Tender For Supply, Installation, Testing and Commissioning For Thickening Of 33Kv Batote-Patnitop Line From 100Mm2 Dog Conductor To 150Mm2 Wolf Conductor, Re-Aligment/ Shifting Of 33Kv Batote-Patnitop Line At Rakhjarog Area And Rev Ing/Stablisation O
Tender Overview
Project Description
Tender for Supply, Installation, Testing and Commissioning For Thickening Of 33Kv Batote-Patnitop Line From 100Mm2 Dog Conductor To 150Mm2 Wolf Conductor, Re-Aligment/ Shifting Of 33Kv Batote-Patnitop Line At Rakhjarog Area And Rev Ing/Stablisation Of 6.3Mva Receiving Station Patnitop For Smooth Power Supply. Important Note : All Allied And Associated Works Required For Successful Execution Of Above Items Of Works Including Testing And Energisation , Specifically Mentioned Or Not In Above Description But Required At Site Shall Be Deemed To Be Included And Covered In The Quoted Rates.
BOQ
| Sl. No. | Item Description |
| 1 | Survey, Supply, Installation , Testing and Commissioning for 33 kV Line BAY (LILO) of existing Chenani Line at proposed Receing Station Kulwanta |
| 2 | Supply, Transportation, Erection of 11 Mtr LongST Poles (ST410-SP56) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 3 | Supply, Transportation, Erection of 9 Mtr LongST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. |
| 4 | GI V cross-arm with top bracket including clamp |
| 5 | 150mm2 ACSR Conductor |
| 6 | Channel iron Cross arm(100x50x6)mm 10 feet long |
| 7 | Angle iron braces (65x65x6)mm 12 feet long |
| 8 | Angle iron belt (65x65x6)mm 8 feet long |
| 9 | FI Clamps |
| 10 | FI Ties |
| 11 | PG clamps for 100mm2 ACSR Dog conductor |
| 12 | 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 13 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm |
| 14 | 33KV Disc Fitting for 150mm2 ACSR Wolf Conductor |
| 15 | Galvinized Nuts and Bolts |
| 16 | Danger Plates |
| 17 | Anti-Climbing Device with Clamps |
| 18 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5mtr long through GI Strip. |
| 19 | Red Oxide |
| 20 | Aluminium Paint |
| 21 | Cement bottoming 1:2:4 mix as per REC standards .6cum/pole |
| 22 | Aluminium Jointing sleeves |
| 23 | Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete |
| 24 | Guard netting |
| 25 | Dismantling of old conductor and write back to divisional store |
| 26 | Erection of 33KV Isolator with earthing blade (36KV,1250 A, outdoor, 3-poles, 25kA) |
| 27 | Dismantling of 33KV line at Rakhjarog after shifting and carriage of its material to Sub Division Store |
| 28 | 9Mtr Long ST Poles (ST-410-SP56) |
| 29 | ACSR Conductor Dog |
| 30 | Channel iron Cross arm(100x50x6)mm 8 feet long |
| 31 | Angleiron Brace (65x65x6)mm 6ft long |
| 32 | 33KV Polymer composite Disc Insulator 36KV,min failing load 70kN,Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm |
| 33 | 33KV Polymer composite Pin Insulator 36KV,10kN,Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm |
| 34 | Revamping/Stabilization of (6.3) MVA, 33/11KV Receiving Station Patnitop |
| 35 | 33 KV VCB (36 KV, 1250A, 26.2 KA, Outdoor Type) |
| 36 | 33KV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-Phase Tri-Vector meter- 5 Amps, DLMS Compliant (SCADA COMPATABILE) |
| 37 | 33 KV Voltage Transformer ( 33 KV/110 v, 1Ø, Multi-Core, Outdoor), (1No. per Ø) |
| 38 | 33 KV Current Transformer ( 33 KV, 1Ø, Multi Ratio Multi-Core, Outdoor), (1No. per Ø) |
| 39 | 33 KV Lightening Arrestors (30 KV, 10 KA, Station class, ZnO, Porcelain/Polymer) gap less |
| 40 | 33 KV Isolator without Earthing Blade ( 36 KV, 1250A, Outdoor, 3 poles, 25 KA) |
| 41 | 11 KV VCB Panel Board (12 KV, 1250A, 25 KA, Outdoor) |
| 42 | 11 KV Isolator, double break, 3-pole, 600 A, horizontal Type, with Earth Switch |
| 43 | 11 KV 3-core 185 mm2 Cable, FRLS |
| 44 | 11 KV Heat Shrinkable Cable Termination Kit ( Indoor) |
| 45 | 11 KV Heat Shrinkable Cable Termination Kit (Outdoor) |
| 46 | 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets) |
| 47 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip |
| 48 | Galvanised Iron of sorts |
| 49 | a) Battery bank 30 Vm 100 AH of 15 No. cells of 2V each, sealed maintenance free VRLA type, High Impact Polyprophelene copolymer container flame retardant. b) 30 V, 100 AH, Float-Cum-Charger with full wave rectification for 220 V, 1 Phase 50 Hz AC Input Supply |
| 50 | 12 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS |
| 51 | 6 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS |
| 52 | 2 Core 2.5 mm2 Control Cable copper Armoured, 1.1 KV Grade ISI, FRLS |
| 53 | Lugs, Ferrules etc. |
| 54 | 200 mm2 ACSR Conducttor Panther |
| 55 | T Clamps |
| 56 | Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN |
| 57 | Rubber Mat 1mx2m 19mm thick |
| 58 | Fire Extinguisher Co2 type of 4.5kg capacity of control rool |
| 59 | Helmet |
| 60 | Rubber Gloves for 33kv level |
| 61 | Safety Belt |
| 62 | Safety Shoes |
| 63 | Earthing rods (set of 3 rods) |
| 64 | HV Detector all voltages |
| 65 | Yard Lightening |
| 66 | 33 KV Yard Concreting & Metalling |
| 67 | Painting of All Equpiment structures /Gantry structures installed in the outdoor yard |
| 68 | BUILDING (Staff Quarter at Receiving Station Patnitop) |
| 69 | Staff Quarters with Column and Beam structures including Toilet (complete with WC, Washbasin and fittings), electric fittings(fans, LED tubelights, leds powerpoints and other fixtures) White Washing of entire building Complete in all respectsainting of doors and windows etc. Overhead water Storage tanks . Pantry (Note: The Contractor shall submit the building drawing in all respects i.e. structral / architechural prepared by authorised Architect for approval from the dept for execution of works.) |
| 70 | Survey, Supply, Installation , Testing and Commissioning for 33 kV Line BAY (LILO) of existing Chenani Line at proposed Receing Station Kulwanta |
| 71 | Ceramic glazed tiles Fixing 1st quality ceramic glazed tiles conforming to IS:13753 of minimum thickness 5 mm of approved make like NITCO , ORIENT ,, SOMANY, KAJARIA or equivlant make in all colours , shades except begundy,bottle green , black of any size as approved by Engineer - in - charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 72 | Applying white cement based putty of average thickness 2 mm,of approved brand and manufacture,over the plastered wall surface to prepare the surface even and smooth complete. |
| 73 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 74 | New work ( Two or more coats) over and including priming coat with cement primer |
| 75 | New work ( Two or more coats) over and including priming coat with cement primer |
| 76 | Exterior Finishing Finishing walls with water proofing cement paint of reuired shade:. . |
| 77 | Repairing of roof ceiling of control room building by way of supply and replacing damaged (approx 5 CGI sheets heavy duty) , repairing of holding hooks and bitumin washers to stop water leakage Complete job. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender