Tender For Addition/Alterations And Special Repairs Of Selected Old Married Accn At Jamnagar Military Station

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
13 Crore
Estimated cost
Bid Submission
04 Aug 2026
18 days left
EMD
9.75 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition/Alterations And Special Repairs Of Selected Old Married Accn At Jamnagar Military Station

BOQ

Name of Work:- ADDITION/ALTERATIONS AND SPECIAL REPAIRS OF SELECTED OLD MARRIED ACCN AT JAMNAGAR MILITARY STATION
Sl. No. Item Description
1Dismantling of stone slabs and tiles of any description in any position or thickness in floors aprons roof slab etc laid bedded and pointed in any mortar complete all as specified and directed.
2Dismaltling floor, hearth or wall tiling incl cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
3Supply and fixing of Glazed ceramic tiles in vertical surface 450X 350X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick plaster in cement mortar 1:4 complete all as specified and directed.
4M&L 20mm thick Granite (of any type) work (table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm thick screed bed in CM 1:3 and providing necessary holes for gas pipe / water supply pipe etc. complete all as sppecified and directed.
5M&L Moulding to Granite (single or double) slab including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as sppecified and directed.
6M&L Machine cut & polished Kota stone slab 20-25 mm thick laid over screed base, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab steps, jambs, pillars, window- cills, flooring etc including 20mm thck screed bed in cement mortar 1:3 complete all as sppecified and directed.
7S&F Non-skid ceramic tiles 7 to 8mm thick (square/rectangular ) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in cement mortar 1:4 complete all as sppecified and directed.
8S&F Ceramic tiles 7 to 8mm thick (square / rectangular ) area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floor/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thck screed bed in cement mortar 1:4 complete all as sppecified and directed.
9Demolition of concrete of any description and in any position not other wise specially provided for cement concete (unreinforced) including removal of debris debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as sppecified and directed.
10M&L 25 mm thick cement concrete type B-1, 1:2:4, (20 mm graded crushed stone aggregate) as in leveling course below floor complete all as sppecified and directed.
11M & L 75mm for PCC 1:2:4 type C-2 (using 40mm graded crushed stone aggregates) as in flooring, finished surface even & smooth without using extra cement laid to slope 1:12 in alternate bays each bay not exceeding 2.5m length, 10mm groove at junction of wall and plinth protection complete all as sppecified and directed.
12M&L 75 mm thick cement concrete type C-2 , 1:3:6 (20 mm graded crushed stone aggregate) as in subbase complete all as sppecified and directed.
13M&L providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern with rubberied finish coated with top 4-5 mm thick anti abrasive material as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying if inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
14M&L Providing, cement concrete in kerbs type B-1, 1:2:4 (20mm graded crushed stone aggregate) having rounded or chamfered on edges including necessary formwork complete all as specified and directed.
15Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site complete all as specified and directed. Note - Rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in cement mortar 1:3 all as directed.
16Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site complete all as specified and directed. Note - Rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in cement mortar 1:3 all as directed.
17Refixing in same opening shutters of any description exc 1 sqm but n exc 2 sqm complete all as specified and directed.
18Suppling & fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
19M&L for Solid PVC Door Frame of size 50mm x47mm made out of 5mm wood grain printed PVC sheet including all edges printed to match the shade reinforced with M.S. square tube, complete all as specified and directed.
20S&F Pressed steel frames for doors size 125 mm X 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
21S&F Pressed steel frames for doors size 105 mm X60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
22M&L for providing cement concrete type B-0, 1:2:4 using 12.5 mm (using geaded crushed stone aggregate) filling in Pressed steel hollow door section complete all as specified and directed.
23M&L applying one coat of black bituminus paint on Surfaces of any description wood,steel, iron, concrete, brick, stone, etc., exceeding 10cm in width or girth complete all as specified and directed.
24S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (any number of Panel) with lock rail and panel of 12 mm thick veneered particle board with commercial veneering on both faces,. The size of rail and styles as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
25S&F factory made 35mm thick 2nd class hard wood glzed & skeleton door shutters,open rebated and prepared to recive gauge etc(without sash bars) edgs of framing plain, chamfered or etc,size of members of shutters as specified in SSR Pt-I, Sec-8 Clause 8.20 (a) without sash bar etc., complete all as specified and directed.
26S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples or with second class hard wood beadings complete all as specified and directed.
27M&L preparation of new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
28M&L preparation of new untreated Steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and directed.
29S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B weight of section frame 1.248 kg/m and shutter section weight 0.547 kg/m duly fitted with neoprene beading, glazing clips, tinted glass panes 5.0 mm nominal thickness, aluminium wire cloth 0.45 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make complete all as specified and directed.Note :-Rate shall be included all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc
30S&F powder coated anodised aluminium ventilator with fixed aluminium frame of size 65 x 40 x 1.98 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and make complete all as specified and directed.Note :- Rates shall be included all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc
31S&F mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works complete all as specified and directed.
32S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed 100mm long complete all as specified and directed.
33S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 250 mm long complete all as specified and directed.
34S&F in Aluminium handles, cast type, anodised 100mm long complete all as specified and directed.
35S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor complete all as specified and directed.
36S & F 100mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
37S&F in repair 25mm dia stainless steel curtain rail, cut in required length and size to fit with opening including fixing on bracket with necessary screws fitted on bracket and decorative nobs on sides with necessary arrangement complete all as specified and as directed.
38S&F in repairs curtain rod side brackets of stainless steel, angular or cantilever type fixed to wall with 02 nos screws on each bracket and fitted screws for fixing curtain rod incl CP/stainless steel carved decorative design plain metal colour nobs with fixing arrangement for curtain rod using a screw complete all as approved.
39Taking up or down existing unserviceable mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings & removing to store complete all as specified and as directed.
40Taking up or down existing unserviceable mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings & removing to store complete all as specified and as directed.
41Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with cement mortar 1:6 complete all as specified and as directed.
42Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with cement mortar 1:6 complete all as specified and as directed.
43Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key,scrubbing down with water to receive plaster including necessary all scaffolding complete all as specified and as directed.
44M&L for rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair faces of brick work or on one side of lathing, finished even and smooth without using extra cement complete all as specified and as directed.
45M&L for rendering on fair faces of brick work in two layers i.e, 5 mm thick in cement mortar 1:4 mixed with liquid water proofing compound 3% of cement, over and including 10 mm thick rendering in cement mortar 1:6 on stone masonry surfaces or surface other than fair faces of brick work or on one side of lathing complete all as specified and as directed. Note:-Liquid water proofing compound shall be measured and paid for separately as “Supply only”
46M&L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling including finishing even and smooth without using extra cement complete all as specified and as directed.
47M&L Preparation of newly plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
48M&L newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying cement based wall care putty 1.5mm thick to wall surface including prepration of surface complete all as specified and directed .
49M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
50M&L Preparing old decorated surfaces including complete removal of existing treatment, scraping down, washing, rubbing down and stopping of painted surface of walls & ceiling including roof projection / chajjas and by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying finishing walls with premium acrylic smooth exterior paint with Silicone additives of required shade on two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9lit/10 sqm complete all as specified and as directed.
51M&L Preparing old decorated surfaces including complete removal of existing treatment, scraping down, washing, rubbing down on ceiling and applying two coats of white wash complete all as specified and as directed.
52M&L Preparing old decorated surfaces including complete removal of existing treatment, scraping down, washing, rubbing down of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying cement based wall care putty 1.5mm thick to wall surface complete all as specified and as directed.
53M&L Preparing old decorated surfaces including complete removal of existing treatment, scraping down, washing, rubbing down of old plastered surfaces of walls and applying two coats of oil bound distemper to wall surface complete all as specified and as directed.
54Disconnecting existing tanks exc. 250 and n.exc. 500, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required re-connecting and re-fixing inposition complete all as specified and as directed.
55S&F as in repairs light coloured (Ivory) vitreous china, wash hand basin of size 550mm X 400mm flat back with pedestal Including bracket , CP waste coupling ,chain and plug, 2 Nos PVC connection 15 mm size & 45-60cm long & PVC Waste coupling & flexible waste pipe complete all as specified and as directed.
56S&F in repairs PVC (SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
57S&F in repairs PVC (SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
58S&F in repair 110mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed.
59S&F in repairs PVC (SWR) bend any radius, 110 mm dia complete all as specified and as directed.
60S&F in repairs PVC (SWR) bend any radius, 75 mm dia complete all as specified and as directed.
61S&F in repairs 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent complete all as specified and as directed.
62S&F in repairs fancy type chromium plated bib taps,15 mm bore, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
63S&F in repairs pillar taps 15 mm dia, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe and fixed complete all as specified and as directed.
64S&F in repairs angle cock chromium plated with long shank and cup (concealed type) 15 mm dia screwed down, high pressure with crutch or butter fly handle, screwed both ends, fixed complete all as specified and as directed.
65S&F in repairs brass CP wall Mixer for mixing hot & Cold water screwed down for iron pipe and fixed and joint with adhesive, taflon tape complete all as specified and as directed.
66S&F in repairs Corner Glass shelf 300mm superior quality with CP tubular framing & brackets complete all as per sample complete all as specified and directed.
67S&F in repair Soap dish, cromium plated , any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
68S&F in repair CP tubular towel rail 20 mm dia. D type 60 cm long aluminium anodised complete all as specified and as directed.
69S&F 600mmx450mm bevelled edge mirror of selected quality glass,mounted on 6 mm thick AC building boards or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
70S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including CI 'P' or 'S' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish with and including and PVC flushing pipe, 32 mm dia complete all as specified and as directed.
71S&F Waste fittings, 32mm brass , chromium plated for glazed ware sinks , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
72S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed.
73S&F in repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
74S&F in repairs PVC valveless syphonic action type ,flushing cistern Low level white,with,with inlet ball valve ,float and handle 10 Ltr capacity including brackets complete all as specified and as directed.
75S&F in repairs sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
76S&F as in repairs stainless steel plate rack of size 30\\"x24\\"x10\\" size as per trade pattern fabricated with 1 mm thick stainless steel sheet suitable for stacking 15 plates with hooks /fittings complete all as per sample complete all as specified and directed.
77Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
78M&L 15mm thick rendering in cement plaster 1:3 with WPC on bottom and side walls of sunken floor including finished even and smooth without using extra cement complete all as specified and directed.
79M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) including curing treated surface for 24 hrs complete including applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces including spout holes complete and all as specified as per manufacturer instruction.
80M&L filling PCC type E-2 1:5:10 (40 mm graded stone aggregate) as in sunken floor after applying appropriate treatment to side walls complete all as specified and directed.
81M&L for 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @3%of cement in bottom of sunken floors complete all as specified and directed.
82Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar. Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement. clean loose rust from bars manually with brush. fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed. Note:- reinforcement shall be measured and paid for separately relevent item.
83Taking down all existing roof treatment and demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and juntion of parapet including removing to a distance exceeding 500 m but not exc 1 KM complete all as specified and directed.
84M&L for providing Water Proofing Treatment to RCC Roof / stone patti surfaces with APP Membrane & roof tiles in the following steps including benching at the junction of wall & roof all as specified & shown in TD. (a) M&L for Rendering 5 mm thick on on fair faces of concrete surfaces on PCC padding in CM 1:3 mixed with and including liquid water proofing compound ISI market as per manufacturer instruction and finish the surface even and smooth without using extra cement for laying APP membrane all as directed. (b) M&L preparation of plastered surface of roof slab by throughly wire brushing washed dried up cleaned all foreign matter and dust and apply one coat of approved bituminous primer@ 0.40 ltr per sqm complete all as specified and directed complete(c) M&L for 3 mm thick APP modified polymeric membrane minimum weight 3kg/sqm and reinforced with non woven polyster reinforcement shall be laid by torch application method over a coat of bitumen S-35 grade C 30/40 applied @ 1.20 Kg/Sqm Note:-APP modified polymeric membrane shall be all as specified & directed. The side overlaps shall be minimum 75mm and end laps shall be minimum 100mm. All Overlaps shall be sealed as per manufacturer's instructions.(d) Providing 40 mm thick PCC 1:2:4 type B-0 (12.5 mm thick graded stone aggregate) as top layer, complete all as specified and directed.
85Supply of integral water proofing compound complete all as specified and directed.
86Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
87M&L pre-cast cement concrete block masonry with solid block of PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate), exceeding 10cm in width and setting in CM (1:6) complete all as specified and directed.
88Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar (Internal dia of pipe in 300 mm) complete all as specified and as directed by the Engineer-in-Charge.
89Supply & laying jointing and testing 300 mm bore reinfirced conctete pipes class NP-3 laid and jointed in cement mortor 1:1 complete with collars or socket/spigot type laid jointed and haunching at side in cement complete all as specified and directed.
90M&L for concrete bed to drain pipes of 300 mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested cement concrete 1:4:8 type D-2 complete all as specified and as directed by the Engineer-in-Charge.
91Demolition of chajja, landing,stair case , Kitchen platform of cement concrete reinforced of cimilar suspended works complete all as specified and directed.
92M & L RCC nominal mix type B-1, 1:2:4 using 20mm graded crushe stone aggregate as chajja, landing, stair case, kitchen platform etc and including necessary formwork complete all as specified and directed.
93S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
94Dismantling boardings, any description, fixed in any position with screws complete all as specified and directed.
95M & L 18/19mm thick Pre-laminated particle board, interior grade, prelamination one side with decorative choice lamination & other side balancing white lamination, fixed with nails as in cupboards / cabinets including locking arrangement complete all as specified and directed.
96S&F 18/19 mm wide 6 mm thick lipping on veneered particle as in cupboard shutter and shelves complete all as specified and directed.
97S&F in repairs 2nd class hardwood plain fillet square rectangular in section wrought sawn secured with screws exc 13 & n exc 25 sqcm in section complete all as specified and directed.
98S&F 75 mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed.
99S&F extruded aluminium alloy handles 100mm long, fabricated type, anodised complete all as specified and directed.
100S&F aluminium anodised 75mm hasp and staple ,safety type with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
101Demolition of stone boulders/PCC blocks , built in cement mortar including all quoins , arches , pillars and including removing debries/rubbish off materials out side of Ministry of defence (MOD) land complete all as specified and directed.
102S&F Rotational moulded poly-ethylene three layer water storage tanks (cylinderical vertical with closed top) 500 litres capacity, white in colour hoisted and fixed in position with and including all fittings 25 mm dia CPVC tank adaptor & 20mm Ball valves high pressure of PTMTand fixtures and as per TD Drg No CEJZ/TD/14 of 1/1 dt 04.10.2013 complete all as specified and directed.
103Dismantling timber scantling 40 sqcm and over in section in any position in framed work complete all as specified and directed.
104Dismantling timber scantling in fillets, rails, posts, rafter,purlin etc under 40 sqcm in section. In framed work complete all as specified and directed.
105S & F Rolled mild steel section as in main and cross beams, hip and jack rafters, purlines where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connectiong plates Fe-410 (Gde-E-250) quality A (box section/Angle section) complete all as specified and directed.Note :- The qty considered is tantative at this stage and it should be got approved from CEA before execution of the work.
106Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
107S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
108S&F of Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
109Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
110S&F GI frame work of size 605 x 605mm, for seamless celing comprising of GI perimeter chanel 0.55mm thick with two unequal flangesof 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified and directed.
111M&L Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wooden fillets or metal frame work and reinforced with GI wire mesh (Fillets metal frame work and GI wire mesh paid separately) complete all as specified and directed.
112M & L Factory made flush shutter 35mm thick solid core construction with block board core and ply wood face panels, commercial type on both side and covered with decorative face veneer both side with lipping/frame to match complete all as specified and directed.
113S & F as in repairs vitreous china wash down water closet European type pedestal pattern with seat & cover with jet spray complete incl fixing of flush pipe etc complete all as specified and directed.
114S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.50 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
115S&F in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm dia for low level cistern & pedestal pan, including all joints complete in all respect as specified
116S&F in repairs counter sunk Vitreous china wash basin (560x410x180mm), white , excluding taps, waste, chain and plug and porcelain stopper but including mounting on granite slab 20 mm thick and fixed with brackets complete all as specified and directed.
117S&F 32 brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary picking , union and cap and fixed complete all as specified and directed.
118S&F in repairs brass CP central hole basin mixer without pop-up and joint with adhesive, taflon tape, complete all as specified and directed.
119S & F in repairs brass chromium plated over head shower with arm 255 mm with flange size fency type with or without swival joints any size including fixing to steel pipe 15mm bore union sand joint with adhesive , taflon tape complete all as specified and directed.
120S&F in repair stainless steel towel rail long (Make:Prayag, Jaquar,Cera or equivalent) Cat No BA -01and as selected,complete all as directed.
121S&F in repairs towel rack (Make: Prayag,Jaquar,Cera or equivalent) Cat No BA-03 and as selected, complete all as directed.
122S&F in repairs toilet paper holder fancy type .(Make:Prayag, Jaquar,Cera or equivalent) Cat No BA-08 and as selected,complete all as directed.
123S&F in repairs glass self 300mm (Make:Prayag, Jaquar,Cera or equivalent) Cat No BEA -43 and as selected, complete all as directed.
124S&F bib tap 15 mm bore with crutch or screwed down, with sink cock swing spout (W/M) with flange Make:-Prayag Cat No 6816 cera/prayag/jaguar complete all as directed.
125S&F Mat finish Coloured Vitrified tiles 10 mm thick (square/rectangular) polished area of each tiles n exc 0.36 sqm in floors/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match in light shade including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
126M&L for guniting/shotcrete using shrinkage controlled, polymer modified fiber reinforcement cementitious mortar ( Fosroc rendroc SP-40 or equivalent) using guniting / shotcrete pumps and allied equipment as required including taking out all loose material from repairable surface cleaning and exposing reinforcement etc where required and applying a coat of epoxy bonding agent to existing concrete surface and rust proof primer to reinforcement before shotcrete/ guniting complete all as repair and as directed
127M&L for providing and laying flowable self-compacting micro concrete (Roff Crete repair of Pidilite or equivalent) having ability to penetrate into the recases of concrete members and behind the reinforcement of the member to be repaired, blend of selected portland cement and specially graded micro fine aggregate, fillers and a range of fluidifiers. Surface to be repaired shall be made clean of loose materials /concrete, dust, oil, paint, grease etc and reinforcement be exposed fully where corroded and scales/corrosion deposit be removed (wherever required supplementary reinforcement shall be fixed and paid under revelent item and including appling rust removal primer on reinforcement and coat of bonding agent (Roff concrete Bond Gp or equivalent) to repair substrate before pouring of micro concrete. Note:- Rates shall be including necessary impermeable framwork where ever required
128M&L for racking of cracks up to 5 mm wide, preparation and crack filling with polymer modified/chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls, roofs of any type or size complete all as specified and directed.
129All as per Item No 128 above but size of Cracks exc 5mm but not exc 10 mm complete all as specified and directed.
130Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting & remvoing the roots completely spraying the suitable chemical(suitable chemical to remove/destroy the plants/roots) (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B-0,1:2:4 12.5 mm graded stone aggregate complete all as directed by Engr In Charge.
131M&L Hard core of guage n.exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
132Excavating in post holes (or similar holes) in hard dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed
133M & L for PCC 1:3:6, type C-2 (using 40 mm graded stone aggregates) as foundation and mass concrete complete all as specified and directed.
134M&L for preparation of new plastered surface of wall , chalk whiting, on plastered surfaces prepara-tory to distempering and applaying two coat of oil bond distemper complete all as specified and directed.
135S&F Rotational moulded poly-ethylene three layer water storage tanks (cylinderical vertical with closed top) 1000 litres capacity, white in colour hoisted and fixed in position with and including all fittings 25 mm dia CPVC tank adaptor & 20mm Ball valves high pressure of PTMTand fixtures and as per TD Drg No CEJZ/TD/14 of 1/1 dt 04.10.2013 complete all as specified and directed.
136Disconnecting existing tanks exc 500 and n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required re-connecting and re-fixing in position complete all as specified and directed.
137Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
138Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
139Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
140Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed.
141Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed.
142Taking down existing energy meter from site and deposit to MES storeyard and refixing the same meter after completion of work complete all as specified and directed.
143M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-(a) One light point controlled by one, one way switch 5 Amps
144All as per item No. 143.00 above but One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
145All as per item No. 143.00 above but One light point controlled by one, two way switch 5 Amps
146All as per item No. 143.00 above but One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
147All as per item No. 143.00 above One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
148All as per item No. 143.00 above One bell point controlled by one, bell switch 5 Amps
149All as per item No. 143.00 above but using 2.5 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathed as earth continuity conductor along with wiring and connecting to the common eath dolly.
150All as per item No. 143.00 here in before but using 4.0 sq mm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor FRLSH cable of multistranded PVC insulated unsheathed as earth continuity conductor along with wiring and connecting to the common eath dolly.
151S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body complete all as specified and directed.
152S&F for modular switch piano flush type, single pole, one way, and 6 Amp single module complete all as specified and directed.
153S&F for modular switch piano flush type, single pole, one way, and 16 Amp single module complete all as specified.
154S&F for modular switch piano flush type, single pole, two way, and 6 Amp single module complete all as specified.
155S&F modular socket 6 Amp, 3 pin combined 2 module complete all as specified and directed
156S&F for modular socket outlet multipurpose having provision for 3 pin, 16 Amp, 2 module piano flush type complete all as specified.
157S&F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
158S&F for Bell push modular 6 Amps single module complete all as specified and as directed.
159S & F for lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
160S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
161M&L for in repairs sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 10.00Sqmm and one run of 10.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH (RYBN) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 32 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc complete all as specified and directed. NOTE: Four runs of cable with one run of earth wire and one run of PVC conduit shall be measured & paid for as one length.
162S & F for in repairs sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etccomplete all as specified and directed. NOTE:- Two runs of cable with one run of earth wire cable incuding one run of PVC conduit will be measured as one length including making good the disturbed surfaces.
163S&F and testing factory made sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
164S&F and testing factory made sheet metal enclosure ( for DB's when MCBs to be used) flused in wall single pole and neutral Double door, 8 way, 240 volt with PVC MCB blanking plates, stove enamelled dust cover and vermin proof suitable for incorporation of MCB's and isolator etc, complete all as specified and as directed.
165S&F and testing factory made sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
166S&F for MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
167S&F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
168S&F for MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
169S&F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20 Amps including removal of old unserviceable one complete all as specified and as directed.
170Fixing only water heater storage type (Geyser) vertical/ Horizental type as per site requirement obtained from item No 140.00 above with replacement of unsv 3 core PVC insulated PVC sheated multistranded copper conductor cable and painting of geyser complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
171S&F electric storage water heater of capacity 25 litres, BEE 5 star rated glass lined inner tank, rust proof insulation/rockwool insulation, anode rod safety valve, high pressure with stand capability including proper installation arragements on wall surface with suitable anchor bolt fastener and geyser connection for hold & cold water supply made of stainsteel wire braided connector with chrome finish heavy duty nuts of suitable size & length complete all as specified and directed.
172Supply and fixing ceiling fans complete with blades, down rods, fan remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including electrical connections from ceiling rose to fan teriminal complete all as specified and as directed
173Labour only for refixing the celing fan obtained from item No 141.00 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including painting of ceiling fans complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
174S&F for Highly efficient LED Bulbs, 10 Watt, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap complete all as specified and directed
175S&F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed.
176S&F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed.
177S&F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED light driver holder complete all as specified and as directed.
178S&F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc., with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
179S&F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
180Labour only for refixing the exaust fan obtained from item No 141.00 above with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal including over hauling the fan, painting complete with two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
181S&F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
182S&F for PVC non-metallic rigid conduit ISI marked heavy duty white/ Ivory colour and its accessories heavy duty ISI marked of size 20 mm dia for LAN, telephone and TV connections including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed.
183M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion complete all as specified and directed.Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
184Taking down existing old unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
185Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete all as specified and directed.
186M & L filling dry and clean sand in treches for cable 8 cm deep below and 15 cm above for cable cushioning including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
187Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250x150mm x40 mm complete all as specified and directed.
188Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches complete all as specified and directed.
189Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
190M&L for XLPE insulated screened PVC bedded galvanised steel strip or wire srmoured UG heavy duty electri cable with aluminium conductor 1100 volts grade cross sectional area of 25 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc., complete all as specified and directed.
191All as per Item No 190.00 above but size 4 core x 16 sqmm
192Boring of holes under road pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
193Taking up or down existing unserviceable mild steel water tubing and connections 80 mm dia, any grade, of any description or in any position including fittings & removing to store complete all as specified and directed
194All as per Item No 193.00 above but size 50 mm bore
195All as per Item No 193.00 above but size 25 mm bore
196All as per Item No 193.00 above but size 20 mm bore
197Taking down unserviceable Gun metal valve with iron wheel head, screwed both ends for iron pipe and fixed of size 50 mm bore complete all as specfified and directed.
198All as per Item No 197.00 above but size 25 mm bore
199All as per Item No 197.00 above but size 20 mm bore
200Supply, fixing & laying GI tubing of 80 mm bore, medium grade with both end threaded in any length including cutting threading connection in new or old position including provision of all type of GI fitttings for laid in trenches/wall/ceilling/floor complete all as specified and directed.
201All as per Item No 201.00 above but size 50 mm bore
202All as per Item No 201.00 above but size 25 mm bore
203All as per Item No 201.00 above but size 20 mm bore
204Supplying, connecting, testing & fixing sluice valve flanged ends class 1.6 PN (iron body) having with stainless steel spindle with iron wheel installed complete with nuts , bolts, washer, rubber gasket etc., for size of 80 mm dia including all fittings complete all as specified and directed.
205Supply and fix Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipe of size 50 mm dia pipe including all fittings complete and all as specified and directed.
206All as per Item No 206.00 above but size 25 mm bore
207All as per Item No 206.00 above but size 20 mm bore
208NOTE FOR SCHEDUL OF CREDIT Rs (-) 1542968.00 AMOUNT DEDUCT FROM TOTAL QUOTED AMOUNT AT TIME OF ACCPTANCE OF TENDER. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56351771
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13 Crore
LAST DATE 04-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition/Alterations And Special Repairs Of Selected Old Married Accn At Jamnagar Military Station
Basic Detail
Tender No 800645/JAM/E8
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 07 Jul 2026
Submission Date 04 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 13 Crore
Tender Fee 3000
EMD 9.75 Lakhs
Exemption Available
Document List
70550d74-147e-42a6-a88a-2bfd2ec97f6d.html
800645tender.pdf
BOQ_870184.xls
Tendernotice_1 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 04, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
html

70550d74-147e-42a6-a88a-2bfd2ec97f6d.html

pdf

800645tender.pdf

xls

BOQ_870184.xls

pdf

Tendernotice_1 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders