm earth wire |
| 110 | 2 X 4 Sqmm + 1 X 4 Sqmm earth wire |
| 111 | 2 X 6 Sqmm + 1 X 6 Sqmm earth wire |
| 112 | Supply and fixing (4FT) 20 W LED fitting baten fro surface and wall conduit mounting High Transmissitivity diffuser High lumen Output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod complete all as specified and directed. |
| 113 | S&F LED Panel light 2x2 ft., 36 Watts (System lumen efficacy >135 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) complete all as specified and directed. |
| 114 | S&F LED base street lamainare 35 W with pressure die cast aluminium housing with Poly carbonate coverand high power LEDs and secondary lenses with IP 66 Protection including 40 x 6mm flat iron clamps,nut,bolts,washer with 32 mm dia GI pipe light grade bracket bend to shape not less than 1.2 m long complete all as spcified and directed. |
| 115 | Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) complete all as specified and directed.Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 116 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. complete all as specified and directed. |
| 117 | Supply and fixing in repair MCCB, AC 415 V, 50 HZ, fixed type, capacity 125 Amps, 4 Pole, 36 KA, suitable to be fixed in 4/6/8/12 way TPN DB complete all as specified and directed. |
| 118 | Supply and fixing in repair MCB DB double door SPN 12 Way with 200 Amps rated copper bus bar complete all as specified and directed. |
| 119 | Supply and fixing SP 5 To 32 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 120 | Supply and fixing SPN 63 Amps rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 121 | Supply and fix MCB TPN 40 Amps 4 Pole, with breaking capacity 10 KA along with replacement of old unservceable one complete all as specified and directed. |
| 122 | M&L for Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthingcomplete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender