Tender For Repair / Maintenance Work Of Swimming Pools In The Area Of Age (U) W/S No Ii Under Ge (U) Water Supply, Delhi Cantt-10
Tender Value
35 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
17 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Work Of Swimming Pools In The Area Of Age (U) W/S No Ii Under Ge (U) Water Supply, Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Cleaning of TOI Swimming Pool of size 25 m x 13.5 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 2 | Cleaning of DID Swimming Pool of size 50 m x 21 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 3 | Cleaning of Harbux Stadium Swimming Pool of size 50 m x 21 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 4 | Cleaning of Harbux Stadium Deep Diving Pool of size 16 m x 16 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed. |
| 5 | Cleaning of Harbux Stadium Baby Pool of size 6 m x 4 m before operation using Eco friendly harmless to human beings cleaning material and suitable methods to make the pool water crystal clear bottom of the pool and transperant water all the time before filling as required at site complete all as specified and as directed.NOTE FOR ITEM NO 1 TO 5: Qutoted rate shall include for manpower and cleaning material, safety gears and ladders etc required at for filling up the swimming pools with water. |
| 6 | Cleaning of TOI Swimming Pool of size 25 m x 13.5 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge. |
| 7 | Cleaning of DID Swimming Pool of size 50 m x 21 after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge. |
| 8 | Cleaning of Harbux Stadium Swimming Pool of size 50 m x 21 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge. |
| 9 | Cleaning of Harbux Stadium Deep Diving Pool of size 16 m x 16 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge. |
| 10 | Cleaning of Harbux Stadium Baby Pool of size 6 m x 4 m after completion of operation including complete drain out of pool with the help of required capacity Submersible monoblock P/set and Dry with using cotton cloth as well as complete drain out of filtertion plant and make the plant room neat & clean complete all as specified and directed by Engr-In-charge.NOTE FOR ITEM NO 6 TO 10: Qutoted rate shall include for manpower and required cleaning material, safety gears and ladders etc required at site for drain out the swimming pools de-watering on completion of Operation and Maintenance of Swimming pools. |
| 11 | Supply and fixing in replacement Butterfly valves including with jointing materials, rubber gaskets, old worn out nut-bolts, washers etc complete all as specified and as directed for the following sizes:- |
| 12 | 100 mm dia |
| 13 | 150 mm dia |
| 14 | 200 mm dia |
| 15 | Supply , fixing, jointing and testing in replacement of Cast Iron Non-Return Valve without bypass arrangement, swing type, confirming to IS-5312, flanged ends pressure rating PN 1.0 including taking out old unsv NRV from the existing place of following sizes:- |
| 16 | 100 mm dia |
| 17 | 150 mm dia |
| 18 | 200 mm dia |
| 19 | Supply, fixing, jointing and testing in replacement of Cast Iron Sluice Valve of sizes as under ISI Marked , flanged ends drilled pressure rating PN-1.6 PD Short body, confirming to IS 14846-2000 having stainless steel spindle with cast iron operation wheel at top including taking out unsv Sluice Valve complete all as specified and as directed for the following sizes:-Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 20 | 100 mm dia |
| 21 | 150 mm dia |
| 22 | 200 mm dia |
| 23 | Taking down/out including opening of Pumping set of capacity of above 25 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of tyre coupling & renewal of wornout bearing with & including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory pump set complete all as specified and as directed |
| 24 | Taking down/out including opening of Pumping set of capacity above 7.5 HP to 25 HP, carrying out the servicing, greasing, oiling, gland filling, replacement of tyre coupling & renewal of wornout bearing with & including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory working of pump set complete all as specified and as directed |
| 25 | Taking down/out including opening of Compressor upto 7.5HP at site, carrying out the servicing, greasing, topping up compressor oil of the suitable grade, cleaning of Air filter, replacement of filter element, replacement of suitable size and suitable make bearings, fan belts of same type including suitable size SS nuts, bolts and washers etc and other repairs of minor nature and applying two coats of synthetic enamel paint of existing colour or as directed over a coat of red oxide primer, checking and starting and testing complete pump set for satisfactory working of pump set complete all as specified and as directed. |
| 26 | Material and labour for painting on steel and iron surfaces on the pool operating equipments, filteration plants with two coat of synthetic enamel paint over a coat of red oxide primer as per existing colour scheme or pattern after preparation of old painted surface of any description over 10 cm in width or girth complete all as specified and directed. (NOTE:- Old paint from the steel structures will be scrapped off completely and the surface will be smoothen with water Emery paper.) |
| 27 | Material and Labour for fabrication in replacement of rusted base frame with MS Channel (MC-25/50/75/100/125) for foundation of centrifugal pump sets including one coat of red oxide primer and two coat of black syenthetic enamel paint and inclduing taking out of old base frame and grouting new frame in the existing grouted bolts and nuts, complete all as specified and as directed. (Note:- The contractor will make sure that the frame fixed is leveled and both pump and motor are fully alligned to work smoothly. |
| 28 | Supply and fixing LED tube light fitting integral type suitable for 1 x 18 watts, 220 volts, connector block etc with all accessories internallly prewired and including connecting with twin core flexible copper cable of suitable size including taking down/out old fitting at site complete all as specified and as directed. |
| 29 | Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line including MS Flanges and Flange joints complete with jointing materials complete all as specified and directed by Engr-in-Charge for following sizes:- |
| 30 | 80 mm dia |
| 31 | 100 mm dia |
| 32 | 150 mm dia |
| 33 | 200 mm dia |
| 34 | Supply & fixing CI foot valve of below items rating PN 1.0 flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve complete all as specified and directed by Engr-in-Charge for following sizes:- (Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 35 | 150 mm dia |
| 36 | 200 mm dia |
| 37 | Supply and charging(filling in) in replacement of old worn out / uncleaned / choked filter media in filtration cum recycle plant sutiable for swimming pool approx 5900 kg/filtration plant to maintain filter flow rate 111 M3/Hr as recommended by manufactuere and swimming pool norms following Filter media details complete all as specified and directed:- |
| 38 | (i) Quartz Media Depth – 915 MM (ii) Quartz Pebbles of 1\\" – 3/4\\" size Not less then 100 mm thick layer (iii) Quartz Pebbles of 3/4\\" to 1/2\\" size Not less then 100 mm thick layer (iv) Quartz Pebbles of 1/2\\" to 1/4\\" size Not less then 100 mm thick layer (v) Quartz Pebbles of 1/4\\" to 1/10\\" size Not less then 100 mm thick layer (vi) Quartz sand of assorted sizes Not less than 900mm thick layer (vii) Making Back wash arrangement functional/repair – Back wash arrangement shall be made through the running water hence arrangement shall be made to facilitate the back washing system. (viii)Replacement of Pressure gauges and flow meters from all Filtration plants – 02 Nos of suitable rating (ix) Repair and replacement of Air release pipe and valve from all filteration plants . |
| 39 | M&L cleaning of balancing tank from the bottam and side walls scrubbing with brush for removing fungus and washing with water after removing all the sediments collected at the bottam of balancing tank complete all as spacified and directed |
| 40 | Material and labour for re-winding of electric motor of filltration plant, suction sweeper motor, 3 to 25 HP Motor at swimming pools including replacement of ball bearing and dismantling and refixing, connection, testing etc complete all as specified and directed by Engr-in Charge. |
| 41 | M&L applying two coat of apply synthetic enamel paint with one coat of spray painting of approved colour to LT pannel, pumps and motors of any size complete including MS/CI pipe line and valves etc complete including prepration of old painted surface complete all as specified and directed. |
| 42 | Testing of Swimming pool in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 3328 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for swimming pools purposes. (ii) Collection of water from different sources of water ie. swimming pools in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification Note :- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source swimming pool. |
| 43 | M&L Framed work such as in grills, grating, angle Iron, MS strip, MS Sheet upto 3 mm, etc with ends of bars, shoulder or revetted or forged into spike frame,guard bars barred iron door,railing frame or similar work and locking arrangement including cutting, drilling , welding and painting with two coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed by Engineer-in-charge. |
| 44 | S & F of 1000 ltrs PVC under ground tank tripple layer in and including complete all fittings etc including taking down old unsv complete all as specified and directed. |
| 45 | Supply and fix in Replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed. |
| 46 | M & L for earthing in replacement GI plate 60×60cm ×3.15mm thick electrode and 32x6mm galvanised strip as earthing lead thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level, connected to copper strip of size 25x4mm as earth lead by means of bolts, nuts and washers madeout of copper or tinned brass and protection GI pipe of 40mm dia all as specified and testing complete including earthwork, PCC chamber, RCC chamber cover with handle GI watering pipe 20mm dia, GI funnel with wire mesh, magnesium sulphate, salt, charcoal, lugs etc and method of earthing shall be as per plate No :3 of SSR part -I. |
| 47 | S&F LED Flood light fitting 100 watt energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light, suitable for highlighting architectural facade high mast and general purpose lighting etc complete fixed bracket & suitable size and MS clamp and nut, bolts washers etc complete and connected with twin core cable 1.5 sqmm from flood light to fittings connector complete all as specified and as directed at site |
| 48 | S&F LED Flood light fitting 150 watt energy saving, environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site |
| 49 | S&F LED Flood light fitting 120 watt energy saving environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site. |
| 50 | S&F Energy saving flood light 30 Watt environmental friendly, long life, exclusive innovative die cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site. |
| 51 | S & F in replacement of MCCB 4 pole 415 volts adjustable type 250 amp with breaking capacity 36 kA complete all as specified and directed. |
| 52 | S & F in replacement of MCCB 3 pole 415 volts adjustable type 63 Amp with breaking capacity 25 KA complete all as specified and directed. |
| 53 | S & F in replacement of MCCB 4 pole 415 volts adjustable 200 amp with breaking capacity 36 kA complete all as specified and directed. |
| 54 | Supply and fixing in replacement of MCB Three pole adjustable type 63 Amp capacity 15 KA complete all as specified and directed |
| 55 | Supply and fixing in replacement of MCB single pole adjustable type 6-32 Amp complete all as specified and directed . |
| 56 | S&F in replacement DOL starter 5 HP relay range 7-10Amp in existing starter panel complete all as specified and directed |
| 57 | Taking down the unserviceable FASD ML 1.5 (with MU relay) of any size and replacement with new FASD ML 1.5 (with MU relay) including stainless steel box existing starter panel complete all as specified and directed |
| 58 | Taking down the unserviceable FASD ML 2 (with MU relay) of any size and replacement with new FASD ML 2 (with MU relay) including stainless steel box existing starter panel complete all as specified and directed |
| 59 | Supply and fixing in replacement elecrtonic timer type ST 100 for fixing in panel complete all as specified and as directed. |
| 60 | Supply and fixing in replacement single phase preventor VSP 2 complete all as specified and directed . |
| 61 | Supply and fixing in replacement FRLS PVC insulated industrial grade copper conductor wire of following size, 1100 volts complete all as specified and as directed. |
| 62 | 4.00 sqmm, single core |
| 63 | 16.00 sqmm, single core |
| 64 | 25.00 sqmm, single core |
| 65 | Supply, installation and testing flanged ends T strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. (Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 66 | 150 mm bore |
| 67 | 200 mm bore |
| 68 | Supply and Fixing wooden base brush as per existing old sample suitable for suction sweeper assembly with nylon hair brush with bristles of length 7 cm and 1mm dia each complete all as specified and directed. |
| 69 | Supply and Fixing in replacement FPBC nylon flexible hose pipe 40mm outer dia size heavy duty capacity suitable for suction sweeper complete all as specified and directed. |
| 70 | Supply only TCCA 90 granual in 50 kg drum |
| 71 | Supply only Copper Sulphate crystal ISI Marked |
| 72 | Supply only Soda Ash ISI Marked |
| 73 | Supply only Alum feric solid crystal ISI Marked |
| 74 | Construction of valves pit chamber having internal dimention 90cm x 90cm x 90cm (internal height) with PCC (1:4:8) using 40mm graded stone aggregate for fdn (15mm thick) 23 cm brick wall in (1:4) 10mm thick rendering all around the brick work in cement mortar 1:6 PCC (1:2:4) type B1 coping with 20mm graded aggregate for grounting MS frame incl 13mm thick MS top sheet cover with locking arrangement incl 50mm pad lock with double key arrangement. MS frame made out of 40x40x6mm thick angle iron incl painting of steel surface with two coats of red oxide primer as finishing coat incl necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50mtrs all as specified and including demolition / dismentling of existing valve chamber as directed by the Engr-in-Charge. |
| 75 | M&L for construction of valves pit chamber having dimention 120 cm x 120cm x 120 cm (internal height) using PCC (1:4:8) type D2 (using 40mm graded stone aggregate for foundation 15 cms thick. Brick wall 23 cm thick built in CM (1:4), 10mm thick rendering all around the brick with 1:6 cement mortor, PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping for grouting MS frame including 03mm thick MS top sheet cover with locking arrangement, MS frame made out of 40 x 40 x 6mm thick angle iron including the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any type soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and including demolition / dismentling of existing valve chamber as directed by the Engr-in-Charge. |
| 76 | Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for pipe line, etc in soft/loose soil getting out and levelling of bottom surface to required level complete all as specified and directed. |
| 77 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick soft / loose soil complete all as specified and as directed. |
| 78 | Removing excavated material (Soils) from site to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 79 | Boring holes under road pavement by bocky manually in any type of soil upto 300 mm bore complete all as specified and directed by Engr-in-Charge. |
| 80 | Taking down old unsv GI/CI/DI/Cement/PVC pipe, joints, bends, elbow, tees, rubber joints upto 100 mm dia complete all as specified and directed by Engr-in-Charge. |
| 81 | Supplying, laying, jointing, testing and commissioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches complete all as specified and directed at site for the following sizes:-(Note:- Earth work and tyton joints shall be measured and paid seperately. |
| 82 | 100 mm bore |
| 83 | Material and Labour for DI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of the following sizes confirming to IS:9523 complete all as specified and directed by Engr-in-Charge. |
| 84 | Upto 150mm bore |
| 85 | An amount of Rs 1,05,358.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysJul 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender