Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56351731

Tender For Repair/ Replacement Of Electric Wiring, Distribution Board And Sub Main Wiring And Allied Connected Works In Md And Otm Accn At Mil Stn Kalka Under Ge (I) Jutogh

Issued by Statutory Bodies & Commissions/Committees · Panchkula, Haryana
Tender Value
20 Lakhs
Estimated cost
Bid Submission
28 Jul 2026
16 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/ Replacement Of Electric Wiring, Distribution Board And Sub Main Wiring And Allied Connected Works In Md And Otm Accn At Mil Stn Kalka Under Ge (I) Jutogh

BOQ

Name of Work:- REPAIR/ REPLACEMENT OF ELECTRIC WIRING, DISTRIBUTION BOARD AND SUB MAIN WIRING AND ALLIED CONNECTED WORKS IN MD AND OTM ACCN AT MIL STN KALKA UNDER GE (I) JUTOGH
Sl. No. Item Description
1Taking down carefully point wiring from existing place (light/ fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose, pendant holder, fitting and fixtures, MCB, Main switches, call bell etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper or white colour wash, complete all as specified and directed.
2Taking down carefully unserviceable main switches and distribution boards (single phase or three phase) of any capacity with Isolators/ MCBs/ MCCBs and making good disturbed surfaces and matching with existing colour wash, complete all as specified and directed.
3Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing colour wash complete all as specified and directed.
4M&L for point wiring complete with 1100 volts grade PVC FRLS-H insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including new PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets and various sizes hylam sheets for mounting switch/ sockets, fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed, stranded (Green colour) connected to common earth dolly for One light/ fan/ bell/ Bldg security light point controlled by one single pole one way switch, complete all as specified and directed.
5All as per Srl item No. 04.00 above but for one 3 pin, 5 Amp, socket outlet on the independent board controlled by one single pole one way switch board, complete all as specified and directed.
6All as per Srl item No. 04.00 above but for one 3 pin, 5 Amp, socket outlet on the same board controlled by one single pole one way switch board complete all as specified and directed.
7All as per Srl item No. 04.00 above but for wiring with 2.5 sqmm copper cable and 2.5 Sqmm copper cable as continuous earth wire for one 6 pin 6/16 Amps socket out let on independent board complete all as specified and directed.
8All as per Srl item No 04.00 above but in existing conduit pipe for One light point/ fan/ bell point controlled by one single pole one way switch, complete all as specified and directed.
9All as per Srl item No 05.00 above but in existing conduit pipe complete all as specified and directed.
10All as per Srl item No 06.00 above but in existing conduit pipe complete all as specified and directed.
11All as per Srl item No 07.00 above but in existing conduit pipe complete all as specified and directed.
12S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed.
13S&F socket outlet flush type 5 pin 6 amps (multi purpose) suitable for 240 volt AC Complete all as specified and directed.
14S&F socket outlet flush type 5 pin 15 amps (multi purpose) suitable for 230 volt AC Complete all as specified and directed.
15S&F switch piano 16 Amps flush type, two way suitable for 240 volt AC Complete all as specified and directed.
16S&F fan step regulator socket type suitable/ compatible with BLDC Fan, 100 W, 2 module, 220-240 V complete all as specified and directed.
17S&F modular switch 1 way 6 Amp, 1 module, 240 V, flush type, complete all as specified and directed.
18S&F modular bell push, flush type, 6 Amp, 1 module, 240 V complete all as specified and directed.
19S&F modular socket, 6A-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
20S&F modular socket, 6Amp / 16Amp-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
21S&F modular switch 1 way 16 Amp, 1 module, 240 V flush type complete all as specified
22S&F modular fan step regulator socket type suitable/ compatible with BLDC Fan, 100 W, 2 module, 220-240 V, complete all as specified and directed.
23S&F Modular white cover plate with frame including modular metal flush box, 1 module, complete all as specified and directed.
24S&F Modular white cover plate with frame including modular metal flush box, 3 module, complete all as specified and directed.
25S&F Modular white cover plate with frame including modular metal flush box, 4 module complete all as specified.
26S&F Modular white cover plate with frame including modular metal flush box, 6 module, complete all as specified and directed.
27S&F Modular white cover plate with frame including modular metal flush box, 12 module, complete all as specified and directed.
28S&F in repair ceiling rose polycarbonate body, 65 x 20 mm three terminal, complete all as specified and directed.
29M&L for replacement of call bell electric (ding dong type), 240 Volt, single pole, complete all as specified and directed.
30S&F in repair for lamp holder PVC body with back plate complete all as specified and directed.
31S&F in repair bus bar chamber made out of CRCA sheet 2mm thick powder coated of size 600mm x 450mmx 150mm in IP 65 including making concealed in the wall using nut and bolts and making wall surface good with two coats of colour wash complete with and including following:(a) Incoming MCCB 125 Amp 4 pole 25/16 KA, 415 V-01 No(b) Outgoing Aluminium bus bar duly insulated RBY and black - 01 Set(c) LED indicator RYB - 01 Set
32S&F in repair VTPN MCCB distribution board 4 way fabricated out of 2.00mm thick high quality CRCA sheet with MCCB thermal based release adjustable type 3 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 36 KA, DBs shall be totally enclosed, suitable for 240V/415V, having polyurethane (PU) foam gasket to ensure IP-54 degree of protection for Indoor application as pre IEC 61439-3:2012 (CI.10.3)/IEC 60529. DB shall be robust with tested for impact resistance IK09as per IEC 61439-3:2012 (CI.No. 10.2.6). DBs shall be provided with prefitted cement Guard. DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for insertion of cable /conduits. Distribution Boards shall bre provided with wire set of copper along with the insulated fork type bus bars. DB shall have reversible hinged doors and possibility to allow door opening from left to right or right to left for convenience on site. DB shall have type test reports as per IEC 61439-3 from ERDA or NABL laboratory, complete all as specified and directed.
33S&F in repair TPN Distribution board 4 way fabricated out of 2.00mm thick high quality CRCA sheet, DBs shall be totally enclosed, suitable for 240V/415V, having polyurethane (PU) foam gasket to ensure IP-54 degree of protection for Indoor application as pre IEC 61439-3:2012 (CI.10.3)/IEC 60529. DB shall be robust with tested for impact resistance IK09as per IEC 61439-3:2012 (CI.No. 10.2.6). DBs shall be provided with prefitted cement Guard. DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for insertion of cable /conduits. Distribution Boards shall bre provided with wire set of copper along with the insulated fork type bus bars. DB shall have reversible hinged doors and possibility to allow door opening from left to right or right to left for convenience on site. DB shall have type test reports as per IEC 61439-3 from ERDA or NABL laboratory, complete all as specified and directed.
34S&F in repair sheet metal enclosures for MCB distribution board SPN 12 way double door type with 200 amp rated bus bar and suitable for MCB SPN as incomer complete all as specified and directed.
35S&F in repair sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for MCB SPN as incomer complete all as specified and directed.
36S&F in repair sheet metal enclosures for MCB distribution board SPN 4 way double door type with 200 amp rated bus bar and suitable for MCB SPN as incomer complete all as specified and directed.
37S&F in repair MCCB thermal based release adjustable type 3 pole, 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KA min including testing, complete all as specified and directed.
38S&F in repair MCCB thermal based release adjustable type 4 pole 100 Amps 50 Hz 415 Volts with rupturing capacity 16 KA min including testing, complete all as specified and directed.
39S&F in repair MCCB thermal based release adjustable type 4 pole 125 Amps 50 Hz 415 Volts with rupturing capacity 25KA/16 KA min including testing, complete all as specified and directed.
40S&F in repair MCB SP 6-32 Amp, 240 V 10 KA including all terminals, fittings etc. complete all as specified and directed.
41S&F in repair MCB SPN, 240 volts, 40 to 63 Amps, rupturing capacity 10 KA, complete all as specified and directed.
42S&F in repair MCB TPN 63 Amps, complete all as specified and directed.
43S&F in repair MCB protected socket (modular AC box) 3 Module IN sheet steel / plastic box (with SP mini MCB of 'C' series 25 Amps) complete all as specified and directed.
44M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS-H cable drawn and PVC rigid conduit min 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour) run through PVC rigid conduit and connected to common earth dolly, including taking out the old sub main wiring complete all as specified and directed. Note: Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run.
45M&L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS-H cable drawn and PVC rigid conduit min 20 mm dia with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 6 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly, including taking out the old sub main wiring complete all as specified and directed. Note: Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run.
46M&L for earthing complete with GI earth plate electrode 600mmx600mmx6.0mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including 4 mm dia GI wire as earth lead wire by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point including precast cover, frame and PCC 1:3:6, type C-2, using 20mm graded crushed stone aggregate as in earthing pit including necessary earth work etc, complete all as specified and directed.Note :- (i) PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. (ii) PCC pit cover shall be of precast RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI) including taking out old unserviceable earthing any type.
47S&F in repair 20W, 6500K, 4 feet LED tube light fitting, energy efficient, 240 volts, fixed on wall/ ceiling etc including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
48S&F in repair/ replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
49S&F in repair LED bulb of 9 watt, B22 base, 6500K complete all as specified and directed.
50S&F in repair LED Post top 20 watt decorative type, made of cast aluminium with decorative opal polycarbonate diffuser with IP-65 protection including fixing with suitable size GI pipe, masonry work as required on the top of gate pillar including all fixing accessories, complete all as specified and directed.
51S&F LED luminaire 600 x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
52S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, suitable size bracket made out of 40mm dia GI pipe light grade 1.5m long with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
53S&F in repair capacitor (ISI Marked) 2.5 mfd complete all as specified and directed.
54S&F in repair exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
55S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm including fixing all arrangements, complete all as specified and directed.
56M&L for cutting holes in walls, making good the disturbed surface, grouting nuts for fixing of Exhaust fans with factory made extruded aluminium ventilators with 50 micron powder coating frame of size 63.5 x 38.10 x1.29 mm including 5mm thick frosted glass in lower 55% portion of shutter and stainless steel wire gauge 0.36mm dia and 1.40 aperture in upper 45% of the shutter fixed with and including EPDM gasket to render the glazing, air and water tight etc. with aluminium beads 20mm size, complete all as specified and directed.
57S&F in repair 1.5 Sqmm (Nominal area) FRLS-H PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor, complete all as specified and directed.
58S&F in repair 2.5 Sqmm (Nominal area) FRLS-H PVC insulated and unsheathed single core cable 1100 Volts grade with stranded copper conductor complete all as specified and directed.
59S&F in repair PVC casing n capping of 20mm (1\\") width complete all as specified and directed.
60S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal box type with PVC Box complete all as specified and directed.
61S&F in repair Switch socket combination 3 pin, 5 Amp flush type universal box type with PVC Box complete all as specified and directed.
62S&F 3 core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from cable Junction Box to street light fittings including proper clamping of conductor cu complete all as specified and directed.
63S&F 4 core, 2.5 sqmm, PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from cable Junction Box to street light fittings including proper clamping of cu conductor complete all as specified and directed.
64M&L for preparing old decorated plastered or unplastered surfaces of wall including cornices, pilasters etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coats of oil bound distemper, complete all as specified and directed.
65Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 10 Sqmm 2 core confirming to IS: 7098 (Part-1) complete with proper thimbles, complete all as specified and directed.
66Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade, laid in trenches or duct or passing through pipe or fixed to poles walls of size 25 Sqmm 4 core confirming to IS: 7098 (Part-1) complete with proper thimbles, complete all as specified and directed.
67S&F in repair 1100 volts grade heavy duty 16 Sqmm 2 core service cable PVC insulated aluminium Stranded conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers and porcelain beat not more than I meter apart including 4 Sqmm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
68S&F in repair 1100 volts grade heavy duty 6 Sqmm 2 core service cable PVC insulated aluminium Stranded conductor, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers and porcelain beat not more than I meter apart including 4 Sqmm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
69Supply and Laying concealed rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc including taking out the existing cable and relaying the same complete all as specified and directed.
70S&F in repair LED light fitting 1x9W/1X10W bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
71S&F in repair LED recessed down lighter 09W/10W, 6500K/ 4000K/ 3000K, cut out around 100/107 mm in Radius energy efficient, 240 volts, fixed on ceiling etc incl. connecting up with existing copper conductor wire of suitable size, complete all as specified and directed.
72S&F in repair High efficiency 1x1 recess LED flat panel with high brightness LED for glare-free homogenous illumination. Also for POP ceilings (supplied with wedge brackets). Fixture size: (LxWxH) in (295x295x70) mm & proper fixing in ceiling with cutting & finishing work as required complete all as specified and directed.
73S&F in replacement LED round / square Bollard light of wattage 10W/12W (white / warm white) having aluminium extruded housing with glare free opal / milky diffuser, IP-65 protection including complete excavation work, PCC 1:3:6 for fixing of light, testing & commissioning, fixed on suitable height pipe proper connection complete all as specified and directed.
74M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in copings, bed plates, fixing of hold fasts and other similar works and the like incl weathering, slightly rounded or chamfered angles and throating as directed incl use and waste of necessary form work, complete all as specified and directed.
75S&F in repair LED tube light fitting batten 22 Watt, 6500K inverter type 4 feet, 230V, 4 hours environment friendly, energy efficient ready to use complete fixed to wall with all accessories internally prewired and connecting up with and including twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
76S&F in repair LED inverter Bulb 9 watt, Cool/warm white 6500K, suitable for base B22`, 230 volts, complete all as specified and directed.
77M&L for Acrylic Board with UV printing and LED light with LED module including 1mm electrical wire and ACP sheet 3mm thickness for Glow sign board of suitable size with complete framed work such as grills, gratings, etc including size & shape of letter work complete all as specified and directed.
78S&F indoor decorative wall brackets light fixture made up of Polycarbonate, suitable for 9 W LED lamp B22 base with plastic body suitable for 09/10W LED Bulb complete with 9/10 W LED Bulb complete all as specified and directed.
79S&F in repair on load changeover switch 4 pole 100 Amps capacity with centre handle in sheet steel enclosures complete all as specified and directed
80S&F in repair on load changeover switch 4 pole 200 Amps capacity with centre handle in sheet steel enclosures complete all as specified and directed
81Supply, fixing or laying HDPE double wall corrugated (DWC) pipe 50 mm dia of pressure rating 6kg/cm2 as per IS:16205 fixing on poles, walls under floors, laying on surface etc as required at site including clamps to hold pipe at position complete all as specified and directed.
82Excavation in trenches in soft/ loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cable, pole foundation, etc and getting out, complete all as specified and directed
83M&L for dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified and directed. Note: i) Excavation and earth work measured separately. ii) Punned down thickness shall be measured.
84S&F brick Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified and directed. Note:- Excavation and earth work shall be measured separately.
85Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and directed.
86Removal of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
87S&F in repair 40mm dia GI pipe light grade, laid in trenches/under floor/ on walls for protection of underground complete all as specified and directed.
88S&F metal clad single pole and a neutral enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp, 240V, complete all as specified and directed.
89M&L for servicing of storage type water heater (Geysers) 25 ltr capacity any make by disconnecting electrically and mechanically from all existing lines, opening of bottom and top for inspection complete incl base plate, heating element and copper tank, cable, PVC pipe etc., cleaning carefully and reassembling after necessary repair/ replacement as specified here-in-after and replacement of old unserviceable nut/ bolts and fixing in the same position, complete all as specified and directed.Note :- Spare parts shall be measured and paid separately.
90Supply only heating element 1500 watts push type with gasket ISI marked triangular type, complete all as specified and directed.
91Supply only thermostatic switch suitable for Geysers of any make/ type with temperature range adjustable type 25 to 80 degree centigrade superior quality 20 Amps 220 Volts AC Supply complete all as specified and directed.
92Supply only Incoloy Heating Element 111884-EV for Geyser complete all as specified and directed.
93Supply only Bajaj Heating Element as per IS 4159, complete all as specified and directed.
94Supply only syphon assembly suitable for 25 Ltrs capacity Geysers of Make Venus/ Bajaj with heating element, Rubber gasket as per site requirement as per site complete all as specified and directed.
95Supply only assembly suitable for 25 Ltrs capacity Geysers of any Make as per site requirement of any type having 6/9 hole as per site complete all as specified and directed.
96Supply only PVC connection of 450 mm long & 15 mm dia with brass nut at both end suitable for Geysers complete all as specified and directed
97S&F in replacement 3 pin, bakellite top of 16 Amp, capacity, 240V, only for replacement of burn/ unsv top for geyser, complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56351731
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/ Replacement Of Electric Wiring, Distribution Board And Sub Main Wiring And Allied Connected Works In Md And Otm Accn At Mil Stn Kalka Under Ge (I) Jutogh
Basic Detail
Tender No GE(I)/JUT-47 OF 2026-27
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 07 Jul 2026
Submission Date 28 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
56ac5fa1-a36e-4b13-80be-8064665cb346.html
BOQ_870160.xls
td.pdf
Tendernotice_1 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

56ac5fa1-a36e-4b13-80be-8064665cb346.html

xls

BOQ_870160.xls

pdf

td.pdf

pdf

Tendernotice_1 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders