Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #56351779

Tender For special Repair To Roof Treatment Of Certain Bldgs In The Klp (881) And special Repair To Bldg No T-22 & T-29 (6 Madras) At Gulpur Under Age B/R-Ii Of Ge 881 Ews

Issued by Statutory Bodies & Commissions/Committees · Poonch, Jammu and Kashmir
Tender Value
44.17 Lakhs
Estimated cost
Bid Submission
30 Jul 2026
21 days left
EMD
88340
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Roof Treatment Of Certain Bldgs In The Klp (881) And special Repair To Bldg No T-22 & T-29 (6 Madras) At Gulpur Under Age B/R-Ii Of Ge 881 Ews

BOQ

Name of Work:- SPL REPAIR TO ROOF TREATMENT OF CERTAIN BLDGS IN THE KLP (881) AND SPL REPAIR TO BLDG NO T-22 & T-29 (6 MADRAS) AT GULPUR UNDER AGE B/R-II OF GE 881 EWS
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: SPL REPAIR TO ROOF TREATMENT OF CERTAIN BLDGS IN THE KLP (881) AND SPL REPAIR TO BLDG NO T-22 & T-29 (6 MADRAS) AT GULPUR UNDER AGE B/R-II OF GE 881 EWS Contract No : GE/PNH-50/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B&R Portion:- Taking down existing tarfelt including tiles and demolition of concrete & screed bed complete from roof surfaces including parapets and lowering without disturbing the existing RCC roof slab and removing the same to a distance exc. 1.50 Km and n exc. 5.0 Km including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc and , complete all as specified and as directed.
3Water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification including ponding test as specified :-
4Applying a coat of cement slurry @ 3Kg cement/sqm on cleaned surface of RCC roof slab complete all as specified and directed.
5PCC type B-0, 1:2:4 (using12.50mm graded crushed stone aggregate ) as in padding to roof slab and finishing surface smooth and even to maintain levelling on existing slab complete all as specified and directed.
610mm thick screed bed or bedding layers in cement mortar 1:4 on roof slab including parapet with mixing of liquid water proofing compound @ 200ml per 50 Kg of cement bag complete all as specified and as directed.
7Applying bitumenous primer conforming to IS-3384 @ 0.3 ltrs per Sqm over plastered surfaces of roof including parapet surface.
8Applying a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-3384 @ 1.20Kg per Sqm over primer surfaces of roof slab including parapet surface.
9Providing a layer of polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen with torch application method including end overlaps not less than 150mm and side lap 75mm, membrane shall be five layered with centre core as 90 microns high density polyethylene film, minimum weight of membrane shall be 3.60Kg/ Sqm, overlaps shall be sealed with suitable adhesive as per manufacturer,s instructions, polymeric membrane shall be taken to a height of 60cm (min) and inserted inside the groove of parapet wall and shall be finished by a membrane flashing complete all as specified and directed.Note:- Bitumen coat shall be measured and paid for separately
10Applying a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-3384 @ 1.20Kg per Sqm over APP membrane and blinded with dry fine sand @0.50Kg/sqm dusted over bitumen coat complete all as specified and directed.
11Taking down cement plaster on wall of any desription incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
12M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work mixed with liqued water proofing compound as per manufacturer instructions finishing the surface even and smooth without using extra cement all as specified and as directed.
13Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
14Material & Labour for applying One or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surfaces including preparation of old surfaces all as specified and directed.
15Taking up or down 25mm or 32mm bore steel tubing and connections including cleaning, threading for refixing or removal to store, all as directed.
16Refixing old steel galvanized tubing of 25mm bore including all fittings in new or old position as in walls, ceiling, floors etc, complete, all as specified.
17Galvanized steel water tubing, 25mm bore, medium grade, with all fittings , fixed complete to walls, ceilings or laid in floors.
18Ditto item no 16 above but 32mm bore for over flow with all fittings, complete all as specified and directed.
19Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of exc 250 & n exc 500 ltr capacity.including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
20Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. of exc 500 & n exc 1000 ltr capacity including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.
21Dismantling water tanks of any description, exc 500 & n exc 1000 litre capacity and removing from site.
22Dismantling water tanks and removing to store of capacity exc 250 & n.exc 500 ltrs.
23S&F Rotational moulded PVC water tanks of 500 Ltrs capacity, cylindrical vertical with closed top hoisted and fixed in position. Make:Vectus,Polycon & syntex
24S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top ) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity , all as specified in SSR Part-I. Make:Vectus,Polycon & syntex
25S&F and repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipeand fixed. With 20mm bore
26S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipeand fixed. With 15mm bore
27Demolition of cement concrete (unreinforced) as in ground floor and pavings n.exc 15cm thickness below or above ground level all as specified.
2825mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregates) as in levelling course to receive floor finishes all as specified and directed.
29Material and labour for heavy duty endura tile 10 mm thick jointless, including 15mm thick screed bed or bedding layer in CM 1:4 for laying floor finished, with grey cement and pigment, set jointed and pointed in near cement slurry in floors complete all as specified and directed.
30Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and directed.
31M&L brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius walls built in cement motar 1:4 complete all as specified and directed.
32M & L for Plain cement concrete 1:2:4 type B-1, (using 20mm graded stone aggregates) as in bed block, coping, benching and similar work including necessary form work complete all as specified and directed.
33Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
34Refixing of (110mm dia) rain water PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with the help of MS clamp @ 1.0m centre to centre , complete all as specified and directed. (Note:- rates are inclusive of MS clamps)
35S&F of (110mm dia ) rain water PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including MS clamps @ 1.0m centre to centre, complete all as specified and directed.
36S&F PVC (SWR) bends 110mm radius
37Demolition of cement concrete (unreinforced) as in ground floor and pavings n.exc 15cm thickness below or above ground level all as specified.
38Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified.
39M&L for 75 mm thick PCC 1:4:8, type D2, using 40 mm graded aggregates as in sub base in floor etc, all as Std as directed.
40Chequred cement concrete tiles, 30cmx30cmx2.5 cm including 15mm thick screed bed or bedding layer in CM 1:4 for laying floor finished, with grey cement and pigment, set jointed and pointed in near cement slurry in floors complete all as specified and directed.
41M & L Machine cut kota stone slab in flooring 18 to 20 mm thick over and including 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
4225mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregates) as in levelling course to receive floor finishes all as specified and directed.
43M&L for kota stone slab 16-18mm thick in riser or steps, skirting, dado and pillar laid over and including10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade fo the slab including rubbing and polishing complete all as specified and as directed.
44Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
45S&F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantry, rails, fasteing, heavy bracket framing (Beam, tee, angle, chanel or flat section), including distance pieces, cleats wind ties etc. confirmig to Fe - 410- W including cutting, welding & necessary fittings such as nut bolt, plate complete all as specified and directed.
46Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings including ridges all as specified and directed.
47S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
48Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
49Dismantling wall and ceiling board (fibre, pulp, PVC, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets.
50S&F Anodised aluminium snap grid frame work for false ceiling of size 605 x 605mm with hangers 3 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long 4mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid complete all as specified and as directed.
51Taking down cement plaster from stone/brick walls including raking out joints for keys and scrubbing down with water etc, complete all as specified and directed.
52Rendering 15 mm thick in CM 1:6 on fair faces of brick work or stone work, finished even & smooth without using extra cement all as specified and directed.
53M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work mixed with liqued water proofing compound as per manufacturer instructions finishing the surface even and smooth without using extra cement all as specified and as directed.
54Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
55Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. One or more coats on old surfaces including preparation of old surfaces complete
56Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm over new surfaces complete all as specified and directed..
57Material & Labour for applying One or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over old surfaces including preparation of old surfaces complete all as specified and directed.
5850mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection and PCC path finished even and smooth with out using extra cement including forming and filling of joints with bituminous filler all as directed at site.
59Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames).
60Taking down Chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutters from the frames).
61S&F 30 mm thick Flush shutters, solid core, construction, with block board core and plywood face panels, commercial type on both sides with particle board core all as specified and as directed.
62M&L 2nd class hard wood, 30 mm thick, glazed and skeleton shutter, divided into square, with plain, chamfered or rounded mitered and rebated sash bars, any number of panels, prepared to receive glass, gauge etc. edges of frames chamfered or rounded, fitted with cut and mitered beads for securing glass etc. size of members as specified in SSR Part I clause 8.24 (b) kiln seasoned and chemically pressure treated complete, all as specified.
63Steel windows combination of glazed and gauzed with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
64S&F 300mm long alluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or xtruded section and fixing bolts and sliding of extruded section.
65S&F for 150mm size MS door handles.complete all as specified and as directed.
66S&F for 150mm long MS barrel tower bolts complete all as specified and as directed.
67S&F for 100 mm long mild steel butt hinges, medium weight, cold rolled and fixed.
68S&F for 300 mm, mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete.
69M&L for Plain, solid, 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joint etc complete.
70M&L for preparation of new wooden surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer.
71M&L for two coats of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer etc all as specified and directed.
72Sheet glass, ordinary quality, 3 mm thick and glazing with oil putty or wooden beads, in square n exc. 0.5 Sq.m pane, complte all as specified.
73S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aparture 1.18mm and fixed with tinned tacks or galvanised wire stapple
74Preparation of undecorated steel surface of any description exc.10 cm. in width or girth and applying one coat over a coat of primer complete all as specified.
75M & L for Plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain including necessary formwork complete all as specified and directed.
76Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed.
77Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and directed.
78Walling of random rubble, brought upto course, well bonded, bedded and solidly hearted, built in CM 1:6.
79All as per item No 77 above but except stone.
80E&M Portion:- Taking down carefully unserviceable copper/aluminium point wiring including all fittings and making good to disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
81M&L for Point wiring with 2 x 1.5 sqmm (as phase and neutral) and 1 x 1.5 sqmm (as earth continuity conductor) multistranded copper conductor cable connected to common earth dolly,1100 volts grade , FRLSH, PVC insulated and including PVC casing capping of suitable size with PVC boards of appropriate sizes and ISI Mark all requisite accessories complete for the followings:-
82One light / fan point controlled by one switch
83One 5 pin, 6 A socket outlet on the same board
84One 5 pin, 6 A socket outlet on the independent board.
85All as per item No 79 here-in-before but with two 4sqmm size cables as phase and neutral and one 4 sqmm size cable as earth continuity conductor for one 16/20 Amps socket outlet independent -ditto-
86S&F ceiling rose, 3 terminal, surface bakelite 65 x 50mm complete all as specified and as directed.
87S&F Piano type switch, 1 way,6 Amps, flush type, all as specified and as directed.
88S&F socket outlet 2 in 1,5 pin ,6 Amps, flush type all as specified and as directed.
89S&F Switch socket combination 5 pin, 6 Amps, flush type all as specified and as directed.
90S&F Switch socket combination 2 in 1, 5 pin and 15 Amps, flush type all as specified and as directed.
91S&F Lamp holder insulated body all as specified and as directed.
92S&F Inverter type LED Lamp, 12 watt, all as specified and as directed.
93S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep complete all as specified and as directed.
94S&F LED light fittings, 1x20 w LED, 230 V complete with all accessories internally per wired including and connecting up with PVC insulated and sheathed, 1100 V grade, flexible, multistranded copper conductor three core cable complete all as directed.
95S&F in repair building security light fittings, 35 watt LED,230 V AC out door type pre-wired, IP-65/66 protection, with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket complete all as directed.
96M&L submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLSH), 1100 volts grade of size 4 Sqmm and one single core 2.5 Sqmm as earth continuity conductor drawn into PVC casing capping complete all as specified and directed. NOTE: (i) Two run of 4 Sqmm and one run of 2.5 Sqmm copper cable incl casing caping shall be measured as one length.
97S&F in repair Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed.
98S&F in repair Sheet Metal enclosure for SPN DBs, 12 Ways, Double Door (IP-43), with netral link complete suitable for 240 Volts, AC, 50 Hz complete all as specified and directed.
99S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed.
100S&F in repair MCB, SP 240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed.
101M&L in repair incl taking out old unsv ceiling fan from site of capacity 1200/1400 mm sweep and replacement with and incl new BLDC ceiling fan of 1200 mm sweep, 230 V, 50 hz incl all connecting accessories complete all as directed by engineer-in-charge.
102M&L in repair incl taking out old unsv exhaust fan from site and replace with new exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm inc all connecting accessories complete and as directed by engineer-in-charge.
103Takingdown the old unsv water heater/geyser of 25 Ltr incl supply and fix new electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified.
104M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level, connected to GI earth wire 4mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft / loose soil, P.C.C 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer,charcoal and testing on completion including dismantling unserviceable earthing complete all as specified and as directed.
105S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as directed.
106M&L for twin core aluminium cable of size 16 sqmm 2 core 1100 volts grade heavy duty cable PVC insulated, served with inner sheateing of PVC sheated in service connection suspended by insulating hangers not more than 1 mtr apart incl taking down old u/s cable all as specified and all as directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56351779
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.17 Lakhs
LAST DATE 30-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Roof Treatment Of Certain Bldgs In The Klp (881) And special Repair To Bldg No T-22 & T-29 (6 Madras) At Gulpur Under Age B/R-Ii Of Ge 881 Ews
Basic Detail
Tender No GE/PNH-50/2026-27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 07 Jul 2026
Submission Date 30 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 44.17 Lakhs
Tender Fee 500
EMD 88340
Exemption Available
Document List
BOQ_870235.xls
d07b8ed0-aff3-400a-93f6-8c8bbd77b32d.html
TENDER.pdf
Tendernotice_1 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_870235.xls

html

d07b8ed0-aff3-400a-93f6-8c8bbd77b32d.html

pdf

TENDER.pdf

pdf

Tendernotice_1 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail