| Sl. No. | Item Description |
| 1 | Cleaning and de-sludging of septic tanks of following user size of any depth including taking out sludge in any form alongwith all other forign materials by mechanical Pumping equipment with taking all precautionary measures including removal of sludge and other foreign materials out side Defence land complete all as specified and as directed by Engr-in-Charge. (working in foul condition) - 500 Users |
| 2 | All as per Item Ser No 1.00 above but 250 users |
| 3 | All as per Item Ser No 1.00 above but 200 users |
| 4 | All as per Item Ser No 1.00 above but 150 users |
| 5 | All as per Item Ser No 1.00 above but 100 users |
| 6 | All as per Item Ser No 1.00 above but 50 users |
| 7 | All as per Item Ser No 1.00 above but 25 users |
| 8 | All as per Item Ser No 1.00 above but 10 users |
| 9 | Removing carefully the cover slabs of man holes of any size and shape and removing the scum/ sludge including any organic or inorganic matters to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in charge, and setting the man hole cover in position in CM 1:6 after cleaning the sludge for the following size of man holes (Manhole cover if provided new shall be measured & paid seperately) complete all as specified and as directed:- Upto 1.5 mtr depth |
| 10 | All as per Item Ser No 2.00 above but Exc 1.5 mtr depth but n.exc 3.00 meter depth |
| 11 | Cleaning of blocked sewage drain pipe till the flow of sewage/sludge water is smooth including taking out all sludge/mud from pipes by means of roding & remove to a distance exc 50m and not exc 5000m and depositing where as directed by engineer in charge complete all as specified and as directed, for the following size of pipes :- Internal dia 75 mm |
| 12 | All as per Item Ser No 3.00 above but Pipe Internal dia 100mm |
| 13 | All as per Item Ser No 3.00 above but Pipe Internal dia 150mm |
| 14 | All as per Item Ser No 3.00 above but Pipe Internal dia 200 mm |
| 15 | Cleaning and removing of blockage from WC upto first manhole removing all silt, liquid mud from the pipe line by roding etc and depositing the same at a distance exc 50m and not exc 5000 mtrs where as specified and as directed by engineer in charge for following:- In Ground Floor |
| 16 | All as per Item Ser No 4.00 above but In First Floor |
| 17 | All as per Item Ser No 4.00 above but In Second Floor |
| 18 | Cleaning and removing of blockage from floor trap at any location upto first manhole removing all silt, liquid mud or any othe foreign materials by roding and removing the same at a distance exc 50m and not exc 5000 mtrs and depositing where as specified and as directed by engineer in charge for the following:- In Ground Floor |
| 19 | All as per Item Ser No 5.00 above but In First Floor |
| 20 | All as per Item Ser No 5.00 above but In Second Floor |
| 21 | Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning of blocked Gully traps including taking out all sludge/mud by means of roding,remove to a distance exc 50m and not exc 5000 mtrs and depositing where as specified and as directed by Engineer in charge. |
| 22 | S&F in Repairs PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or fixed to walls including clamps complete all as specified and as directed, for the following bore :- 75mm dia |
| 23 | All as per Item Ser No 7.00 above but PVC (SWR) Pipe 110mm dia |
| 24 | S&F in Repairs PVC (SWR) bend complete all as specified and as directed, for the following bore :- 75mm dia |
| 25 | All as per Item Ser No 8.00 above but PVC (SWR) bend 110mm dia |
| 26 | S&F in repair PVC (SWR) junction single (single 'T') equal or unequal complete all as specified and as directed, of the following bore :- 75mm dia |
| 27 | All as per Item Ser No 9.00 above but 110mm dia |
| 28 | S&F in Repairs PVC(SWR) vent cowl complete all as specified and as dirercted for the following bore :- 75mm dia |
| 29 | All as per Item Ser No 10.00 above but 110mm dia |
| 30 | Demolition of Solid block masonry set in CM as in man hole chamber and septic tank etc as in walling complete all as specified and as directed. |
| 31 | M&L for Precast cement concrete block masonry with PCC 1:3:6, type C1, with solid blocks exc 10cm in width and set in CM 1:4 all as specified and directed. |
| 32 | M&L for Rendering 15mm thick in CM 1:3 on concrete/brick / solid block masonry surfaces as in manhole, septic tank etc finished even and smooth without using extra cement all as specified and as directed. |
| 33 | M&L for Preparation of new plastered surfaces of walls and applying two coats of white wash, complete all as specified and as directed. |
| 34 | Demolition of Reinforced cement concrete of any description and in any position complete all as specified and as directed. |
| 35 | M&L for Providing precast RCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in cover slab for manholes, septic tank and similar work set in CM 1:6 all as specified incl necessary form work and placed in position complete all as specified and as directed. |
| 36 | M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed. |
| 37 | Cutting of small trees/plants at the stem removal of the roots of the plants by using acids, cutting around the spout for removing the roots of any size and making good with CM 1:3 incl two coats of cement base paint complete all as specified and as directed by Engineer-in-Charge. |
| 38 | M&L for PVC (SWR) floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) complete all as specified and as directed. |
| 39 | M&L for Cast iron Nahani trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) complete all as specified and as directed. |
| 40 | M&L for PVC (SWR) multi floor trap 100 mm outlet dia with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4, (using 20mm graded stone aggregate) complete all as specified and as directed. |
| 41 | M&L for Fibreglass reinforced plastic (FRP), corrosion resistant drain covers of any size and any shape including frames as directed by Engineer-in-Charge having loading capacity from 2.5-6.0 Tons including key holes/keys to facilitate the lifting and placement of drain covers in the frame complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender