Tender For Provision Of Examination Hall For Agniveers Alongwith Allied Infrastructure At 1 Eme Centre Under Ge (North) Secunderabad
Tender Value
65.13 Lakhs
Estimated cost
Bid Submission
04 Aug 2026
12 days left
EMD
1.23 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Examination Hall For Agniveers Alongwith Allied Infrastructure At 1 Eme Centre Under Ge (North) Secunderabad
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part - I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl. item No. 1.01 ) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of Provision of Examination hall in single storey including RCC framed structure, ATT, WPT with APP membrane etc complete all as shown on drawings and as per specification. |
| 3 | Lump sum price worked out by the Contractor for “EXCAVATION, EARTH WORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of ₹ 1,38,175.40 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “ROAD/PATH/CULVERT ” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of ₹ 320614.66 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ___________ percent Above / Below the lump sum price of ₹ 1,74,440.24 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “ AREA DRAINAGE ” as listed in Schedule ‘A’ Part - V representing __________ % ___________ percent Above / Below the lump sum price of ₹ 1,12,734.03 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “ EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VI representing ___________ % _________________ percent Above / Below the lump sum price of ₹ 20,001.94 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing ______ % _________________ percent Above / Below the lump sum price of ₹ 1,50,984.40 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for \\"INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing _______ % __________________ percent Above / Below the lump sum price of ₹ 2,48,477.88 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lump sum price worked out by the Contractor for \\"INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IX representing _______ % __________________ percent Above / Below the lump sum price of ₹ 71,211.96 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Schedule 'A' Part - XThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 11.00 to 21.00 |
| 12 | COOLING APPLAINCESSupply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 Ltrs per hour all as Specified and directed by Engr-in- Charge. |
| 13 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA (water cooler, refrigerator, deep freezer) all as Specified and directed by Engr-in- Charge. |
| 14 | Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated all as Specified and directed by Engr-in- Charge. |
| 15 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. all as Specified and directed by Engr-in- Charge. |
| 16 | EXTERNAL WATER SUPPLY Cutting GI/DI/CI pipe of any size and reducing to required length before laying and insertion of 'T's of 50X50X25mm and branches for 50 mm all as specified and as directed. |
| 17 | INTERNAL WATER SUPPLY Supply and fix health faucet (Hand shower) chromium plated with 1.0 metre long easy flex tube 8mm dia with wall hook as per Cat No ALD-CHR-583 of Jaquar or T9940A1 of Parryware or F-8030105 AB of CERA or equivalent of other specified makes, screwed for 15mm stop cock etc complete all as specified and as directed |
| 18 | Supply and fix Two way Bib cock 15mm bore.cast copper alloy.chromium plated with wall flange, fancy type, screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed |
| 19 | S&F vitreous China counter top wash basin of size 600 x 450 x 190 mm with 32mm dia brass chromium plated waste coupling and cast iron brackets complete all as specified and as directed.MAKE: CAT No Jaquar Code- QNS-WHT-7601AT No 10051 or equivalent in HINDWARE/ PARRYWARE/CERA as approved |
| 20 | INTERNAL ELECTRIC SUPPLY S&F sheet metal enclosure vertical type MCCB DB TPN 4 way double door with suitable rated bus bar 415 volts suitable for MCCB TPN as incomer with suitable rated copper bus bar with neutral link and SP/TP MCBs as outgoing and total number of modules equal to MCCB TPN + 12 with blanking plates and fixed flush to wall and making good the disturbed surfaces etc, complete all ass specified and as directed. Note: MCCB / MCB SP/TPN will be measured and paid seperately. |
| 21 | S & F MCCB 100A 25KA FOR VTPN DB's complete all as specfied and directed |
| 22 | EXTERNAL ELECTRIC SUPPLY Supply and Fixing 20 W LED solar street light all in one fitting complete with in built lithium-ion battery, solar panel, charge controller with dusk- to-dawn sensor, mounted on 6 mtr high hot dip galvanized iron octagonal pole fabricated from steel conforming to IS 2062(Grade S355JO), including all necessary accessories, connections and commissioning, complete all aspects. the rate shall be deemed to include Excavation and Eartwork & civil / PCC work requried for erection of the pole |
| 23 | S&F, factory made sheet metal enclosure distribution board (MCCB DB) TPN 8Way, with 200 Amps rated copper bus bar, neutral links and earth bar, double door vertical type, powder coated, suitable for use on 415V, 50Hz supply, MCCB as incomer and MCBs as outgoing IP 43 IK 09 protection, making good disturbed surfaces to match with existing complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender